• Title/Summary/Keyword: 착용성

Search Result 943, Processing Time 0.028 seconds

Efficacy of Lens Shielding Device to Prevent Cataract with Radiotherapy for Orbit or Ocular Adnexal Tumor (안와 및 안부속기 종양의 방사선치료에서 백내장의 예방을 위한 렌즈보호 장치의 효용성)

  • Cho, Jung-Keun;Cho, Hyun-Sang;Han, Tae-Jong
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.12
    • /
    • pp.139-144
    • /
    • 2007
  • Radiotherapy which is the most effective for orbit lymphoma has been used increasingly due to the increase of orbit or ocular adnexal tumor patients. Curative effects and convalescence have been being more satisfied thanks to remarkable development of cancer chemotherapy and medical treatments, but side effects such as cataract, dry eye and retinopathy still break out. Thus, in this study, a Lens Shielding Device (LSD hereafter) was designed to prevent occurring of cataract due to radiation therapy for orbit lymphoma and its efficacy through dosimetry were evaluated. And in this paper, its manufacturing process was also explained. LSD is composed of a cover body covering the lens and a side fixing part supporting the cover body. To measure radiation, the patient therapy conditions were simulated and the measurement of the radiation was conducted with Thermo Luminescence Detector (TLD) and Markus chamber. The average TLD value was 5.7% and the TLD value and Markus chamber value were acquired as 4.2% and 5.1% respectively at 6 mm depth where zero lens center was located. Only 1.5Gy ($300Gy{\times}\;5%$) or 5% of total 30Gy with 9 MeV electron beam is estimated to affect on patient's lens. That is smaller dose than the threshold value of cataract (2GY) or the value (5Gy) that was reported to cause cataract in clinical conditions. Thus, these findings suggest that LSD be very useful for prevention of cataract during radiotherapy for malignant lymphoma of orbit and ocular adnexa. Furthermore, it might be possible to reduce patient's discomfort caused by alien substances and to make it easier to fix the device with customized manufacturing manners.

Clinical Evaluation on Variation of Face Form Angle of Eyewear (안경 안면각 변화에 대한 임상적 고찰)

  • Ko, Da-young;Kim, Ki-hong;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.477-484
    • /
    • 2015
  • Purpose: This study was investigated to evaluate the effect of the variation of the face form angle(FFA) of spectacle frame on the visual acuity and the visual function. Methods: The visual acuity, the contrast sensitivity, the stereopsis, and the phoria were measured with the spectacle frame whose the FFA is at $5^{\circ}$ and $25^{\circ}$ and the surveys were conducted on subjective symptoms. Here, 30 adults (14 men and 16 women, average age:$25.46{\pm}3.9$), who did not have ocular diseases and were fully corrected in case of having had refractive error, were to act as experimental subjects for this measurement. Results: The visual acuity and the contrast sensitivity was decreased and the phoria was tended to increase to the esophoria direction at the FFA $25^{\circ}$ than at the FFA $5^{\circ}$. The stereopsis was significantly reduced at the FFA $25^{\circ}$ than at the FFA $5^{\circ}$. Also when the FFA was larger, the higher the degree of refractive error was, the more the increase of the subjective symptoms such as being blurred characters, being disturbed head, and having sore eyes was, which reveals a statistically significant correlation between them. Conclusions: If the FFA increases, the visual acuity, the contrast sensitivity and the stereopsis was found to decrease and the phoria to increase to the esophoria direction. Therefore it shows that the variation of the FFA of spectacle frame can influence the visual acuity and the visual function.

Perfusion RRI of the Brain Using Oxygen Inhalation (산소 호흡을 이용한 뇌의 관류 자기공명영상)

