A Study on Measurement for Earth Resistance of Steel Structure (철탑접지저항 측정에 관한 연구)

  • 박석탁;김시영
    • 전기의세계
    • /
    • v.22 no.6
    • /
    • pp.33-51
    • /
    • 1973
  • To lower the earth resistance shall be one of the most effective method for the prevention of lightening damage on power transmission line. In this report, in order to investigate various characteristic necessary to lowering the earth resistance, the following experiments have been made at 154KV U1San-PoHang T/L, 154KV YoSu-SoonChun T/L and so on. 1. Measurement of Earth specific resistance, 2. Efficiency of Earthing of concrete foundation for steel structure., 3. Efficiency of Earthing with counter poise., 4. Compound impulse test with foundation of steel structure and counter poise. With the above investigate a guidance have been prepared for the effective work-performance of steel structure.

  • PDF

송전선 가선시 장력 및 이도설계 전산화

  • 김정부
    • 전기의세계
    • /
    • v.26 no.2
    • /
    • pp.14-18
    • /
    • 1977
  • 송전선의 굵기에 따라, 지지물의 높이를 결정하기 위하여 종단도를 그릴때마다 이도설계를 하여야 한다. 같은 전선이라도 온도에 따라, ruling span에 따라, 풍압 및 피빙의 부착여하에 따라 장력이 다르게 된다. 철탑설계시에 고온계, 저온계의 최대장력을 계산하여야 한다. 가선시에는 온도별 span별로 이도표를 만드러야 한다. 특히 복도체가선시에는 이도표를 만들어 가선하여야 된다. 이러한 계산은 computer에 의하면 많은 시간을 절약할 수 있으며 정확한 게산을 할 수 있다. 본고는 이러한 목적에 맞는 computer program에 대하여 설명하고저 한다.

  • PDF

A Development of Arcing Horn for Distribution Line Towers (배전철탑용 아킹혼 개발)

  • Cho, Hyun-Seob;Ryu, In-Ho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.11a
    • /
    • pp.172-175
    • /
    • 2006
  • Owing to the strike of lighting a breakage of insulator would happen. This breakage may give rise to many problems such as increment of reclosing failure, a drop for reliance and a hardship of maintenance and repair. To solve those problems, this study develop a protected equipment for insulator which is suitable to 22.9kV distribution line towers and is purposed to investigation for a proper adaption, protection efficiency of insulator and effect of adaption.

  • PDF

EHV lines In the Federal Republic of Germany (서독내의 초고압송전선로)

  • 이재숙
    • 전기의세계
    • /
    • v.19 no.6
    • /
    • pp.31-38
    • /
    • 1970
  • 본문은 IEEE지 1970년월호 Spectrum에 나타난 서독내의 초고압송전선로에 관한 (Mr. J. Jansen)소개문으로서 철탑선로 및 애자설계에 서독기술자가 깊은 검토를 하여 서독에 알맞는 이상적인 송전망을 건설하여 왔다는 것이다. 현재 우리나라도 345kV 초고압송전망을 가까운 장래에 건설하고저 만반의 준비를 갖추고 있는 중이다. 따라서 서독의 초고압송전망에 관한 기사는 협소한 국토등 여건이 비슷한 우리에게 큰 참고가 될 부분이 많음으로 본지에 이것을 번역하여 관계기술자의 설계참고자료로 제공하고저 한다.

  • PDF

Reserch on Wind Fressure Criteria of the Transsmision Tower (송전용 철탑 풍하중 설계기준에 관한 연구)

  • Byung, Gang;Min, Byeong-Wook;Shin, Tai-Woo;Wi, Hwa-Bok;Pak, Jai-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.20-22
    • /
    • 2003
  • This paper focuses on the effects of wind pressure on transmission towers. It recommends the need for an application method to strengthen some existing towers, especially those in areas regularly affected by typhoons, and to be applied to new constructions. Some considerations taken into account were modifying existing towers exposed, which can cause significant damage to the power system and the effects of damage on third parties.

  • PDF

Study and Adaptation of FM CP-Ring Antenna Radiation Pattern Transmission Facility (철탑의 반사 효과에 따른 FM CP-Ring 안테나의 방사 패턴 고찰 및 현장 적용 방안)

  • Choi, Soocheol;Cho, Kiryang
    • Journal of Broadcast Engineering
    • /
    • v.21 no.3
    • /
    • pp.404-411
    • /
    • 2016
  • In this paper, we investigate the radio wave radiation pattern to measure the actual field strength for the transmission antenna dipole antenna and the CP-ring antenna being used in our country as FM station, and the comparison was for field application. Compare results, If the transmitting station and the relay station which is located in the middle of a service area has been a useful CP-dipole antenna (four directions). CP-ring antenna having a directivity because the reflection effect of the tower was able to adjust the orientation to prevent the spread of menstrual another service area in the main direction was able to radiate high propagation 5~9dB. Especially, If the transmitting station and the relay station is located on one side of the service area for radiating radio waves in three directions by using the CP-ring antennas focus the orientation of the antenna in populated areas and road area can improve the broadcast reception environment.

