• Title/Summary/Keyword: 진동시간 제어

Search Result 195, Processing Time 0.023 seconds

A Suppression of Residual Vibration on the Flexible Structures by Input Shaping (입력설계기법에 의한 유연구조물의 잔류진동제어)

  • Park, Myoungho;Han, Myoungseok;Park, Sungjong
    • 대한공업교육학회지
    • /
    • v.31 no.2
    • /
    • pp.364-380
    • /
    • 2006
  • This paper presents a procedure for designing command to maneuver flexible structure with very little residual vibration, even in the presence of modeling errors. For the open loop maneuver, the various shaped profiles using multiple step inputs delayed in time are considered for robustness and compared with the responses of rigid body and flexible body in virtue of simulations and experiments. Input shaping generates vibration-reducing shaped commands through convolution of an impulse sequence with the desired command. A flexible model with a cylindrical hub and four symmetric appendages is considered to examine the responses to real plant, and to illustrate the effectiveness of the proposed shapers. The appendages are long and flexible, leading to low frequency vibration under any control action. It is shown by a series of simulation that a properly designed feedback controller with input shaper performs well, as compared with open loop controller with input shaper. The control objective is to achieve a fast settling time of residual vibration to flexible structure and robustness (insensitivity)to plant uncertainty, to eliminate residual vibration.

A Study on the Micro-Vibration Control of a Precision Equipment(HDD CELL Vibration Control) (정밀장비의 미진동제어 기술에 관한 연구(HDD CELL 진동제어))

  • Lee, Hong-Ki;Park, Hae-Dong;Choi, Hyun;Bae, Kee-Sun;Kim, Doo-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.233-239
    • /
    • 1995
  • 정밀장비의 내진 및 방진설계에 대한 일반적인 procedure를 제시하고 이를 정밀제어 장비인 HDD CELL에 적용하였다. 정밀장비의 내진 설계를 위해서 는 정확한 진동 허용규제치와 정밀장비가 설치되는 구조물의 진동 환경에 대한 데이터를 확보하는 것이 우선적으로 해야할 일이다. 구조물의 진동은 직접 측정을 하거나 설계 자료를 이용하는 것이 가능하지만 진동 허용규제치는 장비 제작사에서 진동환경시험을 통하여 얻어진 자료를 사용 자에게 제시하는 것이 일반적인 과정이다. 그러나 고도의 정밀성을 요하는 장비 전체를 가진 테이블에 설치하여 진동환경시험을 수행하는 일은 시간과 경제적인 측면에서 유익하지 못하다. 그러한 면에서 본 논문에 제시한 진동 허용가진력 규제치를 이용한 정밀장비의 내진 및 방진의 정량적인 설계뿐만 아니라 진동 허용규제치를 손쉽게 구할 수 있다는 점에서 유익하다 하겠다.

  • PDF

Vibration Pattern Editor and Controller for Sound-driven Vibration System (사운드 기반 진동 시스템을 위한 진동 패턴 에디터와 컨트롤러)

  • Oh, Sung-Jin;Cho, Dong-Hyun;You, Yong-Hee;Sung, Mee-Young;Jun, Kyung-Koo
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.564-568
    • /
    • 2008
  • In this paper, we develop a vibration pattern editor and a vibration pad controller for a sound-driven vibration system, which can generate diverse vibration effects in realtime by analyzing signals from the sound output of PC. It consists of a DSP system to analyze the sound, a wrist-wearable vibration pad, and its controller. For the vibration pattern editor, we define four elements to describe the pattern the locations of vibrating elements, start time, duration, and vibration intensity. The editor provides a GUI through which users can create such patterns fast and easily, and store them for reuse. We also propose a pattern-interpreting controller. It is able to interpret patterns created by the editor and control the pad accordingly. It can avoid the need to change the controller firmware whenever desired patterns change.

