• Title/Summary/Keyword: 참고범위

Search Result 270, Processing Time 0.023 seconds

Reference Values for Total RBC, Hematocrit, Hemoglobin, and Total WBC in Male Elk Deer (Cervus Canadenis) Reared in Korea (한국에서 사육되는 수컷 엘크 사슴 (Cervus Canadenis)의 적혈구수, 적혈구 용적율, 헤모글로빈 및 총백혈구 수에 대한 참고범위)

  • Yoon Ha-Chung;Jeong Soon-Wuk;Yoo Il-Joon;Kim Jin-Suk;Kim Yeoun-Wuk;Lee Won-Chang;Kim Tae-Jong
    • Journal of Veterinary Clinics
    • /
    • v.23 no.2
    • /
    • pp.111-113
    • /
    • 2006
  • Normal reference values for hematological parameters were evaluated using 85 male Elk deer reared in Korea. The reference interval estimated were 6.01-9.93 (${\times}10^6/mm^3$) for the red blood cell count, 10.90-19.70 (g/dl) for the hemoglobin concentration, 43.10-76.40 (%) for the hematocrit value, and 2.60-7.68 (${\times}10^6/mm^3$) for the total white blood cell count. Our estimates were compared with previously reported values for these parameters in Korea and other countries.

Evaluation of Reference Intervals of Some Selected Chemistry Parameters using Bootstrap Technique in Dogs (Bootstrap 기법을 이용한 개의 혈청검사 일부 항목의 참고범위 평가)

  • Kim, Eu-Tteum;Pak, Son-Il
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.509-513
    • /
    • 2007
  • Parametric and nonparametric coupled with bootstrap simulation technique were used to reevaluate previously defined reference intervals of serum chemistry parameters. A population-based study was performed in 100 clinically healthy dogs that were retrieved from the medical records of Kangwon National University Animal Hospital during 2005-2006. Data were from 52 males and 48 females(1 to 8 years old, 2.2-5.8 kg of body weight). Chemistry parameters examined were blood urea nitrogen(BUN)(mg/dl), cholesterol(mg/dl), calcium(mg/dl), aspartate aminotransferase(AST)(U/L), alanine aminotransferase(ALT)(U/L), alkaline phosphatase(ALP)(U/L), and total protein(g/dl), and were measured by Ektachem DT 60 analyzer(Johnson & Johnson). All but calcium were highly skewed distributions. Outliers were commonly identified particularly in enzyme parameters, ranging 5-9% of the samples and the remaining were only 1-2%. Regardless of distribution type of each analyte, nonparametric methods showed better estimates for use in clinical chemistry compare to parametric methods. The mean and reference intervals estimated by nonparametric bootstrap methods of BUN, cholesterol, calcium, AST, ALT, ALP, and total protein were 14.7(7.0-24.2), 227.3(120.7-480.8), 10.9(8.1-12.5), 25.4(11.8-66.6), 25.5(11.7-68.9), 87.7(31.1-240.8), and 6.8(5.6-8.2), respectively. This study indicates that bootstrap methods could be a useful statistical method to establish population-based reference intervals of serum chemistry parameters, as it is often the case that many laboratory values do not confirm to a normal distribution. In addition, the results emphasize on the confidence intervals of the analytical parameters showing distribution-related variations.

A Study on the Primary Parts of Reference Collection Development Policy in Academic Libraries (대학도서관의 참고 장서개발정책 기본요소 개발에 관한 연구)

  • Choi, Jae Hwang
    • Journal of Korean Library and Information Science Society
    • /
    • v.44 no.1
    • /
    • pp.409-432
    • /
    • 2013
  • The purpose of this study is to examine 5 writing guidelines of reference collection development policy(RCDP) and to identify major elements of RCDP through the comparison and analysis of 24 RCDP in academic libraries in the U.S. As a result of this study, a total of 9 elements(5 core elements and 4 selective elements) were identified. Five core elements were (1) introduction, (2) scope, size, and level, (3) format, (4) types, and (5) management(i.e., selection, weeding, evaluation, and responsibilities) of reference collection. The results of this study would be helpful to those academic libraries which are planning to write RCDP in academic libraries in the near future.

