• Title/Summary/Keyword: 창호(窓戶)

Search Result 4,172, Processing Time 0.051 seconds

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

Utility of Wide Beam Reconstruction in Whole Body Bone Scan (전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성)

  • Kim, Jung-Yul;Kang, Chung-Koo;Park, Min-Soo;Park, Hoon-Hee;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of $^{99m}Tc$-HDP administered but second group altered dosage of $^{99m}Tc$-HDP with 740 and 1,110 MBq (20 mCi and 30 mCi) in same scan speed. The acquired data was reconstructed using the typical clinical protocol in use and the WBR protocol. The patient's information was removed and a blind reading was done on each reconstruction method. For each reading, a questionnaire was completed in which the reader was asked to evaluate, on a scale of 1-5 point. Results: The result of planar WBR data improved resolution more than 10%. The Full-Width at Half-Maximum (FWHM) of WBR data improved about 16% (Standard: 8.45, WBR: 7.09). SPECT WBR data improved resolution more than about 50% and evaluate FWHM of WBR data (Standard: 3.52, WBR: 1.65). A clinical evaluation study, there was no statistically significant difference between the two method, which includes improvement of the bone to soft tissue ratio and the image resolution (first group p=0.07, second group p=0.458). Conclusion: The WBR method allows to shorten the acquisition time of bone scans while simultaneously providing improved image quality and to reduce the dosage of radiopharmaceuticals reducing radiation dose. Therefore, the WBR method can be applied to a wide range of clinical applications to provide clinical values as well as image quality.

  • PDF

Study the Analysis of Comparison with AROI and MROI Mode in Gated Cardiac Blood Pool Scan (게이트심장혈액풀 스캔에서 자동 관심영역 설정과 수동 관심영역 설정 모드의 비교 분석에 관한 고찰)

  • Kim, Jung-Yul;Kang, Chun-Koo;Kim, Yung-Jae;Park, Hoon-Hee;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.222-228
    • /
    • 2008
  • Purpose: The objectives of this study were to compare the left ventricle ejection fraction (LVEF) from gated cardiac blood pool scan (GCBP) for analysis auto-drawing region of interest mode (AROI) and manual-drawing region of interest mode (MROI), respectively. To evaluation the relationships between values produced by both ROI modes. Materials and Methods: Gated cardiac blood pool scan using in vivo method Tc-99m Red Blood Cell were performed for 33 patients (mean age: $53.2{\pm}13.2\;y$) with objective of chemotherapy using single head gamma camera (ADAC Laboratories, Milpitas, CA). Left ventricular ejection fraction was automatically and manually measured, respectively. Results: There was significant difference statistically between AROI and MROI ($LVEF^{AROI}$: $71.4{\pm}12.4%$ vs. $LVEF^{MROI}$: $65.8{\pm}5.9%$, p=0.003). Intra-observer agreements in AROI was higher than MROI ($\gamma^{AROI}=0.964$, Cronbach's $\alpha^{AROI}=0.986$ vs. $\gamma^{MROI}=0.793$, Cronbach's $\alpha^{MROI}=0.911$), either. Additionally, there was no significant difference statistically at best septal view (${\Delta}LVEF^{BSV}=0.7{\pm}2.3%$, p=0.233), however statistically significant difference was found at badly separated septal view (${\Delta}LVEF=10.9{\pm}11.4%$, p=0.001). Moreover, Intra-observer agreements in best septal view was higher than badly separated septal view ($\gamma^{BSV}=0.939$, Cronbach's $\alpha^{BSV}=0.978$; $\gamma=0.948$, Cronbach's $\alpha=0.981$ at AROI, $\gamma^{BSV}=0.836$, Cronbach's $\alpha^{BSV}=0.936$; $\gamma=0.748$, Cronbach's $\alpha=0.888$ at MROI). Conclusion: When best septal view was acquired, LVEF by AROI and MROI indicated not different. Comparing Intra-observer agreements with AROI and MROI, the AROI tended to show higher. Therefore, it is considered that the AROI than MROI is valuable in reproducibility and objective when ROI analysis by acquire left ventricular of best septal view.

