• Title/Summary/Keyword: 질량 측정방식

Search Result 36, Processing Time 0.029 seconds

고대철기의 년대측정 방법개발 - 탄뎀(Tandem)형 가속기 이용해서 측정

  • 한국원자력산업회의
    • Nuclear industry
    • /
    • v.14 no.10 s.140
    • /
    • pp.72-76
    • /
    • 1994
  • 이제까지 고대철기의 년대측정은 함께 출토된 토기를 빌어서 이루어져 왔다. 일본에서는 철을 만들 때 열선으로 사용한 목탄에서 흡입된 탄소를 탄뎀형가속기를 이용해 방사선 동위체비 측정방식으로 가속기 질량분석에 위해 철기의 년대를 알아내는 법을 개발했다.

  • PDF

Heart-Model-Based Automated Method for Left Ventricular Measurements in Cardiac MR: Comparison with Manual and Semi-automated Methods (자동화 방식 모델 기반 좌심방 파라미터 측정법: 수동 및 반자동 방식과의 비교)

  • Chae, Seung Hoon;Lee, Whal;Park, Eun-Ah;Chung, Jin Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.3
    • /
    • pp.200-206
    • /
    • 2013
  • Purpose : To assess the effect of applying an automated heart model based measurements of left ventricle (LV) and compare with manual and semi-automated measurements at Cardiovascular MR Imaging. Materials and Methods: Sixty-two patients who underwent cardiac 1.5T MR imaging were included. Steady state free precession cine images of 20 phases per cardiac cycle were obtained in short axis views and both 2-chamber and 4-chamber views. Epicardial and endocardial contours were drawn in manual, automated, and semi-automated ways. Based on these acquired contour sets, the end-diastolic (ED) and end-systolic (ES) volumes, ejection fraction (EF), systolic volume (SV) and LV mass were calculated and compared. Results: In EDV and ESV, the differences among three measurement methods were not statistically significant (P = .399 and .145, respectively). However, in EF, SV, and LV mass, the differences were statistically significant (P=.001, <001, <001, respectively) and the measured value from automated method tend to be consistently higher than the values from other two methods. Conclusion: An automatic heart model-based method grossly overestimate EF, SV and LV mass compared with manual or semi-automated methods. Even though the method saves a considerable amount of efforts, further manual adjustment should be considered in critical clinical cases.

A Study of Design of $H_2O_2$/Kerosene Ignition Injector and Spray Characteristics (과산화수소/케로신 점화용 분사기 설계 및 분무특성에 관한 연구)

  • Kim, Bo-Yeon;Hwang, Oh-Sik;Lee, Yang-Suk;Ko, Young-Seong;Kim, Yoo;Kim, Sun-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.37-40
    • /
    • 2009
  • This study was performed to design of $H_2O_2$/Kerosene catalyst ignition injector and cold flow test to measure the mass flow rate and spray angle. Mass flow rate and spray angle were measured by designed injector through cold flow test. Result of test kerosene mass flow rate was measured 12.88 g/s and 40 deg of spray angle at pressure drop 3 bar as same as design point. And hydrogen peroxide was measured 94.39 g/s at pressure drop 1 bar smaller than design point.

  • PDF

Capability of force standards at KRISS (한국의 힘표준 능력)

  • 강대임;박연규;김종호;김민석
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.9
    • /
    • pp.7-11
    • /
    • 2004
  • 일상생활과 산업현장에서 측정되는 힘의 범위를 정리해 보면 Fig. 1 과 같다. 힘의 SI 단위인 1뉴턴(N : 단위 질량 1 kg에 대해 1$m/s^2$ 의 가속도를 생기게 하는 힘의 크기임 정성적으로는 사과 반쪽을 손에 들고 있을 때 느끼는 중력의 크기가 약 1 N임)을 기준으로 크게는 수십 MN($10^{6}$ N) 크기의 우주선에서 발생하는 추진력에서부터 작게는 수 PN($10^{-12}$ N) 크기의 원자들 사이의 결합력까지 그 범위가 매우 광범위하다.