  • PDF

Vibration Control of Flexible Structures Using Controllable ER Mounts : Experimental Investigation (제어 가능한 ER 마운트를 이용한 유연 구조물의 진동제어 : 실험적 고찰)

  • Choi, Seung-Bok;Sohn, Jung-Woo;Han, Young-Min
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.4
    • /
    • pp.400-408
    • /
    • 2009
  • This work presents experimental results on vibration control of flexible structures using the squeeze mode electrorheological(ER) mount. An appropriate size of the squeeze mode ER mount is devised and its field-dependent damping force characteristics are experimentally evaluated. The ER mount is then applied to two different flexible structures : beam structure and frame structure. An optimal controller associated with displacement and acceleration signals is designed to suppress the imposed vibration and experimentally realized using the microprocessor. Vibration control responses of the flexible structures such as acceleration are evaluated in time and frequency domains.

Active Vibration Control Using Piezostack Based Mount (압전작동기 마운트를 이용한 능동진동제어)

  • Nguyen, Vien-Quoc;Choi, Sang-Min;Paeng, Yong-Seok;Han, Young-Min;Choi, Seung-Bok;Moon, Seok-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.4
    • /
    • pp.386-392
    • /
    • 2008
  • This paper presents active vibration control performance of a hybrid mount. The proposed hybrid mount is devised by adopting both piezostack as an active actuator and rubber as a passive element. After experimentally identifying actuating force characteristics of the piezostack and dynamic characteristics of the rubber, the hybrid mount was designed and manufactured. Subsequently, a vibration control system with a specific mass loading is constructed, and its governing equations of motion are derived. In order to actively attenuate vibration transmitted from the base, a feedforward controller is formulated and experimentally realized. Vibration control responses are then evaluated in time and frequency domains.

Computer simulation for the machinery diagnosis by using the bispectrum (바이스펙트럼 해석의 설비진단을 위한 컴퓨터 시뮬레이션)

  • 오재응;정준회;염성하
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.128-133
    • /
    • 1986
  • 설비진단에 응용되는 신호처리의 기법으로는 파워스펙트럼, 바이스펙트럼, 켑스트럼 등이 사용되었다. 파워스펙트럼은 이론적인 면과 계산과정 그리고 신호처리에서의 적용방법등이 잘 알려져서 성공적으로 사용되어져 왔다. 특히 음향분야에서는 여러가지 응용기술이 개발되어 실제계에 적용되고 있으며 계측장비도 파워스펙트럼 해석법에 알맞게 개발되어져 왔다. 파워스펙트럼해석법을 사용하여 진동계를 구성하는 각 요소들의 고유진동수와 진동계 전체를 나타내는 진동파들의 주파수성분 간의 관계에 의하여 진동의 원인 및 소음원 등을 추정하는 것이 가능하다. 그러나 파워스펙트럼은 일반적으로 정상적인 신호를 갖는 진동계에 대한 해석 일 때는 그 이론과 실제가 잘 일치하지만, 진동계 자체가 항시 임의의 주파수를 갖고서 움직일 때 그 해석에는 다음과 같은 문제점이 생긴다. 첫째, 불규칙한 진동계에서는 규칙적인 진동계보다 잡음의 영향을 많이 받기 때문에 실제로 잡음이 진동계의 고유주파수 부근에 있을 경우에는 파워스펙트럼해석으로는 불가능한 경우가 있다. 둘째, 진동파 중에 포함되어 있는 위상이라는 중요한 정보가 없다. 셋째, 시간지연에 따른 진동계의 정확한 정보를 얻을 수 없다. 이상에서 볼 때 파워스펙트럼해석법은 한계가 있음을 알 수 있다. 따라서 본 논문은 바이스펙트럼이라는 해석법을 사용하여 정상과정에서 비정상과정으로 시간지연에따라 변하는 진동계 또는 정상적인 진동계의 저주파에서의 상호간섭 정도 및 위상관계를 관찰함으로써 파워스펙트럼과 비교하여 바이스펙트럼해석법의 타당성을 검토한다. 바이스펙트럼의 실제적인 계산방법은 P. J. Huber가 세가지 접근 방법을 제안했는데 시간영역에서의 평균화를 행하여 계산하는 법, 연속된 기록들을 평균화하는 것, 주파수 영역에서의 평균화를 행하는 것 등이 있다. 본 논문에서는 FFT를 먼저 행하고 파워스펙트럼과 바이스펙트럼 및 바이코히어런스를 구하였다. 그러나 바이스펙트럼해석법은 수치해석적인 면에서 볼 때 파워스펙트럼해석법에 비하여 미약한 점이 많고 통계학적인 그 의미가 확실하게 알려져 있지 않기 때문에 본 논문에서는 시뮬레이션을 통하여 그 물리적 의미를 규명하고져 한다.

