• Title/Summary/Keyword: 차음측정

Search Result 90, Processing Time 0.024 seconds

Effect of Graphite Intercalation Compound on the Sound Absorption Coefficient and Sound Transmission Loss of Epoxy Composites (그라파이트 인터칼레이션 컴파운드가 에폭시 복합재료의 흡·차음성에 미치는 영향)

  • Lee, Byung-Chan;Park, Gyu-Dae;Choi, Sung-Kyu;Kim, Sung-Ryong
    • Composites Research
    • /
    • v.28 no.6
    • /
    • pp.389-394
    • /
    • 2015
  • The sound absorption coefficient and sound transmission loss of graphite intercalation compound (GIC) included epoxy composites were investigated. Epoxy resin was infused into the expanded GIC and the impedance tube method was employed to measure the sound absorption coefficient and sound transmission loss. Scanning electron microscopy photographs showed uniform distribution of the GIC in the epoxy matrix. The surface density of epoxy/GIC (20 wt%) composites decreased about 56% compared to that of pure epoxy. The sound absorption coefficient of composites increased about 3 times at the frequency range of 500~1000 Hz compared to the pure epoxy. The sound transmission loss of composites decreased with increasing the GIC content and it is attributed to the increase of pores in the composites.

Sound Transmission Loss Measurement for Sound Isolation Sheets by Two-Microphone Impedance Tube Method (두 개의 마이크로폰의 부착된 임피던스관법을 이용한 차음시트의 음향투과손실 측정)

  • Lee, Dong-Hoon;Yong, Ho-Taek;Lee, Seung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.1
    • /
    • pp.63-72
    • /
    • 2002
  • The main objective of this study is to propose a practical two-microphone impedance tube method to measure the sound transmission loss for flexible sound isolation sheets without the use of the time-consuming and expensive reverberation room. This method was based on the sound decomposition theory developed by Seybert using the spectral density functions of the incident and reflected sound waves. In order to verify the validity of the experimental results, the measured sound transmission losses from the proposed method were compared with the measured data from the reverberation room method and the calculated data from the theory satisfying the mass law of sound isolation material. The resulted trends of the sound transmission losses versus frequencies for several different sound isolation sheets were almost same for each other and agreed quite well in both methods except at some low frequency region. From the experimental results, it was found that the accuracy of sound isolation capability obtained by two-microphone impedance tube method depends upon the microphone spacing, the distance from the first microphone to the test sample surface and the test sample location.

Comparison of Sound Transmission through Single and Double-layer Polymer Panels (폴리머계 단일 및 이중구조 방음패널의 차음특성 비교분석)

  • Kim, Il-Ho;Lee, Ju Haeng;Son, Jin-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.9
    • /
    • pp.597-603
    • /
    • 2014
  • The aim of the present study is to compare sound performance depending on thickness, materials, and structure of polymer soundproof panels consisting of PC, PMMA, HDPE, and PP, respectively. As a result of comparing sound transmission loss (STL) of single layer panel made of four types of polymer, the better sound transmission loss was obtained in order of PC, PMMA, HDPE, and PP, which was obviously followed mass law. 8 mm of single panel showed 5~6 dB(A) greater STL than that of 4 mm panels and lower frequency for coincidence effect so that STL of 8 mm panels decreased around 4,000~5,000 Hz, indicating less STL of 4 mm panels than those of 8 mm. When it comes to structure, 4 mm panels with air layer appeared similar value of STL with 8 mm single panels under 300 Hz. In range of high frequency above 2,000 Hz, 4 mm panels with air layer performed better than 8 mm of single layer panel while resonance effects were observed at 500~630 Hz. It was found that these results could be practically utilized as fundamental data for noise barriers design considering the change to each condition.

