• Title/Summary/Keyword: 진동성능시험

Search Result 384, Processing Time 0.029 seconds

Development and Application of Test Apparatus for Classification of Sealed Source (밀봉선원의 성능시험을 위한 장치 개발 및 적용)

  • Kim, Dong-Hak;Seo, Ki-Seog;Bang, Kyoung-Sik;Lee, Ju-Chan;Son, Kwang-Je
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.35-44
    • /
    • 2007
  • Sealed sources have to conducted the tests be done according to the classification requirements for their typical usages in accordance with the relevant domestic notice standard and ISO 2919. After each test, the source shall be examined visually for loss of integrity and pass an appropriate leakage test. Tests to class a sealed source are temperature, external pressure, impact, vibration and puncture test. The environmental test conditions for tests with class numbers are arranged in increasing order of severity. In this study, the apparatus of tests, except the vibration test, were developed and applied to three kinds of sealed source. The conditions of the tests to class a sealed source were stated and the difference between the domestic notice standard and ISO 2919 were considered. And apparatus of the tests were made. Using developed apparatus we conducted the tests for $^{192}Ir$ brachytherapy sealed source and two kinds of sealed source for industrial radiography. $^{192}Ir$ brachytherapy sealed source is classified by temperature class 5, external pressure class 3, impact class 2 and vibration and puncture class 1. Two kinds of sealed source for industrial radiography are classified by temperature class 4, external pressure class 2, impact and puncture class 5 and vibration class 1. After the tests, Liquid nitrogen bubble test and vacuum bubble test were done to evaluate the safety of the sealed sources.

A Study on Method of Evaluation for Deck Pavement (교면포장의 평가 방법 고찰)

  • Jo, Shin Haeng;Jo, Nam June;Jang, Jung Soon;Baek, Yu Jin;Kim, Nak Seok
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.86-86
    • /
    • 2011
  • 토목 기술의 발달로 장대교량이 증가함에 따라 교면 포장도 더 심각한 진동 및 충격, 기상조건에 노출되게 된다. 교면 포장은 차량의 주행의 편리성뿐 아니라 교량 구조물을 보호해야 하는 역할도 함께 수행하기 때문에 일반 토공부의 포장과 다른 성능을 필요로 한다. 교면 포장의 특수함을 감안하여 교면 포장의 품질을 평가하고, 설계와 적용시 반영 한다면 교량의 내구 연한 및 시공, 유지관리 비용을 절감 할 수 있을 것이다. 본 논문에서는 교면 포장에 요구되는 성능을 조사하고, 교면 포장 특히, 장대 교량 적용시 교면 포장의 성능 평가를 위한 평가 방법을 고찰하였다. 교면 포장의 가장 큰 구조적 특징은 교량의 진동과 휨에 의해 포장이 받게 되는 휨응력이다. 특히 교량의 장경간화에 따라 더 큰 진동과 변형을 경험하게 되는 교면 포장은 그에 따른 충분한 휨 추종성과 피로 저항성을 확보하여야 한다. 기존 토공부 포장에서는 실험이 간단한 원통형 공시체를 이용한 간접인장강도 모드의 실험으로 피로 성능을 평가하였으나, 교면 포장은 실제 거동 특성과 유사한 빔 피로 시험 모드가 보다 신뢰성이 높을 것으로 판단된다. 빔 피로시험 모드로는 3점, 4점, 5점 휨 피로 시험 모드가 있으며, 각각의 모드는 지지점의 개수, 재하점의 개수에 따라 다른 거동 특성을 평가 할 수 있다. 최근 개발된 5점 휨 시험의 경우 교량에서 발생하는 부(-)모멘트를 모사할 수 있어 보다 현실적인 검증이 가능할 것으로 예상된다. 이 외에도 실제 크기 모형을 이용하여 윤하중을 가하는 Full-scale 모델의 경우 비용과 시간이 많이 소요되는 단점이 있으나 가장 신뢰성이 높은 방법이라고 할 수 있다. 교면 포장은 교량구조부로 수분이 침투되는 것을 막아주는 역할을 하여야 하며, 특히 해상 교량의 경우의 염분과 겨울철 사용되는 제빙화학제는 콘크리트의 열화와 강구조물의 부식을 발생시키므로 교면 포장의 방수 성능 검토는 매우 중요한 역할을 한다. 일반 토공부 포장과 달리 교면 포장은 하부층이 대기에 노출되어 있기 때문에 겨울철에 더 낮은 온도로 포장체의 온도가 내려가게 되고, 온도가 떨어진 포장층은 스티프니스가 증감함에 따라 저온 균열의 발생확율이 높아지며, 휨추종성도 나빠질 가능성이 높다. 따라서 저온에서의 균열 저항성 및 스티프니스를 평가하는 것은 교면 포장 재료의 중요한 인자 중 하나이다. 포장과 포장 하부층의 접착은 포장층의 일체화된 거동을 할 수 있게 하기 때문에 내구성 향상에 중요하다. 특히 교량과 같이 진동과 변형이 많은 경우에 있어 포장 접착층의 성능은 포장과 교량 구조물의 파손에 더 큰 영향을 미치게 된다. 접착성능은 실내에서의 직접인장모드와 전단접착강도 시험 모드의 실험이 있으며, 현장에서 측정하는 Pull-off 실험 등이 있다. 최근에 교통량과 중차량의 증가와 더불어 교량이 장경간화 되어 가면서 평가방법과 기준을 과거보다 엄격하게 할 필요성이 있다. 하지만 현실은 교면포장에 대한 시방규정이 모호하기 때문에 본 논문에서 제시한 국내외의 다양한 평가방법을 통해 적절한 교면포장의 성능을 평가하고 교면포장의 거동특성에 대한 이해를 함으로써 보다 발전된 교량기술을 확보할 수 있을 것이다.

