• Title/Summary/Keyword: 진단참조수준

Search Result 14, Processing Time 0.038 seconds

Developing the framework of level diagnosis for green data center (그린데이터센터의 수준진단 프레임워크 개발)

  • Ra, Jong-Hei;Lee, Sang-Hak
    • Journal of Digital Convergence
    • /
    • v.9 no.2
    • /
    • pp.141-152
    • /
    • 2011
  • The data center has become an increasingly important part of most business operations. An increasing demand for computation has led to increasing industry energy consumption. Therefore, higher-than-normal rates of energy efficiency have become a core issue in the life cycle of data center. In this paper, we proposed the framework of level diagnosis for green data centre that can be used to diagnose the levels of capability maturity model. This framework contains the 5 key areas such as construction, air-conditioning, electricity, information technology, organization and indicators that can be applied as basic level diagnosis guide for green data center.

Development of Smart Mining Technology Level Diagnostics and Assessment Model for Mining Sites (광산 현장의 스마트 마이닝 기술 수준 진단평가 모델 개발)

  • Park, Sebeom;Choi, Yosoon
    • Tunnel and Underground Space
    • /
    • v.32 no.1
    • /
    • pp.78-92
    • /
    • 2022
  • In this study, we proposed a diagnostics and assessment model for mining sites that can evaluate the smart mining technology level in a systematic and structured way. For this, the maturity of the smart mining was defined, and detailed assessment items of the diagnostics and assessment model for smart mining were derived by considering the smart factory diagnostics and assessment model (KS X 9001-3) used in the manufacturing industry. While maintaining the existing system, the existing 46 detailed assessment items were modified to be suitable for mining. As a result, a total of 29 detailed assessment items were derived in the areas of promotion strategy, process, information system and automation, and performance. Based on this, a questionnaire was designed to diagnose the level of smart mining technology, and assessment was performed by applying it to domestic iron mines. The level of smart mining technology in the study area was found to be level 2, and it could be inferred that it was about 40% lower than the average smart level of the general manufacturing industry. In addition, by using the developed model, it was possible to recognize the weak points of the mine at each stage of the introduction, operation, and advancement of smart mining, and to suggest investment and improvement directions.

A Study on the Standard Setting for the Basic Skills Competency Test: Focusing on 3rd Grade Basic Mathematics (기초학력 진단평가의 성취수준 설정에 관한 연구: 초등학교 3학년 '기초수학' 사례를 중심으로)

  • Kim, HeeKyoung;Cho, Seongmin
    • Journal of the Korean School Mathematics Society
    • /
    • v.16 no.3
    • /
    • pp.479-498
    • /
    • 2013
  • As education is one of key factors to improve national competitiveness, quality education becomes a top priority in all countries around the world. In South Korea, The Basic Skills Competency Test is administered annually to select below-basic third graders and provide intervention programs. The Basic Skills Competency Test was designed to diagnose the minimal competency of third graders according to a national-level standards. The purpose of this study was to analyze standard-setting procedures and set cut-off scores. This study offered the empirical evidence that standard-setting is generally applicable in schools by the modified Ebel method. More future researches addressing appropriate and efficient standard-setting methods in real school situations are needed to be taken in.

  • PDF

Statistical Homogeneity Tests and Multiple Comparison Analysis for Response Characteristics between Treatments of Bridge Groups (교량 집단의 특성 수준간 통계적 응답 동질성 검정 및 다중 비교 분석)

  • Hwang, Jin-Ha;Kim, Ju-Han;An, Seoung-Su
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.107-117
    • /
    • 2014
  • This study tests homogeneity and performs multiple comparison analysis among treatment levels of each factor group through t-test by materials and analysis of variance by structural type and service period. For that descriptive statistical analysis is performed for static and dynamic response characteristics and their ratios of calculated versus measured values based on a good many safety assessment reports for bridges. Homogeneity and post hoc test based on descriptive statistical analysis provide the measures for homogeneity identification among comparison groups in addition to the statistical reference values such as central tendency, variation and shape. This study is expected to be valuable for structural integrity assessment and design by comparing the measured and calculated values with the reference values for the homogeneous group identified, which can help the engineers review the adequacy of the values and put the group database to practical use.

An Organizational Maturity Assessment Model for Public Data Quality Management (공공데이터 품질관리를 위한 조직 성숙도 평가 모델)

  • Kim, Sunho;Lee, Changsoo;Chung, Seungho;Kim, Hakcheol;Lee, Changsoo
    • Informatization Policy
    • /
    • v.22 no.1
    • /
    • pp.28-46
    • /
    • 2015
  • Although the demand for the use of public data increases in accordance with the expansion of Government 3.0, the poor level of data quality and its management currently implemented is becoming obstacles to opening data to the public. To improve the efficiency of management, linkage and usage for data, standardized processes for data quality management have to be prepared and appropriate data quality assessment criteria should be established. In this paper, we propose the organizational maturity model that can assess the public data quality management level. This model consists of the process reference model and the measurement framework. Fifteen processes grouped by the PDCA cycle are defined in the process reference model. The measurement framework measures the organizational maturity level based on process capability levels. The organizational maturity model can be used to establish objectives and directions for public data quality improvement by diagnosis of current level of public data quality management and problem solving. This model can also facilitate open to the private sector and activate usage of stable public data through reliability enhancement.

