• Title/Summary/Keyword: 진료 형태

Search Result 187, Processing Time 0.03 seconds

The attrition pattern in Angle Class III malocclusion with facial astmmetry (안면비대칭을 동반한 Angle III급 부정교합자의 교모양상)

  • Son, Woo-Sung;Jeon, Eun-Ye;Kim, Sung-Jo
    • The korean journal of orthodontics
    • /
    • v.27 no.4 s.63
    • /
    • pp.549-557
    • /
    • 1997
  • This study was designed to investigate the attrition pattern in Angle Class III malocclusion with facial asymmetry. The sample consisted of three groups, the 20 subjects of normal occlusion group(Group I), the 12 subjects of class III malocclusion without facial asymmetry group(Group II) and 17 subjects of Class III malocclusion with facial asymmetry group(Group III). Attrition areas from canine to second molar on both sides in upper and lower arch, totally twenty, was marked by pencil and mesured by computer system(INTERGRAPH CO. USA) 2 times and the average value was used for date processing. Attrition areas from canine to second molar on both sides in upper and lower arch, totally twenty, was marked by pencil and mesured by computer system(INTERGRAPH CO. USA) 2 times and the average value was used for date Processing. All attrition areas were measured 2 times and the average value was used for data processing The data were statistically analyzed by SAS program. The results of this study were as follows. 1. Total attrition area in Group I was larger than in Group II and III. 2. There was no significant difference in attrition area between right and left side in each group, but attrition area in Group III was larger than in Group I and II. 3. In Group I, Maxillary attrition area was larger than mandibular attrition area, but in Group ll and III, there was no significant difference in attrition area between maxilla and mandible. 4. In Group III, the attrition area of deviated side was target than undeviated side 5. There was no significant difference in attrition area between chewing side and non-chewing side in each group. 6. The total attrition area was unaffected by gender.

  • PDF

Palliative Care Practitioners' Perception toward Pediatric Palliative Care in the Republic of Korea (소아완화의료에 대한 호스피스 완화의료 전문기관 종사자의 인식)

  • Moon, Yi Ji;Shin, Hee Young;Kim, Min Sun;Song, In Gyu;Kim, Cho Hee;Yu, Juyoun;Park, Hye Yoon
    • Journal of Hospice and Palliative Care
    • /
    • v.22 no.1
    • /
    • pp.39-47
    • /
    • 2019
  • Purpose: This study was performed to investigate the current status of pediatric palliative care provision and how it is perceived by the palliative care experts. Methods: A descriptive study was conducted with 61 hospice institutions. From September through October 2017, a questionnaire was completed by experts from the participating institutions. Data were analyzed using SPSS 21.0. Results: Among 61 institutions, palliative care is currently provided for pediatric cancer patients by 11 institutions (18.0%), all of which are concentrated in Seoul, Incheon and Gyeonggi and Gyengsang provinces; 85.2% of all do not plan to provide specialized pediatric palliative care in the future. According to the experts, the main barriers in providing pediatric palliative care were the insufficient number of trained specialists regardless of the delivery type. Experts said that it was appropriate to intervene when children were diagnosed with cancer that was less likely to be cured (33.7%) and to move to palliative care institutions when their conditions worsened (38.2%); and it was necessary to establish a specialized pediatric palliative care system, independent from the existing institutions for adult patients (73.8%). Conclusion: It is necessary to develop an education program to establish a nationwide pediatric palliative care centers. Pediatric palliative care intervention should be provided upon diagnosis rather than at the point of death. Patients should be transferred to palliative care institutions after intervention by their existing pediatric palliative care team at the hospital is started.

A Case of Pseudodeficiency in a Potential Late Onset Pompe Disease Carrier, with Double Dual Variant, Each in cis Formation (Pseudodeficiency 및 potential late onset Pompe disease 보인자로 확인된 cis형 dual variant 돌연변이 두 개를 가진 여아 1례)

