• Title/Summary/Keyword: 착용성

Search Result 943, Processing Time 0.022 seconds

A Study on the Relationship Between the Off-Axis Cylinder and Corrected Vision of Astigmatism (난시안의 교정축 이탈과 교정시력과의 관계 연구)

  • Kim, Jung Hee;Kang, Sue Ah
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.83-87
    • /
    • 2007
  • This study was classified and compared astigmatism's refractional abnormal degrees with visual acuity state of full correction which turned on axises of only 5 degree, 10 degree, and 15 degree. Subjects of this study were 57 college students (114 eyes) who had neither eye diseases nor binocular abnormality, were from their twenties to fifties, with myopia. It appeared that 30.8% of subjects who had astigmatism wore glasses with wrong axis of astigmatism. After accurate correction of the visual acuity and degrees of astigmatism, when we moved to corrected axises at 5 degree, 10 degree, 15 degree, failure of visual acuity with one line or more were 56.1%, 84.2%, 93.8%, respectively. When we comapre the completely-corrected visual acuity with the visual acuity with dricted axes, the bigger the width of visual acuity's weakness was the bigger the drifted angle. The change of normal visual acuity according to drifting angle of corrected axises of astigmatism, when we compared with full correction, appeared 0.94 in 5 degree, 0.87 in 10 degree, and 0.79 in 15 degree. Drift of 5 degree from fully corrected axis, corresponded to difference of visual acuity about one line, drift of 10 degree to 1.8 line difference of visual acuity, and drift of 15 degree about to 2.6 line difference. Through this study, we were sure that, in the case of drifting away from the right axis of astigmatism, it lead to visual weakness and asthenopia. Therefore we darely advise that optometrists should make mistake of axis least by confirming accucacy of corrected axis after despensing of spectacles of astigmatism.

  • PDF

Visual fatigue in Watching 3 Dimension Television (3D TV 시청에 있어서 시청 피로)

  • Yoon, Jeong Ho;Lee, Ikhan;Kim, Taehyun;Kim, Jae-Do
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.1
    • /
    • pp.47-52
    • /
    • 2012
  • Purpose: This study was to evaluate visual fatigue with passing of watching 3D TV in short term and with experience of watching 3DTV in long term. Methods: 98 adult subjects aged $33.5{\pm}5.5$ years (22 to 51 years; 12 females and 86 males) agreed to participate in this study. Subjects were asked to watch 52 inch LED 2D and 3D television (Shutter glasses method) at 2.7 meters for 65minutes with wearing their habitual glasses or contact lenses. For evaluating visual fatigue, subjects were verbally responded to 11 questions : eye straining, eye paining, dry eye, sore eye, watery eye, photophobia, blur vision, diplopia, eye fatigue, headache, and dizziness with scale 0 to 3 at each measurement while watching 3D and 2D TV. Results: The mean scores of visual fatigue were $2.08{\pm}2.14$, $3.19{\pm}3.02$, $3.40{\pm}3.37$, $3.53{\pm}3.07 $for after 5 minutes, 25 minutes, 45 minutes, and 65 minutes respectively for 3D TV, and $0.40{\pm}1.03$, $0.22{\pm}0.70$, $0.22{\pm}0.58$, and $0.17{\pm}0.52$ after 25, 45, and 65 minutes respectively for 2D TV. Visual fatigue for watching 3D TV was significantly higher than for watching 2D TV at all measurements sessions (paired t-test, p < 0.001). The visual fatigue significantly increased during watching 3D TV for 65 minutes (p < 0.001, RM-ANOVA). The visual fatigue during watching 3D TV was significantly increased until 25 minutes (paired t-test, p < 0.001), stable after that. For correlation between visual fatigue and 3D watching experience, the more 3D watching experiences were significantly the less visual fatigues in photophobia, blur vision, diplopic and dizzy symptoms (ANOVA, all F(1, 96) = 4.500, all p < 0.05), but there was not significantly different in the other symptoms (ANOVA, F (1, 96) = 2.123, p = 0.148). Conclusions: Visual fatigue for watching 3D TV was higher than for watching 2D TV, increase by 25 minutes. It was different by symptoms for correlation between visual fatigue and 3D watching experience.

