• Title/Summary/Keyword: 질의재구성

Search Result 94, Processing Time 0.021 seconds

A Study on the Contextual Layout Process of Exhibit Space With a Focus on the expo Comm Wireless Korea '99-KT Pavilion (전시공간 맥락화 구성 프로세스 사례연구 expo Comm Wireless Korea '99 -한국통신관을 중심으로)

  • 김준호
    • Archives of design research
    • /
    • v.13 no.1
    • /
    • pp.121-130
    • /
    • 2000
  • This study can be expressed by gathered and formed into the exhibition space's structure practical progress/ application. For the one model of fascinating exhibition's space thru inter-space's pertinent adjustment, production between spactator and exhibition constituent on an exhibition story-line, I adjusted the focus to follow mentioned methods systematically for the example; An exhibition space is completed to be very impressive and attractive space by proper adjustment and production of M-M/C interface in exhibition storyline. Quantity space is transfered into quality space through the transmission of an exhibition which can be define as the point of an exhibition structure. And also could de transferd into a bodily sensation space that inherent full of interactive constituent. Changeable exhibition constituents (exhibition item and text) that sporadically expatiated (not trimed, the original form) in the process of an exhibition structure draw much higer quality of the optimal solution in optimize process which is given when aggregate again to contextual flow of synthetic exhibition scenario. Reconstruction of individual exhibition constituents to the new story, that is, transference of exhibition text to exhibition context is inspirit to an exhibition by maximize the exhibition effect in connection can be systematized through carrying out an outcentripetalpart. However, since pattern of an exhibition structure that consequtively meet variety spacetime of an exhibittion environmental can't be exist, this study presents centralizing the exhibition plan of Korea communication pavilion of the annual Expo Comm Wireress Korea, sustained process from design proposal, research and analysis to synthesis, development, transmission and management to an example of an applying crystallization.

  • PDF

The effects of physical factors in SPECT (물리적 요소가 SPECT 영상에 미치는 영향)

  • 손혜경;김희중;나상균;이희경
    • Progress in Medical Physics
    • /
    • v.7 no.1
    • /
    • pp.65-77
    • /
    • 1996
  • Using the 2-D and 3-D Hoffman brain phantom, 3-D Jaszczak phantom and Single Photon Emission Computed Tomography, the effects of data acquisition parameter, attenuation, noise, scatter and reconstruction algorithm on image quantitation as well as image quality were studied. For the data acquisition parameters, the images were acquired by changing the increment angle of rotation and the radius. The less increment angle of rotation resulted in superior image quality. Smaller radius from the center of rotation gave better image quality, since the resolution degraded as increasing the distance from detector to object increased. Using the flood data in Jaszczak phantom, the optimal attenuation coefficients were derived as 0.12cm$\^$-1/ for all collimators. Consequently, the all images were corrected for attenuation using the derived attenuation coefficients. It showed concave line profile without attenuation correction and flat line profile with attenuation correction in flood data obtained with jaszczak phantom. And the attenuation correction improved both image qulity and image quantitation. To study the effects of noise, the images were acquired for 1min, 2min, 5min, 10min, and 20min. The 20min image showed much better noise characteristics than 1min image indicating that increasing the counting time reduces the noise characteristics which follow the Poisson distribution. The images were also acquired using dual-energy windows, one for main photopeak and another one for scatter peak. The images were then compared with and without scatter correction. Scatter correction improved image quality so that the cold sphere and bar pattern in Jaszczak phantom were clearly visualized. Scatter correction was also applied to 3-D Hoffman brain phantom and resulted in better image quality. In conclusion, the SPECT images were significantly affected by the factors of data acquisition parameter, attenuation, noise, scatter, and reconstruction algorithm and these factors must be optimized or corrected to obtain the useful SPECT data in clinical applications.

  • PDF

Earnings Quality of Firms Selected as the Global Champ Project (글로벌 전문사업 선정기업의 이익의 질)

  • Gong, Kyung-Tae
    • Management & Information Systems Review
    • /
    • v.37 no.4
    • /
    • pp.1-20
    • /
    • 2018
  • This study aimed to examine earnings quality of firms selected as Global Champs project which has been promoted by the government since 2013 to support small and medium sized enterprises, for the screening year(t-1) and selected year(t). Earing quality is measured as the value of discretionary accruals estimated by Dechow et al.(1995) adjusted Jones model and Kothari et al.(2005) model, respectively. I analyze the differences of earning quality between the Global Champ firms and the paired firms selected through criteria of the similar total assets and the same industry in the screening year and the selected year. This study is motivated by the needs of measurement of the performance of the Project from the accounting transparent point of view. As the results of this study, major findings are summarized as follows. Firstly the earnings quality of the selected firms was lower than that of the paired firms. This can be explained as a result of motivation of earnings management by companies eager to meet the requirements to be selected for the Project. Secondly, in the selected year, the earnings quality was proved to improve, comparing to the screening year. This can be explained by the efforts of companies to reinforce management innovation and transparent management, which in turn led to positive effects on the earnings quality. These findings were found to be consistent in the additional analyses, where the earning quality of the reconstructed sample with only selected companies was compared for the screening year and the selected year, based on the year before the screening year(t-2).

Differentiation of Parkinson's Disease and Essential Tremor on I-123 IPT(I-123-N-(3-iodopropen-2-yl)-$2{\beta}$-carbomethoxy- $3{\beta}$-(4-cholorophenyl) tropane) Brain SPECT (파킨슨병과 본태성 진전의 감별진단에서 I-123 IPT(I-123-N-(3-iodopropen-2-yl)-$2{\beta}$-carbomethoxy-$3{\beta}$-(4-cholorophenyl) tropane) 뇌 단일광전자방출 전산화단층촬영의 역할)

  • Pai, Moon-Sun;Choi, Tae-Hyun;Ahn, Sung-Min;Choi, Jai-Yong;Ryu, Won-Gee;Lee, Jae-Hoon;Ryu, Young-Hoon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.100-106
    • /
    • 2009
  • Purpose: The study was to assess I-123-N-(3-iodopropen-2-yl)-2[beta]-carbomethoxy-3[beta]-(4-cholorophenyl) tropane(IPT) SPECT in differential diagnosis among early stage of Parkinson's disease(PD) and essential tremor(ET) and normal control(NL) groups quantitatively. Materials and Methods: I-123 IPT brain SPECT of 50 NL, 20 early PD, 30 advanced PD, and 20 ET were performed at 20 minutes and 2 hours. Specific/nonspecific binding of striatum was calculated by using right and left striatal specific to occipital non-specific uptake ratio(striatum-OCC/OCC). Results: Mean value of specific/nonspecific binding ratio was significantly different between advanced PD group and NL group. However, significant overlap of striatal specific/nonspecific binding ratio was observed between PD group and ET group. Bilateral striatal specific/nonspecific binding ratios were decreased in advanced PD. Lateralized differences in the striatal uptake of I-123 IPT correlated with asymmetry in clinical findings in PD group. Conclusion: I-123 IPT SPECT may be a useful method for the diagnosis of PD and objective evaluation of progress of clinical stages. Care should be made in the differential diagnosis of early stage of PD and other motor disturbances mimicking PD such as ET in view of significant overlap in striatal I-123 specific/nonspecific binding ratio.