• Title/Summary/Keyword: 진동막

Search Result 129, Processing Time 0.029 seconds

Proposition of a Vibration Based Acceleration Sensor for the Fully Implantable Hearing Aid (완전 이식형 보청기를 위한 진동 기반의 가속도 센서 제안)

  • Shin, Dong Ho;Mun, H.J.;Seong, Ki Woong;Cho, Jin-Ho
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.2
    • /
    • pp.133-141
    • /
    • 2017
  • The hybrid acoustic sensor for implantable hearing aid has the structure in which a sound pressure based acoustic sensor (ECM) and a vibration based acceleration sensor are combined. This sensor combines the low frequency sensitivity of an acoustic sensor with the high frequency sensitivity of an acceleration sensor, allowing the acquisition of a wide range of sound from low to high frequency. In this paper, an acceleration sensor for use in a hybrid acoustic sensor has been proposed. The acceleration sensor captures the vibration of the tympanic membrane generated by the acoustic signal. The size of the proposed acceleration sensor was determined to diameter of 3.2 mm considering the anatomical structure of the tympanic membrane and the standard of ECM. In order to make the hybrid acoustic sensor have high sensitivity and wide bandwidth characteristics, the aim of the resonance frequency of the acceleration sensor is to be generated at about 3.5 kHz. The membrane of the acceleration sensor derives geometric structure through mathematical model and finite element analysis. Based on the analysis results, the membrane was implemented through a chemical etching process. In order to verify the frequency characteristics of the implemented membrane, vibration measurement experiment using external force was performed. The experiment results showed mechanical resonance of the membrane occurred at 3.4 kHz. Therefore, it is considered that the proposed acceleration sensor can be utilized for a hybrid acoustic sensor.

In situ analysis of the dynamic characteristics of electro-chemically Polymerized Polypyrrole film using Quartz Crystal Analyzer (Q.C.A.). (Q.C.A. 에 의한 폴리피롤 전기중합막의 동특성 분석)

  • Chang, Sang-Mok;Kim, Jong-Min;Chang, Yong-Keun;Muramatsu, Hiroshi;Ataka, Tatsuaki
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.71-79
    • /
    • 1996
  • The mechanism of electrochemical polymerization of polypyrrole was analyzed using Q.C.A. via measuring the resonant frequency and resonant resistance of AT-cut quartz crystal, whose electrodes were fabricated with indium tin oxide by sputtering method. The quantity of polymerized polypyrrole was able to be calculated from the resonant frequency and the viscoelasticity of polypyrrole film from resonant resistance. We found that the elastic film is formed at the first stage of the polymerization, but transformed to viscoelastic film later and that this transition repeated at some point. From these results, it was confirmed that the rheological characteristics of electrochemically polymerized polypyrrole thin film can be analyzed using Q.C.A.

  • PDF

Curing Behaviors and Viscoelastic of UPE Resins with Different Glycol Molar Ratios (글리콜 몰비가 다른 불포화 폴리에스테르 수지의 경화거동 및 점탄성)

  • Lee, Sang-Hyo;Park, Yung-Hoon;An, Seung-Kook;Lee, Jang-Oo
    • Polymer(Korea)
    • /
    • v.25 no.1
    • /
    • pp.15-24
    • /
    • 2001
  • In this study, the effects of different glycol molar ratios of unsaturated polyester(UPE) resins on the curing behaviors were investigated. The cross linking process was checked or monitored by differential scanning calorimetry(DSC) and by viscoelastic properties of rigid-body pendulum model. The knife-edge from which the pendulum is suspended, is immersed in a reaction mixture, and the change of the viscoelastic behavior brings on those of the period(T) and logarithmic decrement(${\Delta}$) of the damped free oscillations of the pendulum. The values of T and ${\Delta}$ obtained are related to the dynamic modulus(E') and modulus loss(E'). The information on the viscoelastic behavior of unsaturated polyester(UPE) resins during the curing process are shown to illustrate the usefulness of the techniques. As the content of NPG in a propylene glycol(PG)/NPG glycol mixture increased, both the cycle time during cure and the change of damping during cure of UPE resin decreased.