  • Seung Ho, Kim;Goo Lyeon, Kim;Young Pyo, Chang;Dong Hwan, Lee
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.22 no.2
    • /
    • pp.58-62
    • /
    • 2022
  • Pompe disease (PD) is an autosomal recessive genetic disorder caused by a deficiency of the lysosomal enzyme acid α-glucosidase (GAA). It is easy to hastily diagnose as patients if they have two pathogenic variants. Clinical pathologists misdiagnosed our infant and her mother as PD. Here, we report a case of pseudodeficiency in a potential late-onset Pompe disease (LOPD) carrier with a double dual variant, each in cis formation in a 3-month infant. The person who has two pathogenic variants was diagnosed as a carrier, not a patient. It was first reported in Korea. The patient had: two likely pathogenic heterozygous mutations on exon #4: c.752C>T (p.Ser251Leu), c.761C>T (p.Ser254Leu), and a heterozygous mutation on exon #12: c.1726G>A (p.Gly576Ser), also with a heterozygous mutation on exon #15: c.2065G>A (p.Glu689Lys). By presenting this case we emphasize the possibility of cis formation of genes which may cause pseudodeficiency, and potential LOPD carrier form. Hereby we suggest that thorough evaluation of GAA gene is essential among whom initially diagnosed as PD.

A Study on the Turnover Intention and Job Satisfaction of Dental Hygienists (치과위생사의 이직의도와 직무만족도에 관한 연구)

  • Yoon, Mi-Sook;Lee, Kyung-Hee;Choi, Mi-Sook
    • Journal of dental hygiene science
    • /
    • v.6 no.3
    • /
    • pp.147-152
    • /
    • 2006
  • The purpose of this study was to help decrease turnover and to make full use of dental hygienists and to help improve management by managers. After relevant literature and data were reviewed, a survey was conducted on dental hygienists, who worked at dental institutes in different areas, for about four months from September through December, 2004, to find out their turnover intention and job satisfaction level. When the collected data were analyzed, the following findings were given: 1. The collective average of the dental hygienists investigated in job satisfaction was $3.30{\pm}0.70$. By area, they expressed the best satisfaction at a clear role factors with a mean of $3.53{\pm}0.73$, and they were pleased with wages factors and promotion factors the least with an average of $3.14{\pm}0.70$ and $3.18{\pm}0.80$. 2. The collective average of the dental hygienists investigated in turnover intention was $3.23{\pm}0.77$. As for connections between general characteristics and turnover intention, By age, those who aged in 21 and 25 were most intended(p < 0.001). The unmarried dental hygienists were more intended than the married ones(p < 0.001). By type of hospital, those who worked at dental clinics were most intended(p< 0.01). By career, those who had worked at one to three years were intended the most(p < 0.001), and as to the length of service at current work places, those who had worked at their current work places for one to three years were intended the most(p < 0.001). By monthly mean pay, those whose pay ranged from 1.3 to 1.6 million won found their turnover most intended(p< 0.01). 3. Regarding correlation among turnover intention and job satisfaction were both inversed correlationship, and wages factor(r = -0.249, p < 0.01) and interrelationship factors(r = -0.218, p < 0.01) had a strong correlation to turnover intention, and clear role factors had a strong correlation to job contents factors by job satisfaction(r = 0.612, p < 0.01), and job satisfaction factors had a strong correlation to job contents factors(r = 0.759, p < 0.01).

  • PDF

A Study on the Environmental Condition and Safety in Dental Radiographic Room (치과 방사선 촬영실의 촬영실태와 방사선 안전관리 실태에 관한 조사 연구)

  • Kang, Eun-Ju;Lee, Kyung-Hee;Ju, On-Ju
    • Journal of dental hygiene science
    • /
    • v.5 no.2
    • /
    • pp.83-88
    • /
    • 2005
  • In spite of relatively low level of radiation dose used at dental clinics, long term exposure may be harmful, so radiation workers at dental clinics must be well aware of its danger. This study was radiation safety management by dental hygienists in order to take preventive measures for dental hygienists and suggest ideas to develop radiation safety training programs. For this, we contacted dental hygienists working at the local dental clinics for 4 months from December of 2003 to march of 2004 and obtained the following findings. 1. Regarding the intraoral radiographic method, the average daily photographing frequency of standard films stood at one to five pieces (47.5%), and the average weekly photographing frequency of digital radiation medicine stood at less than one piece (69.8%), and the average weekly photographing frequency of bitewing films stood at less than one piece (67.7%), and and the average weekly photographing frequency of occlusal films stood at less than one piece (95.5%), and the dentistries whose average weekly photographing frequency of pediatric films stood at one to five pieces accounted for 47.1 percent. 2. Regarding the extraoral radiographic method, the average weekly photographing frequency of panorama film stood at one to five pieces (63.7%), and less than one piece (20.9%), the average weekly photographing frequency of cephalometric film stood at less than one piece (72.3%), and one to five pieces (20.1%). 3. Concerning the radiation safety management training program, only 18.7% of total 278 surveyed attended the training progra., Attendance tendency of the training program by general characteristics showed statistically significant difference according to age (p<0.01), working experience (p<0.001), and marital status (p<0.01). 4. When asked about the protective equipments against radiation exposure, 40.6% of them said "modest", and 71.1% appeared equipped with led apron as a protective tool.

