• Title/Summary/Keyword: 진단장비

Search Result 743, Processing Time 0.036 seconds

Design & Development of A Diagnostic Monitoring System for CDMA Cellular Phone (핸드폰 진단 시스템의 설계 및 구현)

  • 이상범;김명진
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.4
    • /
    • pp.352-356
    • /
    • 2003
  • The current diagnostic monitoring(DM) systems of cellular phones have many problems since their original technology is came from Qualcom company. Therefore the domestic phone makers only modify the source program and use them within limited applications. In this paper, we have developed our own DM system which is enable to solve the above problems and can be used as a test tool so that problems of phone communications are found easily and quickly. In addition, we will enhance this system to follow the current wireless technique by improving the protocol and enhancing the functions.

  • PDF

실시간 진단 솔루션/통합 관리 운영 SW Platform

  • Hong, Jang-Sik
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.83.1-83.1
    • /
    • 2013
  • 반도체 미세화, Glass 대면적화에 따른 산포관리 및 불량방지 필요(공정이격관리), 설비 데이터만으로는 Sensitivity가 낮아 공정 관리 어려움에 따른 대안 필요, 향후 추가 센서에 대한 접목이 용이한 SW Frame 필요, 양산적용을 위한 설비 및 FAB Host의 자동화 연계 개발 필요, 이종데이터의 통합를 통한 최적의 진단 및 관리가 필요합니다(SCM:툴박스). 즉, 기존의 장비 Parameter가 아닌 실제 공정시 Chamber로부터 얻을 수 있는 물리, 전기, 화학적인 데이터를 적합한 이종(異種) 센서를 직접 부착하여 이들 데이터를 통합 관리 분석 및 실시간 Monitoring을 통한 공정 진단 및 실시간 진단을 실행하는 솔루션입니다. 실 공정 시 적용이 유리한 OES 데이터를 주요 인자로 이외의 기타 데이터를 추가로 통합하여 특화된 분석환경과 공정 모니터링을 통하여 TAT (Turn Around Time)를 줄이고, MTBC (Mean Time Between Clean)를 늘림으로써 궁극적으로 칩메이커의 제품의 가격 경쟁력을 확보 할 수 있는 기능이며, 설비사 입장에서는 자사설비의 지능형 시스템을 위한 제반 기술이기도 합니다.

  • PDF

Self-gated MR cardiac CINE imaging (셀프 동기를 이용한 심장자기공명 씨네영상법)

  • Kim, Pan-Ki;Park, Jin-Ho;Ahn, Chang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2039-2040
    • /
    • 2011
  • 자기공명영상에서 심장의 기능을 진단에 필요한 심장 영상을 얻기 위해서는 심장의 움직임을 모니터 할 수 있는 ECG나 pulse oximeter 등의 장비로 동기를 맞추어 주기위한 트리거 신호가 필요하다. 본 논문은 심장의 움직임을 다른 장비의 도움 없이 동기화하여 자기공명 심장 영상을 재구성하는 새로운 방법을 나선주사영상기법에 적용하여 제안하였다.

  • PDF

The development of digital camera for the medical DF instrument (의료용 DF 장비의 디지털 카메라 개발)

  • 김용민;이성운;구기현;김진용;김승식;문지영
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.76-77
    • /
    • 2003
  • Digital Radiograpy & Fluoroscopy(DRF 또는 DR 또는 DF)는 cone beam을 이용하여 인체를 투과한 X선을 영상증배관(Image Intensifying Tube: IIT)을 통하여 가시광선으로 변환시킨 후 영상을 카메라로 보내고, 이곳에서 발생한 영상정보를 디지털로 처리하여 모니터를 통해 눈에 보이는 영상으로 만드는 방법으로 IIT에 기초한 디지털 방사선 촬영술이라고도 한다. DF 방법은 즉시 영상 표시와 진단이 가능하기 때문에 즉시성이 요구되는 심장이나 두복부 등의 순환기 분야에서 DSA(Digital Subtraction Angiography) 장비로 이용되고 있고, 순환기뿐만 아니라 위를 중심으로 한 소화관(식도, 위, 소장, 대장, 직장)의 분야에서 적용 가능하다. (중략)

