A numerical study on the effect of train-induced vibration in shield tunnel (쉴드터널 내부에 작용하는 열차진동 영향에 관한 수치해석적 연구)

  • Kwak, C.W.;Park, I.J.;Park, J.B.
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.2
    • /
    • pp.261-267
    • /
    • 2014
  • Various types of external loads can be applied to the tunnel structure. In a shield tunnel, the vibration from the train may affect the behavior of the adjacent ground. In this study, the railway-induced vibration was estimated and applied to the shield tunnel through 3D numerical simulation. The effective stress analysis based on the finite difference method and Finn model was performed to investigate the potential of liquefaction below the tunnel. Furthermore, pore water pressure and displacement were monitored on a time domain; consequently, the liquefaction potential and dynamic response of the shield tunnel were analyzed. Consequently, it is confirmed that the generation of excess pore water pressure by train-induced vibrating load, however, the amount does not meaningfully affect the potential of liquefaction.

Vibration Reduction Effects of Stay Cable Due to Friction Damper (마찰댐퍼에 의한 사장 케이블의 진동저감 효과)

  • Kim, Hyung Ku;Yhim, Sung Soon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.2
    • /
    • pp.54-61
    • /
    • 2013
  • Stay cable has a strong axial rigidity due to large initial tension and, on the other hand, it has a weak laterally flexural rigidity. Wind loads or traffic loads cause the cables to vibrate significantly and affect the mechanical properties and the performance of cables of cable-stayed bridge (CSB). Therefore, the development of vibration reduction design is an urgent task to control the vibration vulnerable long-span bridges. As Friction damper (FD) shows to reduce the amplitude and duration time of vibration of cable of CSB from measured date in field test, friction damper can be considered that it is effective device significantly to reduce the amplitude and duration time in vibration of cable of CSB under traffic load, wind load and so on. Vibration characteristics of cable can change according to manufacturing method and type of established form. Nevertheless, analysis method in this study can present the design of friction damper for vibration reduction of cable of cable-stayed bridge from now on.

Vibratory Hub Loads of Helicopters due to Uncertainty of Composite Blade Properties (복합재료 블레이드의 불확실성을 고려한 헬리콥터 허브 진동하중 해석)

  • You, Young-Hyun;Jung, Sung-Nam
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.7
    • /
    • pp.634-641
    • /
    • 2009
  • In this work, the behavior of vibratory hub loads induced due to the uncertainties of composite material properties for each of the participating rotor blades is investigated. The random material properties of composites available from the existing experimental data are processed by using the Monte-Carlo simulation technique to obtain the stochastic distribution of sectional stiffnesses of composite blades. The coefficients of variation (standard deviation divided by the mean) obtained from the sectional stiffness constants are used as an input to the comprehensive aeroelastic analysis code that can evaluate the hub loads of a rotor system. It is found that the uncertainty effects of composite material properties inevitably bring a dissimilarity to the rotor system. The influence of hub vibration response with respect to the individual stiffness (flatwise bending, chordwise bending and torsion) changes is also identified.

Development of Analysis Method and Computer Program for Train-induced Ground Vibration (철도연변 지반진동 예측기법 및 전산프로그램 개발)

  • 황선근;엄기영;고태훈;이종재
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.203-210
    • /
    • 2000
  • Recently, environmental vibration by train operation has been getting such an attention that the ISO puts it into the environmental vibration regulation. However, the reasonable and efficient countermeasures against such a kind of vibration is not well established, especially in residential areas near the railroad. Therefore, it is very important to estimate the ground vibration induced by the train operation for the design and construction of track supporting structures as well as structures near the track. In this study a model estimating dynamic load on track due to train operation and analysis technique of propagation of ground vibration were developed. Futhermore, the estimated vibration from this model was compared with the actual measurement data in the field and found to be reasonably acceptable.

  • PDF

Influence of Loading Sizes on Natural Frequency of Composite Laminates (복합적층판의 고유진동수에 대한 하중 크기의 영향)

  • Han, Bong-Koo;Suck, Ju-Won
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.3
    • /
    • pp.42-47
    • /
    • 2011
  • A method of calculating natural frequencies corresponding to the modes of vibration of beams and tower structures with irregular cross sections and arbitrary boundary conditions was developed. The result is compared with that of the beam theory. Finite difference method is used for this purpose. The influence of the $D_{22}$ stiffness on the natural frequency is rigorously investigated. In this paper, the relation between the applied loading sizes and the natural frequency of vibration of some structural elements is presented. The results of application of this method to steel bridge and reinforced concrete slab bridge by using specially orthotropic plate theory is presented.

Critical Loads of Tapered Beck's Columns with Clamped and Spring Supports (일단고정 타단스프링으로 지지된 변단면 Beck 기둥의 임계하중)

  • Kim Suk-Ki;Park Kwang-Kyou;Lee Byoung-Koo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.1 s.71
    • /
    • pp.85-92
    • /
    • 2006
  • This paper investigates critical loads of the tapered Beck's columns with clamped and spring supports, subjected to a subtangential follower force. The linearly tapered columns with the solid rectangular cross-section is adopted as the column taper. The differential equation governing free vibrations of such Beck's columns is derived using the Bemoulli-Euler beam theory. Both divergence and flutter critical loads are calculated from the load-frequency curves which are obtained by solving the differential equation. The critical loads are presented as functions of various non-dimensional system parameters: the taper type, the subtangential parameter and the spring stiffness.

dynamic Analysis of Ring-Stiffened Axisymmetric Shells (링보강 축대칭 쉘 구조물의 동적 해석)

