• Title/Summary/Keyword: 진동전달율

Search Result 57, Processing Time 0.025 seconds

A Comparison of Vibration Isolation Characteristics of Various Forms of Passive Vibration Isolator (다양한 수동 진동 절연 장치의 진동 절연 특성 비교)

  • Lee, Dae-Oen;Han, Jae-Hung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.232-237
    • /
    • 2012
  • Transmission of unwanted vibration to sensitive systems can cause various problems including performance degradation and system malfunction. The most common approach to limit the transmission of harmful vibration disturbances to the sensitive system is adapting passive vibration isolator. The classical passive vibration isolator comprising a viscous damper and spring element in parallel, however, exhibits conflicting performance characteristics in that low amplification at the resonance, which is desirable, can only be achieved at the sacrifice of vibration isolation performance in high frequency region, which is undesirable. In this paper, vibration isolation characteristics of various passive isolator schemes in literature to circumvent this conflict are introduced and compared.

  • PDF

Experimental Study on Effect of Boiling Heat Transfer by Ultrasonic Vibration (초음파 진동이 비등열전달 과정에 미치는 영향에 관한 실험적 연구)

  • Na Gee-Dae;Oh Yool-Kwon;Yang Ho-Dong
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.35-44
    • /
    • 2006
  • This study experimentally investigates effect of boiling heat transfer when ultrasonic vibration was applied. Under the wall temperature condition, temperature distribution in a cavity was measured during the boiling process and heat transfer coefficient of convection, sub-tooled boiling and saturated boiling states were measured with and without ultrasonic vibration, respectively. Also, the profiles of the pressure distribution in acoustic field measured by a hydrophone were compared with the augmentation ratios of heat transfer calculated by local heat transfer coefficient. Result of this study, heat transfer coefficient and augmentation ratio of heat transfer is higher with ultrasonic waves than without one. Especially, augmentation ratio of heat transfer is more increased the convection state than sub-cooled boiling and saturated boiling states. Acoustic pressure is relatively higher near ultrasonic transducer than other points where is no installed it and affects the augmentation ratio of heat transfer.

Effect of nonuniform perforation in the concentric resonator on the transmission loss and back pressure (동심관형 공명기 내부의 천공 요소의 불규칙한 배열이 전달손실 및 배압에 미치는 특성 연구)

  • ;Antoine Delaigue
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.515-519
    • /
    • 2002
  • 자동차 및 유체기계의 흡기계나 배기계에 사용되는 소음기의 음향성능은 전달손실로 기계성능은 배압으로 표현된다. 유체가 흐르는 관 사이의 임피던스 부정합을 이용하는 반사형 소음기의 경우, 내부 유로에 천공을 주어 음향감쇠를 시키거나 유동을 안정시키는 경우가 많다. 본 연구에서는 동심관형 공명기의 내부 관에 존재하는 천공의 분포 양상이 소음기의 전달손실과 배압에 미치는 영향을 실험을 통하여 고찰하였다. 내부관의 평균 천공율은 일정하지만 길이 방향을 따라서 천공율이 변하는 다섯가지의 공명기에 대한 실험을 수행하고, 성능에 미치는 영향을 살펴보았다. 전달손실은 천공요소의 임피던스 모델을 고려하여 예측한 결과와 비교하였고, 측정된 배압은 모의 해석 결과와 비교하였다. 분석 결과, 천공율이 점점 작아지는 분포나, 작았다가 커진후 다시 작아지는 형태의 분포를 가질 경우, 배압 측면에서 매우 유리하고, 음향 전달손실도 큰 차이가 없음을 밝혔다.

  • PDF

Transmissibility Effect Evaluation of Buildings Near Railroad Areas (철도인접지역 건물에 대한 진동전달율의 영향성 평가)

  • Kim, Ji-Hyeon;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.1
    • /
    • pp.131-138
    • /
    • 2011
  • For train vibration influence assessment of newly constructed buildings in building design levels, 4 train measured vibration acceleration responses were used to compare with TR theory values and suitability of TR values was proposed. Through this TR method, construction planned grounds located near railroad areas were selected and ground vibration measurement was conducted. Through natural frequency by MIDAS, vertical acceleration response, and ground frequency from measured vibration response, TR was calculated and vibration prediction was conducted. As a result of comparing acceleration response estimate applying TR and measured value of train vibration acceleration response, it was found that it was in 3.61%~37.1% of margin of error. Clear peak of 7.19~10.61Hz in KTX, Gyungeuisun, and cement train were confirmed.