  • PDF

A Comparative Study of the Standard Uptake Values of the PET Reconstruction Methods; Using Contrast Enhanced CT and Non Contrast Enhanced CT (PET/CT 영상에서 조영제를 사용하지 않은 CT와 조영제를 사용한 CT를 이용한 감쇠보정에 따른 표준화섭취계수의 비교)

  • Lee, Seung-Jae;Park, Hoon-Hee;Ahn, Sha-Ron;Oh, Shin-Hyun;NamKoong, Heuk;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.235-240
    • /
    • 2008
  • Purpose: At the beginning of PET/CT, Computed Tomography was mainly used only for Attenuation Correction (AC), but as the performance of the CT have been increase, it could give improved diagnostic information with Contrast Media. But it was controversial that Contrast Media could affect AC on PET/CT scan. Some submitted thesis' show that Contrast Media could overestimate when it is for AC data processing. On the contrary, the opinion that Contrast Media could be possible to affect the alteration of SUV because of the overestimated AC. But it does not have a definite effect on the diagnosis. Thus, the affection of Contrast Media on AC was investigated in this study. Materials and Methods: Patient inclusion criteria required a history of a malignancy and performance of an integrated PET/CT scan and contrast- enhanced CT scan within a 1-day period. Thirty oncologic patients who had PET/CT scan from December 2007 to June 2008 underwent staging evaluation and met these criteria. All patients fasted for at least 6 hr before the IV injection of approximately 5.6 MBq/kg (0.15 mCi/kg) of $^{18}F$-FDG and were scanned about 60 min after injection. All patients had a whole body PET/CT performed without IV contrast media followed by a contrast-enhanced CT on the Discovery STe PET/CT scanner. CT data were used for AC and PET images came out after AC. The ROIs drew and measured SUV. A paired t-test of these results was performed to assess the significance of the difference between the SUV obtained from the two attenuation corrected PET images. Results: The mean and maximum Standardized Uptake Values (SUV) for different regions averaged over all Patients. Comparing before using Contrast Media and after using, Most of ROIs have the increased SUV when it did Contrast Enhanced CT compare to Non-Contrast enhanced CT. All regions have increased SUV and also their p value was under 0.05 except the mean SUV of the Heart region. Conclusion: In this regard, the effect on SUV measurements that occurs when a contrast-enhanced CT is used for attenuation correction could have significant clinical ramifications. But some submitted thesis insisted that the percentage change in SUV that can determine or modify clinical management of oncology patients is small. Because there was not much difference that could be discovered by interpreter. But obviously the numerical change was occurred and on the stage finding primary region, small change would be base line, such as the region of liver which has greater change than the other regions needs more attention.

  • PDF

Bronchial Brushing and Bronchial Washing for Diagnosis of Central Lung Cancer (중심형 폐암 진단을 위한 기관지찰과술과 기관지세척술)

