• Title/Summary/Keyword: 체적온도

Search Result 376, Processing Time 0.028 seconds

Off-design Characteristics for Ambient Air Temperature and Turbine Load of Gas Turbine Pre-swirl System (가스터빈 프리스월 시스템의 외기 온도와 터빈 부하 조건에 따른 탈설계점 특성 분석)

  • Park, Hyunwoo;Lee, Jungsoo;Cho, Geonhwan;Cho, Jinsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.12
    • /
    • pp.881-889
    • /
    • 2019
  • The pre-swirl system is the device that minimizes energy loss of turbine cooling airflow from the stationary parts into rotating parts. In this paper, an off-design analysis was conducted for the ambient air temperature and turbine load conditions. The discharge coefficient was constant for ambient air temperature and turbine load. However, adiabatic effectiveness was increased. This is due to the volume flow rate. The volume flow rate was increased at higher ambient temperature and higher turbine load. It means that the volume of cooling air was increased and the cooling performance of the air was improved. Consequently, adiabatic effectiveness increased by 30.46% at 100% turbine load compared to 20% turbine load. And increased by 18.42% at 55℃ ambient air temperature compared to -20℃ ambient air temperature.

Study on Rainfall infiltration Characteristics for Weathered Soils: Analysis of Soil Volumetric Water Content and Its Application (국내 풍화토의 강우 침투특성 분석을 위한 실험연구: 토양 체적함수비 분석 및 적용성 평가)

  • Kim, Man-Il;Chae, Byung-Gon;Cho, Yong-Chan;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • v.18 no.1
    • /
    • pp.83-92
    • /
    • 2008
  • In order to analyze infiltration characteristics of rainfall in soil, two laboratory experiments were conducted using an amplitude domain reflectometry (ADR) sensor and a pore water pressure meter (PWP) in this study. The first experiment is to understand the dependency of volumetric water content and temperature for standard sand and weathered granite soil. The second experiment is a laboratory flume test with changes of rainfall condition. As the results of the dependency experiment, the volumetric water content is increased with increase of the output voltage measured by the ADR sensor in both the standard sands and weathered granite soil. Furthermore, the results also indicate necessity of consideration of the temperature dependency under the condition of high volumetric water contents from 0.15 to 0.45. In the flume test, two measurement devices are detected to the variation of volumetric water content and pore water pressure at the installation point of the flume. In especial, the measured values of ADR4 and PWP3 installed on the lower part of slope are higher than those of the others. It means that the lower part of slope plays a role of a runoff face and a beginning point of slope failure.

밀봉수주입 열교환기의 비정상 열전달 특성

  • 장근선;진승령;손용수
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.352-357
    • /
    • 1995
  • 원자력발전소 화학 및 체적제어계통의 일부인 밀봉수주입계통은 원자로 냉각재펌프 밀봉장치로 일정한 온도 범위의 밀봉수를 공급하여 밀봉장치의 건전성 및 원자로 냉각재 계통의 압력경계를 유지한다. 그러나 발전소 과도상태시 밀봉수 주입온도가 허용범위를 벗어나게 되면 온도조절기 폐쇄신호에 의해 밀봉장치로의 밀봉수 주입이 차단될 수 있다. 본 연구에서는 발전소 과도시에도 밀봉수 주입이 지속적으로 가능한 설계개선 방안으로 밀봉수주입 열교환기 주위에 우회라인을 설치하는 방안을 제시하고 밀봉수주입 열교환기 내에서의 비정상 열전달 현상을 수치해석을 이용하여 분석하였다. 계산은 속도장을 정상 상태인 power-law분포로 가정하고 시간 t=0에서 입구온도가 급격히 변하는 과도시 우회 유량 및 시간 변화에 대한 온도분포, 국부 Nusselt 수, 평균온도 등을 구하였다.

