• Title/Summary/Keyword: 진동파워

Search Result 310, Processing Time 0.03 seconds

Transient Power Flow Analysis of Beam and Plate (과도 입력파워에 대한 보와 평판의 파워흐름해석)

  • Hwang, Dae-Woong;Seo, Seong-Hoon;Kwon, Hyun-Wung;Hong, Suk-Yoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.7 s.124
    • /
    • pp.624-631
    • /
    • 2007
  • PFA (power flow analysis) has been recognized as a useful method in vibration analysis of medium-to-high frequency ranges. Until now, PFA method has been developed for steady-state vibration problems. In this paper, PFA method has been expanded to transient problem. New energy governing equations are derived considering time dependent terms in beam and plate. Analytic solutions of those equations are found in simple beam and plate, and are verified by comparing with modal solutions.

Vibration Power Flow Analysis of Coupled Co-planar Orthotropic Plates (동일 평면상에서 연성된 직교이방성 평판의 진동파워흐름해석)

  • Song, Jee-Hun;Park, Do-Hyun;Hong, Suk-Yoon;Kil, Hyun-Gwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.9
    • /
    • pp.856-862
    • /
    • 2010
  • In this paper, the power flow analysis(PFA) method was developed to predict the vibrational responses of coupled co-planar orthotropic plates in frequencies ranging from medium to high. To cover the power transmission and reflection at the joint of the orthotropic plates, the wave transmission approach is applied with the assumption that all the incident waves are normal to the joint. Through numerical analyses, the power flow energy density and intensity fields of coupled co-planar orthotropic plates were compared with those of classical modal solutions by changing the frequency and internal loss factor, and they show good agreement in terms of the global decay and the attenuation patterns of the energy density.

Comparison of Damping for Steel Tall Buildings by Half Power Bandwidth and Random Decrement Method (철골조 고층건물의 하프파워법과 RD법에 의한 감쇠율 비교)

  • Yoon, Sung-Won;Ju, Young Kyu;Shin, Sang Jun
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.1
    • /
    • pp.107-115
    • /
    • 2007
  • In this paper, the damping ratios of two methods, namely the half-power bandwidth method and random decrement method from the vibration measurement were examined. Ambient vibration tests were conducted on two steel-framed and one composite tall building ranging from 27 to 36 stories. The performance of the half-power bandwidth method was investigated using four sample sizes, such as 1024, 2048, 4096 and 8192. Damping by the half-power bandwidth method is slightly more overestimated than the random decrement method due to insufficient record length. Damping evaluation by the half-power bandwidth method was found to be enhanced when using the narrower bandwidth with long recorded data.

Calculation of the ultrasonic radiation force acting on a rigid circular cone and the study on the metrology for the acoustic power measurement (강체원뿔표적에 대한 초음파 방사힘 계산과 음향파워측정모델에 관한 연구)

  • Kyungmin Baik;Jooho Lee;Elmina B. C. Fritzie;Yong Tae Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.335-343
    • /
    • 2024
  • This paper came up with the theoretical modelling of the metrology for the acoustic power using ultrasonic radiation force and showed some theoretical results. In order to do this, a scattering model for a rigid circular cone based upon the Kirchhoff approximation was made, which was followed by the calculation of acoustic power, and then, was converted to the radiation force. From these works, it provided the accuracy and limitation of the conventional method using a circular cone, and the expanded metrology modelling that can be applied to a circular cone with arbitrary apex angle. Using these, this study provided the dependence of the metrology for the acoustic power using ultrasonic radiation force on the frequency and the size of the target. As a result, the correction was yielded in the value of the acoustic power calculated by the suggested International Electrotechnical Commission (IEC) method, which needs to be added when the frequency and the size of the target was considered.

A Technique for Calculations of Power Flow in Structures Using MSC/NASTRAN and PCL (MSC/NASTRAN 및 PCL을 이용한 구조물 내의 진동 파워 흐름 해석 기법)

  • 홍진숙
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.8
    • /
    • pp.303-313
    • /
    • 2001
  • The identification of power flow in dynamically loaded structures Is essential in the analysis of structure-borne noise. However there are no general purpose tools to estimate powers flow. To make matters worse. It is very difficult to measure it. The power flow can be formulated in terms of balance forces(ELFORCE) at each element and velocities at the associated node obtained with MSC/NASTHAN. In this paper the procedure which is consist of the computations of the balance forces of al1 elements and the velocities at all nodes using MSC/NASTRAN. The calculations of the power f1ow at each element using PCL(PATRAN Command Language) and the Preparation of post -processes is set UP.

  • PDF

Vibration Experiments of the Cylindrical Structure for Verifying the Reliability of Power Flow Finite Element Method (파워흐름해석법의 신뢰성 검증을 위한 원통형 구조물의 진동실험)

  • 이호원;홍석윤;박영호;길현권;김창열;전재진;류정수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.290-297
    • /
    • 2002
  • Vibration experiments have been performed to observe the analytic characteristics of power How finite element method(PFFEM) for the reinforced cylindrical structure. For this, the vibration experimental results are compared with the numerical solutions obtained by PFFEM in medium-to-high frequency ranges. Input Power into the experimental structure is measured using the impedance head adhered to the exciter, and that input power is used for the vibration analysis. Using the developed PFFEM program(PFADS), the reinforced cylindrical structure modeled by beam and plate elements is analyzed, and very reliable results for PFFEM are obtained by the comparisons of the experimental results.