Analysis of sorbic acid in tea-drink using isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) (동위원소희석 액체 크로마토그래피-질량분석법을 이용한 차음료 중의 소르빈산의 분석)

  • Ahn, Seong-Hee;Lee, In-Sun;Kim, Byung-Joo
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.25-32
    • /
    • 2012
  • Isotope dilution mass spectrometry (ID-MS) based on liquid chromatography tandem mass spectrometry (LC/MS/MS) was developed for the accurate determination of sorbic acid in tea-drink. An isotope analogue of sorbic acid, $^{13}C_2$-sorbic acid, was obtained by custom synthesis. MS was operated in the negative mode with selected reaction monitoring (SRM) mode of $[M-H]^-$ ${\rightarrow}$ $[M-CO_2H]^-$ channel at m/z 111 ${\rightarrow}$ 67 for sorbic acid and at m/z 113 ${\rightarrow}$ 68 for its isotope analogue. Chromatographic separation was accomplished with a C18 column and an isocratic mobile phase of 55% of 50 mM ammonium acetate (pH 4.5) and 45% of methanol. Homogeneous reference materials were prepared for validation of this method, including repeatability and reproducibility tests, by fortifying tea-drink with sorbic acid in our laboratory. Repeatability and reproducibility studies showed that the ID-LC/MS method is a reliable and reproducible method which provides less than 3.8% of relative standard deviation (RSD) for the analysis of sorbic acid.

Study on the Measurements of Architectural Acoustie by Cross-Correlation Methods (상호상관법에 의한 건축음향측정에 관한 연구)

  • Park, Byoung-Jeon;Shin, Young-Moo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.42-52
    • /
    • 1990
  • A method of measuring impulse response of acoustic system, two kinds of cross-correlation methods (the direct correlation method and the M-sequence modulation correlation method) were applied. According to the direct correlation method, by using stationary random noise source and by calculating the cross-correlation function between the sourece and the output signal, equivalent impulse response can be obtained not being influenced by the back ground noises. By applying this method, the measurement of echo-time patterns in rooms and oblique incident sound absorption characteristics of sound absorbing materials was carried out. In the case of the M-sequence modulation correlation method which was contrived by Aoshima, an intermittent random nosie modulated by M-sequence signal is used as the source signal, and the cross-correlation function between the M-sequence signal and the squared output signal is calculated. According to this method, equivalent energy impulse response (squared impulse response) of te propagation system can be obtained without being influenced by the back ground noises and the air fluctuation caused by wind. As the applcaition of this measuring method to the architectural acoustics, the meaurements of echo-time patterns, reverberation decays and sound pressure lev디 distributions in rooms and sound insulation efficiencies in buildings were carried out. From these experimental studies, it has been found that this M-sequence modulation correlation method is markedly useful especially for the field masurement of sound insulation under high back ground noise condition.

  • PDF

A Study on Tunneling Effect in Sound Transmission Loss Measurement (차음성능 측정시 터널링 효과에 관한 연구)

  • Kim, Bong-Ki;Kim, Jae-Seung;Kim, Hyun-Sil;Kang, Hyun-Ju;Kim, Sang-Ryul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.1E
    • /
    • pp.24-30
    • /
    • 2004
  • This study is aimed to evaluate a tunneling effect in the laboratory measurement of sound transmission loss. Based on the formulation for sound transmission loss of a finite panel in the presence of tunnel, variations of the sound transmission loss with the parameters of panel location and tunnel depth are investigated. In comparison with the transmission loss of a finite plate in an infinite rigid baffle, the maximum difference occurs in the laboratory measurement when the panel is placed at the center of the tunnel, while a better estimation of true transmission loss is obtained when the panel is located at either end.

A measuring technology of the absorption ratio and the transmission loss using the tube method (관내법을 이용한 흡.차음 성능 측정방법)

  • 이장명;김동률
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.659-663
    • /
    • 1998
  • To measure the absorption ratio and the transmission loss of a material, a usage of the reverberation room has been popular. However, the reverberation room is expensive to build it and, sometimes, test procedure is not easy. Therefore, to get the data of absorption ratio, several possible technologies has been proposed using the tube. Among these technologies, with the analysis of the spectral density, a convenient method has been introduced to measure both the absorption ratio and transmission loss. The measured data has been compared with the results of the measurement at the reverberation room.