  • PDF

Electronic Structure and Surface Phonon of Ultrathin MgO Layers on TiC(001) Surface (TiC(001) 면에 성장된 MgO 초박막의 전자구조 및 표면포논)

  • Hwang, Yeon;Souda, Ryutaro
    • Korean Journal of Materials Research
    • /
    • v.7 no.8
    • /
    • pp.694-700
    • /
    • 1997
  • TiC(001) 면위에 Mg 금속을 단원자층으로 증착시킨 후 산화 및 열처리 과정을 거쳐서 MgO 초박막을 성장시키고, 성장된 MgO 막의 전자상태 및 표면포논을 UPS, XPS 및 HREELS를 사용하여 측정하였다. 전도성 기판위에 epitaxial 산화물막을 성장시킨 후 성장된 막의 전자구조 및 표면포논을 측정함으로써 벌크에서 분리된 2차원적 특성을 갖는 '표면 모델'의 물성을 연구하고자 하였는데, 이러한 '표면모델'은 잘 배열된 원자구조를 얻을 수 있고 두께가 충분히 얇아서 전하축적을 피할 수 있기 때문이다. 기판으로는 MgO와 같은 암염형 결정구조를 갖고 있고, 격자상수 차이가 2.6% 로서 매우 작으며, 비저항이 매우 낮은 전이 금속 탄화물 중의 하나인 TiC(001) 면을 사용하였다. TiC(001)면에 증착된 MgO층의 UPS He-l 스펙트럼을 측정한 결과 O2p및 XPS스펙트럼은 열처리를 전후로 하여 변하지 않았으며, 이로부터 상온에서 산소의 확산만으로 MgO 상이 형성됨을 알 수 있었다. MgO초박막의 표면 포논을 HREELS를 사용하여 검출하였다. 거시적 포논중에서 F-K 파 및 Rayleigh 모드가 관찰되었는데, F-k파는 MgO막의 2차원성으로 인하여 벌크의 경우보다 높은 진동 에너지를 갖고 있었고 Rayleigh모드는 벌크 MgO와 유사한 분산관계를 보였다. 미시적 포논중에서 Wallis(S/sub 2/)모드가 측정되었는데, 그 진동에너지는 벌크에서와 같고 off-specular방향에서도 소멸되지 않았다.

  • PDF

Design and Evaluation of a Lung Assist Device for Patients with Acute Respiratory Syndrome using Hollow Fiber Membranes (중공사 막을 이용한 급성호흡곤란증후군 환자용 폐 보조 장치의 설계와 평가)

  • Lee, Sam-Cheol;Kwon, O-Sung;Kim, Ho-Cheol;Hwang, Young-Sil;Lee, Hyun-Cheol
    • Membrane Journal
    • /
    • v.15 no.3
    • /
    • pp.224-232
    • /
    • 2005
  • The use of the lung assist device (LAD) would be well suited for acute respiratory failure (ARF) patients, combining the simplicity of mechanical ventilation with the ability of extracoporeal membrane oxygenators (ECMO) to provide temporary relief for the natural lungs. This study's specific attention was focused on the effect of membrane vibration in the LAD. Quantitative experimental measurements were performed to evaluate the performance of the device, and to identify membrane vibration dependence on blood hemolysis. We tried to decide upon excited frequency band of limit hemolysis when blood hemolysis came to through a membrane vibration action. The excited frequency of the module type 5, consisted of 675 hollow fiber membranes, showed the maximum gas transfer rate. We concluded that the maximum oxygen transfer rate seemed to be caused by the occurrence of maximum amplitude and the transfer of vibration to hollow fiber membranes. It was excited up to $25{\pm}5$ Hz at each blood flow rate of module type 5. We found that this frequency became the 2nd mode resonance riequency of the flexible in blood flow. Blood hemolysis was low at the excited frequency of $25{\pm}5$ Hz. Therefore, we decided that limit hemolysis frequency of this LAD was $25{\pm}5$ Hz.

Some Effects of Sliding Velocity on The Elastohydrodynamic Squeeze Films (탄성 경계상 압착막에 대한 미끄럼 속도의 영향)

  • 유형선;이병철
    • Tribology and Lubricants
    • /
    • v.2 no.1
    • /
    • pp.46-52
    • /
    • 1986
  • 얇은 유막위의 타이어 변형해석이나, 압착막댐퍼 설계등의 해석에 응용되는 변동 하중하의 탄성 경계상 유체 압착막의 해석을 Newton-Raphson 반복법을 사용하여 하였다. 유막두께의 계산은 등계수 요소를 사용하여 정확한 계산을 하였고 슬라이더의 궤적은 강쇄진동의 응답곡선과 유사함을 알 수 있었다. 특히 본 연구에서는 미끄럼 속도의 영향을 고려하였으며 유체가 베어링내에 생긴 포켓에 정체하고 있어서 미끄럼의 영향은 속도가 클때를 제외하고는 큰 영향을 미치지 못함을 알 수 있었다.