Development of Ambient Ionization Mass Spectrometry Imaging for Live Cells and Tissues

  • Kim, Jae-Yeong;Seo, Eun-Seok;Lee, Seon-Yeong;Jeong, Gang-Won;Mun, Dae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.229.1-229.1
    • /
    • 2015
  • 생체 시료인 세포나 조직을 분석을 위해 임의로 파괴하거나 훼손하지 않은 본래의 상태에서 세포에 존재하는 다양한 생체분자 물질의 질량과 조성을 분석하고 영상화할 수 있는 대기압 표면 질량분석 이미징 기술을 개발했다. 생체 시료의 표면을 질량 분석을 하기 위해서는 대기압 분위기에서 시료에 열적 손상이 없는 조건으로 시편의 이온화 및 탈착 과정이 이루어지게 하기 위해 저온 대기압 탈착/이온화원으로 저온대기압 플라즈마 젯과 펨토초 적외선 레이저를 결합하여 대기압 이온화원을 제작하였다. 기존에 잘 알려진 저온 대기압 플라즈마 젯 소자는 유리관에 방전기체를 흘려주고 전극에 고전압을 인가하는 방식으로 제작했으며, 또 다른 대기압 이온화원으로서 근적외선 대역의 고출력 펨토초 레이저 빔을 현미경용 대물렌즈로 집속하여 생체시료에 조사시켰다. 수백 나노미터에서 수 마이크로미터 수준으로 빔을 집속할 수 있는 펨토초 레이저는 금나노로드의 도움으로 생체 시료를 매우 작은 수준으로 탈착하는 데 주로 사용하며, 수십 마이크로미터에서 수 밀리미터 정도의 크기를 가지는 저온 대기압 플라즈마 젯은 탈착된 물질을 이온화시키는데 사용하여, 이 두 가지 이온화원을 결합하여 이온화원으로 사용한다. 시료에서 발생한 이온을 질량분석기 입구까지 잘 끌고 갈 수 있도록 이온 전달관을 설계하고 보조펌프를 장착 사용한다. 이렇게 자체 개발한 대기압 이온화원을 상용 질량분석기기와 결합하여 대기압 분위기에서 시료의 표면을 질량분석할 수 있는 시스템과 측정 기술을 개발했다. 현미경 스테이지에 정밀 2-D 자동 스캐닝 스테이지를 장착하여 질량분석 정보에 공간 정보를 더할 수 있는 질량분석 이미징 기술 방법을 개발하여 생체 시편의 질량분석 이미징을 얻었다. 수분을 포함하는 생채시료로부터 단백질, 지질, 대사물질을 직접 분리하여 분석하는 이 새로운 질량분석법은 기존의 분석법에 비해 훨씬 더 많은 생체분자 정보를 얻을 수 있으며 공간정보를 더해 영상화할 수 있는 큰 장점이 있다. 대기압 표면 질량분석 기술은 생체시료를 파괴해서 용액화할 필요도 없으며, 진공 챔버에 넣기 위해 필요한 복잡한 전처리 과정 단계를 간략화 할 수 있으며 최종적으로는 살아있는 세포나 생체 조직도 정량 분석이 가능하여 생명과학 및 의료진단 분야에서 응용할 수 있는 분야는 무궁무진할 것이다.

  • PDF

Estimation of heat release rate of liquid fuels by Oxygen consumption technique (산소 소모법에 의한 액체 연료의 열발생율 평가)

  • 한용식;김명배;최준석
    • Fire Science and Engineering
    • /
    • v.12 no.3
    • /
    • pp.31-37
    • /
    • 1998
  • The heat release rate of liquid fuels is estimated by oxygen consumption technique. This method is based on the generalization that the heat release rate of combustion per unit of oxygen consumed are approximately the same for most fuels commonly encountered in fires. The oxygen concentration is measured by analyzer of paramagnetic type. The concentrations of CO2 and CO gas are measured by analyzed of Infra-Rad type. Time delays of analyzers are ignored. Results acqired from measuring techniques of exhaust gas concentrations are compared with each other.

  • PDF

Quantitative Alpha Fetoprotein Detection with a Piezoelectric Microcantilever Mass Sensor (압전 마이크로캔틸레버 질량센서를 이용한 정량적 알파태아단백 검출)

  • Lee, Sangk-Yu;Cho, Jong-Yun;Lee, Yeol-Ho;Jeon, Sang-Min;Cha, Hyung-Joon;Moon, Wonk-Yu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.487-493
    • /
    • 2011
  • Alpha fetoprotein(AFP), which is serological marker for hepatocellular carcinoma, was quantitatively measured by its normal concentration, 10 ng/ml, with a label-free piezoelectric microcantilever mass sensor. The principle of detection is based on changes in the resonant frequency of the piezoelectric microcantilever before and after target molecules are attached to it, and its resonant frequency is measured electrically using a conductance spectrum. The resonant frequency of the developed sensor is approximately 1.34 MHz and the mass sensitivity is approximately 175 Hz/pg. The sensor has high reliability as mass sensor by reducing the effect of surface stress on resonant frequency due to attached proteins. 'Dip and dry' technique was used to react the sensor with reagents for immobilizing AFP antibody on the sensor and detecting AFP antigen. The measured mass of the detected AFP antigen was 6.02 pg at the concentration of 10 ng/ml, and 10.67 pg at 50 ng/ml when the immunoreaction time was 10 min.

