• Title/Summary/Keyword: 철근 좌굴

Search Result 46, Processing Time 0.019 seconds

Seismic Performance of Circular RC Columns Retrofitted Using Ductile PET Fibers (고연성 PET 섬유로 보강된 철근콘크리트 원형 기둥의 내진성능)

  • Vachirapanyakun, Sorrasak;Lim, Myung-Kwan;Choi, Dong-Uk
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.3
    • /
    • pp.289-298
    • /
    • 2016
  • An experimental research was performed using fibers for the purpose of retrofitting existing reinforced concrete circular columns. Glass fiber (GF) and polyethylene terephthalate (PET) were used as well as combined GF+PET (HF). PET has high tensile strength (over 600 MPa) and high ductility (about 15%), but has very low elastic modulus (about 1/6 of GF). A total of four columns was tested against laterally applied reverse cyclic load: control column, GF-, PET-, and HF-strengthened columns. All columns retrofitted using fibers demonstrated improved moment capacity and ductility. Moment capacity of GF-, PET-, and HF-strengthened columns was 120%, 107%, and 120% of the control column, respectively. Drift ratio of all retrofitted columns also increased by 63 ~ 83% over the control column. The final failure mode of the control column was main bar buckling. The final failure mode of the GF- and HF-strengthened columns was GF rupture while that of the PET-strengthened column was main bar rupture in tension. No damage was observed for PET at the ultimate stage due to excellent strain capacity intrinsic to PET. Current test results indicate that PET can be effectively used for seismic retrofit of RC columns. It is noted that the durability characteristics of PET needs to be investigated in the future.

An Experimental Study on the Structural Behavior of Steel Grid Shear Wall subjected to Axial Force and Cyclic Lateral Load (축력과 반복수평력을 받는 격자강판 내진보강벽의 구조거동에 관한 실험적 연구)

  • Park, Jung Woo;Sim, Ki Chul;Park, Jin Young;Lee, Young Hak;Kim, Heecheul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.6
    • /
    • pp.525-532
    • /
    • 2012
  • The recently constructed buildings are ensuring seismic safety with enhanced design criteria. But, the buildings unapplied enhanced design criteria are very weak. In this study, steel grid shear wall is proposed as a solution of seismic retrofit to ensure safety of the existing buildings for the earthquake. And the structural performance experiments were carried out under axial force and cyclic lateral loads. The two specimens were made of a reference RC frame and steel grid shear wall in-filled RC frame. The test setup configured with two dynamic actuators, for the axial force with a 500kN capacity actuator and for the cyclic lateral load applied with the 2,000kN actuator. Compared with control specimen, the strength, stiffness, ductility, energy dissipation capacity of the seismic retrofit structures is evaluated.

Analysis of Lateral Retrofitting Effect by FRP and BRB for Beam-column Element Joint of Low-Rise Piloti Buildings (FRP시트와 비좌굴가새를 적용한 저층 필로티 구조물의 보-기둥 연결부 거동 해석에 관한 연구)

  • Kim, Min-Sook;Yoon, So-Hee;Lee, Young-Hak;Kim, Hee-Cheul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.69-77
    • /
    • 2009
  • The experiment was carried out to investigate lateral retrofitting effects by FRP and BRB (Buckling-Restrained Brace) for beam-column elements. These results were utilized to establish an analytical model using commercial nonlinear analysis software, PERFORM3D. Concrete and steel analytical models previously proposed by several scholars were adopted for this analytical study. A proposed analysis model showed reasonable accuracy compared with the test results on the beam-column elements strengthened FRP sheets and BRB, as well as with the non-strengthened element subjected to lateral cyclic loadings. Subsequently, the proposed modeling technique for nonlinear analysis would be helpful for preliminary analyses for retrofitting structures, by enabling engineers to estimate the improved capacity of retrofitted structural elements before performing construction.

Large Displacement Behaviors of Foam-Insulated Concrete Sandwich Panels Subjected to Uniform Pressure (등분포하중에 종속된 폼내장 콘크리트 샌드위치패널의 유한변위거동)

  • Kang, Jun-Suk;Won, Deok-Hee;Kang, Young-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.4
    • /
    • pp.35-43
    • /
    • 2011
  • This study examined the structural behaviors of foam insulated concrete sandwich panels subjected to uniform pressure. Finite element models were used to simulate the detailed shear resistance of connectors and the nonlinear behaviors of concrete, foam and rebar components. The models were then validated using data from static tests performed at the University of Missouri. Both composite and non-composite action had a significant effect on the response of the foam insulated concrete sandwich panels, indicating that the simulated shear tie resistance should indeed be incorporated in numerical analyses. The modeling approach used here conveniently simulated the structural behaviors during all loading stages (elastic, yielding, ultimate and post-failure) and was compatible with the American Concrete Institute (ACI) Code and existing design practices. The results of this study will therefore provide useful guidelines for the analysis and design of foam insulated sandwich panels under both static and dynamic loadings.

A Study on the Composite Behavior of Steel-Concrete with Slip Anchor (슬립앵커를 이용한 강-콘크리트 합성 거동 연구)

  • Won, Deok-Hee;Han, Taek-Hee;Kim, Seung-Jun;Han, Seung-Ryong;Kang, Young-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.2
    • /
    • pp.7-12
    • /
    • 2011
  • Presently, composite method for steel and concrete is often used the stud. Steel properties of composite column could be changed by increasing of welding. The changed properties is possibly to cause local-buckling. Composite column had a large effect by slip instead of pull-out force in comparison composite girder. Improvement of adhesive force had effect by contact area rather than height of stud in composite column. This paper proposed new type of stud and analyzed performance through experimental study. This method would be effect steel structure with curvature.

Seismic Behavior of a Five-story RC Structure Retrofitted with Buckling-Restrained Braces Using Time-dependent Elements (시간종속요소를 이용한 5층 RC건축물의 비좌굴가새 보강에 대한 내진거동)

  • Shin, Ji-Uk;Lee, Ki-Hak;Lee, Do-Hyung;Jeong, Seong-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.6
    • /
    • pp.11-21
    • /
    • 2010
  • This study presents seismic responses of 5-story reinforced concrete structures retrofitted with the buckling-restrained braces using a time-dependent element. The time-dependent element having birth and death times can freely be activated within the user defined time intervals during the time history analysis. The buckling-restrained brace that showed the largest energy dissipation capacity among the test specimens in previous research was used for retrofitting the RC buildings in this study. It was assumed that the first story of the damaged building under the first earthquake was retrofitted with the buckling-restrained braces considered as the time-dependent element before the second of the successive earthquakes occurs. Under this assumption, this paper compares seismic responses of the RC structures with the time-dependent element subjected to the successive earthquake. Subjected to the second earthquake, it was observed that activation of the BRB systems largely decreases deformation of the moment frame where the damage was concentrated under the first earthquake. However, damages to the shear wall systems were increased after activation of the BRB systems. Since the cumulative damages of the shear wall systems were infinitesimal compared with the retrofit effect of the moment frame, the BRB system was effective under the successive earthquake.