  • PDF

A COMPARATIVE STUDY ON THE PHYSICAL PROPERTIES OF ORTHODONTIC PLIERS ACCORDING TO TYPES OF STERILIZATION (멸균 방법에 따른 교정용 플라이어의 물성 변화에 대한 비교 연구)

  • Cho, Il-Je;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.28 no.2 s.67
    • /
    • pp.329-341
    • /
    • 1998
  • Sterilization has received much attention in orthodontic practices over the past several years. The present study was undertaken to investigate the effects of sterilization on the physical properties of orthodontic pliers-AEZ, Unitek, and Dentronix ligature cutters. This study was designed to examine the tips of ligature cutters before and after 200 and 400 sterilization cycles using the Bowmar RHT-1000, the Dentronix DDS-5000, and the Eschmann SES-2000. The tip surface and the fracture surface were observed with a scanning electron microscope. The microstructure was observed with an optical microscope. The hardness test was carried out with the mic개-Vickers hardness tester and the Rockwell C Scale hardness tester. The chemical composition was analyzed by energy dispersive X-ray spectrometer. The results of this study were as follows : 1. The number and the size of corrosion products on the tip surface and the proportion of cleavage planes in fractured specimen increased, but the hardness of the tip decreased in proportion to sterilization cycles. From these observations, it was considered that mechanical properities decreased in proportion to sterilization cycles. 2. The number and the size of chromium carbides increased in proportion to sterilization cycles. Coarse microstructure decreased mechanical properities. 3. The AEZ and Unitek ligature cutters were Fe-Cr stainless steels, but the Dentronix ligature cutter was Co-Cr alloy. There were many differences among manufactures, but the chemical composition was .not changed after sterilization cycles. 4. The tip edge of ligature cutter used in a clinic revealed microcracks with the SEM observation. Clinical experience confirmed that ligature cutters were gradually degraded by sterilization.

  • PDF

The comparison of landmark identification errors and reproducibility between conventional lateral cephalometric radiography and digital lateral cephalometric radiography (일반두부방사선계측사진과 디지털방사선계측사진의 계측점 식별의 오차 및 재현성에 관한 비교 연구)

  • Lee, Yang-Ku;Yang, Won-Sik;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.79-89
    • /
    • 2002
  • The purpose of this study is to evaluate the reproducibility and errors in landmark identification of conventional lateral cephalometric radiography and digital lateral cephalometric radiography. Fifteen conventional lateral cephalometric radiographs and fifteen digital lateral cephalometric radiographs were selected in adults with no considerations on sex and craniofacial forms. Each landmark was identified and expressed as the coordinate (x, y). The landmarks were classified into 3 groups. The landmarks of the first identification was T1, identification after one week was T2, and identification after one month was T3. The mean and standard deviation of identification errors between replicates were calculated according to the x and y coordinates. The errors between first identification and second identification were expressed as T2-T1(x), T2-T1(y) and those between first identification and third identification were expressed as T3-T1(x), T2-T1(y). Each was divided into conventional lateral cephalometric radiography and digital lateral cephalometric radiography. The independent t- test was used for statistical analysis of identification errors for the evaluation of reproducibility. The results of this study were as follows ; 1. Generally, the mean and standard deviation of landmark identification errors in digital lateral cephalometric radiography was smaller than those of conventional lateral cephalometric radiography. 2. Only a few landmarks showed statistically significant difference in identification error between conventional lateral cephalometric radiography and digital lateral cephalometric radiography. 3. The enhancement of image quality didn't guarantee decrease in landmark identification error and didn't affect tendency of landmark identification error.