A Study on Improving the Quality of the Assessment Items by Analyzing the Types of Their Modification (평가 문항의 질 향상을 위한 문항 수정 유형 분석)

  • Ko, Jung-Hwa
    • School Mathematics
    • /
    • v.12 no.2
    • /
    • pp.113-136
    • /
    • 2010
  • According to the self-assessment tool identifying teacher's competence in assessment, many teachers have difficulty in making assessment tools. This study analyzes the types of modification with data of NAEA(National Assessment of Educational Achievement) items from 2006 to 2008. NAEA goes through complicated formalities from begin to make draft items to completing them. This study shows the types of item modification and its specific examples. NAEA analyzes the degrees of studuents' achievement according to the educational objectives of the National Curriculum. This study provides specific comments on making mathematics assessment items to the teachers who embody national curriculem. Therefore this study will contribute to improve mathematics teacher's professional competence in the area of assessment tool development.

  • PDF

Evaluation of Radiation Entrance Surface Dose Rates for Interventional Radiology Equipment (인터벤션 방사선발생장치에서 입사표면선량률 평가)

  • Kang, Byung-Sam;Chang, Kwang-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.353-357
    • /
    • 2020
  • IVR procedures are on the rise, and patient doses are on the rise. It is necessary to evaluate fluoroscopy dose in IVR procedure. Evaluate ESD on IVR equipment as a reference to DRL settings, I would like to present the direction of improvement in the ESD rate test criteria for fluoroscopy dose. The experimental method is measured with 6cc ionization chamber under the 20cm PMMA Phantom. Radiation is subject to abdominal procedure. The average dose rate of the incident surface was 21.6 ± 11.4 mGy/min. The highest dose equipment was 58.5 mGy/min, and there was no equipment exceeding the domestic standard of 100 mGy/min. However, there were five units above 50 mGy/min. To reduce fluoroscopy dose, it is recommended to reduce pulse rate, The dose increases as the image receptor ages. It is recommended to modify the domestic inspection criteria to 50 mGy/min.

Quality Evaluation of a Shared Cataloging DB : the Case of KOLIS-NET (KOLIS-NET 종합목록 DB의 품질평가)

  • Kim, Sun-Ae;Lee, Soo-Sang
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.40 no.1
    • /
    • pp.95-117
    • /
    • 2006
  • The research purpose for this study is to evaluate the quality of the KOLIS-NET DB which builded bibliographic data of the holding collections of nationwide public libraries. The quality evaluation of the KOLIS-NET DB was inspired by the successful experience from researches precedent and tried to approach the case study focuses on six quality dimensions : coverage, duplication. currentness. accuracy, consistency completeness. The study verified comprehensively the quality of the KOLIS-NET DB through a quality evaluation model and analyzed the factors causing such inferior and substandard bibliographic records in the KOLIS-NET DB. Based on the results of the quality evaluation, the quality improvements of the KOLIS-NET DB was suggested.

An Assessment System for Evaluating Big Data Capability Based on a Reference Model (빅데이터 역량 평가를 위한 참조모델 및 수준진단시스템 개발)

  • Cheon, Min-Kyeong;Baek, Dong-Hyun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.2
    • /
    • pp.54-63
    • /
    • 2016
  • As technology has developed and cost for data processing has reduced, big data market has grown bigger. Developed countries such as the United States have constantly invested in big data industry and achieved some remarkable results like improving advertisement effects and getting patents for customer service. Every company aims to achieve long-term survival and profit maximization, but it needs to establish a good strategy, considering current industrial conditions so that it can accomplish its goal in big data industry. However, since domestic big data industry is at its initial stage, local companies lack systematic method to establish competitive strategy. Therefore, this research aims to help local companies diagnose their big data capabilities through a reference model and big data capability assessment system. Big data reference model consists of five maturity levels such as Ad hoc, Repeatable, Defined, Managed and Optimizing and five key dimensions such as Organization, Resources, Infrastructure, People, and Analytics. Big data assessment system is planned based on the reference model's key factors. In the Organization area, there are 4 key diagnosis factors, big data leadership, big data strategy, analytical culture and data governance. In Resource area, there are 3 factors, data management, data integrity and data security/privacy. In Infrastructure area, there are 2 factors, big data platform and data management technology. In People area, there are 3 factors, training, big data skills and business-IT alignment. In Analytics area, there are 2 factors, data analysis and data visualization. These reference model and assessment system would be a useful guideline for local companies.

Exposure Dose of Thyroid, Breast, and Sexual Gland using a Personal Dosimeter in Multiple CT Examinations (다중 CT 검사 시 개인선량계를 이용한 갑상선, 유방, 생식선의 피폭선량)

  • Kim, Hae-Suk;Kim, Jang-Oh;Lee, Yoon-Ji;Heo, Sung-Hoe;Lee, Chang-Ho;Min, Byung-In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.345-351
    • /
    • 2020
  • In this study, a dose assessment was conducted on the exposure dose of thyroid, breast and sexual gland using a personal dosimeter in multiple CT examinations currently being conducted in health examinations. The dose assessment was measured by attaching TLD and EPD to the locations of the thyroid, breast and sexual gland during CT examinations of Brain, Brain + C-S, Brain + Low lung, Brain + L-S among CT items. The generated dose of equipment, CTDIvol and DLP, was measured. The study found that effective doses were rated 41.7% higher for thyroid TLD in Brain + C-S CT examinations than for the general public, 156% higher for EPD, 10% for breast EPD in Brain + Low Lung CT examinations, 124.4% higher for reproductive TLD and 339.8% higher for Brain + L-S CT examinations. The CTDIvol and DLP analysis results showed that C-S CTDIvol values were higher than the diagnostic reference levels at 0.6%, Low Lung CTDIvol values at 5.7%, DLP values at 11.8% and L-S CTDIvol values at 1.2%. In order to reduce the exposure dose of patients, indiscriminate examination is reduced and dose limit setting is needed in health examination.