• Title/Summary/Keyword: 참고값

Search Result 339, Processing Time 0.022 seconds

A Study on the Job Stress of Opticians (안경사 직무스트레스에 관한 연구)

  • Hwang, Hae-Young;Kim, Hyun-Mok;Kim, In-Soo;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • Purpose: This study is conducted to evaluate the job stressors for opticians in Ulsan city. Methods: We investigated job stress of 180 opticians working in Ulsan. The results of this study from The Korean standard job stressors assessment tool developed by Korea occupational safety and health agency (KOSHA) was compared with Korean reference value. The questionnaire on the social, demographic characteristics of opticians was also used to find the factors affecting to job stressors by using multiple linear regression analysis. Results: Among the eight fields of stressors, the interpersonal conflict (the median value; 33.4, the measurements; men; 38.8, women; 41.5) and company culture (the median; 41.7, the measurements; men; 47.4, women; 49.3) were higher than the median value of the Korean workers. By multiple linear regression analysis, the significant factors to the interpersonal conflict were the duty, working hours, unmarried, average salary. In terms of the company culture, last school, rest day of month, job career, average salary and working hours were significantly associated to the score of company culture. Conclusions: Based on the results, important factor in the formation of a positive organizational culture through to improve treatment of opticians investigation and mutual horizontal communication systems in the workplace for the manage on interpersonal conflict and company culture.

Establishment of Reference Value of Insulin Using the Statistical Analysis (통계적 분석을 통한 Insulin의 정상 참고치 설정)

  • Kim, Whe-Jung;Yoon, Pil-Young;Shin, Young-Goon;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.143-146
    • /
    • 2010
  • Purpose: Insulin is involved in carbohydrate metabolism and also it's very important because it increases storage of glycogen, synthesis of fatty acids, absorption of amino acid, synthesis of protein. Insulin is clinically useful when we evaluate fasting patients in hypoglycemia, classify and predict diabetes, assess the activity of ${\beta}$-cell, research insulin resistance. We are going to increase usability of insulin assay by establishing normal reference value according to statistical analysis. Material & Method: We selected 6,648 patients who visited asan health medical center from May to August in 2008. We set exclusion criteria as family of diabetes, diabetes medication, the past history of blood glucose rise, more than 100 mg/dL in normal fasting blood glucose, outside the scope of BMI 18.5~22.9 $kg/m^2$, and more than HbA1c 6.5%. We determine whether the subgroup is portioned as sex and age or not and establish normal reference value by conducting statistical analysis as Bayesian's method and Hoffman's method. Result: Portioning of subgroup as sex and age is not needed. By statistical analysis of Bayesian method, results 1.5-11.0 uIU/mL. By statistical analysis of Hoffman method, results 1.8~12.8 uIU/mL. Conclusion: We established 1.8~12.8 uIU/mL as Insulin normal reference value by Hoffman method. This is a similar value with reporting reference value 1.7~11.8 uIU/mL in kit. This will enhance the usability of insulin assay by establishing normal reference value.

  • PDF

Evaluation of reference value of anti-Glutamic acid decarboxylase antibody for cerebrospinal fluid (뇌척수액에서 항 Glutamic acid decarboxylase 항체검사의 참고치 설정)

  • Park, Min-Ho;Shin, Sun-Young;Youn, Tae-Seok;Shin, Hi-Jung;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.28-30
    • /
    • 2017
  • Purpose Anti-Glutamic acid decarboxylase antibody test (GAD Ab) has been used as a predictor of type 1 diabetes. GAD Ab has also been shown to be highly potent in cerebrospinal fluid (CSF) of patients with suspected diabetic peripheral neuropathy. Recently, it has been known that clinical significance of GAD Ab using CSF is useful for the neurological disorders. However, the reference value of anti-GAD Ab has been provided only for serum. In this experiment, we estimated the reference value of anti-GAD antibody for CSF in neurological patients. Materials and Methods A total of 211 neurological patients were enrolled. Serum and CSF were analyzed by radioimmunoassay (RIA) using commercial RIA anti-GAD Ab kit (RSR, London, United Kingdom). Normal saline was used as the normal CSF control because CSF is most similar to 0.9% normal saline. Results The mean value of normal CSF control was 1.97 U/mL, and two standard deviations (2SD) was 1.44 U/mL. Based on this data, the expected reference range of CSF could be estimated from 0.54 U/mL to 3.40 U/mL Conclusion The reference range of normal CSF control using normal saline obtained with Hoffmann's method. However, there will be a need to validate the CSF reference values using human normal CSF.