A Safety Analysis of Electric Detonator for Stray Currents by Domestic Transmission Network System (국내 송전계통별 미주전류에 의한 전기뇌관의 안전성 분석)

  • Park Hyun-Sik;Kim Young-Seok;Kang Choo-Won
    • Tunnel and Underground Space
    • /
    • v.15 no.4 s.57
    • /
    • pp.296-304
    • /
    • 2005
  • This study is to observe stray currents generated around the steel tower by domestic transmission network system and analysis stability of electric detonator. It is measured the stay current of each ten place at steel tower of 765 kV, 345 tV, 154 tV transmission line among domestic transmission network system. Stay currents measured a total of 40m at intervals of 4m toward a line direction and a line vertical direction centering around steel tower. Temperature of the surface, EC, water content also are measured. Although stay currents show the highest values, that is 12 percent of at 4m and less than 1 percent of 40m with Institute of Makers of Explosives(IME) regulations. It is shown correlation between stay currents and water content$\cdot$EC$\cdot$temperature of the surface. Stay currents measured at line direction and line vertical direction were little different and the shape of diminution was also shown a similar aspect.

An Actual Case of Installing Interphase spacers to Prevent 154kV Transmission Line Galloping (154kV 송전선로 갤로핑 현상 분석 및 대책 사례)

  • Song, Ho-Seung;Lee, Cheong-Han;Yoon, Hyung-Hee;Jeon, Kwang-Sig
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.83-86
    • /
    • 2005
  • 최근 가공 송전선로 건설에 대한 인근 지역주민들의 반대에 부딪쳐, 불가피하게 가옥이 밀집된 주거지역을 우회하거나 토지 활용도가 낮은 산악지를 이용하여 선로를 건설하는 경우가 대부분이다. 이와 같이 경과지의 제한성으로 인해 때때로 국지적인 기상현상 발생 우려가 있는 지역에 불가피하게 송전선로를 건설하는 경우가 있으며, 이상기상 현상이 발생하는 11월말에서 3월초 사이에 경기북부 지역의 국지성 돌풍에 의해 갤로핑(Galloping)현상이 종종 발생되었다 갤로핑은 바람으로 인해 전력선이 횡진과 출렁임이 발생되는 현상을 말한다. 송전선로의 지지물에는 주로 철탑이 사용되고, 전력선은 ACSR 410mm 복도체가 주로 사용된다. 송전선로는 경제성과 계통의 안전성을 고려하여 수직배열로 2회선용 표준철탑을 사용한다. 갤로핑 현상은 바람에 의해 전력설에 심한 진동을 일으켜, 수직 배열된 전력선 상간 단락 또는 전력선과 가공지선간의 지락으로 고장전류가 생기고, 고장전류에 의한 보호계전기 동작으로 선로가 트립(Trip)되며, 이로 인한 전력공급 중단이 발생된다. 또한 전력선의 기계적인 진동에 의하여 전력선의 단선 또는 지지물의 파손으로 영구고장을 일으킬 수도 있다. 본 논문에서는 경기북부지역의 산악지에 설치된 154kV 송전선로에서 산비탈면을 타고 오르는 상승 바람에 의한 갤로핑 사례를 국내 최초로 현장에서 촬영한 동영상 자료를 토대로 소개하고, 갤로핑 발생시 송전선로에 미친 영향 등 검토 결과를 설명하였다. 전력선에 생긴 아크 흔적을 토대로 전력선간의 단락이 발생했던 지점을 실제로 관측할 수 있었다. 최근 갤로핑으로 인한 상간 단락 고상 방지론 목적으로 개발된 폴리머 상간스페이서(Interphase spacer)의 시공 사례를 소개하고, 현재까지 상간스페이서가 설치된 송전선로의 점검 결과를 소개하고자 한다.

  • PDF

The Failure Standard to Estimate the Behavior and Bearing Capacity for Connected-type Foundation of Transmission Tower in Clay (점토지반에 근입된 송전철탑 연결형 기초의 거동 특성 및 지지력결정을 위한 파괴기준)

  • Kyung, Doo-Hyun;Lee, Jun-Hwan;Paik, Kyu-Ho;Kim, Dae-Hong
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.3
    • /
    • pp.27-40
    • /
    • 2011
  • In this study, we performed model lateral load test for connected-type foundations of transmission tower with bar in clay, and proposed failure standard and measuring method to estimate ultimate lateral bearing capacity. For this study, we performed model lateral load tests in Iksan, Jeollabukdo and analyzed load-displacement characteristic of the model. We manufactured model foundation of transmission tower connected with bar and that considered a change of rigidity. We installed various measuring sensors to find general foundation behavior. From the test results, we measured, compared and analyzed load capacities, and then proposed failure standard to estimate bearing capacity for connecting type foundation.

Electrical and Mechanical Noise Study of the 765kV Transmission Line (765kV 송전선로의 전기적 및 기계적 소음고찰)

  • Lee,
    • Journal of KSNVE
    • /
    • v.6 no.1
    • /
    • pp.89-95
    • /
    • 1996
  • If the transmission line voltage is greater than 500kV, audible noise (AN) and hum noise (HN) due to corona discharges on the conductor would be an important design factor for the conductor selection of transmission line. Also there is an aeolian noise: wind noise(WN) from the tower and the conductor due to wind. This paper presents the results of a statistical analysis of audible noise, hum noise, aeolian noise of 6-480mm$^{2}$ conductor bundle in KEPRI 765kV Test Transmission Line which was constructed to develop 765kV double circuit AC transmission line for the first time in the world. The result of the analysis shows that 6-480mm$^{2}$ conductor bundle and tower satisfy configuration the audible noise design criterion of 50dB(A).

  • PDF