• Title/Summary/Keyword: 차단유리

Search Result 149, Processing Time 0.035 seconds

INHIBITORY EFFECT OF Er:YAG LASER ON THE GROWTH OF STREPTOCOCCUS MUTANS (Er:YAG 레이저 조사가 Streptococcus mutans의 증식억제에 미치는 효과)

  • Song, Gwang-Chul;Lee, Chang-Seop;Lee, Sang-Ho;Lee, Nan-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.15-24
    • /
    • 2003
  • The purpose of this study is to investigate the sterilization effect of Er:YAG laser against the intraoral acid producing bacterium, S. mutans, by irradiating the culture solution containing S. mutans KCTC 3065 with Er:YAG laser having a $650{\mu}m$ diameter beam through the non-contact method. We obtained the following results after examining the temperature changes of the culture solution, numbers of bacterial colonies, and acid-producing ability and attaching ability on teeth by measuring the amount of extracellular polysaccharide produced by S. mutans. The number of bacterial colony was decreased in $10{\mu}l$ culture solution irradiated with laser in overall compared to the control solution. The number decreased as the irradiation intensity and pulse repetition rate were larger and as the exposure time was increased. However, it did not change significantly in $100{\mu}l$ culture solution compared to the control solution. Although the acid-producing ability of S. mutans was inhibited for a certain duration after laser irradiation in 10r1 bacterial culture solution, it did not change in $100{\mu}m$ solution compared with the control solution. The amount of extracellular polysaccharide synthesized by S. mutans was partially decreased through laser irradiation in $10{\mu}m$ culture solution but did not change in $100{\mu}m$ culture solution. Based on these findings, we concluded that Er:YAG laser has an sterilization effect on S. mutans in which we presume that the mechanism is through the heat effect rather than the mechanical effect from development of ultrasound.

  • PDF

Physico-Chemical Properties of Rainfall Interception Culture and Open Field Culture Soils of Rubus sp. In Gochang-gun, Jeollabuk-do (고창지역 복분자 비가림하우스 토양과 노지토양의 물리·화학적 특성)

  • Chung, Byung-Yeoup;Lee, Kang-Soo;Kim, Myung-Kon;Choi, Young-Hee;Kim, Moo-Key;Cho, Jae-Young
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.5
    • /
    • pp.303-309
    • /
    • 2008
  • The physico-chemical properties of the rainfall interception culture (85 sites) and the open field culture soils (85 sites) in the area of Gochang-gun, Jeollabuk-do were surveyed. Soil textural distribution of the rainfall interception culture and the open field culture soils was 74% and 64% for silt loam, 16% and 35% for loam, and 10% and 1% for clay, respectively. The percentage of aggregate rates was higher in the open field culture soils (60.06%) than rainfall interception culture soils (55.84%). Electrical conductivity, exchangeable cations, and anions in the rainfall interception culture soils were higher than those in open field soils. Specially, accumulated amount of anion in rainfall interception culture soils was remarkably higher 2~3 times than open field culture soils. The results from the analyses of rainfall interception culture soils suggested that the most critical problem is the salts accumulation caused by over-fertilization of chemical fertilizer and compost. Therefore, application rates of chemical fertilizer and compost should be controlled in order to conservation of soil and water for sustainable agriculture.

Cellular Pathways in Agonist-induced Gallbladder Muscle Contraction in the Cat (고양이의 담낭근 수축에 있어서 세포내 기전)

  • Rhim, Byung-Yong;Kim, Chi-Dae;Kim, Dong-Heon;Biancani, Piero;Behar, Jose
    • The Korean Journal of Pharmacology
    • /
    • v.32 no.1
    • /
    • pp.67-74
    • /
    • 1996
  • Cholecystokinin octapeptide (CCK-8), acetylcholine (ACh) and KCl caused a dose dependent contraction in muscle cells enzymatically digested from cat gallbladder. Maximal contraction was obtained at concentration of $10^{-9}M$ for CCK-8, $10^{-5}M$ for ACh and 20mM for KCl. CCK-8 induced contraction was unaffected in calcium free physiological salt solution (PSS) and was completely blocked by strontium substitution for calcium (p<0.001). In contrast, KCl evoked contraction was blocked in calcium free PSS (p<0.01) but was unaffected by strontium replacement of calcium. The contraction elicited by ACh was only slightly reduced in calcium free PSS (p<0.05) and was unaltered by strontium. Muscle cells permeabilized with saponin contracted in response to inositol 1,4.5-trisphosphate $(IP_3)$ and CCK-8. The contraction was blocked by the calmodulin antagonist CGS 9343B (p<0.001), whereas heparin completely blocked the effect of $IP_3$ (p<0.001). The protein kinase C (PKC) antagonist H7 had no effect on either agonist. We conclude that CCK-8 induced gallbladder muscle contraction is mediated by $IP_3$ dependent intracellular calcium release from intracellular stores and a calmodulin dependent pathway; ACh may utilize both extracellular and intracellular calcium. KCl causes muscle contracrion through influx of extracellular calcium and a calmodulin independent machanism.

