• Title/Summary/Keyword: 진동절연

Search Result 214, Processing Time 0.027 seconds

Pyroshock Isolation Performance Test using Wiremesh Isolators (와이어메쉬 절연계의 파이로 충격 절연 성능 시험)

  • Youn, Se-Hyun;Jang, Young-Soon;Han, Jae-Hung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.9
    • /
    • pp.923-928
    • /
    • 2008
  • Pyrotechnic shock or pyroshock is characterized as a transient vibration phenomenon which shows large acceleration and high frequency range up to 10kHz during the operation of separation devices where explosives are used. During the flight of a launch vehicle, pyroshock is mainly generated at several events such as satellite separation, fairing separation and stage separation. In this paper, wiremesh isolators are introduced and several types of isolators are manufactured for the performance tests. For the investigation of typical characteristics of wiremesh isolators, compressive loading tests are basically performed and pyroshock tests are accomplished to confirm pyroshock isolation ability of each wiremesh isolator by using 4Kg dummy mass.

가스절연개폐장치에 있어서 급준과도진동파 전압의 발생과 절연특성

  • 하촌달웅;이복희
    • 전기의세계
    • /
    • v.38 no.1
    • /
    • pp.21-30
    • /
    • 1989
  • 가스 절연개폐장치(GIS)에 있어서 단로기 또는 차단기의 개폐조작시나 자락고장이 생겼을 때는 급준과도전압(VFT)가 발생한다. 이 급준파의 크기는 단로기의 개폐조작시 재점호가 일어날 때가 대지절연파괴를 일으킬때의 극간전압차에 의하여 결정되며, 반사와 전반에 의해 중첩된 진행파로 되는 이른바 급준과도과전압(VFTO)로 된다. 이 VFT의 상승율은 표준뢰임펄스전압보다 크며, 최초의 파두장은 4-7[ns]의 것도 있다. 또 이 VFT전압은 GIS내부 뿐만 아니라 가공 송전선과 대지간, GIS의 용기와 대지사이 등 외부에도 나타난다. 따라서 GIS의 내부와 외부에서 VFT의 스트레스가 나타나므로 GIS의 설계시에 충분히 고려하여야만 된다. 지락고장에 의해 발생되는 용기과도전압(TEV)도 불꽃방전시에는 인가전압의 2배 정도로 되는 경우도 있으므로 절연설계 및 현장시험시에 고려할 필요가 있다. 단로기의 개폐조작시 발생하는 VFT의 피이크치를 최악의 경우로 상정할 때는 절연레벨을 상당히 저하시키며, 특히 GIS내에 돌기물과 같은 이물질이 존재하여 불평등전계를 형성할 때는 절연파괴전압이 대단히 전하된다. 변압기나 부싱 등과 같은 전력기기에서는 외함과 접지사이의 전압을 제한하여 설계할 필요가 있으며 용기와 대지사이의 외부과도과전압(FTO)를 저감시키기 위해서는 GIS의 외함을 각각 분할하여 제작할 필요가 있다.

  • PDF

The Influence of Interphase Condition and Fiber Content on the Dynamic Properties of Short-fiber Reinforced Rubber (계면상 조건과 단섬유 함유량이 강화고무의 동적 특성에 미치는 영향)

  • 류상렬;이동주
    • Composites Research
    • /
    • v.13 no.3
    • /
    • pp.30-37
    • /
    • 2000
  • The dynamic properties of short-fiber reinforced Chloroprene rubber have been studied as functions of interphase conditions and fiber content. The loss factor generally decreased with fiber content and showed different patterns according to interphase conditions. The better interphase condition showed the lower loss modulus, $E_2$. Also, the dynamic ratio decreased with fiber content and rapidly decreased in the case of double coatings, i.e., model C. Therefore, the short-fiber reinforced rubber could have the better isolation in frequency ratio($\sqrt{2}$ min.) compared to frequency ratio($\sqrt{2}$ max.). And we have investigate the possibility of applying short-fiber reinforced rubber to automotive engine mount.

  • PDF

The Study on Vibration Isolation of Industrial Turbo-fan (산업용 터보팬의 진동절연에 관한 연구)

  • Park, Ik-Pil;Kim, Dong-Young;Kwon, Yong-Soo;Ahn, Chan-Woo
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.609-615
    • /
    • 2001
  • A turbo-fan is easily exposed to noise and vibration as against other industrial machines and the majority of them is subject to be damaged by vibration. The most usual problem of vibration in a turbo-fan is resonance so the case of being composed of iron sheet structure with low strength like a turbo-fan should be taken seriously. In this paper, FFT(Fast Fourier Transform) and Order tracking method were used to analyze factors of vibration in a turbo-fan and hereby with proper selection of vibration isolator, we wanted to reduce vibration of base. After Order tracking, we knew resonance occurred in rotational frequency 23 Hz(1400 rpm) at the casing and the bearing. After the test of base vibration using vibration isolators, the spring isolator was more effective than the robber isolator in the base vibration and the vibration isolating is more effective in the case that the isolating pad is adhered to the bottom of the isolating spring.

