• Title/Summary/Keyword: 철근의 영향

Search Result 939, Processing Time 0.028 seconds

Finite Element Analysis on Heat of Hydration with Reinforcing Steel Bars (철근의 영향을 고려한 수화열 유한요소해석)

  • Yoon Dong-Yong;Yang Ok-Bin;Min Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.1 s.85
    • /
    • pp.43-49
    • /
    • 2005
  • In the concrete structures, the magnitude and distribution of the temperature due to the heat of hydration are related to the thermal properties of each component composed of the concrete, the initial temperature, the type of formwork, and the ambient temperature of exposed surfaces. Even though the reinforcing steel bar has completely different thermal properties, it has been excluded. In the thermal analysis on the concrete structures. In this study, finite element analysis was performed on the concrete structures including the reinforcing steel in order to investigate their effect on temperature and stress distribution due to the heat of hydration. As the steel ratio increased, the maximum temperature and the internal-external temperature difference decreased by 32.5% and 10%, respectively. It is clear that the inclusion of reinforcing steel bars on the heat of hydration analysis is indispensable to obtain realistic solutions for the prediction of the maximum temperature and stresses

Evaluation on Moment-Curvature Relations and Curvature Ductility Factor of Reinforced Concrete Beams with High Strength Materials (고강도 재료를 사용한 철근콘크리트 보의 모멘트-곡률관계 및 곡률연성지수 평가)

  • Lee, Hyung-Joon
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.283-294
    • /
    • 2013
  • The high strength materials have been more widely used in reinforced concrete structures, specially, the reinforcing steel is permitted to used in RC structures up to yielding strength of 600 MPa. The strength of materials in RC beam section effects on the behavior and ductility of the RC members. In this study, the numerical analysis has been conducted to obtain the complete moment-curvature relation and the curvature ductility factor for the rectangular RC beams sections under the various reinforcement conditions and the effects of concrete strength, yield strength of reinforcement steel on the behavior and the curvature ductility factor of RC beam sections have been evaluated. The compressive strength of concrete and yield strength of steel have effected in various manner on the behavior and the curvature ductility factor of RC beam sections under reinforcement conditions. In the case of beam sections with equal resisting moment. the curvature ductility factor of RC beam section decreased with an increase in the yield strength of steel and increased with an increase in the concrete strength. When the yield strength of steel increased from 400 MPa to 600 MPa, the curvature ductility factor reduced about 30% and as the concrete strength increased from 30 MPa to 70 MPa, the curvature ductility factor of RC beam section increased about 3 times.

Deformability of RC Beam-Column Assembles (철근콘크리트 보-기둥 접합부의 연성능력)

  • Lee, Jung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.193-196
    • /
    • 2008
  • This paper proposes a method to predict the ductility capacity of reinforced concrete beam-column joints failing in shear after the formations of plastic hinges at both ends of the adjacent beams. The current design code divides joints into two categories: Type 1 for structures in non seismically hazard area and Type 2 in seismically hazard area. While there are many researches related to joint shear strength in Type 1, those in regard to joint ductility capacity of Type 2 are scarce. This paper classified the ductility capacity of beam-column joints into column, joint panel, and beam deformability. Since a brittle failure such as shear or bond failure in the columns must be avoided, column deformability was calculated by elastic analysis. The plastic hinges of the adjacent beams affect joint deformability. Therefore, the prediction of joint deformability was calculated with consideration to the degradation of the diagonally compressed concrete due to the strain penetration.

  • PDF

Bucking Behavior of Slender Reinforced High-Strength Concrete Columns (고강도 철근콘크리트 기둥의 좌굴 거동에 관한 연구)