  • PDF

Study on Reduction Effect of the Non-Point Pollutants through Riparian Buffer Zones (비점오염부하 저감을 위한 수변완충지대의 효율적 조성 연구)

  • Choi, I-Song;Kim, Sung-Won;Jung, Sang-Jun;Woo, Hyo-Seop;Oh, Jong-Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1793-1797
    • /
    • 2007
  • 한강 "수변구역"에서 비점오염물질의 공공수역 유입을 억제하기 위한 다양한 방법들 중에서 보편적이고 자연친화적인 방법은 다양한 생물의 서식공간이며, 동시에 본류로 유입되는 과정에서 수질을 정화시키는 수질개선 공간인 수변완충구역, 또는 지대를 설정하여 관리하는 것이다. 그러나 이러한 수변완충지대 효과 분석 및 설정에 관한 연구는 국내에서 아직 수행되지 않았다. 본 연구의 목적은 수변구역의 자정능력을 높이는 것은 물론 그 밖의 하천 연안에서 비점오염물질의 차단과 처리능력을 증진시키고 수변 생태계의 서식처 보전 및 복원을 위해서 수변완충지대의 수질정화 기술개발과 생물다양성을 창출하는 수변완충지대 조성 기법을 개발하는데 있다. 본 연구에서는 기존 수변완충지의 추가적인 조성과 보완, 시험완충지 생태구조 및 기능 기초조사, 시험완충지 오염부하 저감효과의 실험 및 분석, 수변완충지대 설치 구상 등의 연구를 수행하였다. 수행 지역은 한강수계 지역으로 남한강 수변인 경기도 양평군 병산리에서 실시하였으며, 잔디와 갈대, 갯버들, 혼합지역, 자연그대로의 상태(대조지역)의 5 구역으로 구분하였고, 깊이별로 샘플을 채취하여 유입수와 표면유출, 하부유출을 비교해 보았다. 연구 결과, 5 가지 구역 중 잔디 구역의 SS, T-N, T-P, TOC의 제거 효율이 각각 76.7%, 85.2%, 97.6%, 83.3%로 가장 좋은 오염물질 제거 효율을 보였으며, 깊이 별 분석에서는 표면유출에서 하부유출로 갈수록 월등한 효율을 보였다. 따라서 본 연구를 통하여 비점오염원에 대한 한강수계의 수자원 보호 효과를 기대할 수 있고, 수변완충지대의 조성, 유지관리기술의 개발을 통한 수변완충지대의 계획과 설계에 직접적인 기여를 할 수 있으며, 수변구역에 설치 가능한 Riparian Buffer Zone의 중요성과 효율성을 알려 현재 하상 저니 준설 및 폭기 위주의 사업에서 생태 공학적 복원을 적극 고려한 정화사업으로 확대 추진하고자 한다.해결책을 얻어내는 상호보완적인 결과를 추구한다. 그가 디자인하는 작품은 전형적인 이미지를 내포하지 않는다. 즉 그의 작품은 기존의 가치와 이념적인 것은 배제하고, 창의적인 개념을 도출하였다.형모서리는 건물 특화 성격이 강하므로 불가피할 경우 소형 액센트 광고 위치를 미리 벽면으로 할애하는 것이 경관 및 입면계획에 유리한 것으로 분석되었다. 불확실도 해석모형 등의 새로운 기능을 추가하여 제시하였다. 모든 입출력자료는 프로젝트 단위별로 운영되어 data의 관리가 손쉽도록 하였으며 결과를 DB에 저장하여 다른 모형에서도 적용할 수 있도록 하였다. 그리고 HyGIS-HMS 및 HyGIS-RAS 모형에서 강우-유출-하도 수리해석-범람해석 등이 일괄되게 하나의 시스템 내에서 구현될 수 있도록 하였다. 따라서 HyGIS와 통합된 수리, 수문모형은 국내 하천 및 유역에 적합한 시스템으로서 향후 HydroInformatics 구현을 염두에 둔 특화된 국내 수자원 분야 소프트웨어의 개발에 기본 토대를 제공할 것으로 판단된다.았다. 또한 저자들의 임상병리학적 연구결과가 다른 문헌에서 보고된 소아 신증후군의 연구결과와 큰 차이를 보이지 않음을 알 수 있었다. 자극에 차이가 있지 않나 추측되며 이에 관한 추후 연구가 요망된다. 총대장통과시간의 단축은 결장 분절 모두에서 줄어들어 나타났으나 좌측결장 통과시간의 감소 및 이로 인한 이 부위의 통과시간 비율의 저하가 가장 주요하였다. 이러한 결과는 차가운 생수 섭취가 주로 결장 근위부를 자극하는 효과를 발휘하는 것이 아닌가 해석된다. 이와 같은 연구결과를 통해 생다시마를 주원료로 개발된 생다시마차와 생다시마 음료가 만성 기능성 변비 증세를 개선하는 효능이 잠재적으로 있음을 확인하였다. 그러나 생약제재의 변비약 수준으로 변비 개선 효능을 증대하기 위해서는 재료 배합비의 개선이나 대장 운동기능을 향상시키는 유효성분의 보강 등이 필요하다는 점도 알 수 있었다.더불어 산화물질 해독에 관여하는