Evaluation of Pregnancy and Thyroid Function (임신과 갑상선 기능의 평가)

  • Park, Chang-Eun
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • During early pregnancy, before the development of a functioning thyroid gland, thyroid stimulating hormone (TSH) is a very sensitive marker of thyroid dysfunction during pregnancy. Normal values have been modified during gestation with a downward shift. The fetus is influenced by the TSH supplied by the mother. TSH and free thyroxine (FT4) concentrations vary during pregnancy and conventional units can vary between laboratories. A downward shift of the TSH reference range occurs during pregnancy, with a decrease in both the lower and upper limits of maternal TSH, relative to the typical non-pregnant TSH reference range. Each laboratory produces its own reference TSH and FT4 concentrations because there are many different assays that yield different results in pregnancy. Therefore, automated immunoassays used for serum FT4 analysis are still used widely, but the important considerations discussed above must be noted. The use of population-based, trimester-specific reference ranges remains the best way to handle this issue The slight downward shift in the upper reference range of TSH occurring in the latter first trimester (7~12 weeks) of pregnancy, typically not observed prior to 7 weeks. Their use indicates high or low levels in a quantitative manner independent of the reference ranges. These data highlight the importance of calculating population-based pregnancy-specific thyroid parameter reference intervals. A precision medicine initiative in this area will require the collection and analysis of a large number of genetic, biological, psychosocial, and environmental variables in large cohorts of individuals. Large prospective randomized controlled trials will be needed to resolve these controversies.

Establishment of Reference Range of Proinsulin (Proinsulin 참고치 설정에 관한 연구)

  • Nam, Yee Moon;Shin, Yong Hwan;Kim, Ji Young;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.76-79
    • /
    • 2013
  • Purpose: It is very important to establish the appropriate reference range in the laboratory for preventing mistakes like false positive or false negative. Because the reference range in the laboratory is standard of patient test results interpretation. Proinsulin is precursor hormone of insulin, and the importance is increasing for diagnosing diabetes or insulinoma. Proinsulin reagent used in our laboratory is produced in the USA, and the reference range provided by manufacturer was adapted to our reference range after the validation test. But, it is generally recommend for the every laboratory to establish the their own reference range. So, we decided to re-evaluate the reference range with our patients' test results. Materials and Methods: Among 737 patients who had been to health promotion center in our hospital between Dec. $8^{th}$ 2011 and Dec. $21^{st}$ 2011, 563 patients are chosen with exception of diabetics patients and patients showing abnormal test results in Fasting Glucose, HbA1c, Insulin, and C-peptide. The 563 test results (275 males and 288 females) were classified with three groups(entire, male, female), and analysis of normal distribution was performed with aid of SPSS(version 19.0). Because Each group didn't show normal distribution, the reference range was set from the lowest limit of 2.5% to the highest limit of 97.5% with Percentile method used in non-normal distribution. Results: When evaluation values are sorted in ascending order, the entire range is 4.5~52.0 pM and 5.3~51.9 pM for male and 4.5~52.0 pM for female. The calculated reference range with percentile method shows 6.7~26.5 pM for entire group, 6.8~26.5 pM for male and 6.7~26.5 pM for female, respectively. Conclusion: The reference range provided by reagent manufacturer is 6.4~9.4 pM and the one established in this study is 6.7~26.5 pM. This difference might be caused by racial characteristics between Western people and Koreans. So an ideal reference range can be gotten with normal population visiting to every hospital. Our hospital has been using the newly re-establishing reference range under consultation with the department of endocrinology since Aug. $1^{st}$ 2012.

  • PDF

Distribution of the Fasting Lipid Levels and Validation of the Reference Interval in Korean Adolescents (우리나라 소아청소년의 공복 혈중 지질 농도의 분포 및 참고범위의 타당성 검증)

  • Kwon, Seyoung;Na, Youngak
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.50 no.3
    • /
    • pp.253-260
    • /
    • 2018
  • With the growing prevalence of dyslipidemia in adolescents, its early detection and management is becoming increasingly important. This study overviewed the fasting lipid concentration distribution of adolescents according to the sex and age, and reviewed the percentile of its reference interval. This study targeted 2,713 adolescents aged between 10 and 19 (1,436 boys, 1,275 girls) based on the data from 2013 to 2016, Korean Health and Nutrition Examination Survey. The mean fasting lipid concentration of total cholesterol, LDL cholesterol, HDL cholesterol, non-HDL cholesterol, and triglyceride of girls was higher than those of boys. Although the $95^{th}$ percentile of the cholesterol value was 200 mg/dL in boys, which was equivalent to the diagnosis criterion, the mean value of girls was 208 mg/dL, staying between the $90^{th}$ and $95^{th}$ percentiles. The $95^{th}$ percentiles of the LDL cholesterol, non-HDL cholesterol, and triglyceride value were 123, 148, and 147 mg/dL in boys, respectively, and 131, 149, and 139 mg/dL in girls, respectively. Most of the criteria of dyslipidemia were at the proper level, within the $90^{th}$ and $95^{th}$ percentile. While the criteria of LDL cholesterol (130 mg/dL) was higher in boys, the triglycerides was higher in girls. In conclusion, criteria more suitable to Korean adolescents will need to be established with further studies.