  • 김진근;양주경
    • Magazine of the Korea Concrete Institute
    • /
    • v.5 no.2
    • /
    • pp.129-139
    • /
    • 1993
  • 본 연구에서는 철근콘크리트 기둥의 거동을 예측하기 위하여 층상화 방법을 이용한 유한요소 해석방법이 제안되었다. 콘크리트의 강도와 철근비가 기둥의 극한강도와 거동에 미치는 영향을 규명하기 위하여 세장비가 10, 60, 100인 정방형 단면(80$\times$80mm)을 갖는 30개의 기둥에 대하여 실험을 수행하였다. 이때, 콘크리트의 강도는 25.5, 63.5, 86.2MPa로, 철근비는 1.98, 3.95%로 변화시켰다. 또한, 단부조건은 양단힌지로 하고, 편심량은 기둥은 양단에서 같은 방향으로 24mm로 동일하게 하였다. 본 연구에서 제안된 해석방법은 철근콘크리트 기둥의 거동을 잘 예측하며, ACI의 모멘트 확대계수법은 고강도 콘크리트 장주에 대해서는 안전측이 아닌 것으로 나타났다. 콘크리트의 강도가 기둥의 극한강도에 미치는 영향은 기둥의 세장비가 증가할수록 감소하였으며, 콘크리트의 강도가 커질수록 세장기둥의 좌굴파괴 가능성은 증가하였다. 또한, 철근비를 증가시킬 경우, 기둥의 축력이 최대가 될 때의 모멘트가 증가되었으며, 기둥의 극한강도 증가량은 단주보다는 장주에서 더 크게 나타났다. 철근비 증가에 의해 나타나는 이러한 기둥의 극한강도 증가량과 모멘트 증가량은 콘크리트의 강도가 커질수록 증대되었다.

Effect of Curing Solution and Pre-Rust Process on Rebar Corrosion in the Cement Composite (시멘트 복합체 내부 철근 부식에 양생 용액과 철근 사전 부식이 미치는 영향)

  • Du, Rujun;Jang, Indong;Lee, Hyerin;Yi, Chongku
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.2
    • /
    • pp.1-8
    • /
    • 2022
  • The corrosion of reinforcement is the main reason for the performance degradation of concrete structures. The pre-rusted parts of rebar in concrete structures are vulnerable to the corrosion, especially if the structure is exposed to wet or chlorinated environments. In this study, effects of different curing solution on corrosion behavior of the pre-rusted rebars in the cement composites were investigated. HCl(3%) and CaCl2(10%) solution were utilized to accelerate the pre-rust of the rebar, and each pre-rust condition rebar including reference (RE) were placed in mortar cylinder. Three kinds of samples then were cured in CaCl2 (3%) solution and tap water respectively for 120 days. Electrochemical polarization and half-cell potential measurement were used to monitor the influence of curing water on the corrosion behavior of pre-rusted steel bar in cement composite. The surface morphology and composition of corroded steel bar were analyzed by scanning electron microscope and energy dispersive X-ray diffraction. The results show that the corrosion rates of pre-rusted samples in both curing water are higher than that of non-pre-rusted samples. The corrosion rates of RE, CaCl2 and HCl pre-rusted samples in salt water were 8.14, 4.48, 13.81 times higher than those in tap water respectively, on the 120th day.

Behavior of Reinforced Concrete Members Having Different Steel Arrangements (철근의 배근 위치가 다른 철근콘크리트 부재의 거동 분석)

  • Lee, Jung-Yoon;Kim, Ji-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.6
    • /
    • pp.685-692
    • /
    • 2007
  • When the shear force governs the response of an RC element, as in the case of a low-rise shear wall, the effect of shear on the element's response is thought to be responsible for the 'pinching effect' in the hysteretic loops. However, it was recently shown that this undesirable pinching effect can be eliminated in the hysteretic load-deformation curves of a shear-dominant element if the steel grid orientation is properly aligned in the direction of the applied principal stresses. In this paper, the presence and absence of the pinching mechanism in the hysteretic loops of the shear stress-strain curves of RC elements was explained rationally using a compatibility aided truss model. The analytical results indicate that the pinching effect of the RC elements is strongly related to the direction of the steel arrangement. The area of the energy dissertation does not increase proportionally to the difference between the direction of the principal compressive stress and the direction of the steel arrangement.

