• Title/Summary/Keyword: 차열성능

Search Result 22, Processing Time 0.023 seconds

The Development and Performance on High Functional Cool Paints of Ceramic Crystal Structure (세라믹 결정구조의 고기능성 차열도료 개발 및 성능평가)

  • Do, Young-Woong;Lee, Seung-Won;Lim, Dong-Min;Ha, Jin-Wook
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05a
    • /
    • pp.344-347
    • /
    • 2012
  • 본 논문에서는 적외선 반사기능을 가지는 황색, 흑색안료를 PVDF, 첨가제와 배합하여 링밀에서 3,000rpm으로 10분간 분산한 후 세라믹 결정구조의 차열도료를 제조하였으며, 도막형성 후 $180^{\circ}C$에서 10분간 건조하여 도료에 대한 표면온도, 내후성(Q.U.V), 적외선 반사율(%)을 평가하였다. 연구결과 황색안료 9%를 첨가하여 $150{\mu}m$ 두께의 도막을 형성시켰을 때, 일반도료와의 표면온도 차이는 $10.1^{\circ}C$, 700~2,500nm 파장대의 적외선 반사율은 40% 이었으며, 흑색안료 9%를 첨가하여 $200{\mu}m$ 두께의 도막을 형성시켰을 때, 표면온도차 $18.8^{\circ}C$, 적외선 반사율 66.7%로 측정되었고, 내후성은 모두 우수하게 나타났다.

  • PDF

Experimental Study on the Heat Shielding Performance of Lightweight Foamed Concrete Using EPS beads. (EPS 비드를 사용한 경량기포콘크리트의 차열성능의 실험적 연구)

  • Hong, Snag-Hun;Song, Seung-Li;You, Nam-Gyu;Jung, Ui-In;Kim, Bong-Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.21-22
    • /
    • 2018
  • Foamed concrete is a porous concrete that is cured by mixing bubbles into cement slurry. It is lighter than ordinary concrete and is characterized by higher insulation. Lightweight foamed concerte is mainly used as a sandwich panel in Korea, and is also used as a refractory filler in fireproof safes. Studies on lightwight foamed concrete have been carried out on strength,density and thermal conductivity. However, it is confirmed that the research on the fire resistance performance is very limited. Based on this study, fire resistance of lightweight foamed concrete using expanded polystyrene beads is investigated.

  • PDF

A Study on the Change in Energy Performance of the Domestic Building by the Isolation-heat Paint (차열도료 적용을 통한 국내 건축물의 에너지 성능 변화에 관한 연구)

  • Choi, Doo-Sung;Chun, Hung-Chan;Cho, Kyun-Hyong
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.5
    • /
    • pp.33-40
    • /
    • 2011
  • In this study, it is quantitatively analyzed for thermal Characteristics of isolation-heat paint which has been supplied to a domestic market through experiments and simulations. In the case of experiment using the container box, it shows 8% decrease on cooling energy consumption in a summer season, but shows increase on heating energy consumption. As a result, the analysis has found increase of energy consumption. As a result of holding simulations with meteorological data of domestic major cities, it shows an increase of energy consumption in domestic condition, and it is hard to expect an energy saving from the isolation-heat paint unless greater air-conditioning load.

Evaluation on the Fire Resistance Performance for High-Rise Modular Walls (중·고층형 모듈러 벽체의 내화성능 평가)

  • Yang, Seung-Cho;Lee, Jae-Sung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.15-22
    • /
    • 2019
  • The use of modular buildings is increasing because of various advantages of modular buildings. But there are limits to apply modular buildings to medium-rise buildings because the building law provides only the specification criteria of the modular building with respect to the 1 hour fire resistance performance. This study was conducted to investigate 2 hours fire resistance performance of load bearing walls with steel studs in modular buildings by KS F 2257-1 and KS F 2257-4. After full scale tests, load bearing walls ensuring two hours fire resistance performance consist of at least 2 layers of fire resistance plaster boards of 19mm thickness or 3 layer of fire resistance plaster boards of thickness.

An Experimental Study on Fire Resistance Performance of Curtain-Wall System with Steel-Aluminum Hybrid Frame (스틸-알루미늄 복합 프레임을 갖는 커튼월의 내화성능에 관한 실험적 연구)

  • Lee, Jae-Sung;Yim, Hyun-Chang;Cho, Bong-Ho;Kim, Heung-Yeal
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.104-111
    • /
    • 2011
  • Aluminum has been widely used as frame materials in the curtain walls. Recently, use of steel as a curtain wall frame is being considered due to its higher strength and thermal resistance than aluminum. In this study, fire tests on the basis of EN 13830 were performed with aluminum and steel-aluminum hybrid curtain walls. From the tests, fire resistance integrity, thermal insulation, and radiation properties were evaluated for both systems and compared. According to the test results, the steel-aluminum hybrid curtain wall showed better fire-performance than the typical aluminum curtain wall for the fire resistance integrity and radiation properties. Although, the fire resistance performance for the insulation property was 6 min for both the two frames, the collapses were occurred at 36 min for the steel-aluminum hybrid curtain wall and at 13 min for the aluminum hybrid curtain wall.

