• Title/Summary/Keyword: 착용성평가

Search Result 261, Processing Time 0.024 seconds

A Study of the Basic Design for Smart Clothing based on Measurement of the Respiration (호흡 측정 기능의 스마트 의류를 위한 기초 디자인 연구)

  • Cho, Ha Kyung;Min, Se Dong
    • Science of Emotion and Sensibility
    • /
    • v.15 no.4
    • /
    • pp.415-424
    • /
    • 2012
  • According to introduction of Well-Being lifestyle and ageing society, vital sign monitoring system which can be continued measurement of vital sign has been increased their important in field of the healthcare. Under this trend, Respiration monitoring system has been studied and developed in a various way to apply continued monitoring and non-conscious monitoring system. But, Study of the respiration monitoring system based on consumer needs and usability test is insufficient. In this study, Textile capacitive pressure sensor(TCPS) of belt type was developed and tested it's utility and subjective sensibility. TCPS measures respiration signals and can be derived in real time monitoring. As a result, monitoring respiration using textile capacitive pressure sensor offers a promising possibility of convenient measurement of respiration rate (correlation (r=0.9553, p<0.0001). In the result of usability and wearability test, all of categorizes(perceived change, wearability, movement, facility of management, usefulness) were received favorable evaluation on usability test( mean value : 3.8), and suitable location of TCPS in the clothing is deriven on the abdomen part. According to synthetical results, Basic smart clothing design based on respiration monitoring system is proposed.

  • PDF

The Effects of Knee Sleeve with a Stimulation of Golgi Tendon Organ on One Leg Standing and Proprioception (무릎 슬리브 착용과 골지 건 기관 자극이 한 발 서기 동작과 고유수용성 감각에 미치는 영향)

  • Jeong, BoRa;Chang, YoonHee;Kim, GyuSeok;Ryu, JeiCheong;Ko, Chang-Yong
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.4
    • /
    • pp.323-330
    • /
    • 2017
  • Knee sleeve has been used for prevention of sport injuries as well as rehabilitation. To investigate prevention of sport injuries of knee sleeve, it is important to evaluate balance associated with proprioception. The aim of this study was to evaluate the effects of a knee sleeve with a pad that stimulate to golgi tendon organ (GTO_PAD) on proprioception and balance ability. Five healthy males were participated for the study. They were asked to reenact target angle with Biodex and perform one leg standing with knee sleeve and knee sleeve with GTO_PAD. There was no significant difference in %Target angle, but the value of %Target angle was higher in subjects wearing knee sleeve with GTO_PAD than only knee sleeve, except for one subject. During one leg standing, time duration was increased in subjects wearing knee sleeve with GTO_PAD. The length of center of pressure in x-axis (COPx) and COP in y-axis (COPy) were decreased when wearing knee sleeve with GTO_PAD (COPx : $162.06{\pm}58.99mm$ in knee sleeve vs. $149.03{\pm}45.30mm$ in knee sleeve with GTO_PAD, COPy : $310.79{\pm}115.89mm$ in knee sleeve, $291.57{\pm}76.53mm$ in knee sleeve with GTO_PAD). There was significant differences in INI_transition, steady, and LAT_transition phase (all, p < 0.05). These findings support that wearing knee sleeve with GTO_PAD might enhance proprioception and balance.

Investigation on Users' Perception and Certification Status and Donning of Smoke Masks (방연마스크에 대한 사용자 인식, 인증 현황 및 착용성 조사)

