• Title/Summary/Keyword: 채널 노이즈

Search Result 81, Processing Time 0.024 seconds

Speech extraction based on AuxIVA with weighted source variance and noise dependence for robust speech recognition (강인 음성 인식을 위한 가중화된 음원 분산 및 잡음 의존성을 활용한 보조함수 독립 벡터 분석 기반 음성 추출)

  • Shin, Ui-Hyeop;Park, Hyung-Min
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.3
    • /
    • pp.326-334
    • /
    • 2022
  • In this paper, we propose speech enhancement algorithm as a pre-processing for robust speech recognition in noisy environments. Auxiliary-function-based Independent Vector Analysis (AuxIVA) is performed with weighted covariance matrix using time-varying variances with scaling factor from target masks representing time-frequency contributions of target speech. The mask estimates can be obtained using Neural Network (NN) pre-trained for speech extraction or diffuseness using Coherence-to-Diffuse power Ratio (CDR) to find the direct sounds component of a target speech. In addition, outputs for omni-directional noise are closely chained by sharing the time-varying variances similarly to independent subspace analysis or IVA. The speech extraction method based on AuxIVA is also performed in Independent Low-Rank Matrix Analysis (ILRMA) framework by extending the Non-negative Matrix Factorization (NMF) for noise outputs to Non-negative Tensor Factorization (NTF) to maintain the inter-channel dependency in noise output channels. Experimental results on the CHiME-4 datasets demonstrate the effectiveness of the presented algorithms.

Evaluation of Image Quality According to Presence or Absence of Upper limbs in Scan Field of View During CT Examinations (Including LUNG MAN) (CT 검사 시 스캔 범위 내 상지 유무에 따른 영상의 질 평가(LUNG MAN 포함))

  • Zhang, Yuying;Zheng, Haoyang;Jung, Kang-gyo;Cho, Yu-Jin;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.567-573
    • /
    • 2017
  • The purpose of this study was to evaluate whether or not there was artifact when the upper limb could not be lifted to the top of the head during multi-detector computed tomography(MDCT) scans of the chest and abdomen. Contrast radiography of the human and chest phantom was performed with 128channal MDCT. Under the same conditions(120 kVp, 110 mAs, standard algorithm)both hands lifted up and put down each time in the human experiment. In the chest phantom experiment, the radiography was carried out when the upper limb phantom was adjusted at a certain distance(0, 3, 7 cm) from the chest phantom. Subsequently, the values of Noise, CT number, SNR, and CNR were measured in the field of concern. The noise value of fat, rib, and muscle increased when the arm was lifted in humans(0.79, 47.8, 27%). Furthermore, when the upper limb was lowered, the noise value of muscle and lung increased in the phantom(31.2, 9.4%). In addition, the noise value of the muscles and lung decreased by 5, 25.12% and 5.6, 15.35% as the upper limb moved about 0,3,7cm away from the chest. When the chest and abdominal radiography were performed, in the case of the presence of other parts outside the inspection area, the probability of artifact was minimal while the distance was more than 3cm away from the upper limb to the chest and abdomen.

Magnetic Flux Leakage Method based Local Fault Detection for Inspection of Wire Rope (승강기 와이어로프 진단을 위한 누설자속기법 기반 국부손상 진단)

  • Kim, Ju-Won;Park, Ju-Young;Park, Seunghee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.4
    • /
    • pp.417-423
    • /
    • 2015
  • In this study, Magnetic Flux Leakage(MFL)-based inspection system was applied to detect the local fault of wire rope. To verify the feasibility of the proposed damage detection technique, an 4-channel MFL sensor head prototype was designed and fabricated. A wire rope with several types of cross-sectional damages were fabricated and scanned by the MFL sensor head to measure the magnetic flux density of the wire rope specimen. To interpret the condition of the wire rope, magnetic flux signals were used to determine the locations of the flaws. To improve the resolution of signal, the instantaneous variation value of magnetic flux was utilized. Measured signals from the damaged specimen were compared with thresholds set for objective decision making. Finally, the results were compared with information on actual inflicted damages to confirm the accuracy and effectiveness of the proposed cable monitoring method.

