• Title/Summary/Keyword: 진동/충격하중

Search Result 146, Processing Time 0.026 seconds

Simple and Efficient Methods for the Response Estimation of Building Structure Subjected to Human Induced Loads (무리하중을 받는 구조물의 간편하고 효율적인 응답추정)

  • Kim, Tae-Ho;Lee, Dong-Guen;Min, Kyung-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.4 s.44
    • /
    • pp.19-28
    • /
    • 2005
  • Long span structures with low natural frequencies such as shopping malls, large offices, and assembly rooms may experience signification dynamic responses due to human activities. In many cases, the group activities are common thing in comparison with the single activity. The purpose of this study is to evaluate the responses of building structure subjected to group human loads using mode shapes. For this purpose, equations to estimate the magnitudes ol responses ol structure subjected to group walking loads are derived. And the correlation of loads is verified for identifying the relation of each human load composing of group human loads using two load cells. The method is proposed for evaluating the responses of structure subjected to group loads using mode shapes and correlation function related to each human loads. The effectiveness ol the proposed method is verified analytically using a simple beam and floor and experimentally on a footbridge measuring the structural response induced by group pedestrians for the case of synchronization or not. Results indicate that the amplitudes of group walking loads can be easily estimated if the mode shapes are available, and that the corresponding structural responses can be estimated easily by the simple response measurement using the proposed method.

An Experimental Study on the Ultimate Strength and Deformation Capacity of Composite Beams with Eccentric Web Openings (편심유공합성보의 종국내력 및 변형능력에 관한 실험적 연구)

  • Choi, San Ho;Seo, Seong Yeon
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.5 s.48
    • /
    • pp.595-604
    • /
    • 2000
  • Web openings of large beams provide space for wiring, piping, and duct work to provide for proper drainage, pipes and duct must be slightly sloped with the attendant result that all web openings can not be centered on the centroidal axes of the beams. Test specimens are made for opening-depth to beam-depth ratio of 0.5 and for eccentricities of the opening center line of 10% from middepth of the beam because of the proximity of the opening edge to the flange. In this paper, available test results and theories relating to the strength of composite beams having eccentric rectangular openings are surveyed and experiments were carried out to examine the structural behaviors. In all the tests in this paper good agreement is demonstrated with maximum loads measured in tests, and observed failure modes Furthermore, compared with analytical values and experimental values of interaction diagram between moment and shear capacity were safed as it is scattered with outer part of the analytical values.

  • PDF

A Study on Model Establishment and Structural Analysis for Gun Blast Load (기총 폭발 하중에 대한 모델 수립과 구조 해석에 관한 연구)

  • Kim, Dae-Kwan;Han, Jae-Hung;Jang, Jae-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.7
    • /
    • pp.33-39
    • /
    • 2005
  • A mathematical model, GUNBLAST, of blast waves emitted from a gun muzzle is established, and structural response analyses for the blast load are performed. The blast wave can be divided into two kinds of waves, free field and reflected blast waves. In this research, the free field blast wave model is established by the use of a scaling approach, and the reflected blast wave is calculated by using the oblique shock theory and computational fluid dynamic calculation. GUNBLAST is applied to two kinds of structural models. To investigate the effect of the muzzle distance from a structural surface, the blast waves on a plate for various muzzle distances are compared to uniform loads. Moreover, the transient response analysis of an aircraft wing model with a 12.7mm gun is carried out by using MSC/NASTRAN. From the results, it can be shown that the blast wave can cause broad random vibration and high frequency damage to equipments mounted in the aircraft.