  • PDF

Characteristics on the Thermal and Fluid Flow in the Rectangular Aquarium Basin by Using PIV (PIV를 이용한 사각수조 내의 온도와 유체 유동 특성)

  • Kim, B.H.;Konar, Dibyendu;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.31-38
    • /
    • 2005
  • 육상 수조식 양식장은 해수를 끌어들여 어류를 기르는 데 사용된다. 본 연구는 사각 수조 내의 다양한 기하학적 관계와 유동에 대한 유동 특성을 도출하였다. 수치해석은 유한 체적법과 SIMPLE 기수법은 수치해석법을 활용하였으며, 비압축성 유체와 3차원 표준 $k-{\varepsilon}$난류 모델을 적용하였다. 속도 분포, 온도 분포에 대한 정보를 확보하였다. 실험과 수치해석의 결과가 정성적으로 잘 일치함을 보였다. 양식장의 깊이가 증가함에 따라 바닥 쪽의 유동이 더욱 안정됨을 확인하였다. 이는 각종 배설물 등의 정체현상으로 연결될 수 있음을 확인하였다. 수조내의 온도는 유입구의 초기 온도가 중요하며, Re 수가 증가할수록 온도는 상승하고 유입구의 반대 벽면 근처의 온도가 유입구 보다 증가함을 알 수 있었다.

  • PDF

Multi Zone Fuel Model for CANDU Reactor (CANDU 원자로용 다영역 핵연료모델)

  • 전용준;오세기;정근모
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1993.11a
    • /
    • pp.109-109
    • /
    • 1993
  • CANDU 원자로 지역별 대표 핵연료봉 1개에 대하여 열행태를 해석할 수 있는 '평균 단일 핵연료(ASF : Averaged Single Fuel)' 모델을 우선 제안하였다. 핵 연료봉 하나를 12 개 동일 체적의 환형 격자로 나누고 시공간을 고려하는 전진 유한 미분 해석을 적용하여 핵연료봉내에서의 열적 변이를 모사 하였다. 핵연료의 전도도 및 비열은 온도에 종속함이 가정되었다. 주어진 열출력에 대하여, 핵연료와 피복관내의 정상상태 온도분포를 산출하였고 주어진 냉각재 온도 및 표면 열 전달 계수에 대하여 핵연료봉 단위 길이당 저장열을 계산하였다. 초기 온도 분포의 임의 값에 대하여, 시간 단계별 열출력 및 열전달 계수 변이에 따른 저장열, 온도 분포, 냉각재료의 출력과 피복관 온도 변이를 계산하였다. 이후 ASF 모델을 CANDU 14개 지역 출력 특성의 실제적 모사 및 해석이 가능하도록, 14개 지역 대표 핵연료봉모델 모두를 동시에 포함하는 '다영역 핵연료(MZF : Multi Zone Fuel)' 모델로 확장하였다.

  • PDF

Study on Deformation of Miniature Metal Bellows in Cryocooler Following Temperature Change of Internal Gas (내부 기체의 온도 변화에 따른 극저온 냉각기용 소형 금속 벨로우즈의 변형에 관한 연구)

  • Lee, Seung Ha;Lee, Tae Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.4
    • /
    • pp.429-435
    • /
    • 2015
  • A bellows is an important temperature control component in a Joule-Thomson micro-cryocooler. It is designed using a very thin shell, and the inside of the bellows is filled with nitrogen gas. The bellows is made of a nickel-cobalt alloy that maintains its strength and elastic properties in a wide range of temperatures from cryogenic to $300^{\circ}C$. The pressure of the gas and the volume within the bellows vary according to the temperature of the gas. As a result, the bellows contracts or expands in the axial direction like a spring. To explore this phenomenon, the deformation of the bellows and its internal volume must be calculated iteratively under a modified pressure until the state equation of the gas is satisfied at a given temperature. In this paper, the modified Benedict-Webb-Rubin state equation is adopted to describe the temperature-volume-pressure relations of the gas. Experiments were performed to validate the proposed method. The results of a numerical analysis and the experiments showed good agreement.

