• Title/Summary/Keyword: 진동판

Search Result 733, Processing Time 0.023 seconds

Application of Semi-active TMD for Floor Vibration Control (바닥판 구조물의 진동제어를 위한 준능동 TMD의 적용)

  • Kim, Gee-Cheol;Kwak, Chul-Seung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.5
    • /
    • pp.49-56
    • /
    • 2007
  • Passive, active and semi-active control system are classified in floor vibration control system by providing control force. This paper discusses the application of a new class of semi-active TMD(MR-TMD), for the reduction or floor vibrations due to machine and human movements. This MR-TMD consists of passive TMD and MR damper. Here, displacement-based control methods are used to assess the performance of this STMD(MR-TMD). And, skyhook and the groundhook algorithm are applied to a single degree of freedom system representative of building floors. If the allowed operation space of tuned mass is limited in MR-TMD system, skyhook algorithm is more efficient than groundhook algorithm for floor vibration control. Hybrid control method demonstrates the efficiency of MR-TMD with respect to another methods.

  • PDF

Bending, Free Vibration and Buckling Analysis of Anisotropic Composite Laminated Plate and Shell Structures (비등방성 복합적층판 및 쉘 구조의 휨, 자유진동 및 좌굴해석)

  • Yoon, Seok Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.11 no.1 s.38
    • /
    • pp.55-67
    • /
    • 1999
  • The ratios of elastic to shear modulus of the structures as laminated composite plates and shells, are very large. They are much susceptible to effect of shear deformation. In order to obtain the accurate solutions of laminated composite plate and shells, the effects of shear strain should be considered for the analysis and design of them. Especially, the more exact solution can be obtained in applying to higher-order shear deformation theory. Therefore, in this paper, the third-order shear deformation theory is used to present the distributions of bending, the characteristics of natural frequencies and the buckling load according to the effects of ply orientation, number of layers for the laminated composite plates and shells with simply supported boundary conditions.

  • PDF

Viscoelastic Bending, Vibration and Buckling Analysis of Laminated Composite Plates on Two-parameter Elastic Foundation (2개 매개변수를 갖는 탄성지반위에 놓인 복합재료 적층판의 점탄성적 휨, 진동 좌굴해석)

  • Han, SungCheon;Chang, Suk Yoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.5
    • /
    • pp.443-455
    • /
    • 2001
  • An energy method has been used for an elastic formulation of bending vibration and buckling analysis of laminated composite plates on two-parameter elastic foundations. A quasi-elastic method is used for the solution of viscoelastic analysis of the laminated composite plates. The third-order shear deformation theory is applied by using the double-fourier series. To validate the derived equations the obtained displacements for simply supported orthotropic plates on elastic foundations are compared with those of LUSAS program Numerical results of the viscoelastic bending vibration and buckling analysis are presented to show the effects of layup sequence number of layers material anisotropy and shear modulus of foundations.

  • PDF

The Control of Vertical Vibration of Building Slabs using Tuned Mass Dampers (동조질량 감쇠기에 의한 건물 바닥판의 연직진동제어)

  • 이동근;김진구;안상경
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.103-114
    • /
    • 1998
  • The floors of building structures equipped with vibrating machines can be susceptible to large vibration as a result of resonance or beating. Such a vibration can be reduced efficiently by using tuned mass dampers. However, the effectiveness of the damper depends greatly on the location and the natural frequency of the damper. To determine the optimum damper location is especially important since the dynamic behavior of a building structure varies with the location of the input loading. To this end, it is intended to decide the location and natural frequency of tuned mass dampers for reducing vibration of both loaded floors and floors located nearby the loaded floors considering the location and frequency components of the loading. The Vector composition method and the super elements are used th obtain the responses in steady states, and the optimum damper location and natural frequencies were found with the given damper mass.