Usefulness of wearing pocket dosimeter in nuclear medicine (핵의학 영상검사에서 Pocket dosimeter 착용의 유용성 평가)

  • Kim, Young-Bin;Lee, Eun-Ji;Kim, Kun-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.25-28
    • /
    • 2011
  • Purpose: The aim of study is to find accuracy of pocket dosimeter in measuring exposed dose in compared with survey meter and to compare exposed dose according as Nuclear medicine exams. Materials and Method: First, radiation dose to point source(185 MBq,370 MBq, ${\ldots}$, 1665 MBq, 1850 MBq) were measured in using a pocket dosimeter and a survey meter. Second, radiation dose to 12 patients injected $^{18}F$-FDG 370 MBq were measured in using a pocket dosimeter and a survey meter. Third, radiation dose to 10 patients injected $^{99m}Tc$-DPD 925 MBq were measured in using a pocket dosimeter and a surveymeter. Result: The average is $70.12{\pm}39.36{\mu}Sv/h$ in measurement of point source with Surveymeter and $5{\pm}3.06{\mu}Sv$ in measurement of point source with Pocket dosimeter. The average is $25.04{\pm}6.16{\mu}Sv/h$ in measurement of PET/CT patients with Surveymeter and $2.41{\pm}0.51{\mu}Sv$ in measurement of PET/CT with Pocket dosimeter. The average is $8.58{\pm}0.96{\mu}Sv/h$ in measurement of Bone Scan patients with Surveymeter and $1{\mu}Sv$ in measurement of Bone Scan patients with Pocket dosimeter. Significant difference found between Survey meter value and Pocket dosimeter value in all experimentation (p<0.001). Conclusion: Accoring to rusult Wearing Pocket dosimeter is usefulnee in manerage of exposed dose in nucler medicine exams.

  • PDF

Comparison of Sleep Indices between Both Wrist Actigraphies and Nocturnal Polysomnography (양측 손목에 착용한 Actigraphy와 야간수면다원검사 간의 수면지수 비교)

  • Shin, Byung-Hak;Park, Doo-Heum;Lee, Hyun-Kwon;Yu, Jae-Hak;Ryu, Seung-Ho;Ha, Ji-Hyeon;Shin, Hyeon-Sil;Hong, Seok-Chan
    • Sleep Medicine and Psychophysiology
    • /
    • v.14 no.1
    • /
    • pp.20-25
    • /
    • 2007
  • The present study compared the actigraphic indices between both wrist actigraphies (WATGs), and the sleep estimates between each WATG and nocturnal polysomnography (NPSG) to assess their differences and consistencies. We studied 22 right-handed subjects (mean age $43.9{\pm}13.3\;years$, M:F=14:8) with untreated primary sleep disorders (primary insomnia=8, simple snorer=2, obstructive sleep apnea=12) undergone by overnight both WATGs and NPSG, simultaneously. Comparison and correlation were analyzed between right and left wrist actigraphic data. In the sleep estimates of both WATGs and NPSG, each WATG was compared and correlated with NPSG in sleep period time (SPT), total sleep time (TST), sleep latency (SL), sleep efficiency (SE) and wake time (WT). Sleep indices between both WATGs showed significant positive correlations with no correlations in SL and fragmentation index (FI). There were no differences in sleep indices between both WATGs. SPTs of both WATGs, SL of left WATG, and TST of right WATG showed positively significant correlations, and SE of right WATG did negatively significant correlation in sleep indices between each WATG and NPSG. As each WATG was compared to PSG, SPTs of both WATGs and WT of right WATG were decreased, and TST and SE of right WATG and SL of left WATG were increased. Inconsistent SL and FI between both WATGs indicate that the activities between both WATGs can differentially happen during wake or arousal. Inconsistent sleep estimates between each WATG and NPSG may indicate the limited usefulness in measuring and analyzing one-night sleep by using WATG.

  • PDF

Factors Affecting Self-efficacy of Cardiopulmonary Resuscitation(CPR) in Adults (일반 성인들의 심폐소생술 자기효능감에 미치는 영향 요인)

  • Jeon, So Youn
    • Journal of agricultural medicine and community health
    • /
    • v.44 no.3
    • /
    • pp.124-137
    • /
    • 2019
  • Objectives: The purpose of this study was factors affecting self-efficacy of cardiopulmonary resuscitation (CPR) in adults. Therefore, the provide basic data for strategy development to improve the performance rate of bystander CPR. Methods: The data were collected from 164,165 adults of the 2016 Korean Community Health Survey. The survey method was 1:1 interview with households, and the survey period was from August 16, 2016 to October 31, 2016. The survey variables were as follows: self-efficacy of CPR, awareness of CPR, training experience of CPR, demographic characteristics, medical characteristics, health promoting behaviors, and safety practices. Results: The rate of self-efficacy of CPR in adults was 60.6%. Factors affecting self-efficacy of CPR were age, sex, residence, education level, occupation, marital status, any CPR training, CPR training within the last 2 years, CPR training with manikin within the last 2 years, emergency room visit within the last 1 year, physical activity status, drive a bicycle, seat belts on rear seat, seat belts when riding a bus were statistically significant. Conclusions: In conclusion, in order to improve the self-efficacy of CPR in adults, the recent experience rate of CPR education, the practice rate of health promotion behavior, and the practice rate of safety behavior should be improved. The government should expand the provision of education programs to improve the self-efficacy of CPR and actively prepare national-level public advertisements strategies.