The Physical Properties of -uffed Snacks (ppeongtuigi) Added with Sweet Potato Flours (일반 고구마 분말을 첨가한 팽화과자(뻥튀기)의 이화학적 특성)

  • Cheon, Seon-Hwa;Eun, Jong-Bang
    • Journal of Applied Biological Chemistry
    • /
    • v.54 no.3
    • /
    • pp.147-152
    • /
    • 2011
  • The physical properties of puffed snack by pellet with sweet potato flour, brown rice flour and wheat flour were evaluated at different moisture content, puffing temperature, and puffing time. The sweet potato pellets were tempered to 14, 16, and 18% moisture content and were puffed at 233, 238, and $243^{\circ}C$ for 4, 5 and 6 s. The whitness ($L^*$) value decreased as the heating temperature and time increased. The redness ($a^*$) and yellowness ($b^*$) values increased with increasing heating temperature and time. The specific volume of sweet potato puffed snacks showed an increasing trend with higher puffing conditions. The hardness of sweet potato puffed snacks increased as heating time and heating temperature increased. The sweet potato puffed snacks prepared with increasing moisture content (18%), heating times (6 s), and heating temperatures ($243^{\circ}C$) were awarded the highest scores for most of the sensory attributes and hence declared as best sweet potato puffed snacks.

The AC Arc Model of the High-Intensity Discharge Lamps (고광도 방사등의 교류 아아크 모델)

  • Chee, Chol-Kon;Kim, Hoon
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.2 no.3
    • /
    • pp.47-58
    • /
    • 1988
  • 본 논문에서는 고광도방전등의 전기적 특성을 해석하기 위한 아아크모델을 제시하였다. 방전관내에서 반경방향의 온도분포가 포물선형태로 변화하는 것으로 가정하고 방전관의 단위체적에서의 에너지평형식을 단면적에 대해 적분함으로서 단위길이당의 에너지평형식으로 변환하였다. 이 에너지평형식과 회로방정식, 그리도 오옴의 법칙을 이용하여 아아크의 전류와 전압의 1주기에서의 변화를 계산하여 좋은 결과를 얻었다. 또한 방전관의 축온도와 이에 따른 방사에너지의 값을 계산하는 간단한 방법을 제시하였다.

  • PDF

분말단조 해석을 위한 다공질 합금강 프리폼의 고온 업셋

  • Kim, Gi-Tae;Jo, Yun-Ho
    • Transactions of Materials Processing
    • /
    • v.1 no.2
    • /
    • pp.14-19
    • /
    • 1992
  • 분말단조 공정의 해석을 위한 기초연구로서 고용 업셋에 의한 다공질 합금강 프리폼의 치밀화와 소성 변형거동에 관하여 조사하였다. 다공질 프리폼의 소성 유동응력은 용도의 상승에 떠라 감소하였고, 변형속도의 증가에 따라 증가함을 보였다. 또한, 다공질 프리폼의 초기밀도가 더 높을수록 동일한 온도와 하중조건에서 더 높은 치밀화를 보였다. 또한, 밀도변화에 따른 프와송 비를 실험치로 부터 구하였고, 배불림 현상과 체적변화를 고려하여 온도에 따른 진응력-진변형률 관계를 구하였다.

  • PDF

Thermal analysis of concrete dam considering placing interval (타설 간격을 고려한 콘크리트 댐의 수화열 해석특성)

  • Chu, In-Yeop;Jang, Bong-Seok;Kim, Jin-Keun;Park, Byung-Kook
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.385-386
    • /
    • 2009
  • The temperature crack of concrete structure is caused by the phenomenon which the concrete volume is restricted in the inside or outside part due th the temperature variations induced by the hydration heat of cement. And mass concrete structures are weak in temperature crack. This study performed the hydration heat analysis of Seongdeok dam to analyze the hydration heat according to different interval of placement.

  • PDF