Centrifuge-Shaking Table Test for Seismic Performance Evaluation of Subway Station  

Kim, Jin Ho (한국철도기술연구원 도시철도표준화연구단)
Shin, Min Jung (과학기술연합대학원대학교 미래첨단교통시스템공학)
Publication Information
Journal of the Korea institute for structural maintenance and inspection / v.15, no.3, 2011 , pp. 99-105 More about this Journal
Abstract
When a certain magnitude earthquake occurs, serious damage for human and properties is a major concern for most of the subway stations which were not applied for earthquake resistant design. Consideration and experimental verification for ground and structural behavior based on soil-structure interaction relation are required to evaluate seismic performance of the subway station as embedded structures. For 1/60 scaled subway station model, centrifuge modeling shaking table test is performed using Kobe and Northridge earthquakes. Compare to displacements and moments of the underground and structure obtained by soil response analysis and response displacement method based on experimental results, this paper shows how to evaluate seismic performance of subway station.
Keywords
Subway station; Centrifuge test; Seismic performance evaluation; Soil-structure interaction; Response displacement method;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Lo Presti, D. C. F., Berardi, R., Pedroni, S. and Crippa, V., "A new travelling sand pluvaitor to reconstitute specimens of well-graded silty sands", Geotechnical Testing Journal, Vol. 16, No. 1, 1993, pp.61-77.   DOI   ScienceOn
2 Schofield, A. N., "Cambridge university geotechnical centrifuge operation, Rankine Lecture", Geotechnique, Vol. 30, No. 3, 1980, pp.227-268.   DOI   ScienceOn
3 Seiji, N., Kosuke, M. and Hirishi, H., "Seismic Design of Cut and Cover Tunnel Based on Damage Analyses and Experimental Studies", Quarterly Report of RTRI, Vol. 40, No. 3, 1999, pp.158-164.   DOI   ScienceOn
4 Stone, K. J. L., Hensley, P. J. and Taylor, R. N., "A centrifuge study of rectangular box culverts", Centrifuge 91, Balkema, Rotterdam, 1991, pp.107-112.
5 Tsutomu, N. and Shigeki, U., "A Simplified Seismic Design Method for Underground Structures Based on the Shear Strain Transmitting Characteristics", Public Works Research Institute, Minamihara, Tsukuba, 2000.
6 Youssef, M. A. H., Jeffrey, J. H., Birger, S. and John, I-C. Y., "Seismic Design and analysis of underground structures", Tunnelling and Underground Space Technology, Vol. 16, No. 4, 2001, pp.247-293.   DOI   ScienceOn
7 Zen, K., Yamazaki, H. and Umehara, Y., "Experimental study on shear modulus and damping ratio of natural deposits for seismic response analysis", Report of the Port and Harbour Research Institute, 1987, pp.26, 41-113.
8 한국지반공학회, 지반구조물의 내진설계, 구미서관, 2006.
9 Idriss, I. M. and Sun, J. I., User's manual for SHAKE91, Center for Geotechnical Modeling Department of Civil & Environmental Engineering, University of California, Davis, 1992.
10 Koji, I., Satoru, O. and Takashi, M., "Seismic Response of Underground Reinforced Concrete Structure - Centrifuge Model Test and Its Analysis", JSCE, Vol. 23, No. 1, 2006, pp.117-124.