  • Park, Ki-Su;Park, Jae-Yong;Cha, Seung-Ick;Son, Ji-Woong;Kim, Kwan-Young;Kim, Jeong-Seok;Chae, Sang-Cheol;Kang, Tae-Kyong;Park, Tae-In;Kim, Chang-Ho;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.817-825
    • /
    • 1999
  • Background : Forceps biopsy, bronchial brushing, and bronchial washing are used in conjunction with bronchoscopy to provide specimens for histologic and cytologic analysis in patients with suspected lung cancer. This study was performed to evaluate how many times brushing should be done and how much fluid should be used during bronchial washing for increasing diagnostic yield, and to evaluate which combination of these procedures gives the highest diagnostic yield. Methods : Forty patients, with suspected lung cancer, who had bronchoscopically visible lesions were enrolled in this prospective study. During one bronchoscopic examination four forceps biopsies, four bronchial brushings, and bronchial washing were done in all patients. The patients were divided into four groups by the amount of normal saline used for bronchial washing; group I, 10 ml ; group II, 20ml ; group III 30ml, and group IV, 40ml. We analyzed the results in 36 patients confirmed as lung cancer. Results : The diagnostic sensitivity of bronchial washing before and after forceps biopsy and bronchial brushing were 36% and 28%, respectively. The cumulative diagnostic sensitivity of bronchial washing was 47% and significantly higher than that of bronchial washing before or after forceps biopsy and bronchial brushing (p<0.05). The diagnostic sensitivity of bronchial washing with saline of 30ml was significantly higher than that of bronchial washing with saline of 10ml or 20ml (p<0.05). The diagnostic sensitivity of the first brushing was 75%, the second brushing 78%, the third brushing 83%, and the fourth brushing 67%. With repeated brushing up to three times, the diagnostic sensitivity increased to 92% (p<0.05). However, inclusion of the fourth brushing did not give a further increase of the diagnostic sensitivity. The diagnostic sensitivity of forceps biopsy was 86%. The diagnostic sensitivities of forceps biopsy by the type of bronchial lesion were as follows: tumor, 88%; infiltration, 67%; infiltration with nodularity, 80%; and collapse, 100%. The combination of forceps biopsy and bronchial washing gave a diagnostic sensitivity of 89%. The diagnostic sensitivity of combining forceps biopsy with bronchial brushing was 97%. Addition of bronchial washing did not increase the diagnostic yield over forceps biopsy and bronchial brushing. Conclusion : In patients with central lung cancer, forceps biopsies and repeated brushings up to three times should be done for maximal diagnostic yield.

  • PDF

Gelatinization Properties of Starch Dough with Moisture Content, Heating Temperature and Heating Time (수분함량, 가열온도 및 가열시간에 따른 전분 반죽의 호화특성)

  • Lee, Boo-Yong;Lee, Chang-Ho;Lee, Cherl-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.428-438
    • /
    • 1995
  • The gelatinization properties of corn and waxy corn starch doughs were examined at various moisture contents, heating temperatures and heating times. The onset temperatures of gelatinization with 1% CMC using Brabender Amylograph were $64^{\circ}C$ for both corn and waxy corn starch. In the gelatinization properties using DSC, onset temperature$(T_o)$, maximum peak temperature$(T_p)$, completion temperature$(T_c)$ and enthalpy of the corn starch were $68.15^{\circ}C,\;74.01^{\circ}C,\;85.65^{\circ}C$ and $3.2\;cal/gram$ respectively. While those of the waxy corn starch were $68.24^{\circ}C,\;75.43^{\circ}C,\;93^{\circ}C$ and $4.2\;cal/gram$ respectively. In enzymatic analysis, when the moisture content increased from 36% to 52% and heating temperature from $60^{\circ}C$ to $100^{\circ}C$, the gelatinization degree of starch dough increased from about 10% to about 62%. The gelatinization degree of waxy corn starch dough was $15{\sim}20%$ higher than that of corn starch dough under the same gelatinization conditions. The regression equations of gelatinization degree (Y) of starch dough in the range of $36{\sim}52%$ moisture content $(X_1)\;60{\sim}100^{\circ}C$ heating temperature $(X_2)\;and\;0{\sim}2.0$ min heating time $(X_3)$ were examined using response surface analysis. The regression equation of corn starch dough was: $Y=28.659+8.638\;X_}+15.675\;X_2+7.770\;X_3-1.620\;{X_1}^2+10.790\;X_1X_2-4.220\;{X_2}^2+0.510\;X_1X_3+1.980\;X_2X_3-6.850\;{X_3}^2\;(R^2=0.9714)$ and that of waxy corn starch dough was: $Y=32.617+12.535\;X_1+20.470\;X_2+8.608\;X_3+4.093\;{X_1}^2+13.550\;X_1X_2-4.467\;{X_2}^2+1.560\;X_1X_3+2.160\;X_2X_3-9.527\;{X_3}^2$\;(R^2=0.9621)$. As the moisture content, heating temperature and heating time increased, the reaction rate constant(k) of gelatinization increased. The greatest reaction rate constant was observed at initial 0.5 min heating time of 1st gelatinization stage. At the heating temperature of $90^{\circ}C$, gelatinization of starch dough was completed almost in the initial 0.5 min heating time. The reaction rate constant of waxy corn starch dough was higher than that of corn starch dough under the same gelatinization conditions. At the 52% moisture content, the regression equation between reaction rate constant(k) and heating temperature(T) for corn starch dough was $log\;k=11.1140-4.1226{\times}10^3(1/T)$ (r=-0.9520) and that of waxy corn starch dough was $log\;k=10.1195-3.7090{\times}10^3(1/T)$ (r=-0.9064).