  • PDF

A study on the transmission loss of floor part in the train (습식 철도차량 바닥구조의 차음성능 연구)

  • 이근희;조태승;정인호;이용주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.753-758
    • /
    • 1998
  • 이 글에서 살펴본 바의 내용에 의하면 철도차량 습식 바닥구조의 차음성능은 기존의 35 mm를 47 mm로 하는 경우 약 4dB 정도의 차음개선 효과를 기대할 수 있으며, 제진층을 추가로 도입하는 경우 1~2dB의 추가적인 차음개선을 기대할 수 있다고 결론된다. 바닥충격음에 대한 차단성능은 경량충격음의 경우 두께 증가 및 제진층 적용에 의하여 각각 3dB 및 7dB의 차음개선이 예상된다. 그러나 중량충격음의 경우에는 차음개선 효과가 거의 없으며 오히려 감소하는 경우도 있으므로 보다 구체적인 검토 연구의 필요성이 있다.산업계에서는 현재의 진동소음저감기술을 좀더 단시간에 차량개발 프로그램에 적용하는데 더욱 큰 노력을 할 필요가 있을 것이다. 따라서 여기에서는 현재 자동차업체에서 수행하는 진동, 소음및 충격시험평가에 대해서만 국한하여 기술하고자한다.urce)을 찾아 직접 그 원인을 차단 및 치유하는 적극적이고 공격적인 방법을 이용하고있다. 본 글에서는 이러한 진동소음 문제를 차량의 개발 단계에서 해결하기 위한 일련의 과정 및 여러가지 개선기법에 대해서 살펴보고 그를 통한 진동소음 문제 해결방법을 제시하고자 한다.

  • PDF

A Study on Flow and Vibration Analysis, and Performance Test for Automotive Fuel Pump (자동차 연료펌프의 유동 및 진동 해석과 성능시험에 관한 연구)

  • Son, Jae-Hwan;Bae, Jung-Sub;Kim, Young-Suk;Han, Chang-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1496-1502
    • /
    • 2012
  • The fuel pump mounted on the engine in the vehicle is consist of the outer and inter rotors, and which inhales fuel from the inlet port and supplies it to the outlet port. In this study, it is carried out the analysis and test of the fuel pump with rotors to evaluate its performance. It is analyzed the flow characteristics of the fuel pumps with numerical simulation in their inlet-outlet angles of 0, 15, 30 degree. After it is determined whether it has the best flow characteristics, its vibration characteristics is analyzed. The flow rate of a pump in the inlet-outlet angles of 0 degree is 191.0 LPH(Liter per hour) which is the largest. and its vibration is calculated to be 0.866 $^m/s^2$. In the results of vibration test, it is known that the vibration of the research pump is smaller than that of the existing one. And the natural frequencies of two pumps is nearly same. Therefore it is known that the performance of the research pump is superior.