  • PDF

Modeling of Walking Loads for Floor Vibration Analysis (바닥판 진동해석을 위한 보행하중의 모형화)

  • 김기철;최균호;이동근
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.1
    • /
    • pp.173-188
    • /
    • 2002
  • In General, the measured loads and load-time function suggested by Bachmann iota walking are used for vibration analysis of structures subjected to footstep loads. It is not easy to measure walking loads because they we influenced by various parameters. Therefore, it is needed to model the walking loads that can be applied to structure analysis. Parameter study is used for the walking loads having various walking frequency for vibration analysis of structures under walking loads. In this study, walking loads were measured directly by using a force plate within two load cells, and the parameters of the walking loads were analyzed. The measured walking loads are decomposed into harmonic loads by using the Fouler series. Functional relationship between the walking frequency and the Fourier coefficients can be derived from the coefficients of harmonic loads obtained by the decomposition process, and the walking loads were formulated. It is possible to apply the venerated walking loads easily or conveniently by the proposed equation to the analysis of a structure subjected to walking loads.

Evaluation of Vertical Vibration Performance of Tridimensional Hybrid Isolation System for Traffic Loads (교통하중에 대한 3차원 하이브리드 면진시스템의 수직 진동성능 평가)

  • Yonghun Lee;Sang-Hyun Lee;Moo-Won Hur
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.70-81
    • /
    • 2024
  • In this study, Tridimensional Hybrid Isolation System(THIS) was proposed as a vibration isolator for traffic loads, combining vertical and horizontal isolation systems. Its efficacy in improving serviceability for vertical vibration was analytically evaluated. Firstly, for the analysis, the major vibration modes of the existing apartment were identified through eigenvalue analysis for the system and pulse response analysis for the bedroom slab using commercial structural analysis software. Subsequently, a 16-story model with horizontal, vertical and rotational degrees of freedom for each slab was numerically organized to represent the achieved modes. The dynamic analysis for the measured acceleration from an adjacent ground to high-speed railway was performed by state-space equations with the stiffness and damping ratio of THIS as variables. The result indicated that as the vertical period ratio increased, the threshold period ratio where the slab response started to be suppressed varied. Specifically, when the period ratio is greater than or equal to 5, the acceleration levels of all slabs decreased to approximately 70% or less compared to the non-isolated condition. On the other hand, it was ascertained that the influence of damping ratios on the response control of THIS is inconsequential in the analysis. Finally, the improvement in vertical vibration performance of THIS was evaluated according to design guidelines for floor vibration of AIJ, SCI and AISC. It was confirmed that, after the application of THIS, the residential performance criteria were met, whereas the non-isolated structure failed to satisfy them.

A Study on the Sound Absorption Characteristic of Glass Wool Structures Covered by Punched Steel Plate (유공함석판으로 보호된 글라스울 흡음구조체의 흡음특성에 관한 연구)

  • 김석홍;이상엽;권형오
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.65-69
    • /
    • 1991
  • 소음제어대책 수립시, 흡음구조는 공조용소음기, 공업용소음기, Enclosure, 실 내 흡음판등에 폭넓게 이용되고 있다. 흡음구조의 재료중 글라스울은 뛰어난 흡음성능과 고온에서의 내구성 및 난연성등으로 인하여 여러 흡음재료중에 서 가장 많이 이용되고 있으나 글라스율 미립자의 비산 및 강도문제로 글라 스율에 글라스 클로스(Glass Cloth), P.E.Film등과 같은 글라스울 비산방지막 과 유공함석판을 붙인 흡음구조체로 제작하여 이용하는 것이 일반적이다. 국 내외적으로 글라스울만의 흡음율 데이타는 각종 문헌등에 많이 발표되어 있 으나 글라스울에 글라스울 비산방지막과 유공함석판을 붙인 흡음구조체의 흡음율데이타는 거의 없는 실정이다. 본 연구에서는 이러한 글라스울 흡음구 조체의 글라스울의 밀도, 글라스울 비산방지막의 종류, 유공함석판의 유공치 수 등에 따른 흡음특성을 잔향실법 흡음율측정방법에 의해 측정 평가하고 이들을 상호 비교검토하여 각종 소음 제어대책의 기초 설계자료로 제시하고 자 한다.