Receiver Operating Characteristic (의학적 진단에서 ROC 곡선의 활용)

  • 박선일
    • Journal of the korean veterinary medical association
    • /
    • v.36 no.2
    • /
    • pp.121-134
    • /
    • 2000
  • 의학적 진단에서 검사결과가 연속형으로 측정되는 예는 매우 많다. 예를 들어 ELISA검사, 혈청화학적 검사, 방사선 검사 (이 경우에는 음성, 의양성, 양성등의 척도로 표현될 수 있음) 등에서는 적절한 기준을 설정한 후 이 기준점을 근거로 양성과 음성으로 판정하게 된다. 여기에서 한 가지 문제는 기준점 설정에 있다. 소위 정상 혹은 참고범위 (normal or reference range)가 분명히 있는 경우라고 실제 판정에 있어서는 질별이 없음에도 불구하고 검사결과 질병이 있는 것으로 판정할 오류 (혹은 그 반대)가 분명히 존재한다. 본 논문에서는 이러한 상황에서 접근할 수 있는 한가지 방법인 ROC 곡선에 대하여 설명하고자 한다.

  • PDF

알아두면 편리합니다

  • The Korean Dental Association
    • The Journal of the Korean dental association
    • /
    • v.29 no.1 s.260
    • /
    • pp.55-65
    • /
    • 1991
  • 협회지 편집부에서는 진료생활을 통하여 일상 참고될만한 내용, 즉 세무상식, 의료보험, 의료광고범위, 회원연수교육규정등의 내용을 간추려 "알아두면 편리합니다"라는 제목으로소개하여 명랑하고 원만한 병원경영에 도움이 되고자 합니다.

  • PDF

Defintion and Trends of Cosmceuticals (기능성 화장품의 정의와 동향)

  • 안정림
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.23 no.1
    • /
    • pp.21-42
    • /
    • 1997
  • 세계의 화장품 개발방향은 소비자의 욕구와 다양화와 관련기술 등의 발달로 인하여 피부미화, 청결 등의 단순한 효능에서 이제 고기능, 다기능을 갖는 제품들의 개발로 변화되고 있다. 이러한 세계적인 추세에 따라 국제화된 국내시장에도 기능성 화장품이 수입 또는 제조되고 있으며 국내 소비자들도 이러한 제품을 선호하는 경향을 보이고 있으므로 이를 적정하게 규제하며 소비자를 보호하기 위하여 기능성 화장품의 정의가 필요하게 되었다. 정의설정을 위해 미국, EU, 일본 등의 화장품의 정의와 범위 등을 연구하고 실제 판매되고 있는 제품들을 참고하여 기능성 화장품을 정의하였다. 또, 이러한 화장품의 범위 등을 구체적으로 설정하고 이에 대한 규제동향 등을 제사하고자 한다.

  • PDF

Evaluation of reference value of anti-Glutamic acid decarboxylase antibody for cerebrospinal fluid (뇌척수액에서 항 Glutamic acid decarboxylase 항체검사의 참고치 설정)

  • Park, Min-Ho;Shin, Sun-Young;Youn, Tae-Seok;Shin, Hi-Jung;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.28-30
    • /
    • 2017
  • Purpose Anti-Glutamic acid decarboxylase antibody test (GAD Ab) has been used as a predictor of type 1 diabetes. GAD Ab has also been shown to be highly potent in cerebrospinal fluid (CSF) of patients with suspected diabetic peripheral neuropathy. Recently, it has been known that clinical significance of GAD Ab using CSF is useful for the neurological disorders. However, the reference value of anti-GAD Ab has been provided only for serum. In this experiment, we estimated the reference value of anti-GAD antibody for CSF in neurological patients. Materials and Methods A total of 211 neurological patients were enrolled. Serum and CSF were analyzed by radioimmunoassay (RIA) using commercial RIA anti-GAD Ab kit (RSR, London, United Kingdom). Normal saline was used as the normal CSF control because CSF is most similar to 0.9% normal saline. Results The mean value of normal CSF control was 1.97 U/mL, and two standard deviations (2SD) was 1.44 U/mL. Based on this data, the expected reference range of CSF could be estimated from 0.54 U/mL to 3.40 U/mL Conclusion The reference range of normal CSF control using normal saline obtained with Hoffmann's method. However, there will be a need to validate the CSF reference values using human normal CSF.

  • PDF