  • 황철성
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.2
    • /
    • pp.83-98
    • /
    • 2000
  • 자오방향 및 주변방향으로 피르스트레스트 하중이 작용된 축대칭 쉘 구조물을 기하학적으로 축대칭인 구조물의 특성을 최대한으로 이용할 수 있도록 회전 링요소로 모델화하였다 보강링 요소의 모델은 축대칭 쉘요소를 이용하였으며 본체 구조물과 절점에서 부착되있는 것으로 가정하여 이의 편심을 고려하였다 유체-구조물의 상호관계는 접촉면에서 구조물의 가속도에 비례한 부가질량으로 표현하였으며 부가질량은 유체를 비점성 비압축 및 비회전을 가정하여 유한요소법에 의해 구하였다 이에 대한 수치해석을 통하여 고유진동해석 및 지진하중을 주하중으로 한 동적해석을 실시하였다 프로그램을 통하여 해석한 결과를 프리스트레스 하중 하에서 고유진동수에 대한 정해와 비교한 결과 20개의 요소로 모델링한 경우에서도 정해와 근접한 해를 얻을 수 있었다 또한 내부유체가 있는 경우와 링보강을 한 경우에 대한 고유진동수를 문헌과 비교한 결과 근접한 해를 얻을 수 있었다.

  • PDF

Mean Square Response Analysis of the Tall Building to Hazard Fluctuating Wind Loads (재난변동풍하중을 받는 고층건물의 평균자승응해석)

  • Oh, Jong Seop;Hwang, Eui Jin;Ryu, Ji Hyeob
    • Journal of Korean Society of Disaster and Security
    • /
    • v.6 no.3
    • /
    • pp.1-8
    • /
    • 2013
  • Based on random vibration theory, a procedure for calculating the dynamic response of the tall building to time-dependent random excitation is developed. In this paper, the fluctuating along- wind load is assumed as time-dependent random process described by the time-independent random process with deterministic function during a short duration of time. By deterministic function A(t)=1-exp($-{\beta}t$), the absolute value square of oscillatory function is represented from author's studies. The time-dependent random response spectral density is represented by using the absolute value square of oscillatory function and equivalent wind load spectrum of Solari. Especially, dynamic mean square response of the tall building subjected to fluctuating wind loads was derived as analysis function by the Cauchy's Integral Formula and Residue Theorem. As analysis examples, there were compared the numerical integral analytic results with the analysis fun. results by dynamic properties of the tall uilding.

Helicopter Active Airframe Vibration Control Simulations Using an Exhaustive Test Method (Exhaustive 시험 기법을 이용한 헬리콥터 능동 기체 진동 제어 시뮬레이션)

  • Park, Byeong-Hyeon;Lee, Ye-Lin;Park, Jae-Sang
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.11
    • /
    • pp.791-800
    • /
    • 2022
  • The number and locations of force generators and their force directions of Active Vibration Control System(AVCS) are important to maximize the airframe vibration reduction performance of helicopters. The present AVCS simulation using an exhaustive test method attempts to determine the best number and locations of force generators and their force directions for maximization of the airframe vibration reduction performance of UH-60A helicopter at 158 knots. The 4P hub vibratory loads of the UH-60A helicopter are calculated using DYMORE II, a nonlinear multibody dynamics analysis code, and MSC.NASTRAN is used to predict the vibration responses of the UH-60A airframe. The AVCS framework with an exhaustive test method is constructed using MATLAB Simulink. As a result, when applying AVCS with the optimal combination of the force generators, the 4P airframe vibration responses of UH-60A helicopter are reduced by from 19.35% to 98.07% compared to the baseline results without AVCS.

A Study on the Structural Dynamic Modification of sub-structure of Clean Room using VSD System (반도체 크린룸 구조물의 하중 측정 시스템을 이용한 동특성 개선에 관한 연구)

  • 백재호;이홍기;손성완
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1099-1106
    • /
    • 2003
  • 진동에 민감한 각종 정밀장비를 갖추고 있는 공장구조물은 설립하는 설계 초기단계에서부터 정밀장비가 정상 운용을 위하여 공장구조물의 진동허용규제치 및 동특성허용규제치를 결정해야 한다. 이를 만족할 수 있도록 공장구조물 설계시 진동측면에 대하여 동적 특성을 검토해야만 한다. 이때 반드시 필요한 자료로 정밀장비 Maker에게서 제공되는 진동허용규제치 및 구조물의 동특성허용규제치 등 설치시방의 상세한 자료를 제공받아야 한다 이러한 선계조건을 만족시켜주기 위한 방안으로 외부에서 정밀장비로 유입되는 진동에 대한 진동절연을 위하여 진동전달률 이론을 적용하여 방진효율 산출하는 방법과 정밀장비에서 발생하는 동하중을 고려하여 공장구조물에 대한 동적설계를 수행하는 것으로, 구조물 동특성을 요구되는 만큼 구조물 동특성 변경 SDM(Structural Dynamic Modifacation)방법이 주로 활용된다. 이에 본 연구에서는 앞서 언급한 구조물의 동적설계시 후자조건인 구조물의 동특성을 변경하고자 하는 경우에 실구조물에 하중을 정량적으로 조절하며 가할 수 있는 VSD 시스템을 이용하여 구조물의 동특성을 변화시키는 것을 동적해석으로 예측하였고, 현장에서 실제 동적실험으로 구한 결과를 동적설계 목표치와 비교하여 유용성에 대하여 확인하였다.

  • PDF