Association between Perceived Susceptibility to Fine Dust Exposure and Wearing Masks, Attitude toward Respiratory Disease Prevention Education in Farmers (농업인의 미세먼지 노출에 대한 인지된 감수성과 마스크 착용 및 호흡기질환 예방교육 참여 태도와의 연관성)

  • Jung, HyeJeong;Lee, YunJin;Lee, SooYeon;Han, JiYoung;Kim, YangWoo;Lee, Soo-Jin
    • Journal of agricultural medicine and community health
    • /
    • v.46 no.2
    • /
    • pp.78-88
    • /
    • 2021
  • Objectives: This study aimed to investigate health risk awareness pertaining to fine dust exposure and the use of face masks in farmers, as well as their attitude toward education regarding fine dust-related respiratory disease prevention. Methods: In total, 295 farmers were interviewed in a survey using a structured questionnaire to obtain data on general characteristics, farming-related characteristics, health risk awareness pertaining to fine dust exposure, attitude toward education on fine dust-related respiratory disease prevention and the use of face masks. This study was analyzed the correlation between the perceived susceptibility to fine dust exposure and willingness to participate in education on fine dust-related respiratory disease prevention. Results: The mean score for perceived susceptibility to fine dust exposure was 3.8 (out of 5), and the participants were highly willing to receive education on fine dust-related respiratory disease prevention. In Multiple response analysis of reactions to exposure to fine dust generated during work, 221 participants responded that they practiced at least one preventive action; participants gave a positive response to "wearing masks" (56.1%), "personal hygiene, such as hand washing." (52.9%). In terms of education methods, 94 (33.6%) participants preferred to learn online or via text messages. Conclusions: The significant correlation between the perceived susceptibility to fine dust exposure and willingness to participate in education on fine dust-related respiratory disease prevention shows the importance of promoting education on prevention. The results of this study can help understand as reference for education on fine dust-related respiratory disease prevention.

Evaluation of the Usefulness of Virtual Reality Equipment for Relieving Patients' Anxiety during Whole-Body Bone Scan (전신 뼈 검사 환자의 불안감 해소를 위한 가상현실 장비의 유용성 평가)

  • Kim, Hae-Rin;Kim, Jung-Yul;Lee, Seung-Jae;Baek, Song-Ee;Kim, Jin-Gu;Kim, Ga-Yoon;Nam-Koong, Hyuk;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.27-32
    • /
    • 2022
  • Purpose When performing a whole-body bone scan, many patients are experiencing psychological difficulties due to the close distance to the detector. Recently, in the medical field, there is a report that using virtual reality (VR) equipment can give pain relief to pediatric patients with weak concentration or patients receiving severe treatment through a distraction method. Therefore, in this paper, VR equipment was used to provide psychological stability to patients during nuclear medicine tests, and it is intended to evaluate whether it can be used in clinical practice. Materials and Methods As VR equipment, ALLIP Z6 VR (ALLIP, Korea) was used and the experiment was conducted after connecting to a mobile phone. The subjects were 30 patients who underwent whole-body bone examination from September 1, 2021 to September 30, 2021. After intravenous injection of 99mTc-HDP, 3 to 6 hours later, VR equipment was put on and whole body images were obtained. After the test, a survey was conducted, and a Likert scale of 5 points was used for psychological anxiety and satisfaction with VR equipment. Hypothesis verification and reliability of the survey were analyzed using SPSS Statistics 25 (IBM, Corp., Armonk, NY, USA). Results Anxiety about the existing whole-body bone test was 3.03±1.53, whereas that of anxiety after wearing VR equipment was 2.0±1.21, indicating that anxiety decreased to 34%. When regression analysis of the effect of the patient's concentration on VR equipment on anxiety about the test, the B value was 0.750 (P<0.01) and the t value was 6.181 (P<0.01). decreased and showed an influence of 75%. In addition, overall satisfaction with VR equipment was 3.76±1.28, and the intention to reuse was 66%. The Cronbach α value of the reliability coefficient of the questionnaire was 0.901. Conclusion When using VR equipment, patients' attention was dispersed, anxiety was reduced, and psychological stability was found. In the future, as VR equipment technology develops, it is thought that if the equipment can be miniaturized and the resolution of VR content images is increased, it can be used in various clinical settings if it provides more realistic stability to the patient.

