• Title/Summary/Keyword: 진동감시시스템

Search Result 102, Processing Time 0.03 seconds

Development of Statistical/Probabilistic-Based Adaptive Thresholding Algorithm for Monitoring the Safety of the Structure (구조물의 안전성 모니터링을 위한 통계/확률기반 적응형 임계치 설정 알고리즘 개발)

  • Kim, Tae-Heon;Park, Ki-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.4
    • /
    • pp.1-8
    • /
    • 2016
  • Recently, buildings tend to be large size, complex shape and functional. As the size of buildings is becoming massive, the need for structural health monitoring(SHM) technique is ever-increasing. Various SHM techniques have been studied for buildings which have different dynamic characteristics and are influenced by various external loads. Generally, the visual inspection and non-destructive test for an accessible point of structures are performed by experts. But nowadays, the system is required which is online measurement and detect risk elements automatically without blind spots on structures. In this study, in order to consider the response of non-linear structures, proposed a signal feature extraction and the adaptive threshold setting algorithm utilized to determine the abnormal behavior by using statistical methods such as control chart, root mean square deviation, generalized extremely distribution. And the performance of that was validated by using the acceleration response of structures during earthquakes measuring system of forced vibration tests and actual operation.

사업장의 체계적인 안전관리업무 효율화 방안(화학설비 시스템의 이상고장진단을 위한 Expert System 개발중심으로)

  • Kim, Doo-Hwan;Oh, Jae-Eung;Kim, Woo-Taek;Lee, Chung-Hwi;Shin, Jun
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2000.06a
    • /
    • pp.283-289
    • /
    • 2000
  • 화학공장에서 사고의 원인은 설비의 이송 체결부에서 유해화학 물질의 누출에 의한 경우가 큰 비중을 차지한다. 따라서, 설비의 접합 체결부에서 발생되는 누출현상은 진동원에 대한 이상을 제거하지 않는 한 계속 발생되므로 설비의 주기적인 감시기능이 필수적으로 요구되지만 현재까지는 작업자의 오감에 의하여 정성적인 평가로 대치하는 경우가 대부분이다. (중략)

  • PDF

Design and Application of Emergency Blockage System for Engine Part at IPPT and SQT (IPPT, SQT에서의 엔진부 비상정지 시스템 설계 및 운용)

  • 하성업;이중엽;정태규;한상엽
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.2
    • /
    • pp.44-53
    • /
    • 2003
  • A vertical hot-firing test facility was established to carry out the IPPT(Integrated Propulsion Performance Test) and SQT(Stage Qualification Test) of KSR-III(Korea Sounding Rocket-III). The components for actual launcher were mostly used, hence these tests were carried out under the condition of relatively lower safety margin. To perform hot-firing tests with the maximum safety, an engine emergency blockage system was investigated and applied. An emergency blockage system using combustion chamber pressures and acceleration signals was set up to monitor ignition delay and fail, flame out, propellant feeding status, unstable combustion and excessive structural vibration. With such a system, the test safety could be secured by rapid judgement and follow-up measures, which made IPPT and SQT be safely completed.

Development of acoustic emission monitoring system for the safety of geotechnical structures (지반구조물 안전감시용 미소파괴음 계측시스템 개발)

  • Cheon, D.S.;Jung, Y.B.;Park, E.S.
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.5
    • /
    • pp.471-485
    • /
    • 2014
  • The monitoring method of geotechnical structures using acoustic emission(AE) and microseismicity(MS) is to detect the microscopic deformation and fracture behavior in the inner structures by measuring induced acoustics and vibrations. It can identify a pre-indication of failure by taking advantage of the characteristics that the amount and occurrence rates of AE and MS increase rapidly prior to large scale destruction of the target structures. The monitoring system consisting of high-quality sensors, high-speed data acquisition device and the operation program is required for the practical application of this method. Recently, the AE and MS monitoring systems have been localized. In particular, the developed operation software which can analyze and interpret the measured signals was demonstrated through a number of applications to domestic fields. This report introduces the configuration and features of developed monitoring system, then the challenges and future direction of AE monitoring in geotechnical structures are discussed.

Feature Analysis Based on Beta Distribution Model for Shaving Tool Condition Monitoring (세이빙공구 상태 감시를 위한 베타분포모델에 기반한 특징 해석)

  • Choe, Deok-Ki;Kim, Seong-Jun;Oh, Young-Tak
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.11-18
    • /
    • 2010
  • Tool condition monitoring (TCM) is crucial for improvement of productivity in manufacturing process. However, TCM techniques have not been applied to monitor tool failure in an industrial gear shaving application. Therefore, this work studied a statistical TCM method for monitoring gear shaving tool condition. The method modeled the vibration signal of the shaving process using beta probability distribution in order to extract the effective features for TCM. Modeling includes rectifying for converting a bi-modal distribution into a unimodal distribution, estimating the parameters of beta probability distribution based on method of moments. The performance of features obtained from the proposed method was evaluated and discussed.