  • PDF

Turion as Dormant Structure in Spirodela polyrhiza (개구리밥 휴면구조 잠아의 구조적 특성)

  • Kwak, Mi-Young;Kim, In-Sun
    • Applied Microscopy
    • /
    • v.38 no.4
    • /
    • pp.307-314
    • /
    • 2008
  • Hydrophytes such as Spirodela polyrhiza form dormant turions to withstand cold winters. The turion is an anatomically distinct structure from which a vegetative frond arises later during germination. The turions sink to the bottom of the pond when temperatures drop and remain there throughout the winter. In the spring, they float to the surface and germinate into a new frond from the turion primordium. Unlike fronds, turions are known to possess small aerenchyma, starch grains, and relatively dense cytoplasm. These features allow the turions to survive the cold winter season at the bottom of the pond. Spirodela polyrhiza has been investigated previously to a great extent, especially in its physiological, biochemical and ecological attributes. However, a little is known about the structural features of the frond and turion during turion development. Thus, the aim of the present study was to reveal the structural characteristics of the frond and turion with regard to tissue differentiation, aerenchyma development, starch distribution, and ultrastructure, with the use of electron microscopy. A moderate degree of mesophyll tissue differentiation was found in the frond, whereas the turion did not exhibit such differentiation. Within the frond tissue, approximately $37{\sim}45%$ of the cellular volume was occupied by a large aerenchyma, but only $9{\sim}15%$ was taken up by the aerenchyma in the turion. The turion cells, especially those of the turion primordium, were derived from frond cells, and contained cytoplasm. Their cytoplasm was densely packed with plastids, mitochondria, endoplasmic reticulum, Golgi bodies, and microtubules. Plasmodesmata were also well developed within these cells. The most striking feature observed was the distribution of starch grains within the plastids of turion cells. Before the turion sank to the bottom of the pond, a considerable amount of starch accumulated in the plastid stroma. The starch grains dissolved when temperatures rose in the spring, and this promptly provided the nutrients which the primordium needed for turion germination. The turion therefore, was an appropriate dormant structure for free-floating, reduced hydrophytes like Spirodela polyhriza due to its small aerenchyma and large starch grains that aided in the purpose of sinking below the surface of the water to survive cold winters. The new fronds that arose from such turions grew rapidly in the spring, beginning the new life cycle.

The Clinical Effects of Leukocyte-Depleting Filter on Cardiopulmonary Bypass (체외순환 시 백혈구 제거필터 사용의 임상효과)

  • 박경택;최석철;최국렬;정석목;최강주
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.454-464
    • /
    • 2001
  • Background: It has been recognized that systemic inflammatory reaction and oxygen free radical formed by activated leukocyte in the procedure of cardiopulmonary bypass(CPB) frequently produce postoperative cardiac and pulmonary dysfunction. The purpose of this study was to evaluate the efficacy of leukocyte-depleting filters in the cardiopulmonary bypass circuit for patients undergoing open heart surgery(OHS). Material and method: The study involved 15 patients who underwent OHS with a Leukoguard-6 leukocyte filter placed in the arterial limbs of the bypass circuit(filter group, n=15) and 15 patients who did not have the filter(control group, n=15). We analyzed the differences between the groups in intraoperative changes of peripheral blood leukocyte and platelet counts, pre- and postbypass changes of malondialdehyde(MDA), troponin-T(TnT), 5'-nucleotidase(5'-NT) in coronary sinus blood, spontaneous recovery rate of heart beat after CPB, pre-and postoperative cardiac index(Cl) and pulmonary vascular resistance(PVR), and the amounts of postoperative bleeding and sternal wound complication. Result: During CPB, total leukocyte count of the filter group(9,567$\pm$ 842/㎣) was significantly less than that of the control group(13,573+1,167/㎣) (p<0.01), but there was no significant difference in platelet count between the groups. Postoperative levels of MDA(3.78+0.32 $\mu$mol/L vs 5.86+0.65 $\mu$mo1/L, p<0.01), TnT(0.40$\pm$0.04 ng/mL vs 0.59$\pm$0.08 ng/mL, p<0.05) and 5'-NT(3.88$\pm$0.61 U/L vs 5.80$\pm$0.90 U/L, p<0.05) were all significantly lower in the filter group than the control group. Postoperative Cl was higher in the filter group than the control group(3.26$\pm$0.18 L/$m^2$min vs 2.75$\pm$0.17 L/$m^2$/min, p=0.05). PVR of the filter group was lower than that of the control group(65.87$\pm$7.59 dyne/sec/cm$^{5}$ vs 110.80+12.22 dyne/sec/cm$^{5}$ , p<0.01). Spontaneous recovery rate of heart beat in the filter group was higher than that in the control group(12 patients vs 8 patients, p<0.05). Postoperative wound infection occurred in one case in the filter group and 4 case in the control group(p<0.05). Postoperative 24 hour blood loss of the filter group was more than that of the control group (614$\pm$107 mL vs 380+71 mL, p=0.05).