  • PDF

Performance Enhancement of Pneumatic Vibration Isolator in Low Frequency by Time Delay Control (시간지연 제어기법을 이용한 공압 제진대의 저주파 영역에서의 진동 절연 성능 향상)

  • Oh, Ki-Yong;Shin, Yun-Ho;Lee, Jeung-Hoon;Kim, Kwang-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.11 s.116
    • /
    • pp.1100-1107
    • /
    • 2006
  • As environmental vibration requirements on precision equipment become more stringent, use of pneumatic isolators has become more popular and their performance is subsequently required to be further improved. Performance of passive pneumatic isolators is related to various design parameters in a complicated manner and, hence, is very limited especially in low frequency range by chamber volume. In this study, transmissibility behavior of the pneumatic isolators depending on frequency and dynamic amplitude are presented. Then, an active control technique, time delay control, which is adequate for a low frequency nonlinear system, is applied. A procedure of applying the time delay control law to a pneumatic isolator is presented and it's effectiveness in the transmissibility performance is shown. Comparison between passive and active pneumatic isolators is made based on simulation.

Performance Enhancement of Pneumatic Vibration Isolator in Low Frequency by Time Delay Control (시간지연 제어기법을 이용한 공압 제진대의 저주파 영역에서의 진동 절연 성능 향상)

  • Oh, Ki-Yong;Shin, Yun-Ho;Lee, Jeung-Hoon;Kim, Kwang-Joon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.837-843
    • /
    • 2006
  • As environmental vibration requirements on precision equipment become more stringent, use of pneumatic isolators has become more popular and their performance is subsequently required to be further improved. Performance of passive pneumatic isolators is related to various design parameters in a complicated manner and, hence, is very limited especially in low frequency range by chamber volume. In this study, transmissibility behavior of the pneumatic isolators depending on frequency and dynamic amplitude are presented. Then, an active control technique, time delay control, which is adequate for a low frequency nonlinear system, is applied. A procedure of applying the time delay control law to a pneumatic isolator is presented and it's effectiveness in the transmissibility performance is shown. Comparison between passive and active pneumatic isolators is made based on simulation.

  • PDF

Control Effect of Isolator on the Pump Induced Vibration in Office Building (사무실 건물에서의 펌프진동에 따른 방진장치의 제어효과)

  • 노병철
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.1-12
    • /
    • 2000
  • 펌프는 다르 진동 유발원들과는 달리 일정한 주파수 및 크기를 갖는 진동을 일으키므로 스프링이나 댐퍼와 같은 간단한 방진기기를 이용하여 진동을 제어할 수 있다 현재 국내에서는 대부분의 펌프에 이러한 방진장치를 설치하는 것이 일반화되어있다 그러나 펌프의 용량 및 중량 주변 구조물의 형태 및 크기 등에 따라서 방진기구의 채택이 불필요한 경우도 있으므로 설비 진동기초에 대한 획일적인 설계와 시공개념은 불필요한 인적, 시간적 및 경제적인 낭비를 초래할 수 있다. 따라서 본 연구에서는 사무용 건무에 사용되는 각종 펌프류에 대하여 가진특성과 구조물의 진동가속도응답을 측정하는 진동실험 및 이론적 해석을 실시하고 본래 계와 수정된 계의 진동을 답과 허용진동수준을 비교.분석함으로서 방진장치의 설치가 불필요한 펌프용량을 제시하였다.

  • PDF