An Experimental Study on the Flexural Capacity of RC Beams with High-Strength Reinforcement (고장력 철근이 배근된 RC보의 휨성능에 관한 실험적 연구)

  • Hong, Geon-Ho;Tak, So-Young;Jo, Jae-Yeol;Lee, Jae-Hun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.289-292
    • /
    • 2008
  • This paper studied experimentally on the structural performance and serviceability of RC beams with high-strength reinforcing bars. Following to the previous research, high-strength reinforcing bars have an negative effect on the deflection and crack depth. But, there are advantages about reducing amount of reinforcement than normal-strength reinforcing bars. So, the purpose of this paper is to analyze the effect of flexural performance on the beams with high-strength reinforcing bars. Three specimens were tested, and the main variable was the yield strength of the reinforcements; SD400, SD600 and SD700. Experimental results shows that the stiffness of members reduced when apply to high-strength reinforcement and equal reinforcement ratio. But the flexural strength of members increased to proportion to the strength and amount of reinforcement. Also, when high-strength reinforcement used, serviceability aspect do not appear to be affected because there is no change for crack number and maximum crack width.

  • PDF

An Experimental Study on the Deflection Estimation of RC Flexural Member by Corrosion of Reinforcement (철근 부식에 따른 철근콘크리트 휨 부재의 처짐 산정에 대한 실험적 연구)

  • Kim, Jee-Sang;Moon, Hyeong-Gab
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.2
    • /
    • pp.143-151
    • /
    • 2021
  • Flexural test of reinforced concrete beam with corroded reinforcement were performed to measure the deflection, curvature and cracking moment for various bar diameter and amounts of corrosion. The amounts of corrosion are varied from 0% to 10% by weight and the bar diameters are chosen as 10mm, 13mm, and 19mm. The changes in reinforcement diameter do not affect the flexural behaviors significantly according to this experiment. If the amounts of corrosion is greater than 2%, the deflection and curvature of the beam increased and the cracking moment decreased. It means that the lower amounts of corrosion does not result structural damage in flexural member significantly as in direct tensile test. A modification factor considering an effect of amounts of corrosion is proposed based on the experiment, which can be used to determine the deflection of reinforced concrete beam with corroded reinforcement.

The Bond Characteristics of Deformed Bars in Recycled Coarse Aggregates Concrete (RCAC) (순환골재 콘크리트와 이형철근의 부착 특성)

  • Jeon, Su-Man;Yun, Hyun-Do;Choi, Ki-Sun;You, Young-Chan;Kim, Keung-Hwan
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.165-173
    • /
    • 2008
  • One of the most important requirements for reinforced concrete constructions is the bond behavior between concrete and reinforcement. For practical application, it is very important to study bond behavior of reinforcing bars in recycled aggregate concrete (RAC). Thirty six pull-out tests were carried out in order to investigate the bond behaviour between recycled coarse aggregate concrete (RCAC) and deformed bars. RCA replacement ratios (i.e., 0%, 30%, 60% and 100%) and positions of deformed bar (i.e., vertical and horizontal position) were considered as variables in this paper. Each specimen was in the form of a cube, with edges of 150 mm in length and for the pull-out tests, a deformed bar, 13 mm in diameter, was embedded in the center of each specimen. Based on the test results, the bond strength between the RCAC and deformed bars were influenced by both RCA replacement ratios and positions of deformed bars. It was found that under the equivalent mix proportion (i.e., the mix proportions are the same, except for different RCA replacement ratios), the bond strength between the RCAC and the ribbed bar has no obvious relation with the RCA replacement ratio, whereas the positions of deformed bars have a significant effect on the bond behavior between the RCAC and deformed bars. Under the condition of same RCA replacement ratio, the specimen of horizontal reinforcement at upper position (HU type) appear considerably low bond stress.

An Experimental Study on the Shear Resistance of Dowel Bars (장부철근의 전단저항에 대한 실험적 연구)

  • 신장호
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.6
    • /
    • pp.216-223
    • /
    • 1995
  • This research is aimed to investigate the influence of the structural parameters on dowel action of reinforcing bars in reinforced concrete members. I~ollowing the previous research, $^{(3.6)}$ a total of forty two specimens were tested to scrutinize the dowel action of reinforcing bars. Concrete cover, reinforcing bar size and bar distance were taken as main test variables for constant compressive strength of concrete. ]+om the test results, the structural behavior of all specimens was almost linear up to failure load. It is seen that dowel force increases as concrete cover increases. Reinforcing bar size and bar distance hardly affects dowel force. It is found that the dowel forces obtained by this experimental research is relatively close to that of regression analysis results and White's equation.