• Title/Summary/Keyword: 진직도 측정

Search Result 23, Processing Time 0.022 seconds

Development of Straightness Measurement System for Improving Manufacturing Process Precision (ODN제조 공정 정밀도 향상을 위한 진직도 측정시스템 개발)

  • Kim, Eung Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.1
    • /
    • pp.17-21
    • /
    • 2019
  • In this paper, a high precision straightness measurement system has been developed at low cost using a visible laser and CMOS image sensor. CMOS image sensor detected optical image and the variation of straightness was calculated by image processing. We have observed that the error of the developed straightness measurement system was 0.9% when a distance of 3m between laser and image sensor. And it can be applied to 3D printer and any other areas.

2축 리니어모터 시스템에서의 진직도 측정과 분석

  • 김준현;오준모;최우천
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.195-195
    • /
    • 2004
  • 리니어 모터는 큰 이송속도와 정밀한 위치제어가 가능하여 고정밀도가 요구되는 분야에서 널리 사용되고 있으며, 이에 대한 연구도 활발히 진행되고 있다. 그 중 리니어 모터의 정밀도를 저해하는 요인 및 측정 방법에 대해서도 연구가 점차로 많이 진행되고 있으며, 현재 시스템이 가지고 있는 기하학적 오차에 관한 연구와 열변형에 관한 연구가 보고되었다. 특히 기하학적 오차는 가공물의 정밀도를 결정하는 중요한 지표이며, 가공된 물체를 결정하는 기본요소이기 때문에 가장 많이 연구되었으며, 이에 대한 다양한 해석 방법과 보상에 관한 연구가 이루어졌다.(중략)

  • PDF

Optical Straightness Measuring System Using a Ball-lens (볼렌즈를 이용한 광학식 진직도 측정시스템)

  • Lee, Minho;Cho, Nahm-Gyoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.12
    • /
    • pp.1133-1139
    • /
    • 2014
  • This paper proposes a simple method to improve a sensitivity of a straightness measurement system for a linear stage, which is applied to a system based on a geometric optic method. An optical system for this method is composed of a corner-cube retro-reflector, a ball-lens and a twodimensional position sensitive detector (2D PSD). The effectiveness of the proposed method was examined theoretically, and verified experimentally using a prototype measurement system. The results show that the measuring sensitivity was dependent on the size of the ball-lens and the setup position of PSD from the ball-lens, and that the proposed method is efficient method to improve the measuring sensitivity.

Straightness Measurement Error Compensation of the Laser Interferometer (레이저 간섭계의 진직도 측정오차 보상)

  • 김경호;김태호;송창규;이후상;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.114-118
    • /
    • 2001
  • HP Laser Interferometer Measurement System[HP5529A] is one of the most powerful equipment for measurement of the motion accuracy. The straightness measurement system of the HP5529A is composed of wollastone prism and reflector. In this system, straightness error is measured by relative lateral motion between prism and reflector. But rotating motion of prism or reflector as moving optic causes not real straightness error but additive straightness error. Especially unwanted straightness error as this becomes very large when reflector is used as moving optic and an interval between reflector and prism is distant. In this paper, the compensation method is proposed for removing additive error and experiment is carried out for theoretical verification.

  • PDF

A Study on the Measurement for Straightness and Orhogonality Using CT Method (CT 법을 이용한 진직도 및 직각도 측정에 관한 연구)

  • 이승수;김민주;박정보;전언찬
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.1
    • /
    • pp.83-90
    • /
    • 2002
  • As high-precision parts are needed with manufacturing techniques improved. the demand of high-precision machine tools has been increasing They are made to developed the precision measuring skill to maintenance the accuracy of themselves as a matter or course We one paper measured straightness and orthogonality of the square to verify that it is possible for CT(circular test) method by 2-dimensional probe and the square to measure orthogonality Furthemore we compared the result of the study with the computer simulation's to prove its possibility and made an improvement of measuring method.

Development of straightness measurement system for flat workpiece (평면 공작물의 진직도 측정 시스템 개발)

  • 김현수;조명동;장문주;홍성욱;박천홍
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.203-206
    • /
    • 2001
  • This paper presents a straightness measurement system for flat and long workpieces. The measurement system consists of a laser optical unit, a CCD camera and processing system, and a carrier system with a stylus. The carrier system accompanies the stylus, which displaces a retroreflector along the surface profile. The optical unit is used to optically amplify the displacement of retroreflector. The CCD camera and processing system finally identifies the vertical displacement of the stylus unit. The developed system is applied to two surfaces: ground surface and LM guide surface. The experimental results show that the developed system can measure the straightness of flat surfaces within sub-micron error.

  • PDF

Development of a Submicron Order Straightness Measuring Device (서브미크론 진직도 측정장치 개발)

  • 박천홍;정재훈;김수태;이후상
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.5
    • /
    • pp.124-130
    • /
    • 2000
  • For measuring out the submicron order straightness, a precision measuring device is developed in this paper. The device is constructed with a hydrostatic feed table and a capacitive type sensor which is mounted to the feed table. Straightness is acquired as substracting the motion error of feed table from the measured profile with probe. Motion error of feed table is simultaneously compensated upto 0.120${\mu}{\textrm}{m}$ of linear motion error and 0.20arcsec of angular motion error using the active controlled capillary. Reversal method and strai호t-edge is used fur estimating the measuring accuracy and from the experimental result, it is verified that the device has the measuring accuracy 0.030m. Also, through the practical application on the measurement of ground surface, it is confirmed that the device is very effective to measure the submicron order straightness.

  • PDF

Development of Straightness Measurement System thor Flat Workpieces (평면 공작물 진직도 측정 시스템 개발에 관한 연구)

  • Kim, Hyeon-Su;Jang, Mun-Ju;Hong, Seong-Uk;Park, Cheon-Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.3
    • /
    • pp.107-113
    • /
    • 2002
  • This paper presents a straightness measurement system for flat and long workpieces. The measurement system consists of a laser, a CCD camera and processing system, a carrier system with a stylus, and some optical units. The carrier system accompanies the stylus, which displaces and retroreflector along the surface profile. The optical unit is used to optically amplify displacement of the stylus unit. The developed system is applied to a ground surface and a LM guide unit. The experimental results show that the developed system can measure the straightness of flat surface and moving systems.