Centrifuge-Shaking Table Test for Seismic Performance Evaluation of Subway Station (지하역사의 내진성능평가를 위한 원심모형 진동대 시험)

  • Kim, Jin Ho;Shin, Min Jung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.3
    • /
    • pp.99-105
    • /
    • 2011
  • When a certain magnitude earthquake occurs, serious damage for human and properties is a major concern for most of the subway stations which were not applied for earthquake resistant design. Consideration and experimental verification for ground and structural behavior based on soil-structure interaction relation are required to evaluate seismic performance of the subway station as embedded structures. For 1/60 scaled subway station model, centrifuge modeling shaking table test is performed using Kobe and Northridge earthquakes. Compare to displacements and moments of the underground and structure obtained by soil response analysis and response displacement method based on experimental results, this paper shows how to evaluate seismic performance of subway station.

A Correlation between the Pressure Oscillation of Combustion Chamber and Thrust Response in a 70 N-class Hydrazine Thruster (70 N급 하이드라진 추력기의 연소실 압력진동 강도와 추력 응답특성의 상관관계)

  • Jung, Hun;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.3
    • /
    • pp.1-8
    • /
    • 2015
  • A ground hot-firing test(HFT) was accomplished to draw a correlation between the pressure oscillation intensity of combustion chamber and thrust response characteristics in a 70 N-class hydrazine thruster which has been developed recently. Monopropellant grade hydrazine was adopted as a propellant for the HFT, and combustion-chamber characteristic length, propellant injection pressure were applied as test parameters. It was confirmed that the decrease of thrust-chamber diameter and injection pressure augmented the pressure oscillation of stagnation chamber in the test condition specified, and the oscillation hampered the pulse response performance of test models.

A Study on the Determination of Vibration Criteria for Vibration Sensitive Equipments Using Impact Test (충격시험을 이용한 고정밀장비의 진동허용규제치 결정기법에 관한 연구)

  • 이홍기;박해동;김두훈;김사수
    • Journal of KSNVE
    • /
    • v.7 no.2
    • /
    • pp.247-254
    • /
    • 1997
  • In the case of a precision equipment, it requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga class semiconductor wafers. This high technology equipments require very strict environmental vibration standard in proportion to the accuracy of the manufacturing, inspecting devices. The vibration criteria are usually obtained either by the real vibration exciting test on the equipment or by the analytical calculation. This paper proposes a new method to solve this problem at a time. The permissible vibration level to a precision equipment can be easily obtained by analyzing a process of Frequency Response Function. This paper also demonstrates its effectiveness by applying the proposed method to finding the vibration criteria of a Computer Hard Disk Driver by Impact Test.

  • PDF

Application of Tuned Mass Damper to Suppress Man-Induced Vibrations of Cable Stayed Foot-bridge (사장교형식 보도교의 보행진동제어를 위한 TMD 적용)