Envelope Elimination and Restoration Transmitter for Efficiency and Linearity Improvement of Power Amplifier (전력증폭기의 효율 및 선형성 개선을 위한 포락선 제거 및 복원 송신기)

  • Cho, Young-Kyun;Kim, Changwan;Park, Bong Hyuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.3
    • /
    • pp.292-299
    • /
    • 2015
  • An envelope elimination and restoration transmitter that uses a tri-level envelope encoding scheme is presented for improving the efficiency and linearity of the system. The proposed structure amplifies the same magnitude signal regardless of the input peak-to-average power ratio and reduces the quantization noise by spreading out the noise to the out-of-band frequency, resulting in the enhancement of power efficiency. An improved linearity is also obtained by providing a new timing mismatch calibration technique between the envelope and phase signal. Implementation in a 130 nm CMOS process, transmitter measurements on a 20-MHz long-term evolution input signal show an error vector magnitude of 3.7 % and an adjacent channel leakage ratio of 37.5 dBc at 2.13 GHz carrier frequency.

Interference Aware Receiver Filtering for Wireless Ad Hoc Networks (무선 애드혹 네트워크에서의 간섭 제어 수신 기법)

  • Shin, Sungpil;Lee, Byungju;Park, Sunho;Shim, Byonghyo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.9-15
    • /
    • 2013
  • Recent works on ad hoc network study have shown that achievable throughput can be made to scale linearly with the number of receive antennas even if the transmitter has only a single antenna. In this paper, we propose a non-parametric linear minimum mean square error (MMSE) receiver for achieving further gain in performance when the channel state information at receiver (CSIR) of interferers is imperfect. The key feature to make our approach effective is to exploit the autocorrelation of the received signal. In fact, by incorporating the desired channel information on top of the observations including interference and noise only, the proposed method achieves large fraction of the optimal MMSE transmission capacity without transmission rate loss. From the SINR analysis as well as transmission capacity simulations in realistic ad hoc network system, we show that the proposed non-parametric linear MMSE receiver brings substantial performance gain over existing multiple receive antenna algorithms.

가스장 이온원 시스템에서 마이크로 채널 플레이트의 잡음 제거 방법

  • Han, Cheol-Su;Park, In-Yong;Jo, Bok-Rae;Park, Chang-Jun;An, Sang-Jeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.422.2-422.2
    • /
    • 2014
  • 가스장 이온원(GFIS: Gas Field Ionization Source)은 전자현미경보다 분해능이 향상된 이온현미경의 광원으로 사용하기 위하여 연구되고 있고, 큰 각전류 밀도, 작은 크기의 가상 이온원 그리고 좁은 에너지 퍼짐을 특징으로 한다. 여러 가지 장점을 가지고 있는 GFIS을 개발하기 위해서는 GFIS에서 발생된 이온빔의 형상을 관찰 것이 매우 중요하며, 이러한 관찰을 위한 시스템에는 주로 마이크로 채널 플레이트 (MCP: Micro Channel Plate)가 사용된다. MCP는 채널내부에 입사한 입자의 에너지에 의해서 생성된 이차전자를 수 천 배에서 수 백 만 배 이상 증폭시켜 형광판에 조사하고 발광시키는 방법으로 작은 신호를 영상으로 관찰 할 수 있도록 한다. MCP의 큰 증폭비는 작은 크기의 신호를 큰 신호로 증폭하여 관찰하는데 용이하여, GFIS 방법으로 생성된 이온빔(이온빔 전류 값은 pA 수준)을 관찰하기에 적합하다. 그러나 MCP를 이용하여도 증폭된 이온빔의 세기가 매우 작기때문에 생성된 이온빔 형상을 정확하게 관찰하기 위해서는 MCP의 형광판을 촬영하는 카메라 노출시간을 길게하여 데이터 수집 시간을 늘려야 하는 문제가 있다. 본 발표에서는 이온빔 형상 관찰에 소요되는 시간을 단축하기 위하여 MCP의 잡음이 GFIS의 이온빔 이미지 관찰에 미치는 영향을 분석하고 이를 제거 방법을 소개한다. 본 연구에서는 GFIS 방출 이온빔의 이미지에 포함된 MCP 잡음 특성을 장(전계)이온현미경 (Field Ion Microscope)실험을 통하여 분석하였고, 디지털 이미지 처리 방법을 이용하여 방출 이온빔 이미지에서 MCP 잡음을 제거하여 방출 이온빔 이미지만 추출할 수 있었다. 본 연구에서 제안한 방법을 GFIS 방출 이온빔 관찰시스템에 적용함으로써 기존 방법에 비해 노출시간을 단축하여 방출 이온빔을 관찰 할 수 있었으며, 노이즈 제거 효과로 향상된 이온빔 형상을 얻을 수 있었다. 본 연구결과의 관찰시간 단축과 향상된 이온빔 형상 획득은 이온현미경 개발에 필수적인 단원자 이온빔을 보다 효율적으로 개발할 수 있으며 디지털 이미지 처리로 GFIS 이온빔 생성을 자동화하는데 응용할 수 있다. 더불어 기존방법에 비해 이미지 획득을 위한 MCP의 노출시간을 단축할 수 있으므로 실험장비 수명 단축 방지 및 관리에 큰 장점이 있다.

