Browse > Article

Estimation of Energy Expenditure using Unfixed Accelerometer during Exercise  

Kim, Joo-Han (Dept. Biomedical Engineering, Yonsei University)
Lee, Jeon (Department of Oriental Biomedical Engineering, Daegu Hanny University)
Lee, Hee-Young (Dept. Biomedical Engineering, Yonsei University)
Kim, Young-Ho (Dept. Biomedical Engineering, Yonsei University)
Lee, Kyoung-Joung (Dept. Biomedical Engineering, Yonsei University)
Publication Information
Abstract
In this paper, we proposed a method for estimating energy expenditure using the unfixed axis of the accelerometer. Most studies adopted waist-placement because of the fact that the waist is close to the center of mass of a whole human body. But we adopted pocket-placement, which is capable of using unfixed axis of sensor, that is more convenient than conventional methods. To evaluate the proposed method, 28 male subjects performed walking and running on a motor driven treadmill. All of subject put on the indirect calorimeter and fixed accelerometer, then data were simultaneously measured during exercise. The regression analysis was performed using the test group(n=20) and the regression equation was applied to the control group(n=8). A strong linear relationship between energy expenditure and unfixed accelerometer signal was found. Futhermore, the coefficient of determination was significantly reliable($R^2$=0.98) and showed zero of p-value. The error of energy expenditure estimation between indirect calorimeter and two types of accelerometer was 15.0%(fixed) and 17.0%(unfixed) respectively. These results show the possibilities that the unfixed accelerometer can be used in estimating the energy expenditure during exercise.
Keywords
accelerometer; unfixed axis; indirect calorimeter; regression analysis; energy expenditure;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 F. Patty S, "Calibration of the computer science and applications, Inc. accelerometer", Med Sci Sports Exerc. Vol. 30, no. 5, pp.777-781, May 1998.   DOI   ScienceOn
2 R. Maddison, "Estimating Energy Expenditure With the RT3 Triaxial Accelerometer", Research Quarterly for Exercise and Sport., Vol. 80, no. 2, pp.249-256, Jun 2009.   DOI   ScienceOn
3 C. V. Bouten et al., "A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity", IEEE Trans. Biomed., Vol. 44, No. 3, pp.136-147, March 1997.   DOI   ScienceOn
4 백종훈, "무구속적인 측정에 의한 사용자 활동 상태 추정 기법", 대한전자공학회, 제 46권 SP편, 제 5호, 101-110쪽, 2009년 9월
5 이재영, "가속도계를 이용한 편마비 환자의 보행분석 알고리즘 개발", 대한전자공학회, 제 41권 SC편, 제4호, 55-62쪽, 2004년 7월
6 이준영, "한눈에 알수 있는 의학통계학", 고려대학교 의과대학 의학통계학교실, E PUBLIC, 2007.
7 이은옥, "정상인의 운동 단계에 따른 건강상태와 건강관련 삶의 질 연령, 성, 지역별 차이 비교 자료", 보건복지부, 2001
8 양윤준, "성인의 운동 신체활동의 한국형 표준 측정도구 개발과 한국형 성인 운동 신체활동 표준권장량 설정", 보건복지부, 2007