  • PDF

Estimation of Vibrational Power Transmitted from Vibration Source to Supporting Structure - Estimation and Measurement of Vibrational Power Transmitted in the Horizontal Direction - (진동원으로부터 지지구조물에 전달되는 진동 파워의 추정 - 수평방향으로 전달되는 진동파워의 추정 및 측정 -)

  • 김재철;주진수
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1137-1143
    • /
    • 1998
  • This paper describes the method to measure of the vibrational power transmitted from the vibration source to the supporting structure in the horizontal direction. Generally, it is impossible to measure horizontal forces at the coupling points. However. the vibrational Power transmitted in the horizontal direction can be measured by using indirect method that is based on the mechanical impedance and velocities at the coupling points. We proposed the method to estimate the vibrational power when the vibration source and supporting structure cannot be separated. In this paper. the vibrational power transmitted in the horizontal direction is also estimated by using this method. The estimated and measured results of the mobilities at the coupling point and vibrational power in the horizontal direction are compared. It is shown that the estimated results agree well with the measured results. For the supporting structure with multiple coupling points, the other coupling points should be considered for measuring the vibrational power transmitted through one coupling points. We examine the effects of other coupling points and measure the vibrational power without considering the other coupling points.

  • PDF

Research on Frequency Average Analysis of vibrational Power Flow Analysis (진동파워흐름해석의 주파수 평균해석에 대한 연구)

  • Lee, Jea-Min;Hong, Suk-Yoon;Park, Young-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.971-977
    • /
    • 2005
  • Power Flow Analysis (PFA) is developed for the effective predictions of frequency-averaged vibrational response in medium-to-high frequency ranges. In PFA, the power coefficients of semi-infinite structure and for-field energy density are used to predict the vibrational responses of structures. Generally, at high frequencies, PFA can predict narrow-band frequency-averaged vibrational responses of built-up structures. However, in low- to medium frequency ranges, the dynamic responses obtained by PFA represent broad-band frequency-averaged vibrational energy densities. For the prediction of vibrational response variance in Power Flow Finite Element Method (PFFEM), the variances of input power and joint element matrix describing structural coupling relationship are derived. Finally, for the validity of developed formulation, numerical examples for two co-planer plates are performed and the vibrational response variance of the structure are compared with the results of classical and PFFEM solutions.

  • PDF

Vibration Power Flow Analysis of Coupled Co-planar Rectangular Plates (동일 평면상에서 연성된 직사각형 평판의 진동파워흐름해석)

  • 박도현;홍석윤;길현권
    • Journal of KSNVE
    • /
    • v.8 no.6
    • /
    • pp.1053-1061
    • /
    • 1998
  • In this paper. the power flow analysis(PFA) method is applied to the prediction of the vibrational energy density and intensity of coupled co-planar plates. To cover the energy transmission and reflection at the joint of the plates. the wave transmission approach is Introduced with the assumption that all the incident waves are normal to the joint. By changing the frequency ranges and internal loss factors. we have obtained the reliable PFA results. and compared them with the analytical exact solutions.

  • PDF

Sound Intensity Measurement in Near Field of Thin Plate Using Strain Gauge Bridge (스트레인 게이지 브리지를 이용한 얇은 평판의 근접장 음향 인텐시티 측정 방법론)

  • 김용조;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.71-76
    • /
    • 1996
  • 스트레인 게이지 브리지와 한개의 진동변위 탐촉자를 이용하여 평판의 근접장에서 음향 인텐시티를 측정하는 방법에 대하여 설명하였다. 또한 구조감쇠의 모델링을 통하여 음향방사파워에 대한 내부손실파워의 비를 나타내는 계수를 정의하여 내부손실파워의 정도를 평가하는 척도로 사용할 수 있음을 설명하였다. 임의의 경계조건을 가지는 평판에서 2개의 마이크로폰과 1개의 가속계를 이용하여 근사적으로 측정된 음향 인텐시티와 본고에서 제시한 방법으로 측정한 음향 인텐시티가 거의 일치함을 보이므로써 제시된 측정방법의 타당성을 검증하였다. 실험에 사용된 계(system)는 일반적인 해석에서 유체부하를 무시할 수 있는 계로 평판내부의 에너지 흐름에 비하여 외부로 방사되는 소음의 에너지 흐름이 매우 작기 때문에 평판내부의 에너지 흐름으로부터 방사되는 소음의 에너지 흐름을 알아내는 것이 매우 어려울 것으로 예상되었으나 본고에 제시된 방법으로 좋은 결과를 얻을 수 있었다. 앞으로 본 방법의 측정 오차에 대한 면밀한 고찰이 있어야 할 것이다. 그리고 평판의 내부손실이 비교적 큰 경우에 본 방법의 실험적으로 검증이 필요할 것이다. 또한 실질적인 문제에 응용되어 얼마만큼 유용한 정보를 제공할 것인가를 살펴보아야 할 것이다.

  • PDF