  • PDF

A Study on Development and Diagnosis Factors of On-Line DC Leakage Current System for Junctions of High-Voltage Cables in Operation at Thermoelectric Power Station (화력 발전소 고전압 케이블 접속재의 On-Line 직류 누설 전류 시스템 개발과 진단 Factor에 관한 연구)

  • Park, Sung-Hee;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.187-193
    • /
    • 2018
  • There has been a gradual increase in the demand for the electric power in Korea. In order to meet the demand, power station should have technical functions with increased effectiveness. When accident happens in electric machinery at power stations, huge amount of economic losses and mulfunction of equipments occur. One of the accidents is a deteriorated cables operating power stations. In order to prevent cable accident in advance, we should monitor the insulation status of the cable. Cable accidents are resulting from the junctions. We have developed and installed a device in order to identify the status of junction part of power cable at Korea Western Power Co., Ltd.. We performed an accurate diagnosis for the stable utilization of junctions where the accidents occurs most frequently, and to increase the reliability. In this paper, we present the concepts of our device and the method of monitoring diagnosis for the stable use of junctions at cables predicting the life time of cables by analyzing the data obtained by the device. We also present the hardware aspect of the device we have developed.

Failure Detection Filter for the Sensor and Actuator Failure in the Auto-Pilot System (Auto-Pilot 시스템의 센서 및 actuator 고장진단을 위한 Failure Detection Filter)

  • Sang-Hyun Suh
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.4
    • /
    • pp.8-16
    • /
    • 1993
  • Auto-Pilot System uses heading angle information via the position sensor and the rudder device to control the ship direction. Most of the control logics are composed of the state estimation and control algorithms assuming that the measurement device and the actuator have no fault except the measurement noise. But such asumptions could bring the danger in real situation. For example, if the heading angle measuring device is out of order the control action based on those false position information could bring serious safety problem. In this study, the control system including improved method for processing the position information is applied to the Auto-Pilot System. To show the difference between general state estimator and F.D.F., BJDFs for the sensor and the actuator failure detection are designed and the performance are tested. And it is shown that bias error in sensor could be detected by state-augmented estimator. So the residual confined in the 2-dim in the presence of the sensor failure could be unidirectional in output space and bias sensor error is much easier to be detected.

  • PDF

Paper Based Point-of-Care Diagnosis for Appropriate Technology (적정기술을 위한 종이기반 현장 진단 기술)

  • Shin, Kwanwoo;Kwon, Oh-Sun
    • Journal of Appropriate Technology
    • /
    • v.5 no.1
    • /
    • pp.46-53
    • /
    • 2019
  • It should be supported by the ease and economic production in terms of appropriate technology to be widely used in the real applying fields. In particular, the diagnosis of diseases is one of the most difficult areas to apply to the developing countries compared to other fields because of the high costs of professional manpower, equipment, and medial reagents. In recent years, paper, which is one of the most common materials around, has been used to fabricate the disease diagnostic chips, particularly without any special facilities or the equipment. These new technologies lead the possibility of using point-of-care testing devices that can be manufactured quickly in the field by lowering the production cost. These paperbased technologies will contribute to solve many of the deadliest medical problems in developing countries and ultimately improve the quality of human life.

The Evaluation of Space Dose Distribution for Digital Mammography Equipment (디지털 유방촬영장비에 관한 공간선량율 평가)

  • Jung, Hongmoon;Jung, Jaeeun;Hyun, Hyejin;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.61-65
    • /
    • 2015
  • Mammography equipment is an essential detector for making an early diagnosis of female's breast lesion. Recently, in most hospitals, a digital mammography detector is used due to the wide and consistent supply of digital mammography equipment. However, the average effective radiation is increasing due to the indiscreet use of CR or DR mammography. The purpose of this study is to recognize the possible indirect radiation damage, which can be occurred due to an excessive effective exposure of radiation, by evaluating spacial radiation rate of the digital mammography detector used for female patient. Consequently, the high mount of spacial radiation showed digital mammography equipment on the horizontal direction. Considering the result, digital mammography equipment should be installed by avoiding along the horizontal direction.