  • Kim, Yun-Seok;Lee, Seung-Woo;Kim, Jae-Min;Chang, Seong-Kyu
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.74-74
    • /
    • 2011
  • 본 연구에서는 중앙경간 54m, 교폭 4m의 사장교형식의 보도교로 측경간은 계단으로 이루어진 1경간 케이블교량을 대상으로 보행하중에 의한 수직진동을 제어하기 위해 제진장치(TMD)를 적용하기로 하고 실물 TMD의 설계 및 제작 그리고 설치 및 제어성능실험을 수행하였다. 우선 사장교형식의 교량. 그리고 1경간 교량이라는 점에서 상대적으로 감쇠율이 낮을 것으로 예측되었고 또한 54m의 경간장이 보행자가 가진 주파수에 근접한 고유진동수를 나타낼 것으로 사료되어 Eurocode 2 part 2(EC5-2)의 규준에 따라 1인 및 다수 보행하중에 의한 보도교의 발생가속도를 산출하였다. 이 경우 최대가속도는 다수의 보행자가 연속적으로 진행할 때 발생하였으며, 수직방향의 가속도가 사용성기준을 초과하는 것으로 나타났다. 또한 구조해석프로그램에 의한 고유치 해석결과, 보행하중의 주파수대역내에 진동모드가 존재하는 것으로 나타났다. 따라서 본 교량의 설계단계에 있어서 보행진동을 제어하기 위하여 유지관리가 용이한 수동형의 동조질량감쇠장치(Tuned Mass Damper)를 적용하기로 하였으며 TMD의 설계에서는 TMD의 제어목표를 만족시킬 수 있는 TMD의 가동질량(moving mass)을 우선적으로 결정하였고, 이로부터 Den Hartog의 제안식에 따라 TMD의 고유진동수비, 유효감쇠비를 산정하였다. 산정된 변수들을 이용하여 설계된 TMD는 현장설치 및 튜닝의 편의성을 고려하여 수평 외팔보형식으로 설계, 제작되었으며 제작된 TMD의 경우 회전축에 대해 질량, 스프링, 댐퍼의 중심거리를 조정함으로써 TMD의 진동수, 강성, 감쇠력을 상대적으로 매우 용이하게 조절할 수 있으며, 조정범위 또한 광범위하여 일반 TMD에 비해 현장설치시 대상구조물에 동조시키기가 용이하며, 작동시 마찰감쇠가 거의 없다는 장점이 있다. 현장설치전에 제작된 TMD를 대상으로 자유진동 시험을 통하여 질량의 중심거리, 스프링 크기 그리고 댐퍼의 설치유무를 각각 변화시키며 TMD의 자유진동 데이터를 취득하였다. 각각의 시험에서 얻어진 데이터로부터 스펙트럼해석을 통하여 고유진동수를 구하였고, 자유진동 파형으로 부터 감쇠비를 구하였다. TMD는 일반적으로 제어모드의 변형형상이 가장 큰 곳에 설치되었을 때 최대의 제진효과를 발휘할 수 있다. 그러나 현장여건상 설치가 불가능하거나 미관을 해치는 경우에는 가능한 범위 내에서 TMD 제어효율이 가장 크게 발휘할 수 있는 곳을 선택하여야 한다. 본 보도교의 경우, 중앙경간 중심부에서 가장 큰 모드변형형상을 나타내지만, 보도교의 상판 연결부 등에 따른 TMD 시공문제로 인하여 TMD 설치위치는 교량 중앙에서 양 방향으로 1.25m 떨어진 곳에 대칭으로 총 2기를 설치하기로 하였다. 일반적으로 TMD의 모든 설계변수는 구조물의 설계단계에서 수행된 구조해석결과에 근거하여 설정하므로 완공된 구조물, 즉 실제보도교의 동적특성을 계측하여 정확하게 진동수를 튜닝하여야 한다. 구조해석에 의한 보도교의 수직방향(TMD 작동방향) 고유진동수는 1.5225 Hz이며, 감쇠비는 규준에 의하여 0.6 %로 가정하였다. 그러나 이 값들은 구조해석모델 및 재료적 특성과 시공상의 오차에 의하여 실제와 다를 수 있으므로 현장계측에 의한 확인이 요구된다. 또한 TMD의 제진효율이 설계시의 목표대로 확보되었는지도 확인해야 하므로 현장튜닝 및 성능시험을 실시하였다. 보도교의 가진은 사전에 실시한 상시 미진동계측결과를 토대로 2Hz를 목표로 하여 인력가진실험을 수행하였고, 탁월진동 주파수는 1.9896Hz로 나타나 구조해석결과와 오차가 있음을 알 수 있다. 가진실험결과를 토대로 TMD의 진동수를 최적진동수비로 튜닝하고 인력가진 실험을 다시 실시하여 TMD의 진동제어성능을 검토하였다. TMD 튜닝 전, 후의 보도교 감쇠비를 비교한 결과, TMD를 설치함으로써 약 4.218%의 감쇠비 증가가 있음을 알 수 있다.

  • PDF