  • PDF

A Study on Establishment of Reference Value of CA 72-4 (CA 72-4 참고치 설정에 관한 연구)

  • An, Jae-Seok;Kim, Ji-Na;Joe, Ye-Ji;Yoon, Sang-Hyuk;Kim, Yoon-Cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.25-28
    • /
    • 2021
  • Purpose CA 72-4 is a tumor marker that uses two monoclonal antibodies, CC49 and B72.3, to measure tumor-related glycoprotein(TAG72) in the serum. CA 72-4 is used to diagnose stomach, ovarian, and pancreatic cancers, and is known to perform high specificity for stomach cancer. The purpose of this study is to re-evaluate the reference value provided by the manufacturer through revalidation of the reference value in CA 72-4. Furthermore this study was conducted to provide useful help when making a clinical diagnosis at gastric cancer center. Materials and Methods We selected 271 patients who had been to health care center in national cancer center for the month of November 2020. The gender of the subjects was 140 males and 131 females, and the age group was from 30s to 60s. The reagent used in the study was a CA 72-4 IRMA KIT (ISOTOPES, Hungary) and the results were measured using a Dream Gamma-10 gamma counter (Shinjin medics, Korea). Results Statistical analysis of the results of this study used Hoffmann's method and Bayesian's method, which are primarily used in setting reference value. As a result of measuring CA 72-4 of 271 patients, the mean value was 4.54 U/mL and the median value was 3.30 U/mL. 24 people who deviated from 3SD were excluded from the measured value, the mean calculated after that was 3.53 U/mL, median was 3.00 U/mL and SD was 1.89. The reference value calculated based on this results was set to 7.31 U/mL. Conclusion The reference value provided by the manufacturer is less than 4 U/mL. It is slightly different from the value calculated in this study, 7.31 U/mL, so it seems necessary to reset the reference value according to the laboratory environment. Currently, we are receiving inquiries about the reference value from the center for gastric cancer at National Cancer Center. If additional research is carried out along with this study, it will be possible to set more accurate reference value.

Radiation Dose using Chest CT for Patients with Pneumoconiosis Complication - Comparison with International Guidelines - (진폐요양환자의 흉부 CT촬영에 사용된 선량 - 국내외 진단 참고 준위와 비교 -)

  • Lee, Won-Jeong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.206-212
    • /
    • 2014
  • We report here on the results of evaluating the radiation doses using chest computed tomography (CT) for patients with pneumoconiosis complication. For the first time, we visited the 17 MIPs to evaluate the dose-length product (DLP, $mGy{\cdot}cm$), CT unit, and protocols of scanning and image reconstruction those is routinely used for treating patients with pneumoconiosis who have complication. All statistical analysis was performed using the Statistical Program for Social Sciences (SPSS ver. 19.0, Chicago, IL, USA). Mean of total DLP was $727.7mGy{\cdot}cm$, ranging from 272.0 to $1228.7mGy{\cdot}cm$. DLP from obtaining parenchymal lung images was significantly reduced than that from obtaining total lung images (555.9 vs. 707.2, p<0.001). Third quartile of total and pre-scanning DLP was 1036.1 and $504.1mGy{\cdot}cm$, respectively. Chest CT radiation doses for patients with pneumoconiosis complication are similar with korean diagnostic reference level as well as international guidelines.

Kernel Pattern Recognition using K-means Clustering Method (K-평균 군집방법을 이요한 가중커널분류기)

  • 백장선;심정욱
    • The Korean Journal of Applied Statistics
    • /
    • v.13 no.2
    • /
    • pp.447-455
    • /
    • 2000
  • We propose a weighted kernel pattern recognition method using the K -means clustering algorithm to reduce computation and storage required for the full kernel classifier. This technique finds a set of reference vectors and weights which are used to approximate the kernel classifier. Since the hierarchical clustering method implemented in the 'Weighted Parzen Window (WP\V) classifier is not able to rearrange the proper clusters, we adopt the K -means algorithm to find reference vectors and weights from the more properly rearranged clusters \Ve find that the proposed method outperforms the \VP\V method for the repre~entativeness of the reference vectors and the data reduction.