  • PDF

Prognostic Value of TNM Staging in Small Cell Lung Cancer (소세포폐암의 TNM 병기에 따른 예후)

  • Park, Jae-Yong;Kim, Kwan-Young;Chae, Sang-Cheol;Kim, Jeong-Seok;Kim, Kwon-Yeop;Park, Ki-Su;Cha, Seung-Ik;Kim, Chang-Ho;Kam, Sin;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.322-332
    • /
    • 1998
  • Background: Accurate staging is important to determine treatment modalities and to predict prognosis for the patients with lung cancer. The simple two-stage system of the Veteran's Administration Lung Cancer study Group has been used for staging of small cell lung cancer(SCLC) because treatment usually consists of chemotherapy with or without radiotherapy. However, this system does not accurately reflect segregation of patients into homogenous prognostic groups. Therefore, a variety of new staging system have been proposed as more intensive treatments including either intensive radiotherapy or surgery enter clinical trials. We evaluate the prognostic importance of TNM staging, which has the advantage of providing a uniform detailed classification of tumor spread, in patients with SCLC. Methods: The medical records of 166 patients diagnosed with SCLC between January 1989 and December 1996 were reviewed retrospectively. The influence of TNM stage on survival was analyzed in 147 patients, among 166 patients, who had complete TNM staging data. Results: Three patients were classified in stage I / II, 15 in stage III a, 78 in stage IIIb and 48 in stage IV. Survival rate at 1 and 2 years for these patients were as follows: stage I / II, 75% and 37.5% ; stage IIIa, 46.7% and 25.0% ; stage III b, 34.3% and 11.3% ; and stage IV, 2.6% and 0%. The 2-year survival rates for 84 patients who received chemotherapy(more than 2 cycles) with or without radiotherapy were as follows: stage I / II, 37.5% ; stage rna, 31.3% ; stage IIIb 13.5% ; and stage IV 0%. Overall outcome according to TNM staging was significantly different whether or not received treatment. However, there was no significant difference between stage IIIa and stage IIIb though median survival and 2-year survival rate were higher in stage IIIa than stage IIIb. Conclusion: These results suggest that the TNM staging system may be helpful for predicting the prognosis of patients with SCLC.

  • PDF

Contact dermatitis among male workers exposed to metalworking fluids (금속가공유를 취급하는 남성 근로자의 접촉피부염)

  • Jin, Young-Woo;Lee, Jun-Young;Kim, Eun-A;Park, Seung-Hyun;Chai, Chang-Ho;Choi, Yong-Hyu;Kim, Kyoo-Sang
    • Journal of Preventive Medicine and Public Health
    • /
    • v.30 no.2 s.57
    • /
    • pp.381-391
    • /
    • 1997
  • In an epidemiological study of metal workers exposed to metalworking fluids (MWF), the prevalence time of Evolution, seasonal occurrence and clinical type of contact dermatitis were investigated. Compostional analysis of MWF with HPLC, dermatological examination and two consecutive questionnaire surveys were conducted. Study population was divided into two groups ; workers contact to cutting oil and workers contact to rust preventive oil. In the analysis of MWF, aliphatic hydrocarbons, having 12-20 carbons, was most common composition(49.04%) of cutting oil otherwise, major contents (90.99%) of the rust preventives oil were aliphatic hydrocarbons composed of 6-9 carbons. The frequency (point prevalence) of contact dermatitis(CD) was 7(12.7 per 100 subjects) in the dermatological examination of 55 workers. As the result of second survey for contact dermatitis, cumulative prevalence of oil working full-time and recent 1 year prevalence in two groups were 28.0, 16.7 and 15.1, 12.5 per 100 subjects. There were no difference in the prevalence of CD by oil, age, oil contact duration. Summer is the most common evolution season in workers exposed to cutting oil, but not in workers exposed to rust preventive oil. Major clinical type of CD was erythematous papules in both groups. It presents the importance of preventive measures that 51.1% suffer from contact dermatitis had medical care at their own expense, and 47.1% of them felt serious about their contact dermatitis. From the fact that 68.6% think cotton gloves protective apparatus, we emphasize the need for health education.