Climatological Characteristics in the Variation of Soil temperature in Korea (우리나라 지중온도 변동의 기후학적 특성)

  • Kim Seoung-Ok;Suh Myoung-Seok;Kwak Chong-Heum
    • Journal of the Korean earth science society
    • /
    • v.26 no.1
    • /
    • pp.93-105
    • /
    • 2005
  • Climatological characteristics in the variation of soil temperatures in Korea were investigated using Korea Meterological Administration's observation data. And the impacts of soil moisture on the variation of soil temperature were examined using observed precipitation data. The climatological averages of soil temperatures are ranged from 14.4 to $15.0^{\circ}C$ regardless of depths. And they showed an latitudinal gradient with a warm temperature at the southern region and 'U' shape as in the air temperature with a high value along the coastal region. The relatively higher heat capacity and low conductivity of soil compared to those of the air resulted in the significant delay of the maximum and minimum date with depth. As a results, soil acts as a heat source during winter while a heat sink during summer. Global warming and urban heat island have increased the soil temperatures with an average rate $0.3\~0.5^{\circ}C/10-year$ as in the air temperature during last 30 years $(1973\~2002)$. However, the warming rate is maximized during spring contrary to the winter in the air temperature. The temporal variation of soil temperatures is strongly affected by that of soil moisture through an modification of the heat capacity and heat convection. In general, the increased soil moisture clearly decreased the temporal variations and increased the deep layer soil temperatures during cold season.

A study on the shear bond strength between Co-Cr denture base and relining materials (금속의치상과 의치이장재료 간의 결합력에 관한 연구)

  • Lee, Na-Young;Kim, Doo-Yong;Lee, Young-Soo;Park, Won-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.8-15
    • /
    • 2011
  • Purpose: This study evaluated the bonding strength of direct relining resin to Co-Cr denture base material according to surface treatment and immersion time. Materials and methods: In this study, Co-Cr alloy was used in hexagon shape. Each specimen was cut in flat surface, and sandblasted with $110\;{\mu}m$ $Al_2O_3$ for 1 minute. 54 specimens were divided into 3 groups; group A-control group, group B-applied with surface primer A, group C-applied with surface primer B. Self curing direct resin was used for this study. Each group was subdivided into another 3 groups according to the immersion time. After the wetting storage, shear bond strength of the specimens were measured with universal testing machine. The data were analyzed using two-way analysis of variance and Tukey post hoc method. Results: In experiment of sandblasting specimens, surface roughness of the alloy was the highest after 1 minute sandblasting. In experiment of testing shear bond strength, bonding strength was lowered on group B, C, A. There were significant differences between 3 groups. According to period, Bonding strength was the highest on 0 week storage group, and the weakest on 2 week storage group. But there were no significant differences between 3 periods. According to group and period, bonding strength of all group were lowered according to immersion time but there were no significant differences on group B and group C, but there was significant difference according to immersion time on group A. Conclusion: It is useful to sandblast and adopt metal primers when relining Co-Cr metal base dentures in chair-side.

Evaluation of the dose of 16-MDCT and 64-MDCT in case of Coronary Artery CT Angiography using Thermoluminescence Dosimeter (열형광선량계를 이용한 16-MDCT와 64-MDCT의 관상동맥 CT 혈관조영술 시 선량평가)

  • Kim, Sang-Tae;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.6
    • /
    • pp.336-343
    • /
    • 2010
  • Coronary artery CT angiography has short scanning length, the exposure dose is high. Therefore, it is required to study on the organ dose when using MDCT. We compared the differences between the absorbed dose and effective dose in the major organs assessing the absorbed dose in the major organs by 16-MDCT and 64-MDCT in the subjects with coronary artery CT angiography, the same protocol by 16-MDCT and 64-MDCT. As a result, the great orders of absorbed dose when conducting coronary artery CT angiography had been shown as heart, stomach, liver, pancreas, kidney, spleen, large intestine, lung, small intestine, thyroid gland, ovary, bladder, and orbit with the absorbed dose distribution of $0.538{\pm}0.026(Mean{\pm}SD,\;p<0.05)mGy{\sim}71.316{\pm}4.316mGy$ in 16-MDCT, and heart, stomach, pancreas, spleen, liver, kidney, small intestine, large intestine, lung, thyroid gland, ovary, bladder, and orbit with the absorbed dose distribution of $0.87{\pm}0.01mGy{\sim}115.26{\pm}1.59mGy$ in 64-MDCT, demonstrating some different distributions. The exposed doses to the patient per one time scanning with coronary artery CT angiography were $71.316{\pm}4.316mGy$ in 16-MDCT as the absorbed dose based on the heart and $115.26{\pm}1.59mGy$ in 64-MDCT. The effective doses were 7.41 mSv and 12.11 mSv in 16 and 64-MDCT, respectively. Taking into account the results of brain CT with 2.8 mSv that has comparatively large scanning length and size, facial CT 0.8 mSv, chest CT 5.7 mSv, pelvic CT 7.2 mSv, and abdominal and pelvic CT 14.4 mSv, it is very high considering the scanning length of 13 cm limited to the heart for the scanning range.