  • Hyunwoo Son;Yeongeun Park;Eungwoo Lee;Eunji Kim;Youngbo Choi
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.68-73
    • /
    • 2023
  • Smoke masks have attracted great interests and have been supplied widely for the improvement of the safety during fire evacuation. However, there is not sufficient research on the practical utility, certification status and easy-donning about commercial smoke masks, therefore it is difficult to determine the actual usefulness of the smoke masks. In this study, we conducted a survey on users' perceptions and experiences about the smoke masks, and investigated the status of certification of 54 commercial smoke masks. We also performed donning tests and examined degrees of discomfort for 4 types of the smoke masks. Although 22% of 235 respondents had experienced the smoke masks before the test, and 23% of the respondents did not know the smoke masks, 93% of the respondents expected that the smoke masks could protect users from fire smokes and toxic gases. It was found that 41% of the commercial smoke masks did not certify according to domestic or overseas performance standards. Most certification standards have not effectively regulated maximum wearing time for the smoke masks. Only ASTM E 2952 and KFIS 024 had specific standards for the maximum wearing time of 30 s. As a result of donning tests for 4 types of smoke masks, the wearing time of the hood-type mask and self-contained smoke mask exceeded 30 s, therefore these types of smoke masks might increase the required safe evacuation time. On the other hand, it was also found that short education about the donning could reduce the wearing time by 19% and numbers of improper wearing by 89%.

An Exploratory Study on the Development of a Healthcare Smart Clothing for Measurement of Body Composition (체성분 측정용 스마트 의류 개발의 가능성 탐색)

  • Mun, Hui-Seong;Jo, Hyeon-Seung;Park, Seon-Hyeong;Lee, Ju-Hyeon;Jeong, Hyo-Il
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2007.05a
    • /
    • pp.42-44
    • /
    • 2007
  • 본 연구에서는 체성분 측정용 스마트 의류의 프로토타입을 개발하고 평가함으로써 헬스케어 의류로써의 개발 가능성을 탐색하고자 하였다. 직물 전극을 사용하여 두 가지 타입으로 개발된 실험의복을 피험자에게 착용하도록 한 후 자세의 변화 및 1차 착용, 탈의 후 2차 착용에 따른 체성분을 측정한 결과, 동일 자세 내에서는 의복 타입 및 1, 2차 반복 착용에 관계없이 비교적 일관성 있는 임피던스 측정치를 얻을 수 있었으며, 착용자의 신체 부위별 측정도 가능한 것으로 분석되었다.

  • PDF

Thermophysiological Responses of Wearing Safety Hat for Working at a Hot Environment (서열환경하에서 안전모 착용시의 인체생리학적 반응)

  • 박소진;김희은
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.1
    • /
    • pp.74-82
    • /
    • 2002
  • The present study is aimed to investigate the effect of the safety hat on the balance of body temperature by observation of the physiological response under hot working environment. The experiment was carried out in a climate chamber of 3$0^{\circ}C$, 50%RH for 70 minutes. To compare the two kinds of safety hat, 5 healthy male subjects worn safety hat without hole (called 'without hole') or safety hat with hole (called 'with hole') according to a randomized cross-over design. The main results of this study are as fellows: Rectal temperature and heart rate were significantly lower level in 'with hole'than in 'without hole'. The mean skin temperature was significantly higher in 'without hole'than in 'with hole'. Blood pressure were significantly low in 'with hole'. Sweat rate which was measured by weight loss before and after experiment was higher in 'without hole'. In subjective ratings, subjects replied more hot, more uncomfortable and more wet, they felt more fatigue in condition of 'without hole'. Work ability which was measured by a grip strength dynamometer was higher in 'with hole'. Safety hat which can be used for safety of the brain in work place is meaningful device of behavioral thermoregulatory response under the hot working environment. The safety hat which is designed for proper ventilation and hygiene can maintain the homeostasis of body temperature by releasing body temperature efficiently.

Implementation and Evaluation of Eyepatch-type Obstructive Sleep Apnea Detection System (안대형 폐쇄성 수면 무호흡증 검출시스템의 구현 및 평가)