  • PDF

A Study on the Transmission Path and Vibrosolating Character of Shipboard Structure-borne noise (SEA법에 의한 선박고체소음의 전파경로와 방진특성에 관한 연구)

  • 김사수;현명환;이도경;권종현;안시영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.223-230
    • /
    • 1995
  • 본 연구에서는 선박소음해석을 수행하기 위한 기초작업으로서 실선 선박모델을 크게 3가지 경우로 구분하여 모델링 하였으며, SEA법을 적용하여 고체소음의 전달손실을 이론적으로 예측할 수 있는 방법을 제시하였으며, 또한 STL을 도입하여 각 요소간의 에너지 흐름 및 구성판요소의 재료별 방진효과를 알아보았다. 이 방법의 결과 다음과 같은 결론을 얻을 수 있었다. 1) 내장판의 종류에 따른 전달특성은 고주파 대역에서는 plywood, 저주파 대 역에서는 rockwool이 높은 손실값을 보였으며, glasswool은 전 주파수 대역에서 고른 손실값을 가짐을 확인하였다. 2) 기진원으로부터의 거리가 멀어짐에 따라 내장판의 효과가 크게 나타나며, 기진원의 근방 요소에서는 내장판의 효과보다는 강판의 두께의 영향이 두드 러짐을 알 수 있었다. 3) 내장판 요소중 plywood의 방진효과가 가장 크게 나타남을 알 수 있었다. 4) 본 SEA법에 의한 연구에서는 구성 판요소의 재질과 두께에 따른 고쳇음 의 전달특성을 이론적으로 해석하였으며, 차후 실험을 통한 검증이 요구되어 진다.

  • PDF

Dynamic Response Analysis of Stiffened Plates Subjected to Moving Loads (이동하중을 받는 보강판의 동응답해석)

  • 정정훈;정태영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.124-129
    • /
    • 1992
  • 이동 집중력 및 집중질량에 의한 이동하중을 받는 직사각형 보강판에 대하 여 보강재효과집중 모델링방법에 의거하여 보강판을 등방성 박판 및 보강재 효과를 반영한 등가보요소로 이루어진 판-보 조합체로 유한요소 모델링하고 Newmark의 직접 시간적분법을 이용한 동응답 해석방법을 정식화하였다. 일 련의 수치계산 예를 통하여 본 연구에서 제시한 방법이 이동하중을 받는 보 강판의 동응답 해석문제에 효과적으로 적용될 수 있음을 확인하였다. 아울러 parametric study를 통하여 이동하중이 작용하는 보강판의 동응답특성은 이 동하중의 질량효과를 고려하는 경우와 고려하지 않는 경우 매우 달라지며, 이동하중에 의한 동적응답은 이동속도가 증가할수록 정하중에 의한 응답보 다 증폭되어 나타나고 증폭비율이 질량효과를 고려할 경우 훨씬 더 커짐을 확인하였다.

  • PDF

A study for the Improvement of the Plane Speaker by Time-Averaged Holographic Interferometry (時間 平均 롤러그래픽 干涉計에 의한 平面스피이커의 改善에 관한 硏究)

  • 이기백;김수광;안경면;이병훈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.3
    • /
    • pp.285-291
    • /
    • 1986
  • The plane speaker is inspected by the free vibration theory, the sound pressure, and the holographic interferometry. It is shown that time-average holographic interferometry is useful for the vibration analysis of the plane speaker. The position of supporter dertermined experimentally and theoretically, the value of r/a, is 0.68. Theoretical analysis of the free vibration for the plate agrees pretty well with the experimental results. The plane speaker is distorted vibrationally by the suppoter, but the distortion is not seen in the newly designed speaker.