Indirect Load Identification for the Operational Load Analysis (동작중 작용부하 분석을 위한 간접적 부하규명)

  • Cho M. S.
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.6 s.81
    • /
    • pp.501-507
    • /
    • 2003
  • Medical devices for helping the rehabilitation of the patients such as orthoses and prostheses should be designed to be strong enough. For the strength design, operational load should be identified first. Furthermore. medical devices are susceptible to dynamic load or shock frequently due to its characteristics. These type of the load may be identified by installing the sensors directly. However, it can modify the natural properties of the structures. Therefore, operational load should be identified indirectly from the system characteristics and responses such as vibrations. In this paper, the basic formulation of the indirect load identification is reviewed and the problems of conventional approach are checked. Then, the new approach based upon the principal component analysis is proposed and the validity of the proposed method is demonstrated using experiments.

Establishment of Testing Method for Abutment Scour Stability by Real-scale Model Test (실대형 교각 실험을 통한 교각 세굴안정성 평가 실험 기법 정립)

  • Lee, Myungjae;Yoo, Mintaek;Kim, Kihyun;Lee, Il-Wha
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.7
    • /
    • pp.5-14
    • /
    • 2019
  • In this study, a prototype abutment was constructed to establish a safety assessment technique of pier and a series of non-destructive tests using impact load. The surcharge load was loaded from 0 tonf to 2.5 tonf on the prototype abutment, and maximum surcharge load was up to 25 tonf. To analyze the behavior of the piers according to the direction of impact, a total of three types of analysis were performed: the direction of the pier, the direction perpendicular to the pier, and the outer direction of the pier. The height of the impact was also tested at each top and bottom. The measuring instrument used an accelerometer to measure the acceleration response when impacted. Based on the series of experimental results, specific values were calculated according to the direction of an impact and the surcharge load using the Fast Fourier Transform (FFT). In addition, the phase difference was used to analyze the pier from the primary 1st mode to the 4th mode.

Response Dominant Frequency Analysis for Scour Safety Evaluation of Railroad Piers (철도 교각의 세굴 안정성 평가를 위한 응답 지배주파수 분석)

  • Jung, Hyun-Seok;Lee, Myungjae;Yoo, Mintaek;Lee, Il-Wha
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.11
    • /
    • pp.83-95
    • /
    • 2020
  • In order to evaluate the stability of the geo-structure of railway bridge, the response dominant frequency was analyzed based on a series of impact vibration load test results. The specifications of the experiment piers were obtained by referring to the completion design data, and when data was missing, a field study was conducted. The impact vibrations test according to the scouring progress was carried out at one pier scheduled to be abandoned, and it was confirmed that the response dominant frequency can be utilized as an evaluation index for scour. In addition, the response dominant frequency was measured through an impact load test at 46 piers in 5 bridges in operation, and the scour safety of the bridge was evaluated by comparing it with the japanese proposal formula.

Environmental Approach to Blasting Effect on the Surrounding Area when the Mine Blasting (광산 발파 시 인근지역에 미치는 발파영향에 대한 환경적 접근)

  • Jeong, Beonghun;Lee, Seungho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.12
    • /
    • pp.5-12
    • /
    • 2015
  • Since blasting noise is impact noise, it will give a sudden shock to the human. In the case, such as the blast vibration, it has given aging buildings and livestock great damage to move the vibration along ground in nearby regions. In this study, the influence of the blasting generated during excavation was analyzed for effects on regional. A couple of field and laboratory surveys about geological were carried out to figure out the geological ratio in the study-performed area. Blast vibration noise was compared to the domestic and abroad case studies and each of the institutions permissible standards established the most appropriate criteria in site condition. The vibration velocity of blasting vibration exploits the values which were measured from test blasting on the ground in order to examine blasting effect. Considering the blasting point as the shortest distance from safety facilities (farms, private houses, etc.), the examination of the influence range, which was derived from the vibration velocity of blasting vibration, was performed to figure out how the point affected the safety facilities. Three-dimensional numerical analysis was performed a time history analysis in order to analyze the behavior of the structure for a dynamic blast load, which was determined in three directions of the blast vibration value. The results of three-dimensional numerical analysis and the blasting effect of blasting vibration estimation equation blasting vibration of impact circle with accompanying test blasting were compared. And the analysis confirmed similar results figures.