  • PDF

Study of Quality Control of Traditional Wine Using IT Sensing Technology (IT 센싱 기술을 이용한 전통주 발효의 품질관리 연구)

  • Song, Hyeji;Choi, Jihee;Park, Chan-Won;Shin, Dong-Beom;Kang, Sung-Soo;Oh, Sung Hoon;Hwang, Kwontack
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.6
    • /
    • pp.904-911
    • /
    • 2015
  • The objective of this study was to investigate the quality characteristics of traditional wine using an radio-frequency identification (RFID) system annexed to a fermenter. In this study, we proposed an RFID-based data transmission scheme for monitoring fermentation of traditional alcoholic beverages. The pH, total acidity, total sugar, soluble sugar, free sugar, alcohol content, and organic acids of were investigated and subjected to fermentation of traditional alcoholic beverages three times. The pH ranged from 7.98, 7.95, and 7.68 at day 0, decreased drastically to 3.31~2.96 at day 2, and then slowly increased to the end point, finally reaching 3.34 at day 20. Acidity tended to increase quickly with time, especially for all samples after day 2. The fermentation environment induced a sudden increase acidity in reactants and indicated a low pH. The total sugars during fermentation quickly decreased to the range of 20.3, 22.43, and 19.2% at day 2, and the slope of reduction steadily decreased to 5.1, 6.1, and 4.8% at day 10. On the other hand, the alcohol content showed the reverse trend as total sugars. The alcohol content also showed the same pattern as total acids, showing the highest alcohol content of 17.3% (v/v) on day 20. In this study on traditional wine fermentation using an RFID system, we showed that pH, soluble sugar, and alcohol content can be adopted as key indicators for quality control and standardization of traditional wine manufacturing.

Isotopic Determination of Food Sources of Benthic Invertebrates in Two Different Macroalgal Habitats in the Korean Coasts (동위원소 분석에 의한 동해와 남해 연안의 상이한 해조류 군락에 서식하는 저서무척추동물 먹이원 평가)

  • Kang, Chang-Keun;Choy, Eun-Jung;Song, Haeng-Seop;Park, Hyun-Je;Soe, In-Soo;Jo, Q-Tae;Lee, Kun-Seop
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.4
    • /
    • pp.380-389
    • /
    • 2007
  • Stable carbon and nitrogen isotopes were analyzed in suspended particulate organic matter, macroalgae and macrobenthic invertebrates in order to determine the importance of primary organic matter sources in supporting food webs of rocky subtidal and intertidal macroalgal beds in the Korean coasts. Investigations were conducted at the inter tidal sites within Gwangyang bay, a semi-enclosed and eutrophicated bay, and the subtidal sites of the east coast, a relatively oligotrophic and open environment, in May and June 2005. Water-column suspension feeders showed more negative $\delta^{13}C$ values than those of the other feeding guilds, indicating trophic linkage with phytoplankton and thereby association with pelagic food chains. In contrast, animals of the other feeding guilds, including interface suspension feeders, herbivores, deposit feeders, omnivores and predators, displayed relatively less negative $\delta^{13}C$ values than those of the water-column suspension feeders and similar with that of macroalgae, indicating exclusive use of macroalgae-derived organic matter and association with benthic food chains. Most the macrobenthic species were considered to form strong trophic links with benthic food chains. In addition, the distribution of higher $\delta^{15}N$ values in macrobenthic consumers and macroalgae at the intertidal sites of Gwangyang Bay than those at the subtidal sites of the east coast suggests that anthropogenic nutrients may enhance the macroalgal production at the intertidal sites and in turn be incorporated into the particular littoral food web in Gwangyag Bay. These results confirm the dominant role of macroalgae in supporting rocky subtidal and intertidal food webs in the Korean coasts.

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF