• Title/Summary/Keyword: 차폐체

Search Result 326, Processing Time 0.023 seconds

Degradation of Pesticides in Wastewater Using Plasma Process Coupled with Photocatalyst (광촉매를 병합한 플라즈마 공정을 이용한 폐수에 함유된 살충제 분해)

  • Jang, Doo Il;Kim, Kil-Seong;Hyun, Young Jin
    • Applied Chemistry for Engineering
    • /
    • v.24 no.1
    • /
    • pp.87-92
    • /
    • 2013
  • Nonthermal plasma hybridized with photocatalysts is proven to be an effective tool to degrade toxic organics in wastewater. In this study, a specially designed dielectric barrier discharge (DBD) plasma system combined with photocatalysts was applied to decompose pestiticides such as dichlorovos, carbofuran and methidathon, which are frequently used in the golf courses and the orange plantations. The degradations of the pesticides in single and coupled systems were evaluated. The single system was used with ozone plasma which consisted of electrons, radicals, ions produced by oxygen gas and air, with and without ultra-violet (UV) irradiation, respectively. The coupled systems utilized the air-derived ozone plasma combined with zinc oxide, titanium dioxide and graphite oxide photocatalyst activated by UV. The graphite oxide was synthesized by a modified Hummer's method and characterized using FTIR spectrometer. It was elucidated that the plasma reaction with graphite oxide (0.01 g/L) brought about almost 100% of degradation degrees for dichlorovos and carbofuran in 60 min, as compared with the performances showed by no catalyst condition. The photocatalyst-hybridized plasma in the presence of UV irradiation was proven to be an effective alternative for degrading pesticides.

Measurement of Breast Skin Dose According to Shield Thickness During Whole Spine Scanography Using Digital Radiography System (Digital Radiography 시스템을 사용하여 전 척추검사 시 차폐체 두께에 따른 유방피부선량 측정)

  • Nam, Soon-Kwon;Choi, Joon-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.1
    • /
    • pp.25-30
    • /
    • 2019
  • Whole Spine Scanography (WSS) using the Digital Radiography (DR) system is an examination that requires whole body X-ray exposure, which involves more exposure to radiation for patients than other general radiographies. This can affect the occurrence of breast cancer. This research measured radiation dose when breasts were shield and not shield using the Auto Exposure Control (AEC) mode. The radiation dose without a shield was 1.540 mGy, and that using a collimator was measured 0.506 mGy. Moreover, 0.733 mGy was measured when 1 shield (0.3 mm) was used, and $0.523{\mu}Gy$ when 5 of them (1.5 mm) were used. The results showed that the radiation dose with 5 shields and the radiation dose with a collimator were similar. Moreover, 0.233 mGy was measured when 8 shields (2.4 mm) were used. The standard deviation were 0.081 when using collimator and 0.014 when 5 shields were used. Also, when 8 shields were used, it was found to be 0.002. Most patients who go under a scoliosis test are children or young people who are highly sensitive to radiation. In the research results, the case where the organs sensitive to radiation, women's breasts, were shielded showed more distinct differences compared to without shields. It is considered that using shields can provide more constant shield than using a collimator and lower the risk of breast cancer caused by exposure to radiation.

Direction detection technique of radioactive contaminants based on rotating collimator (회전형 콜리메이터 기반 방사능 오염원의 방향탐지 기법)

  • Hwang, Young-Gwan;Song, Keun-Young;Lee, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.11
    • /
    • pp.1519-1527
    • /
    • 2020
  • AGeneral radiation measuring devices have been developed in the form of spatial dose rate detection devices that measure dose rates to radioactive contaminant and 2D or 3D imaging devices for radioactive contamination information. Each of these radiation detection techniques has advantages. The advantages of both detection devices are necessary to minimize personal injury and rapid decontamination in the area of a radioactive accident. In this paper, we proposed a technique that can measure the dose rate and direction information about the radioactive pollutant source in real time using a detection sensor, a rotating body, and a directional shield for radioactive pollutant detection. The rotational-based detection device is configured to check the dose rate and direction using the location information of the rotator and measurement value. We proposed a measurement technique for vertical and horizontal directions through multiple holes. It was confirmed that the measurement error for direction information was less than 1% when detected in the horizontal direction.

A Study on the Setting of Examination Limits for Radiographers in Medical Institutions (의료기관 내 방사선사의 검사 한도 설정에 관한 연구)

  • Jeong-Ho Kim;Gap-Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.401-410
    • /
    • 2023
  • A radiographer is a job in charge of diagnostic imaging equipment, and must contribute to the promotion of public health by suggesting an appropriate level of work. To this end, we intend to present an appropriate level of work through evaluation of human harm according to work, statistical evaluation through questionnaires, and domestic and international trends. In the case of human harm evaluation, considering radiation exposure, 42.6%, shield work, 69.7%, and in the case of magnetic resonance imaging, the maximum length of stay in the examination room should be adjusted to 15 minutes and not exceed 30 times. According to the survey statistics, it was confirmed that the physical and mental burden increased due to the high workload and difficulty compared to working hours. Based on domestic and international trends, it is necessary to adjust the examination standards for domestic radiographers to 36.8% to promote national health through qualitative improvement of radiological examinations. something to do.

Fire-Protective Coating for Polymer Construction Materials using Two-dimensional Nanomaterials (2차원 나노소재를 활용한 고분자 건축자재의 난연코팅기술 개발)

  • Kim, Hanim
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.183-190
    • /
    • 2024
  • An environmentally-friendly nanocoating method that effectively adds flame retardant(FR) and gas shielding properties to combustible polymeric construction materials such as flexible polyurethane (PU) foam was studied. Naturally-driven two-dimensional(2D) nanomaterials such as graphene oxide (GO) can exhibit liquid crystalline (LC) properties in aqueous solutions, enabling uniform coatings on the various substrates including 3D-porous foams. LC phase-assisted coating serves as 3D-scaffold, facilitating the introduction of small molecules having antioxidant capabilities such as dopamine which is to form uniformly stacked FR coating. Additionally, the structural characteristics of the 2D-materials can effectively hinder the migration of toxic gases and flammable substances in the gas phase generated during combustion. This LC phase flame retardant coating technology could be a new approach to provide environmentally friendly and effective flame retardant and gas barrier properties to various types of polymeric materials.

Analysis of Shielding Characteristics on the Cylindrical Lossy Multilayered Dielectric (손실이 있는 원통형 다층 유전체의 차폐특성 해석)

  • Ryu, Hwang;Lee, Sang-Seul
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.11
    • /
    • pp.57-61
    • /
    • 1992
  • In this paper, the shielding characteristics of a cylindrical multilayered dielectric are analyzed. In order to evaluate shielding effects, we consider the case that plane waves are incident upon an infinitely long cylindrical multilayered dielectric which surrounds a conductor core. For perfect and lossy dielectric distributions, total induced currents at the conductor surface are computed. It was found from those results that electromagnetic characteristics of the multilayered dielectric are largely dependent on dielectric distribution.

  • PDF

Analysis of Electromagnetic Shielding Characteristics of the Spherical Multilayered Dielectric (구형 다층 유전체의 전자파 차폐특성 해석)

  • Ryu, Hwang;Lee, Sang-Seul
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.7
    • /
    • pp.26-31
    • /
    • 1993
  • We have analyzed shielding characteristics of the spherical multilayered dielectric, with the assumption that the inner part of the model is filled with the perfect conductor whose radius is varied from 0.2.lambda. to 1.0.lambda. and the outer part of the conducting sphere is covered by a lossy multilayered dielectric. Variation of shielding effects have been examined as the function of parameter of the dielectric layer and the radius of the conducting sphere.

  • PDF

Electrochemical Polymerization of Conducting PVC-g-Poly(methyl aniline) Copolymer and Properties (전기화학 중합에 의한 전도성 PVC-g-Poly(methyl aniline) 공중합체의 합성 및 성질)

  • 조현석;박연흠;박종민
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2002.04a
    • /
    • pp.355-358
    • /
    • 2002
  • 고분자가 절연재료로서 사용되는 이유는 전기를 통하지 않는 절연특성을 지니고 있기 때문이며 이러한 성질은 고분자가 금속재료와 구별되는 가장 큰 특징이다. 그러나 1964년 W. A. Little 이 발표한 공액 이중결합구조를 가진 화합물은 전도성 고분자가 될 수 있다는 가설을 바탕으로 전도성 고분자에 관한 많은 연구가 진행 중에 있다. 전도성 고분자는 절연체로서의 응용에만 한정되어왔던 기존 고분자물질들과 달리 가볍고 저렴하며 단일결합과 이중결합을 교대로 하고 있는 공액 고분자 구조를 가지고 있어 다양한 화학적 합성방법에 의해 전기전도도, 유전상수, 결정 등의 물리적 성질을 조절할 수 있으며, 금속의 전기적, 자기적, 광학적 특성과 고분자의 기계적 성질을 동시에 가지므로 배터리, 축전기, 트랜지스터, 광전소자, 전자파 차폐제 등 플라스틱 전자소재의 실용적으로 인해 산업체에서도 높은 관심의 대상이다. (중략)

  • PDF

Analysis of the shielded coplanar waveguide with multiple anisotropic substrates. (이방성 다층 유전체 기판을 갖는 차폐된 코프래너 도파관 해석)

  • 안광은;이상설
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.9
    • /
    • pp.1250-1256
    • /
    • 1995
  • In this paper, shielded suspended coplanar waveguide with multiple anisotropic substrates is analyzed by the point matching method in the quasi-TEM mode appoximation. The characteristic impedance and the effective dielectric constant are calculated by varying the width of center strip and gap between the center strip and the ground strip. And also the characteristic parameters are calculated as a function of ${\varepsilon}_{x}/{\varepsilon}_{y}$) and a permitivity of the support substrate. Approaching the ground strip to infinity, the values of the characteristic parameters are found to be in good agreement with the other results by variational method.

  • PDF

Development of Remote Visual Inspection Technology for CANDU Calandria & Internals (CANDU형 원전 칼란드리아 및 내장품 원격 육안검사 기술 개발)

  • Lee, Sang-Hoon;Kim, Han-Jong
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.4 no.2
    • /
    • pp.57-61
    • /
    • 2008
  • During the period of retubing work for the licensing renewal, the fuel channels, calandria tubes and feeders of CANDU Reactors will be replaced, and calandria visual examination will be performed. This period is a unique opportunity to inspect the inside of the calandria. The visual inspection for the calandria vessel and its internals of Wolsong NPP is scheduled for confirming the calandria integrity. The first visual inspection for the calandria is planned in Pt. Lepreau led by AECL. The visual inspection for Wolsong NPP, led by NETEC(Nuclear Engineering & Technology Institute) of KHNP, will employ 3D laser scanner and 3D CAD Mock-up for the first time in the world, in addition to a conventional video camera. The inspection system is composed of a robot with the 3D laser scanner, a video camera and a hardness meter.

  • PDF