  • PDF

Micro-vibration Isolation Performance of X-band Antenna using Blade Gear (블레이드 기어를 적용한 X-밴드 안테나 미소진동 절연성능)

  • Jeon, Su-Hyeon;Kwon, Seong-Cheol;Kim, Tae-Hong;Kim, Yong-Hoon;Oh, Hyun-Ung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.893-899
    • /
    • 2014
  • X-band antenna has been widely used to effectively transmit the high resolution image data from the observation satellite to the ground station. To achieve above mission, X-band antenna is mainly composed of the 2-axis gimbal system using stepping motors and gears. However, the micro-vibration induced by the stepping motor actuation and the imperfect gear teeth alignment during this on-orbit operation is the main source of image quality degradation. In this paper, X-band antenna combined with a blade gear for micro-vibration isolation was suggested and investigated. The structural safety of the blade gear with low rotational stiffness was confirmed by structure analysis based on the derived torque budget. The isolation performance of the X-band antenna with the blade gear was verified through micro-vibration measurement test using the dedicated micro-vibration measurement device proposed in this study.

  • PDF

Derivation of Numerical Equivalent Model of Vibration Isolator using Pseudoelastic SMA Mesh Washer (의탄성 형상기억합금 메쉬 와셔가 적용된 수동형 진동절연기의 수학적 등가모델 도출)

  • Kwon, Sung-Cheol;Jeon, Su-Hyeon;Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.8 no.3
    • /
    • pp.6-13
    • /
    • 2014
  • A passive launch and on-orbit vibration isolator using SMA(Shape Memory Alloy) washer for both the structural safety of the micro-vibration source by attenuating the transmitted force under launch loads and the micro-vibration isolation during their on-orbit operation has been proposed, which does not require the additional launch locking mechanism. To measure the characteristics of SMA mesh washer, we performed compressive loading tests with a single SMA mesh washer and a vibration isolator using SMA mesh washer. The numerical equivalent model of vibration isolator using SMA mesh washer composed of two spring and viscous damping elements has been verified that both stiffness and viscous damping varied with respect to compressed deformations. In addition, the effectiveness of launch loads and micro-vibration reduction has been investigated through the dynamic characteristics measurement test of cooler assembly combined with passive vibration isolator.

A Study on the Characteristics of Vibration Propagation in Seoul Subway Line 2,3 (서울 지하철역사 주변의 진동전파특성에 관한 연구 (2호선 강남역, 교대역, 3호선 교대역))

  • 김석홍;이성춘;김준호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.185-190
    • /
    • 1993
  • 최근 서울에서는 날로 심각해지는 교통난 해소대책으로 현재 운행중인 1-4 호선 외에 5-8호선의 공사가 한창 진행중이다. 이러한 지하철 통과 인접지역 에서는 지하철 운행 진동으로 인하여 상부나 인접 건물에 진동 영향이 우려 되는 경우가 많으며 이에 대한 대책으로 지하철 궤도부를 방진하거나 상부 의 건물을 지하철 구조체로부터 진동 절연하는 방법이 검토되고 있다. 이러 한 대책 수립시에는 대책후의 진동예측이 필요하며 지하철의 진동특성 입력 데이타 확보가 필수적이다. 본 연구에서는 이러한 필요성에 따라 서울의 2호 선 강남역과 교대역, 3호선 교대역 궤도부 주변 바닥과 벽체, 플랫폼, 표파는 층의 바닥에서 지하철 통과시의 전후, 좌우, 상하방향의 진동을 측정 분석하 여 추후 지하철 진동저감대책 수립에 기초자료로 제시하고자 한다.

  • PDF

Analysis of Isolation System for Impulsive Force Device with Recoil Mechanism (반동방식 충격기구의 완충시스템 해석)

  • Kim, HyoJun;Ryu, BongJo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.3 s.96
    • /
    • pp.272-279
    • /
    • 2005
  • In this study the optimal isolation system for the prototype HIFD(high impulsive force device) is investigated. For this purpose, firstly, the dynamic behavior of a human body and a transmitted force under specific operation conditions are analyzed through a series of experimental works using the devised test setup. In order to design the optimal dynamic absorbing system, the parameter optimization process is performed using the simplified isolation system model based on the experimental results of linear impulse and transmitted force. Finally, under the parameters satisfying the constraints of the buffering displacement and the transmitted force, the performance of the designed isolation system for the prototype HIFD is evaluated by experiment.