  • PDF

Comparison of Growth Charateristics, Forage Yield and Growth Analysis in Corn Hybrids for Silage Production (Silage용 옥수수의 생육특성, 수량 및 생육해석의 품종간 비교)

  • 김창호;박상철;이효원;강희경
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.18 no.2
    • /
    • pp.79-88
    • /
    • 1998
  • This experiment was conducted from May to August in 1997 to selected the wrn hybrids being suitable for silage at farm in the Kongju National University through the comparison of growth characteristics, forage yield and growth analysis about native and imported corn hybrids for silage production. In this experiment, trial design was a randomized block design with three replication, testing varieties were 4 hybrids (Suwon 19, Kwanganok, Whengsungok, Suwonok ) of native corn hybrids and 13 hybrids (P 3156, P 3352, P 3144w, DK 501, DK 689, DK 713, DK 729, H 643.99, H 545.64, H 645.12, HC 7466, H 644.18, H ALISEO) of imported corn hybrids. The results obtained are summarized as follows; 1. The emergence rate of H643.99 was the highest with 97.0%. In rice black streaked dwarf virus(RBSOV), the hybrid of HC 7466 was lower infected with 1.6% than other hybrids. The plant hight of P 3144w was the highest with 339 cm and the stem length of P 3156 was the highest with 261 cm. In native com hybrids, the plant height and stem length of Kwanganok were recorded with 306 cm and 235 cm, respectively. 2. Leaf number and leaf area of Kwanganok were the greatest with 16 sheet per plant and $5,180\;{\textrm{m}^2}/l0a$, respectively. H 645.12 and H 545.64 had the greatest in ear to total dry matter ratio with 49.5% and 49.4%, respectively. 3. The fresh matter yield was significantly difference between growth stage, So Suwon 19 had the most level at 15 days before silking, P 3352 had the most level at silking date, Kwananok had the most level at 35 days a after silking. The fresh matter yield of native com hybrids such as Suwon 19 and Kwanganok was not apparent diffreences as compared with imported corn hybrids. 4. As the results of survey with dry weight, the quantity of dry matter accumulation were increase after silking. The varieties of P 3352, P 3156, Kwanganok, OK 713 were more quantity of dry matter production than DK 501, HC 7466. The Kwanganok of native com hybrid and Pioneer strain with high percentage of dry matter were higher dry weight than Limagrain strain. 5. HC 7466 had the largest LAR with $6.53\;{\textrm{cm}^2}/g$, H545.12 had the lowest LAR with $3.30\;{\textrm{cm}^2/g}$. P 3144 had the largest LAI, DeKalb strain including DK 713 were larger apparently than Limagrain strain including HC 7466 with 3.15. 6. The RGR of testing varieties was little difference of statistical significantly, but DK 501, and HC 7466 were lower than other corn hybrids. The CGR of native and American varieties was no apparent differences, but that of Limagrain strains were a large variation. According to the results obtained by this experiment, the eary growth such as emergence rate and RBSDV infection rate of Limagrain strains was more excellent than other strains. P 3156, P 3352, P 3144w, DK 713 and HC 7466 were suitable for silage condition such as dry matter yield, percentage of dry matter and % ear to total dry matter. The fresh and dry matter yield of native corn hybrids such as Suwon 19 and Kwanganok were not apparent differences as compared with imported corn hybrids, but percentage of dry matter was lower than other imported corn hybrids.

  • PDF

Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF