• Title/Summary/Keyword: 착화시간

Search Result 141, Processing Time 0.02 seconds

Numerical Study of Evaporation and Ignition of in-line Array Liquid Droplets (액적 배열의 증발과 착화에 관한 수치해석적 연구)

  • 김충익;송기훈
    • Fire Science and Engineering
    • /
    • v.13 no.1
    • /
    • pp.37-47
    • /
    • 1999
  • The spreading fire of very small floating particles after they are ignited is fast and t therefore dangerous. The research on this area has been limited to experiments and global simulations which treat them as dusts or gaseous fuel with certain concentration well m mixed with air. This research attempted micro-scale analysis of ignition of those particles modeling them as liquid droplets. For the beginning, the in-line array of fuel droplets is modeled by two-dimensional, unsteady conservation equations for mass, momentum, energy and species transport in the gas phase and an unsteady energy equation in the liquid phase. They are solved numerically in a generalized non-orthogonal coordinate. The single step chemical reaction with reaction rate controlled by Arrhenius’ law is assumed to a assess chemical reaction numerically. The calculated results show the variation of temperature and the concentration profile with time during evaporation and ignition process. Surrounding oxygen starts to mix with evaporating fuel vapor from the droplet. When the ignition condition is met, the exothermic reactions of the premixed gas initiate a and burn intensely. The maximum temperature position gradually approaches the droplet surface and maximum temperature increases rapidly following the ignition. The fuel and oxygen concentration distributions have minimum points near the peak temperature position. Therefore the moment of ignition seems to have a premixed-flame aspect. After this very short transient period minimum points are observed in the oxygen and fuel d distributions and the diffusion flame is established. The distance between droplets is an important parameter. Starting from far-away apart, when the distance between droplets decreases, the ignition-delay time decreases meaning faster ignition. When they are close and after the ignition, the maximum temperature moves away from the center line of the in-line array. It means that the oxygen at the center line is consumed rapidly and further supply is blocked by the flame. The study helped the understanding of the ignition of d droplet array and opened the possibility of further research.

  • PDF

A Study on Fire Characteristics of Sofa Cover Materials (소파커버의 연소특성에 관한 연구)

  • 이광흠;박영근;윤명오;현성호;김동일
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.35-42
    • /
    • 2003
  • In this study, we tried to evaluate the ignitibility, flammability, heat release rate, and toxicity of five different types of burning artificial leather sofa covers that are widely used in entertainment service industry buildings. As the results of this study, putting the artificial leathers under fire conditions we found out following results auto-ignition temperature was$ 427~437^{\circ}C$, limiting oxygen index was 19~20%; at heat flux of $25 kW\m^2$, ignition time was 10~16s and peak heat release rate was $147~277 kW\m^2$; and at heat flux of$ 35 kW\m^2$, ignition time was 6~9s and peak heat release rate was $176~296 kW\m^2$. The toxic materials discharged from the burning leathers were 5,550~6,290 ppm of CO, 18,500~23,400 ppm of $CO_2$, 110~140 ppm, of HCl, 13~65 ppm of HCN and 145~220 ppm of NOx.

A Study on Vibration Characteristics for Misfiring Condition of Large Marine Diesel Engines using Accelerometer Signal (가속도 신호를 이용한 대형 선박용 디젤엔진의 착화실패 상태에 대한 진동 특성 연구)

  • Seo, Jong-Cheol;Kim, Sang-Hwan;Kim, Jung-Sung;Lee, Don-Chool
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.578-579
    • /
    • 2010
  • 최근 내연 기관에서 엔진상태 및 잠재적인 결함의 발견을 위해 연료분사, 실린더 내 연소과정, 실린더 내부와 피스톤 마모상태, 흡 배기 밸브 및 과급기 (turbocharger) 등의 상태 모니터링을 통해서 결함에 대한 진단 및 경향관리에 대한 연구들이 진행되고 있다. 본 연구에서는 기 개발된 선박용 대형디젤엔진에 대한 상시 모니터링 시스템을 이용하여 엔진상태 및 잠재적인 결함을 진단하고자 하였으며, 일차적으로 가속도 신호를 이용하여 실린더 내 연소과정에서 정상적인 상태와 착화실패에 따른 진동 양상을 비교 분석하였다. 신호 분석 기법으로 시간-주파수 분산 기법들은 충격파 신호인 엔진 폭발신호를 분석하는데 적합하였으며, 그 기법들 중 Short Time Fourier Transform 기법과 Wavelet Transform 기법을 이용하였다.

  • PDF

The Ignition Characteristics of Dead Leaves and Living Leaves of Various Trees in Young Dong Forest Areas (영동지역 주요 수종별 낙엽과 생엽의 착화특성에 관한 연구)

  • Park, Young-Ju;Lee, Si-Young;Sin, Young-Ju;Kim, Su-Young;Kim, Young-Tak;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.298-302
    • /
    • 2008
  • In this study, we have carried out the test to examine the ignition characteristics, such as a relation of moisture content and combustibility, and ignition temperature using KRS-RG-9000 tester, living leaves and dead leaves of significant 7 species of Young Dong Provinces of Korea after and before the rainfall. After 144 hours at normal temperature, the percentage of water content of the needle-shaped leaves was less than 10%. So it is suppose to be ignite easily. On the other hand, the self-temperature to ignite of broadleaf is higher. So the retard time at lower temperature is more long than needle-shaped leaf. Consequently, the fire-resistant qualities of broadleaf is higher than needle-shaped leaf.

  • PDF

Combustion Characteristics of Fiber Reinforced Plastic by Cone Calorimeter (콘칼로리미터를 이용한 섬유강화플라스틱(FRP)의 연소특성)

  • 이근원;김관응;이두형
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.67-72
    • /
    • 2004
  • This study describes to assess combustion characteristics of fiber reinforced plastic (FRP) that is used an elements of building or structure in workplace. The combustion characteristics of the fiber reinforced plastic were carried out using by a Cone Calorimeter according to ISO 5660 standard. As the results of this study, the time to ignition and heat release rate of the fiber reinforced plastic was differ with heat flux of irradiance and content of flame retardant agent. The heat release rate of the fiber reinforced plastic was increased with increasing heat flux of irradiance. The flashover propensity of the fiber reinforced plastic using time to ignition and peak heat release rate was examined according to classification method by R.V. Petrella.

The Thermal Characteristics of Tree Branches, Barks, Living Leaves and Dead Leaves in Pinus Densiflora and Quercus Dentata (소나무와 떡갈나무의 주요 부위별 열적특성에 관한 연구)

  • Park, Young-Ju;Lee, Si-Young;Lee, Hae-Pyeong
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.84-92
    • /
    • 2008
  • Disclosed is a study related to the thermal characteristics of Pinus densiflora and Quercus dentate identifying the presence of any significant difference in the above trees, which are native to Young Dong Province of Korea, according to different regions of the trees such as branches, barks, living leaves and dead leaves. For this purpose, we have carried out a cone calorimeter test focusing on the variables such as mass loss, heat release, ignition time, flame holding time and concentrations of CO and $CO_2$. The results showed that the total mass loss was greatest in tree branches, whereas the ignition time of dead leaves was fastest both in Pinus densiflora and Quercus dantata. The flame holding times of dead leaves and barks were about $640{\sim}1,016s$ and the total heat release of dead leaves was around 60.1 $MJ/m^2$, twice the total heat release of living leaves. In addition, the maximum exhaust concentrations of CO and $CO_2$ in tree branches of Quercus dentata was 2.82 times higher than those of Pinus densiflora, respectively. From the foregoing, it was confirmed that there exist region-specific differential thermal characteristics in Pinus densiflora and Quercus dentata.

Hazard Evaluation of Minimum Ignition Energy by Electrostatic Voltage in Suspended Dust Particles (부유 분진의 정전압에 의한 최소착화에너지 위험성평가)

  • Han, Oue-Sup
    • Korean Chemical Engineering Research
    • /
    • v.59 no.3
    • /
    • pp.359-365
    • /
    • 2021
  • We investigated experimentally the ignition characteristic of dust and the hazard evaluating for electrostatic discharge. The ignition energy experiments were performed on sample dusts such as PE(HD), PE(LD), PMMA using the MIKE-3 apparatus. The formation of flame during the ignition of PE(HD) dust clouds occurred after the delay time of about 8 ms, and the flame kernels were not observed in center of ignition occurrence area. The voltage increased with increasing the number of dust dispersions and the increase rate of measured voltage with dust concentration was the highest in the order of PMMA, PE(LD) and PE(HD). For the effect of dispersion condition on the voltage in PE(HD) dust, the results were obtained that the voltage increased as the number of dispersions increased and as the concentration increased under the same dispersion number. The safety voltages to prevent fire and explosions by electrostatic ignition were estimated that PE(HD), PE(LD)-1, PE(LD)-2, and PMMA were 2.58, 44.72, 25.82, and 8.16 kV, respectively. We proposed the method for estimating the minimum ignition energy by using the measured voltage data for efficient investigation of electrostatic ignition hazard.

Study on Aging Characteristics of Thru-Bulkhead Initiator (격벽착화기 노화특성 연구)

  • Kang, Wonkyu;Jang, Seung-gyo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.2
    • /
    • pp.43-51
    • /
    • 2020
  • After the accelerated aging, the bulkhead initiator using high explosives was carried out to verify aging characteristics. The Thru-Bulkhead Initiator operates by transmitting shock-wave generated from micro-initiator to the acceptor and the ignition explosives through the bulkhead. In order to evaluate the life-time of the product, the accelerated aging condition was set according to the life-time, and the ignition performance of the sample was measured every 10 cycles by measuring the delay time and the maximum pressure through the 10cc closed bomb test. In addition, variance analysis was used to determine aging.

Analysis on Shock Wave and Sensitivity of Explosives in Through-Bulkhead Initiator (격벽착화기 화약의 충격파와 민감도 분석)

  • Jang, Seung-gyo;Hwang, Jung-min;Baek, Sung-Hyun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.4
    • /
    • pp.36-43
    • /
    • 2017
  • We studied attenuation characteristics of shock waves induced by a donor charge and the sensitivity of an acceptor for optimal design of a TBI (Through-bulkhead initiator). The attenuation behavior of shock waves was studied by measuring free surface velocity using a VISAR (Velocity Interferometer System for Any Reflector), and the sensitivity of the acceptor explosives was analyzed via SSGT (Small Scale Gap Test). It was found that the acceptor sensitivity obtained by the SSGT may be inappropriate for the design of the small-scale explosive devices such as TBI due to the different shock duration time.

Fire Characteristics of Phenolic Resin for Interial Materials of Passenger Train (철도차량 내장재료용 페놀수지의 내열특성)

  • Lee, Cheul-Kyu;Lee, Duck-Hee;Jung, Woo-Sung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.2 s.13
    • /
    • pp.29-34
    • /
    • 2004
  • The time to ignition, heat release rate characteristics, and carbon monoxide yield of fiber reinforced and sandwich phenol resin were investigated with cone calorimeter. The fire characteristics of unsaturated polyester, mostly being applied to the existing passenger train, and phenolic resin were compared. DSC & TGA was used to monitor the degree of thermal decomposition and weight loss for the phenolic resin. According to the cone calorimeter data, the time to ignition was shorter, heat release rate, and CO yield was higher as the external heat flux increased. Under the same heat flux, the time to ignition of sandwich type phenolic resin was shorter than that of laminated. The result of comparison between unsaturated polyester and phenolic resin was that phenolic resin was shown to have better fire resistance than unsaturated polyester.