  • PDF

A Study of The reference value of the CUSUM control chart that can detect small average changes in the process

  • Jun, Sang-Pyo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.12
    • /
    • pp.73-82
    • /
    • 2020
  • Most process date such as semiconductor and petrochemical processes, autocorrelation often exists between observed data, but when the existing SPC(Statistical process control) is applied to these processes, it is not possible to effectively detect the average change of the process. In this paper, when the average change of a certain size occurs in the process data following a specific time series model, the average of the residuals changes according to the passage of time, and the change pattern of the average is introduced around the ARMA(1,1) process. Based on this result, the reference value required in the design process of the CUSUM (Cumulative sum) control chart is appropriately considered by considering the type of the time series model of the process data of the CUSUM control chart that can detect small mean changes in the process and the width of the process mean change of interest. It was confirmed through simulation that it should be selected and used.

Calculation of At-sensor radiance for KOMPSAT-2 image collection planning (KOMPSAT-2 촬영계획을 위한 At-sensor radiance 계산)

  • Lee, Dong-Han;Seo, Doo-Chun;Song, Jeong-Heon;Choi, Myung-Jin;Yang, Ji-Yeon;Jung, Ho-Ryung;Lim, Hyo-Suk
    • Proceedings of the KSRS Conference
    • /
    • 2009.03a
    • /
    • pp.18-21
    • /
    • 2009
  • 2006년 발사되어 현재 운영 중인 아리랑위성 2호의 활용도를 높이기 위해서는 촬영 지역의 radiance 값에 따라 아리랑위성 2호의 TDI와 Vp gain 값을 조절해야만, 10bit인 radiometric resolution을 넓게 사용할 수가 있다. 촬영하고자 하는 지역의 radiance 값을 미리 예측하기 위해서, 한 픽셀이 $250km\times250km$인 월별 전 세계 radiance 평균값을 기본으로 촬영 날짜, 촬영 시각, 촬영 지역의 기후 조건 및 아리랑위성 2호의 ON-to-Radiance 변화 계수 값들을 사용하여서 최종 At-sensor radiance 값을 계산하는 알고리즘을 개발하였다. 실제 아리랑위성 2호의 자료수집계획 작성 시에 참고 값으로 사용 중이고, 80%이상의 정확도가 있음을 확인하였다.

  • PDF

Set Up and Operation for Medical Radiation Exposure Quality Control System of Health Promotion Center (건강검진센터의 의료방사선 피폭 품질관리 시스템 구축 운영 경험 보고)

  • Kim, Jung-Su;Jung, Hae-Kyoung;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.13-17
    • /
    • 2016
  • In this study, standard model of medical radiation dosage quality control system will be suggested and the useful of this system in clinical field will be reviewed. Radiation dosage information of modalities are gathered from digital imaging and communications in medicine(DICOM) standard data(such as DICOM dose SR and DICOM header) and stored in database. One CT scan, two digital radiography modalities and two mammography modalities in one health promotion center in Seoul are used to derive clinical data for one month. After 1 months research with 703 CT scans, the study shows CT $357.9mGy{\cdot}cm$ in abdomen and pelvic CT, $572.4mGy{\cdot}cm$ in brain without CT, $55.9mGy{\cdot}cm$ in calcium score/heart CT, screening CT at $54mGy{\cdot}cm$ in chest screening CT(low dose screening CT scan), $284.99mGy{\cdot}cm$ in C-spine CT and $341.85mGy{\cdot}cm$ in L-spine CT as health promotion center reference level of each exam. And with 1955 digital radiography cases, it shows $274.0mGy{\cdot}cm2$ and for mammography 6.09 mGy is shown based on 536 cases. The use of medical radiation shall comply with the principles of justification and optimization. This quality management of medical radiation exposure must be performed in order to follow the principle. And the procedure to reduce the radiation exposure of patients and staff can be achieved through this. The results of this study can be applied as a useful tool to perform the quality control of medical radiation exposure.

The Measurement of Refractive Index by using Michelson Interferometer with Rotating Sample (Michelson 간섭계를 이용한 굴절률 측정)

  • Kang, Kab Jung;Cha, Jung Won;Kim, Chung-Sik;Kim, Jung Nam
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.73-79
    • /
    • 1999
  • The main purpose of this paper is to construct and analyze the Michelson interferometer with rotating sample in order to measure refractive index of solid plate. The theoretical equation and experimental method was proposed in this work. The measured refractive indexes by this system are $n_{6328}$=1.5159 in BK7 and $n_{6328}$=1.4528 in fused silica. These values make a differences by 0.001 in BK7 and 0.003 in fused silica from those of reference. As a result, Michelson interferometer with rotating sample is very advantageous method to find refractive index of plate sample.

  • PDF