  • Lee, Chang-Hoon;Kim, Byeong-Ju;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.1004-1005
    • /
    • 2013
  • 본 연구에서는 폐쇄성 수면 무호흡증 환자를 대상으로 착용의 불편함을 최소화하고 수면 중 지속적인 모니터링이 가능한 안대형 폐쇄성 수면 무호흡증 검출시스템을 구현하였다. 이를 위하여 숙면을 돕기 위해서 착용하는 안대의 코 부근에 온도센서를 부착하여 실제 호흡에 따른 온도 변화를 감지하였다. 폐쇄성 수면 무호흡증 환자의 경우 수면 중 불안정한 호흡이 온도의 변화로 반영되기 때문에 이를 검출하기 위함이다. 또한 검출된 온도 변화는 안대에 내장된 제어부 및 블루투스 모듈을 통해 스마트폰으로 전송되어진다. 전송된 데이터는 안드로이드 기반의 어플리케이션을 구현하여 실시간으로 모니터링이 가능하며, 구현된 어플리케이션은 위험상황 인지 및 알림, 일월별 관리 기능을 포함하고 있다. 구현된 시스템의 성능 평가를 위하여 대학생 5명을 대상으로 임의의 호흡 변화에 대한 실험 프로토콜을 작성하여 실험을 수행하였으며, 그 결과 호흡을 중단하였을 시 온도 변화를 통해 검출이 가능함을 확인하였다.

  • PDF

Dosimetric Analysis for Human Exposure to Body-Mounted Wireless Devices (인체 착용형 휴대 단말기에 대한 노출량 해석 연구)

  • Park Min-Young;Ko Chae-Ok;Kim Jeong-Ran;Pack Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.2 s.105
    • /
    • pp.207-212
    • /
    • 2006
  • A variety of wireless devices are commercially available now. Most of studies, however, have been directed to the biological effects of mobile-phone EMF. In this paper, dosimetric analysis for wireless devices of head-mounted display type and a wristwatch type were made to investigate possible biological effects of these devices. SAR(Specific Absorption Rate) distributions were calculated using FDTD(Finite Difference Time Domain) method, for adult human models such as standard Korean human model and VHP(Visible Human Project) model, as well as scaled child models. Measurements were also performed for SAM phantom wearing a simplified prototype for a wireless device for validation of the simulation results. It has been found that children are more vulnerable to such exposure, and these devices could cause some biological effects even for relatively lower power compared to conventional mobile pones.

A Study on Performance Evaluation for Electrocardiography Signal Measurement Electrode based on Conductive Fabric (전도성 섬유 기반 심전도 전극의 성능 평가에 관한 연구)

  • Kang, Bo Kyu;Yoo, Sun Kook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.210-220
    • /
    • 2013
  • Recently, as we move toward a society with an increasingly aged population, wearable U-health devices in various shapes with smart wear have been developed in order to conveniently measure health variables without using hands in daily life or at home. However, the problem is that only supply of the wearable U-health devices is focused and its applicable devices are studied and developed, which has resulted in lack of awareness of importance of performance evaluation. In this study, two electrodes were fabricated using conductive fabric which can be used as electrode if attached to wearable U-health devices or smart wear in order to measure ECG signal. Two electrodes those were fabricated using conductive fabric were compared the correlation, impedance and CMRR with patch typed Ag-AgCl electrode-normally used for measurement of ECG signal, so that the study would find out if the fabricated electrode can be used with the wearable U-health devices by testing and evaluating performances.

A Development of the Lightweight Wearable Robot with Carbon Fiber Composite (탄소섬유 복합재를 이용한 경량 착용형 로봇의 개발)

  • Lee, Jeayoul;Jeon, Kwangwoo;Choi, Jeayeon;Chung, Goobong;Suh, Jinho;Choi, Ilseob;Shin, Kwangbok
    • Composites Research
    • /
    • v.28 no.3
    • /
    • pp.81-88
    • /
    • 2015
  • In this paper, we evaluate structural integrity of the wearable robot by using finite element analysis, which is made of CFRP(Carbon Fiber Reinforced Plastic) composite materials to be lightened. On the basis of the ASTM(American Standard Test Method), mechanical tests of the material are carried out in tensile, compressive and shear test for analytical evaluation. With the tested composite material, the main frame and two femoral frames of the robot is redesigned to satisfy the lightening design requirements. It is verified with the structural analysis that the redesigned frames are good for the part of the wearable robot.