Comparision in Emission Inspection System of a Gasoline Vehicle in Service (운행 휘발유 자동차의 배출가스검사 시스템 비교)

  • Oh, Sangyeob;Park, Wondeok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • In the most of a nation, the safety and emission gas inspection system of a vehicle in service have been conducted with the most compatible inspection system according to its real environmental situation. Especially, the state of vehicle emission gas is measured by advanced emission gas inspection equipment. It has the problem that the decrease effect of an environmental pollution matter is not calculated by weight percent measurement type equipment. Therefore, in this study, the correlations for the results of emission gas measurement are analyzed by comparing a weight percent measurement type (IDLE+ASM2525 mode) and an advanced mass measurement type (IM240 mode). As the result, the selectivity of an emission gas by IM240 mode is higher than that by IDLE+ASM2525 mode. In the future, therefore, the introduction of IM240 mode and a mass measurement type equipment are necessary. Also, we need to prepare a vehicle emission gas inspection system for introducing IM240 mode.

The Analysis of the 0.5 mm and 1 mm Rain-Gauges typed of Tipping Bucket by Standard calibration System (표준교정시스템에 의한 0.5 mm, 1 mm급 전도형 우량계의 특성 분석)

  • Shin, Gang_Wook;Hong, Sung-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1801-1802
    • /
    • 2006
  • 강우량계는 기상관측 장비중 비가 온 양을 측정하기 위한 장비로 전도형, 저수형, 중량형, 로드셀형 등 다양한 종류의 강우량계가 있다. 전도형 우량계의 경우 단순한 측정방법 및 유지보수의 용이성, 접점방식에 의한 신호의 디지털화 적용성이 우수하기 때문에 가장 널리 사용되고 있다. 전도형 우량계는 분해능에 따라 0.1mm, 0.2mm, 0.5mm, 그리고 1.0mm급으로 분류며, 저수지 관리를 위해 사용되고 있는 우량계는 1.0mm 급을 주로 사용하고 있으며, 보다 정밀하게 측정하기 위하여 0.5mm 급 우량계도 사용하고 있다. 이러한 전도형 우량계의 정확도를 검정하기 위한 방법으로 수자원연구원에 질량측정에 의한 검 교정을 할 수 있는 표준교정시스템이 구축되어 있으며, 이 시스템을 이용하여 0.5mm 및 1.0mm 전도형 우량계에 대하여 강우강도를 20, 40, 60, 80, 100, 120, 140, 160, 180, 200 mm/h로 가변하면서 강우강도의 변화에 따른 분해능이 다른 우량계의 오차특성을 비교 분석하고자 한다.

  • PDF

A Study on Speed Error of Disk Type SPMSM with Eccentric Load (편심 부하를 가지는 Disk Type SPMSM에서 속도오차에 관한 연구)

  • Lee, K.W.;Kim, Y.S.;Lee, H.J.;Ryoo, S.R.;Kwon, Y.A.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.109-111
    • /
    • 2002
  • 디스크 형의 회전자를 가지고 있는 영구자석 표면 부착형 동기 전동기에서 회전자가 중력 방향에 직각으로 서있고, 디스크 상에 부하가 존재하는 경우 디스크의 불균일한 질량 분포에 의해 편심이 발생한다. 편심 부하는 합성 무게 중심이 반중력 방향으로 향하면 전동기의 속도는 감소하고, 중력 방향이면 속도가 증가하는 정현적인 부하 토크로 작용하여 정현적 인 속도 오차를 발생시킨다. 이 속도 오차를 감소시키기 위해 q-축 전류와 측정된 속도를 입력으로 가지는 부하 토크 관측기를 설계하여 생성된 보상전류를 피드 포워드 방식으로 q-축 지령 전류에 보상하는 방식을 사용한다. 본 연구에서는 부하 토크 관측기를 사용하는 방식에서 발생하는 속도오차에 관하여 분석하였다.

  • PDF