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.113-119
    • /
    • 2000
  • Purpose : To know the possibility of clinical application of MRI using oxygen inhalation as a perfusion MRI Materials and methods : Two healthy volunteers and three patients of one moyamoya disease, one acute infarction and one meningioma were studied using a 1.5 Tesla MRI unit. Oxygen (15 liters/min) mixed with room air was given using face mask from 8 second to 35 second during the study. Images were acquired 25 times (scan time per study were 1.6 seconds) using susceptibility contrast EPI (echo planar image) sequence. Difference maps were acquired by early (study 12-18), and late (study 19-25) O2 inhalation image groups minus pre-O2 inhalation image group (study 3-9) with a Z-score of 0.7-1.0 using VB31C program of Magneton Vision. The resulting perfusion images were created by superimposition of difference maps on corresponding T1 weighted anatomic images. On moyamoya patient, similar perfusion images were acquired after Gd-DTPA injection, and compared with O2 inhalation perfusion images. Results ; The author can get the perfusion images of the brain by oxygen inhalation with susceptibility contrast EPI sequence at the volunteers, and the patient of moyomoya disease, acute infarction and meningioma. On moyamoya patient, perfusion images with O2 inhalation are similar with perfusion images by Gd-DTPA injection. Conclusion 1 This study has demonstrated that the susceptibility contrast EPI by oxygen inhalation can be used as the clinically useful perfusion MRI technique

  • PDF

Development of Bodice Dress Forms by Body Types for Women in Thirties Applying 3D Body Scan Data (3D 인체 스캔 데이터를 활용한 체형별 인대모형 개발에 관한 연구)

  • Suh, Dong-Ae;Oh, Seol-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.9
    • /
    • pp.136-145
    • /
    • 2012
  • This research proposes a pattern making method for women's bodice by the characters of body types and develops bodice dress forms on their body shapes applying 3D body scan data. 515 women's body scan data was collected and analyzed factor and cluster analysis. Three body types were characterized in normal, obese, and slim group. In each group, 10 subjects were selected. 20 parts in 3D anthropometric data were measured using Autocad program. The amount of waist dart was calculated and three types of basic bodice pattern were developed using the calculated darts data. The amount and the position of front dart and side dart were different at obese group in comparison of normal and thin group. The three types of basic bodice model were made by the basic bodice pattern, and each model was scanned by 3D scanner to make 3D bodice dress forms. Three types of bodice dress forms were rendered using 3D max program. Bodice dress forms had the dart lines and were useful to draft patterns to fit their body shape.

Evaluation of Medial Instability of the Knee with Ultrasonography - Technical note - (초음파를 이용한 슬관절 내측 불안정 평가 -측정기법-)

  • Kim, Jung-Man;Lee, Dong-Yeob;Koh, In-Jun;Kim, Seung-Min
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.1 no.2
    • /
    • pp.73-77
    • /
    • 2008
  • Purpose: The purpose of this study was to describe the method of dynamic sonographic measurements in the evaluation of the MCL injury of the knee joint while applying valgus and varus stress. Materials and Methods: Seven cases of MCL injury from January to April of 2008 was used for the study. For the evaluation of the medial instability, sonography was used immediately after injury, 6 weeks and 12 weeks after conservative treatment with limited motion brace. The length between the foot of the medial femoral epicondyle and the most proximal point of the tibial cortex was measured in 30 degrees flexion with valgus and varus stress of the knee joint. Results: The foot of the medial epicondyle and the starting point of the proximal tibial cortex underneath the round portion of the articular cartilage were always able to be seen on ultrasonography, even in varus and valgus stress with gravity in 30 degrees flexion of the knee joint. The results of measurements were always constant. Conclusion: Sonography can be used in evaluation of medial instability under the dynamic valgus and varus stress of the knee joint without further injury.

  • PDF

The Usefulness of a Wearable Smart Insole for Gait and Balance Analyses After Surgery for Adult Degenerative Scoliosis: Immediate and Delayed Effects (척추측만증 환자의 수술 효과 평가 수단으로서 웨어러블 스마트 깔창을 이용한 보행분석의 유용성)

  • Seo, Min Seok;Shin, Myung Jun;Kwon, Ae Ran;Park, Tae Sung;Nam, Kyoung Hyup
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.2
    • /
    • pp.184-192
    • /
    • 2020
  • This study presents a gait analysis method (including time series analysis) using a smart insole as an objective and quantitative evaluating method after lumbar scoliosis surgery. The participant is a degenerative lumbar scoliosis patient. She took 3-min-gait-test four times(before and 8, 16, and 204-days after surgery) and 6-min-gait-test once(204-days after surgery) with smart-insoles in her shoes. Each insole has 8-pressure sensors, an accelerometer, and a gyroscope. The measured values were used to compare the characteristics of gait before and after surgery. The analysis showed that all of the patient's gait parameters improved after surgery. And after 6 months, the gait was more stable. However, after long walk, the swing duration of one leg was slightly shorter than that of the other again. It was a preclinical problem that could not be found in the visual examination by the practitioner. With this analysis method we could evaluate the improvement of patient quantitatively and objectively. And we could find a preclinical problem. This analysis method will lead to the studies that define and distinguish gait patterns of certain diseases, helping to determine appropriate treatments.

Development of a Mobile Game and Wearable Device for Upper Limb Rehabilitation after Brain Injury (뇌손상 환자의 상지 재활을 위한 웨어러블 장치와 모바일 게임 개발)

  • Lim, Hong Joon;Kang, Youn Joo;Song, Je young;Lee, minbong;Oh, Ji Eun;Ku, Jeonghun
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.3
    • /
    • pp.253-259
    • /
    • 2017
  • Conventional upper extremity rehabilitation paradigm after brain injury has several shortcomings that is monotonous, simple, and repetitive in exercises over a long period of time, thereby causing training efficiency to decline as a consequence of low interest and participation. To resolve this issue, this paper proposes a new rehabilitative program integrating a wearable device integrated with EMG and motion sensor and a mobile game for the upper limbs' rehabilitative training. The developed wearable device is manufactured in the form of band, making it easy to wear. The mobile game is designed to enable rehabilitative training through games reflective of flexion, extension, abduction, and adduction identified by motion sensors along with grasp motion recognized by EMG signals measured from the wearable device. It also provides a tailored rehabilitative environment suitable for individual patients based on difficulty adjustments. As a consequence of applying the developed program to 14 brain injury in need of the upper limb rehabilitation and taking surveys on the utility of the developed rehabilitative program, the responses indicated that the developed rehabilitative program is far much more interesting and fun than the conventional rehabilitative program, further to the desire of those surveyed to reuse the developed program in the future.

Sleep/Wake Dynamic Classifier based on Wearable Accelerometer Device Measurement (웨어러블 가속도 기기 측정에 의한 수면/비수면 동적 분류)

  • Park, Jaihyun;Kim, Daehun;Ku, Bonhwa;Ko, Hanseok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.6
    • /
    • pp.126-134
    • /
    • 2015
  • A sleep disorder is being recognized as one of the major health issues related to high levels of stress. At the same time, interests about quality of sleep are rapidly increasing. However, diagnosing sleep disorder is not a simple task because patients should undergo polysomnography test, which requires a long time and high cost. To solve this problem, an accelerometer embedded wrist-worn device is being considered as a simple and low cost solution. However, conventional methods determine a state of user to "sleep" or "wake" according to whether values of individual section's accelerometer data exceed a certain threshold or not. As a result, a high miss-classification rate is observed due to user's intermittent movements while sleeping and tiny movements while awake. In this paper, we propose a novel method that resolves the above problems by employing a dynamic classifier which evaluates a similarity between the neighboring data scores obtained from SVM classifier. A performance of the proposed method is evaluated using 50 data sets and its superiority is verified by achieving 88.9% accuracy, 88.9% sensitivity, and 88.5% specificity.

자동차 전자파

  • 성현수;신승현;문진동;한종철
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.5 no.4
    • /
    • pp.83-93
    • /
    • 1994
  • 1886년 고트리브 다이믈러와 칼 벤즈가 가솔린 자동차를 개발한 이후 100여년이 지난 지금 자동차는 비약적으로 진보, 발전하여 현대 산업사회와 개인의 생활에 있어 산업운송수단과 이동수단으 로서 필요불가결하게 되어 밀접한 관계를 갖고 있다. 우리나라 자동차 공업의 역사는 자동차가 사회적, 경제적 효용에 따라 그 생산과 보유대수가 날이 갈수록 증가 일로에 있으며, 자동차의 생산대수는 전세 계에서 년간 약 50,606천대('94년)로서 중요한 국가 기간 산업으로 자리하고 있다. 한편 전기, 전자공업의 발전에 따른 자동차의 Car Electronics가 많이 채용되게 됨에 따라 현재의 자 동차에는 대부분이 전자제어 System으로 구성되어 있다. 최근에는 Micro Processor를 이용한 전자부품이 많이 사용되어 전자파에 대한 문제가 다양하게 발생 하고 있다. 예를 들면 미국 캘리포니아주에서 전자점화제어장치와 연료분사 장치를 설치한 구미의 자동 차가 주행중 28MHz, 28W의 아마추어 무선을 탑제한 자동차가 통과할 때 엔진이 고르지 못한 보고가 있 었고, 화학섬유로된 옷을 착용한 전자부품이 다른 부품에 영향을 주는 사례가 맣아지고 있다. 따라서 자동차에는 여러가지의 전장품, 전자기기를 탑재하기 때문에 자동차 자체에서 발생하는 것과 외부로 부터 받는 전자장해 EMI(Electromagnetic Interference), EMS(Electromagnetic Susceptibility) 가 문제로 되어 자동차 및 부품 maker에 의한 EMC(Electromagnetic Compatibility) 평가의 중요성이 고조되고 있다. 차제무전기, 차제무전기, Car-Radio는잡음방해를 많이 받기도 하지만, 잡음원이 되기 도 한다. 또한 Engine 제어, 차속제어, Brake 제어등에 이용되는 전자제품은 방해에 의한 오동작 또는 파괴가 발생하여 주행기능, 안전성에 문제가 야기되지 않도록 해야 한다. 이러한 전자기 환경은 모두 RF(Radio Frequence)와 자동차에서의 전자파 장해 문제의 원이 될 수 있다. 자동차 및 그 부품의 전자기 방해에 관한 규격화는 1987년부터 괄목할 만하게 진행되어 이에 따른 규제 움직임이 IEC(International Electrotechnical Commission: 국제전기기술위원회) 산하의 하부기 구인 CISPR(International Special Committeeon Radio Interference: 국제 무선 장해 특별위원회)가 전자기 방해파에 대한 측정법 통일안을 제안 하였고, ISO(International Standardization Organiza- tion: 국제표준화 기구) 가운데 TC 22/SC3가 자동차의 전장품에 대한 장해를 논의히고 있다. 특히, 자동차의 EMC에 관한 국가 규격은 국제 규격에서 저술한 바와 같이 특별히 규정된 것이 없고 VDE(Verband Deutscher Elektrotechniker: 서독전기기술 협회)와 SAE(Society of Automotive Engi- neers: 자동차 기술자 협회)에서 비교적 활발하고 Jaso(Japanese Automobile Standards Organization: 일본 자동차 표준협회)에서 많이 진행중에 있다. 본 고에서는 자동차의 전자제어에 따른 잡음 발생 요인과 전자파 간섭 관련 자동차 규격과 시험평가 방법에 대해 간단히 소개 하였다.

  • PDF

Estimation of Energy Expenditure using Unfixed Accelerometer during Exercise (비고정식 가속도계를 이용한 운동 중 에너지소비 추정)

  • Kim, Joo-Han;Lee, Jeon;Lee, Hee-Young;Kim, Young-Ho;Lee, Kyoung-Joung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.63-70
    • /
    • 2011
  • In this paper, we proposed a method for estimating energy expenditure using the unfixed axis of the accelerometer. Most studies adopted waist-placement because of the fact that the waist is close to the center of mass of a whole human body. But we adopted pocket-placement, which is capable of using unfixed axis of sensor, that is more convenient than conventional methods. To evaluate the proposed method, 28 male subjects performed walking and running on a motor driven treadmill. All of subject put on the indirect calorimeter and fixed accelerometer, then data were simultaneously measured during exercise. The regression analysis was performed using the test group(n=20) and the regression equation was applied to the control group(n=8). A strong linear relationship between energy expenditure and unfixed accelerometer signal was found. Futhermore, the coefficient of determination was significantly reliable($R^2$=0.98) and showed zero of p-value. The error of energy expenditure estimation between indirect calorimeter and two types of accelerometer was 15.0%(fixed) and 17.0%(unfixed) respectively. These results show the possibilities that the unfixed accelerometer can be used in estimating the energy expenditure during exercise.