  • PDF

An Experimental Study on the Field Measurement Methods of the Sound Insulation Performance of Window (현장에서의 창의 차음성능 측정방법에 관한 실험적 연구)

  • Lee, Ok-Kyun;Park, Hyeon-Ku;Choi, Hyung-Wook;Song, Hyuk;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.600-605
    • /
    • 2000
  • The aim of this study is to compare the sound insulation performances of window depending on the measurement methods through the field test and analyze the factors that affect the sound insulation performances. Four measurement methods which are specified in the Koran Standard 2235 and the International Standard 140-5 were selected for the study; the outdoor sound source method which is classified the l000mm method and the 10mm method, the indoor sound source method, and the ISO method. The result of this study is that the sound insulation performance of the windows was the best when measured according to the ISO method and the worst the indoor sound source method. Through the study it was found that the main factors affecting the sound insulation performance of the windows were the correction of the specimen's area and the equivalent sound absorption area of the receiving room.

  • PDF

저소음 도로 표면 개발의 필요성

  • 박철희
    • Journal of KSNVE
    • /
    • v.5 no.2
    • /
    • pp.147-152
    • /
    • 1995
  • 본 글에서는 현재 유럽과 우리나라와 유사한 도로사정을 가진 일본, 홍콩 에서 행해지고 있는 타이어/도로 소음에 관한 연구 실태와 그 자료를 소개함으로써 자동차 자체의 소음뿐 아니라 환경 소음 관절에서 간과할 수 없는, 타이어/도로 소음에도 관심을 가져야 할 이유를 제시하였다. 본문에서 살펴본 각 국의 노력과는 별도로 유럽 공동체(EC)는 1991년에 타이어/도로 접촉에 의해 발생하는 소음을 제한 할 수 있는 기준이 1995년 10월 이전에 결정될 수 있다고 발표하고 있으며, 이에 따라 도로 표면과 자동차의 종류에 따른 소음 측정 방법에 대한 표준을 연구하기 위하여 ISO내에 ISO/TC 43/SC 1/WG 33라는 그룹이 1991년 설립되었다. 이와 같이 유럽에선 과거부터 행해온 실제도로 표면에 대한 연구뿐만 아니라 미래를 내다본 제도적인 측면에 까지 관심을 가지고 있음을 알 수 있다. 지금까지 언급한 바와 같이 다공성 도로 표면에 따른 초기 소음 감소량이 5dB(A) 이상이고 도로 수명이 다함에 따라 그 감소량은 0dB(A)가 된다. 그러나, 이 소음 감소량은 저소음 도로 표면에 대한 연구 동기를 제공하기에 충분한 가치가 있다고 생각된다. 이제 국내에서도 자동차 자체의 소음의 제어나 차음벽의 설치뿐 아니라 조소음 도로 표면에 대한 연구 가 병행되어야 할 것이다.

  • PDF

A Study on the Allowable Deviation for the Measured Level of the Impact Sound Insulation Performance (바닥충격음 차음성능평가에 있어서 측정 레벨의 허용오차에 관한 연구)

  • 장길수;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.222-226
    • /
    • 1997
  • The reproducibility of measured level is a prior condition for the reliable assessment of the sound insulation performance. To review the reproducibility of impact sound level, 20 floors were selected in highrise apartment house, and then impact sound levels of two kinds of typical floors were measured with 10 times in each receiving point. The impact sound insulation class values were derived with a standard tapping machine and bang machine. Inspection of the result showed that smaller scale of the room caused to lower the reproducibility and that the higher values of standard deviation in lower frequency caused to deteriorate the reliability of assesment. Thus to enhance the reproducibility of the impact sound insulation class, greater allowable deviation of measured level is required in lower frequency than in higher one.

  • PDF