Transilluminated Powered Phlebectomy Using Arthroscopic Equipment in Varicose Vein of Lower Extremities (하지정맥류에서 관절경 장비를 이용한 광투시 전동형 정맥적출술)

  • 박형주;이철세;이길노;이석열
    • Journal of Chest Surgery
    • /
    • v.36 no.6
    • /
    • pp.391-396
    • /
    • 2003
  • Background: Recently transilluminated powered phlebectomy was introduced and used as a method of surgical treatment for varicose vein in lower extremities. The advantage of transilluminated powered phlebectomy are minimal scar and good cosmetic effect. However, the disadvantages of transilluminated powered phlebectomy is that a high priced Trivex system must be used which increases the patient's expenses. Therefore, we performed a transilluminated powered phlebectomy using an existing arthroscopic equipment instead of Trivex system and observed the effect of treatment and efficiency of the treatment. Material and Method: From March, 2000 to February, 2003, 78 patients (113 limbs) underwent transilluminated powered phlebectomy with an arthroscopic equipment. Patient's disease history, the number of operative scars and complications were reviewed. Result: The operation was performed in 133 limbs of the 78 patients (34 men, 44 women) and the age of patients were ranged from 16 to 72 years with mean age of 41.8 years. Operative time ranged from 20 to 65 minutes (average 48.7 minutes) per limb. The number of operative scar per limb from 2 to 7 (average 4.9). Postoperative complications are transient ecchymosis (78 cases) that desappeared spontaneously, edema persisting longer than 3 weeks (6 cases), remnant varicose vein (4 cases), skin perforation during operative procedure (2 cases), and contact dermatitis due to compression stocking (4 cases) The mean hospitalization day was 3.09 days. Subjective mean satisfaction degree of operation by the patients using a visual analogue scale was 92.6%. Conclusion: Our findings demonstrated that transilluminated powered phleectomy using arthroscopic equipment was possible and had good cosmetic results with acceptable complications.

Research of Difference between the Refractive Powers by Autorefractometer and the Prescription using Phoropter (자동 굴절력계의 굴절력값과 포롭터를 이용한 처방값의 차이에 관한 연구)

  • Lee, Ju-Whan;Lee, Koo-Seok;Hong, Hyung-Ki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.231-237
    • /
    • 2014
  • Purpose: This study is research of the conditions which causes difference between the refractive power of the measurement of autorefractometer and the prescription using phoropter. Methods: Autorefractometer (SR-7000) and phoroptor (AV-9000) were used to measure 60 eyes of 30 participants who had no eye diseases and wore the corrective lens due to Ametropia. To prevent the dependence of the prescription value of the refractive power on the testers, two testers measured the refractive power of the eyes of the participants at the same measuring conditions. Results: Statistically, the prescribed values of the refractive power by two testers were not significantly different. Most of the prescribed values of the refractive power were smaller than the refractive power by autorefractometer In case of myopic eyes, the difference between refractive powers by the measurement of autorefractometer and the prescription using phoropter showed the trend of increase as the spherical refractive power became larger. The result was analyzed by the range of the different cylindrical refractive power for the myopic astigmatic eyes. In this case, the difference between refractive powers showed the trend of decrease as the cylindrical refractive power became larger. Conclusions: No difference between the prescribed value by two testers was observed. In case of myopic or myopic astigmatic eyes, the difference between refractive powers by autorefractometer and the prescription were measured to be approximately proportional to the refractive powers of ametropic eyes. As the this difference become larger for the participant who needs the lens of larger refractive power, additional caution is needed in the prescription of the refractive power of the corrective lens.

Development of Multipoint Simultaneous Full-duplex Team Communication Module for SCBA (SCBA 면체용 다자간 동시 양방향 팀 통신모듈 개발)

  • Kim, Si-Kuk;Choi, Su-Gil;Lim, Woo-Sub;Han, Yong-Taek
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.165-172
    • /
    • 2019
  • This study presents the design and manufacture of a self-contained breathing apparatus SCBA wireless communication module with a multipoint simultaneous full-duplex communication system to enable communication between team members wearing the SCBA system. It is necessary for fire-fighters to wear the SCBA system during extinguishing and rescue work at the fire site. Evaluation of the team communication module confirmed the feasibility of communication over more than 500 m in the test condition based on the line of sight. By implementing the Ad-hoc function, it was confirmed that the communication distance could be extended to 128 m by automatic routing up to 3 hoc. The vertical distance inside the building for successful communication was up to the 5th floor in the open staircase and up to the 3rd floor in the partitioned staircase. Furthermore, the performance testing of the communication module assuming a fire situation, confirmed that five team members correctly recognized the standard abbreviation of fire and wireless communication without a separate PTT key operation. In addition, the flame resistance was verified by exposing the module to a flame at 950 ± 50 ℃ for 5 s and then immediately extinguishing the flame.