A Study on the Anti-Spalling Performance of High-Strength Concrete Members by covered Engineered Cementitious Composite (ECC로 피복된 고강도콘크리트 부재의 폭렬억제성능에 관한 연구)

  • Lee, Jae-Young;Kim, Jae-Hwan;Han, Byung-Chan;Park, Sun-Gyu;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.85-94
    • /
    • 2008
  • The purpose of this study is to obtain the fundamental fire resistance performance of engineered cementitious composites (ECC) under fire temperature in order to use the fire protection material in high-strength concrete structures. The present study conducted the experiment to simulate fire temperature by employing of ECC and investigated experimentally the explosion and cracks in heated surface of these ECC. In the experimental studies, 5 HSC specimens are being exposed to fire, in order to exami ne the influence of vari ous parameters (such as depth of layer=20, 30, 40 mm; construction method=lining and repairing type) on the fire performance of HSC structures. Employed temperature curve were ISO 834 criterion (3 hr), which are severe in various criterion of fire temperature in building structures. The numerical regressive analysis and proposed equation to calculate ambient temperature distribution is carried out and verified against the experimental data. By the use of proposed equation, the HSC members subjected to fire loads were designed and discussed.

A Study on Solar Reflectance of Cool-Roof Coating Material with Heat Barrier and Waterproofing Performance According to Color Type (차열 및 방수성능을 갖는 쿨루프 도막재의 색상별 일사반사율 평가 연구)

  • Oh, Sang-Keun;Lee, Tae Yang;Park, Jin-Sang;Kim, Dong-Bum;Park, Wan-Goo;Choi, Su-Young
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.251-252
    • /
    • 2018
  • Cool roof coating materials generally use white color which has the highest reflectance, but it is a tendency to apply various colors because it can cause glare and fatigue of a nearby building user due to the urban beauty and high reflection. This study when applying color diversity material cool roof coating was carried out as a basic research for the degree of solar radiation reflectance change. Experiment result. As a result of the measurement of the reflectance of each specimen, white showed the best reflectance in the near infrared region, and black had the lowest reflectance. Also, in case of brown, it was confirmed that the reflectance of solar radiation in the near extrinsic region is lower than that of gray.

  • PDF

세라믹 나노코팅에 의한 목재의 난연성능 연구

  • An, Chan-Sol;Jo, Nam-Uk
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.137-138
    • /
    • 2013
  • 나노입자에 의한 세라믹 코팅은 제품의 방청, 내식, 내마모성을 향상시킬 뿐만 아니라 내열성을 향상시키는 데에도 효과적인 성능을 보이고 있다. 특히 지르코니아(YSZ), 산화알루미늄($Al_2O_3$), 이산화 타이타늄($TiO_2$) 등과 같이 차열 성능이 우수한 세라믹 계열을 이용한 TBC(Thermal Barrier Coating)은 이미 항공기 엔진부품이나 고성능 베어링과 같이 고온에서도 우수한 성능을 유지해야 하는 기계부품에 보편적으로 사용되어 오고 있는 방법이다. 본 연구에서는 이와 같은 차열서능이 우수한 세라믹 소재를 이용해 건축물에 많이 사용되고 있는 목재에 난연성능의 향상을 목적으로 세라믹 나노코팅을 하였을 때 목재의 연소특성이 어떻게 변화하는가를 관찰 및 분석하였다.

  • PDF

The Flame and Distributed Temperature Restraint Properties of Fire Venetian Blind Louver in Buildings (차양식 방화루버의 화염 및 온도 전파 억제 특성)

  • Chae, Young-Suk
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.1
    • /
    • pp.120-127
    • /
    • 2015
  • The purpose of this study is to improve the fire prevention performance using the fire venetian blind louver subjected to burning by fire flame. The investigation is based on testing 2 full scale specimens, which is $3m{\times}3m$ module, $850mm{\times}1,500mm$ open, and $900mm{\times}900mm{\times}175mm$ venetian blind louver. Two louver thickness (1.5 and 2.0mm) were adopted. The specimens were exposed to fire flame temperature levels of ISO834 at the lower surface of the fire venetian blind louver specimens with exposure duration of one hour in Korea Institute of Construction Technology (KICT). It was found from the test results that the values of distributed temperature, decreased for all specimens for protecting to fire flame by venetian blind louver. The results of tests were a good fire prevention performance between in initial to 6 mins. At 60 minutes around ISO 834 fire loading, the percentages of distributed temperature in 500mm and 800mm height ranged between 11 and 10% respectively, regardless of louver thickness. This study, therefore, will improve the fire venetian blind louver for fire protection and prevention performance.

The Evaluation of Fire-Resistant Performance of the Non-bearing Steel Wall Using Fire Resistant Glass (내화유리를 적용한 강재 유리벽의 내화성능 평가)

  • Lee, Jae-Sung;Yim, Hyun-Chang;Yang, Seung-Cho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.5
    • /
    • pp.72-81
    • /
    • 2018
  • Fireproof structures using concrete, built-up panels and dry walls are usually used in walls inside fire compartments. However, demand for glass walls is emerging due to increase in interest in visibility and external appearance. In this study on steel fire resistance walls using insulation glass, fire resistance tests and performance evaluations were conducted on 60 minute fire resistance walls and exterior walls which could be applied to interior fire compartments and 90 minute fire resistance walls which could be applied to curtain walls. According to the tests, the specimens satisfied the required fire resistance performance. The finite element analysis was conducted after the tests to evaluate the fire resistance performance of the glass walls. The analysis results showed that the preliminary evaluation of fire resistance performance would be feasible.