An Experimental Study on the Effects of Vertical Vibration during the Initial Curing on the Concrete Strength (수직진동이 초기양생중인 콘크리트의 강도에 미치는 영향에 관한 실험적 연구)

  • Kim Kwang-Soo;Han Kyung-Bong;Park Sun-Kyu;Park Jeong-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.5 s.83
    • /
    • pp.645-650
    • /
    • 2004
  • As time passes, bridge structures require extension work on bridge in use from various effects such as social economical, or traffic environment change. When the concrete is poured at the connection of extension work initial curing concrete is influenced by vibration of vehicles that are passing through the old bridge superstructure. Concrete at early curing stage in construction site should be properly protected, enough to have established sufficient integrity to withstand outside vibration, impact etc. Currently there is no standard specification or regulation in our country. In this paper, experimental variables were divided by vibration velocity and time of loading, and concrete compressive strength and bond strength were measured.

Characteristics of Static Loading and Dynamic Loading Tests for Bridge Capability (교량 내하력 평가를 위한 정적재하시험 및 동적재하시험 특성)

  • Lee, Sang Hun
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.638-649
    • /
    • 2020
  • Purpose: The objective of this study is to evaluate the load carrying capacity of a target bridge structure based on the simple slab bridge of concrete over 20 years of public service. Method: By performing static loading test and dynamic loading test, the displacement, strain, impact factor, and natural frequency values were measured and evaluated through analysis method. Result: The main results of this study are as follows. First, the maximum displacement and maximum strain of S1 were assessed at 2.917 mm and 44.720 𝜇ε( tensile) and -13.760 𝜇ε(compression), respectively, with S2 maximum displacement and maximum strain being 2.100 mm and 4.870 𝜇ε(tensile), respectively. Second, the maximum measured impact factor was 0.191 in section S1 A-A, and the maximum measured impact factor was 0.155 in section S2 C-C. Third, the natural frequency was assessed at 6.086 Hz, and the measurement was found to be within the range of 6.152 Hz to 6.738 Hz. Conclusion: The tested bridge may be evaluated to show good behavior and characteristics for the design load.

Research on Vibration and Noise Characteristics of Steel Plate Girder Bridge with Embedded Rail Track System (레일매립궤도 시스템이 적용된 판형교의 진동 및 소음특성에 대한 연구)

  • Park, Jeung-Geun;Koh, Hyo-In;Kang, Yun-Suk;Jeong, Young-Do;Yi, Seong-Tae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.94-101
    • /
    • 2019
  • Most of the existing rail structures have undergone a lot of aging since a considerable period of time has passed from completion. In particular, among existing railway bridges, many of the plate girder bridges are older bridges that have lived 40 to 60 years or more. Since the treadmill is directly connected to the girder without the ballast, the running load of the vehicle is directly transmitted to the bridge. Therefore, the shock and noise applied to the bridge are larger than those of the ballast bridge, and the dynamic shock and vibration are also relatively large. Therefore, it is very urgent to develop appropriate maintenance, repair and reinforcement technology for existing steel plate bridge. In this study, the authors introduced the characteristics of embedded rail (ERS) developed for improving the performance of the existing plate girder bridge and the techniques solving the vibration and noise problems. In order to evaluate the vibration and noise reduction performance of ERS, a non-ballast plate girder bridge with 5m length of sleepers installed and a plate girder bridge with ERS were fabricated. And, then, the vibration response generated under the same excitation condition was measured and analyzed. Also, the radiated noise analysis was performed using the vibration response data obtained from the experiment as the input data of the acoustic analysis model. As a result of experiments and analyses, it was confirmed that the plate girder bridge's vibration using ERS was reduced by 15.0~18.8dB and the average noise was reduced by 7.7dB(A) more than the non-ballast bridge.