  • PDF

A Design of CMOS Multi-Mode Baseband Filter with New Automatic Tuning (새로운 자동 튜닝 기능을 가지고 있는 CMOS 다중 모드 기저 대역 필터의 설계)

  • Lee Kang-Yoon;Ku Hyunchul;Hur Jeong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.2 s.344
    • /
    • pp.34-41
    • /
    • 2006
  • This paper presents a CMOS multi-mode baseband filter architecture to support PDC/GSM/EDGE/WCDMA and its new automatic tuning method. 5-th order Chebyshev low pass filter is designed for implementing the baseband channel-select filter. Capacitors and resistors were shared efficiently between modes to minimize the area. And, the new cut-off frequency tuning method is proposed to compensate the process variation. This method can reduce the area and the noise level due to MOS switches.

The Performance of a Non-Decision Directed Clock Recovery Circuit for 256 QAM Demodulator (256-QAM 복조를 위한 NDD 클럭복원회로의 성능해석)

  • 장일순;조웅기;정차근;조경록
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.1A
    • /
    • pp.27-33
    • /
    • 2000
  • Gardner’s algorithm is one of the useful algorithm for NDD(Non-Decision Directed) symbol synchronization in PAM communications. But the algorithm has a weak point such as pattern noises increasing in multi-level PAM. To insert a pre-filter in the algorithm is able to reduce timing jitter and pattern noise. In this paper, we analyze statistical properties of NDD algorithm to find an optimal parameter of the pre-filter for improving timing jitter and PLL locking. As a simulation result, optimum value of pre-filter parameter, $\beta$, is 0.3 and 0.5 at the roll off factor of the channel, $\alpha$, is 0.5 and 1.0, respectively. Optimum parameters of the pre-filter for clock synchronization of all-digital 256-QAM demodulator is shown in the results.

  • PDF

Performance of Equalizer Schemes in Power Line Communication Systems for Automatic Metering Reading (자동 원격검침을 위한 전력선 통신 시스템에서의 등화 기법 연구)

  • Kim, Yo-cheol;Bae, Jung-Nam;Kim, Jin-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.1
    • /
    • pp.29-34
    • /
    • 2011
  • In this paper, we propose and analyze the equalizer schemes, zero-forcing (ZF) and minimum mean square error (MMSE) in power line communication (PLC) system for automatic meter reading (AMR). For efficient implementation of AMR system with PLC, effects of impulsive noise and multipath channel should be mitigated. To overcome these effects, the above equalizer schemes are employed. System performance is evaluated in term of bit error rate. From simulation results, it is confirmed that the equalizer can significantly improve bit error rate (BER) performance in PLC system, and MMSE equalizer provides better performance than ZF scheme. The results of this paper can be applied to AMR system as well as various smart grid services using PLC.

A 3.125Gb/s/ch Low-Power CMOS Transceiver with an LVDS Driver (LVDS 구동 회로를 이용한 3.125Gb/s/ch 저전력 CMOS 송수신기)

  • Ahn, Hee-Sun;Park, Won-Ki;Lee, Sung-Chul;Jeong, Hang-Geun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.9
    • /
    • pp.7-13
    • /
    • 2009
  • This paper presents a multi-channel transceiver that achieves a data rate of 3.125Gb/s/ch. The LVDS is used because of its noise immunity and low power consumption. And a pre-emphasis circuit is also proposed to increase the transmitter speed. On the receiver side, a low-power CDR(clock and data recovery) using 1/4-rate clock based on dual-interpolator is proposed. The CDR generates needed additional clocks in each recovery part internally using only inverters. Therefore each part can be supplied with the same number of 1/4-rate clocks from a clock generator as in 1/2-rate clock method. Thus, the reduction of a clock frequency relaxes the speed limitation and lowers power dissipation. The prototype chip is comprised of two channels and was fabricated in a $0.18{\mu}m$ standard CMOS process. The output jitter of transmitter is loops, peak-to-peak(0.31UI) and the measured recovered clock jitter is 47.33ps, peak-to-peak which is equivalent to 3.7% of a clock period. The area of the chip is $3.5mm^2$ and the power consumption is about 119mW/ch.