Integrated Analysis System for Monitoring and Therapy of Phonation (발성 검사 및 치료를 위한 통합 장치)

  • 남기창;김수찬;김한수;남지인;남도현;김덕원;최홍식
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2883-2886
    • /
    • 2003
  • 좋은 발성을 위하여 음성이 만들어지려면, 뇌의 언어중추의 명령에 의하여 신경망을 통하여 ‘호흡기관(폐와 흉곽. 호흡관련 근육들)’과 ‘발성기관(주로 후두 즉 성대)’ 그리고 ‘조음, 공명기관(인두, 구강 및 비강)’의 근육들이 유기적으로 작용하여야 한다. 이런 협력 체제에 문제가 생기면, 다양한 종류의 질환이 유발될 수 있다[1,2]. 현재 임상에서 음성 분석을 위해 사용되는 시스템은 대부분 성대의 진동을 측정하기 위해 stroboscopy, 전기성문파형검법 (EGG, electroglottography), 후두근전도 중의 한 방법과 음성 분석을 위한 분석 프로그램으로 구성되어 있다. 그러나, 발성은 호흡과 매우 밀접한 관계가 있어 음성, 성대의 진동, 호흡 관계를 종합적으로 관찰할 필요가 있다. 본 연구에서는 발성 시 성대 점막의 접촉 양상은 ECG 로 측정하며, 발성의 주 에너지원이 되는 호흡의 변화를 2 channel 인덕턴스 호흡감시 장치(RIP: repiratory inductive plethymography)를 이용하여 흉곽의 움직임과 상 복강의 움직임에 대하여 측정하며, 발성되는 음성은 마이크로폰을 통하여 측정하는 ‘EGG, 음성, 호흡 통합검사 장치’를 개발하였다.

  • PDF

Development of Remote Diagnostic Monitoring System for Motor-Operated Valves (모터구동밸브의 원격 진단 감시 시스템 개발에 대한 연구)

  • Chanwoo Lim;Jangbom Chai;Seongki Kang;Park, Sungkeun;Shinchul Kang
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.346.2-346
    • /
    • 2002
  • A diagnostic methodology, which utilizes only the remotely-measurable signals, has been requested to be developed in order to evaluate and monitor conditions of MOVs. It is proven that the stem thrust are the most important variables which provide the operability of MOVs. Therefore the stem thrust estimator was developed and validated, which estimates stem thrust by use of the motor torque. The motor torque is calculated using electrical signals which can be measured in Motor Control Center(MCC). (omitted)

  • PDF

Development of a Diagnostic System for a Fuelling Machine (핵연료 교환기 이상 진단 시스템 개발 연구)

  • 천정한;채장범;김태환;김윤철;김용배;홍순성;박완규;서언식
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.596-602
    • /
    • 2001
  • 본 논문에서는 중수로 원자력발전소에서 사용되는 핵연료 교환기 브리지의 상태를 감시하는데 필요한 진단 방법을 도출하였다. 핵연료 교환기는 고방사능 지역에서 작동하기 때문에 신호의 취득은 원격에서 비침투적으로 이뤄져야한다는 제약이 있다. 따라서 비침투적으로 원격에서 측정 가능한 신호들이 선정되었고 선정된 신호를 이용하여 정확한 진단을 위해서 필요한 여러 가지 진단 신호들의 장단점을 비교하였다. 진단 신호로는 모터의 출력 토크를 선정하였고 진단 신호의 타당성을 모형 브리지를 대상으로 수행한 실험을 통하여 검증하였다. 그리고 마지막으로 다양한 환경에서 실험을 하여 브리지의 작동 특성과 결함과 진단 신호와의 관계를 살펴보았다.

  • PDF

Analysis for the dynamic responses of pantograph-overhead contact line coupled system by using a condition monitoring system (상태감시시스템을 이용한 팬터그래프-전차선로 동특성 분석에 관한 연구)

  • Cho, Yong-Hyeon;Park, Young;Lee, Ki-Won;Kwon, Sam-Young;Park, Hyun-June
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.778-781
    • /
    • 2008
  • The aim of this paper is to analyze the dynamic responses of pantograph-overhead contact line coupled system by using a condition monitoring system. The monitoring items are strain, vertical displacement and acceleration of a contact wire. Both strain and vertical displacement in the contact wire depends on uplift force and train velocity. Measurement of acceleration shows that the passage of the pantograph gives an impact force to a hard point on a contact wire.

  • PDF

Development of Condition Monitoring and Diagnosis System for Rotating Machinery (회전기계의 상태감시 및 진단 시스템 개발)

  • 함종석;이종원;박성호;양보석;황원우;최연선;전오성
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.950-955
    • /
    • 2003
  • This paper introduces an enhanced condition monitoring and diagnosis system recently developed for rotating machinery. In the system, the data aquisition/monitoring signal processing, machine condition classifier, case-based reasoning and demonstration modules are effectively integrated with user-friendliness so that machine operators can easily monitor and diagnose the status of rotating machinery in operation. Some of the new features include the directional spectrum, case-based reasoning and neural network techniques. And the demonstrator modules for fault diagnosis of a Bear driving system and for basic understanding of the rotor dynamics are provided to help the potential users better understand the system.

  • PDF