A Study on the Minimization of Transmissibility of Seat Foam in Passenger Vehicles (승용차 시트용 폼의 진동전달율 최소화에 관한 연구)

  • 류운영;박명혁
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.4
    • /
    • pp.110-120
    • /
    • 1997
  • One of the most important factor for the comfort of the passenger vehicles is the minimization of the compressible transmissibility during the running vehicles. Seat foam materials of I2 series(index 95 and the contents of isocyanate TDI was changed in percentages 75, 70, 65, 60, 50, 40) and DI series(density 50kg/$\textrm{m}^3$, index was changed 100, 95, 90) showed the significant differences in their transmissibility depended upon their chemical constitution such as index and contents of isocyanate TDI. The minimum trasmissibility of seat foam materials of I2 series was found from the materials with the contents of 65% isocyanate TDI and the index 95 at the frequency 4.79~5.31Hz. Also the minimum transmissibility of seat foam materials of DI series was found from the materials with the index 90 and the density of 50kg/$\textrm{m}^3$ at the frequency of 4.79~5.31Hz.

  • PDF

Contribution analysis using transmissibility of a vibration path (진동 전달율에 기반한 기여도 분석 방법)

  • Kim, C.J.;Bae, C.Y.;Lee, D.W.;Lee, B.H.;Kim, H.C.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.602-603
    • /
    • 2008
  • The design modification of problematic component in a given vibration path is disallowed in order to sacrifice other performances such as ride comport or handling of a vehicle. For this, the paper presents a new contribution analysis based on transmissibility ratio (TR) of acceleration in a definite vibration path to find a proper candidate for design modification. The new contribution analysis is based on the fact that the sensitivity of TR over a small design change is inversely proportional to the magnitude of TR. The new methodology can significantly relieve efforts of time-consumming modal analysis for detail modal information. The theory of proposed contribution analysis is simulated with five-degree-of-freedom open vibration path and confirms that the contribution result is well matched with the variance of TR over a dynamic change on a vibration path.

  • PDF

Effects of a Submerged Block on the Sloshing of a Fluid in Rectangular Tanks (수중블럭이 사각형탱크의 자유수면 유동에 미치는 영향)

  • Choun, Young-Sun;Yun, Chung-Bang
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1994.10a
    • /
    • pp.191-200
    • /
    • 1994
  • 사각형 유체저장탱크의 바닥에 놓여져 있는 사각형 블럭의 크기 및 위치가 자유수면의 유동진동수와 모드형상에 미치는 영향에 대하여 선형파이론을 적용하여 검토하였다. 유체의 영역을 3부분으로 나누고 각 영역에서의 속도포텐셜을 입사파와 블럭으로 인해 발생되는 반사파 및 전달파의 항으로써 표현하였다. 그리고 블럭에 의한 파의 반사율과 전달율은 유체영역의 경계에서 속도포텐셜과 유체입자의 속도가 연속인 조건을 사용하여 구하였다. 연구결과 블럭의 높이와 폭은 자유수면의 고유진동수에 크게 영향을 미치며 높이와 위치는 모드형상에 주로 영향을 준다. 블럭이 높고 폭이 넓을수록 고유 진동수는 감소하며 블럭이 높고 탱크의 벽면으로 이동할수록 모드형상은 크게 변한다.

  • PDF

Measurement of Acoustic transfer function by one microphone (한개의 마이크로폰에 의한 음향 전달함수 측정)

  • 정갑철;임정빈;권영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.04a
    • /
    • pp.201-205
    • /
    • 1994
  • 본 실험에서는 한개의 마이크로폰만을 이용하여 소음기내에 삽입된 재료의 흡음율을 임피던스관에서 전달함수기법으로 측정하고 측정값의 정확성을 확인하기 위하여 정재파법으로 측정한 결과와 비교하여 보았다. 또한 이 측정법을 단순팽창형 소음기에 적용하여 소음기의 투과손실을 측정한 후, 이론과 비교하여 측정의 정확성을 검토하였고 소음기내에서의 흡음재의 위치에 따른 투과손실의 변화에 대해서도 이론과 비교 검토하였다.

  • PDF

Estimation of the Measurement Uncertainty in Measuring the Vibration Transmissibility of Anti-vibration Gloves (방진장갑 진동 전달률 측정에서의 측정불확도 추정)

  • Hong, Seok-In;Jang, Han-Ki;Choi, Seok-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.251-254
    • /
    • 2005
  • In this study vibration transmissibilities of the selected anti-vibration gloves were measured, and the measurement uncertainty was estimated. Since human factors such as palm size, gripping condition and dynamic properties of the hand-arm effect the measurement a lot, it is necessary to know ow much the uncertainty is. This study takes the measurement procedure suggested in ISO 10819. Three subjects Joined at each test and each anti-vibration glove was tested twice per a subject. Average and standard deviation of vibration transmissibility were calculated and uncertainty of them were estimated at 95% confidence level.

  • PDF