• Title/Summary/Keyword: 직접 전단 시험

Search Result 276, Processing Time 0.031 seconds

Shear Behavior of Sands Depending on Shear Box Type in Direct Shear Test (직접전단실험시 전단상자의 종류에 따른 모래시료의 전단거동)

  • Hong, Young-Ho;Byun, Yong-Hoon;Chae, Jong-Gil;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.3
    • /
    • pp.51-62
    • /
    • 2015
  • Shear behavior obtained by direct shear tests is dependent on shear box and boundary condition. The objective of this study is to analyze problems of conventional direct shear test (type-A) and provide the reliable results by developing type-C direct shear apparatus. Experimental tests are carried out for Ulleung sand by using type-A and -C direct shear devices. The soil specimens, which are prepared at the relative density of 60%, and are applied to vertical confining stresses of 50, 100, 200, 300, and 400 kPa, are sheared at a constant shear strain rate of 0.5 mm/min. By comparing the results obtained by type-A and -C direct shear apparatus under constant normal load (CNL) condition, the performance of new one is verified. In addition, two constrained conditions including constant normal load (CNL) and constant pressure (CP) are applied to type-C one. Experimental results show that type-A direct shear apparatus has some problems such as rotating of loading plate and upper shear box, and the frictional forces between soil and inner wall of upper shear box. Thus, the shear strengths obtained by type-A device are overestimated or underestimated depending on shear box and boundary condition. On the other hand, type-C device produces clear and consistent test results regardless of constrained conditions. This study represents that type-C direct shear apparatus not only can solve the problems of type-A direct shear apparatus but provide the reliable results.

Comparison of Shear Strength of Coarse Materials Measured in Large Direct Shear and Large Triaxial Shear Tests (대형 직접전단시험과 대형 삼축압축시험에 의한 조립재료의 전단강도 비교)

  • Seo, Minwoo;Kim, Bumjoo;Ha, Iksoo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.1
    • /
    • pp.25-34
    • /
    • 2009
  • Since the particle sizes of the coarse materials used in dam or harbor constructions are much larger than those of typical soils, it is desirable that large shear testing apparatuses are used when performing shear tests on the coarse materials to obtain as accurate results as possible. Two large-scale shear testing apparatuses, large direct shear testing apparatus and large triaxial shear testing apparatus, are commonly used. Currently in Korea, however, there have not been many cases in which shear tests were done using the large apparatus due to mainly difficulties in manufacturing, diffusing, and operating them. In present study, both large direct shear tests and large triaxial shear tests were performed on the coarse materials, which are used as dam fill materials, for 6 test cases in which particle sizes, specimen sizes, vertical pressure (confining pressure) conditions were little different, and then, the shear strength characteristics of the materials were compared with the two different shear tests. The test results showed that, by the Mohr-Coulomb failure criterion, overall the shear strength obtained by the large direct shear tests was larger than that by the large triaxial shear tests. Moreover, the shear strength under the normal stress of 1,000 kPa was about 10 to 70% larger for the large direct shear tests than for the large triaxial shear tests, revealing the larger differences in the coarse materials, compared to typical soils.

  • PDF

A Study on Improvement of Shear Test Apparatus in the Direct Shear Test Under Constant Pressure (정압(CD)조건 직접전단시험에 있어서 시험기의 개선에 관한 연구)

  • Kim Jae Young;Yang Tae Seon;Akihiko Ohshima
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2005
  • A direct shear test is classified roughly by one side simple shear test of confining horizontal displacement type and torsional shear test of non-confining one. Direct shear test that has been widely used so far has some problems with test apparatus, testing and the analysis, and in particular that its strength value is everestimated in sandy soils. Also, progressive failure of shearing process happens from shear apparatus restriction and because the shear strain and shear stress are erratic in specimen, we can not define the shear strain value. In the meantime, a simple shear test having advantage of direct shear test is an ideal test method that can get stress-strain relation on shear because it can deliver constant shearing deformation to specimen. However, simple shear test cannot be used practically, because its structure makes tester manufacturing difficult. This paper described a on outline of test apparatus, improvement of test method, and constant pressure test results based on the obtained from improved direct shear apparatus and the standardization of JGS soil testing method.

An Experimental Study on the Evaluation of Shear Strength of Weathered Soil Containing Coarse Particles (굵은 입자가 포함된 풍화토의 전단강도 평가에 대한 실험연구)

  • Joon-Seok Kim
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.169-176
    • /
    • 2024
  • Purpose: In this paper, an experimental study was conducted to analyze the difference in shear strength caused by the problem of excluding coarse particles due to the size of the test specimen in the direct shear test. Method: A large-scale direct shear test was conducted on three weathered soils containing coarse aggregates with a maximum diameter of 50mm. In addition, a small-scale direct shear test was performed using a sample with a maximum diameter of 5 mm, excluding coarse aggregates. Result: In the case of the small-scale direct shear test, compared to the results of the large-scale direct shear test containing large particles, the internal friction angle was about 2.3% smaller, and there was no significant difference. In terms of cohesion, compared to the large-scale direct shear test, the small-scale direct shear test derived about 80.3% smaller value, showing a relatively large difference. Conclusion: In the large-scale direct shear test, it was analyzed that the coarse particles had a greater impact on the cohesion than the internal friction angle. Therefore, granite weathered clay containing coarse particles is judged to have the same shear strength as the cohesive force that is not affected by vertical stress. In this study, it was analyzed that the small-scale direct shear test, which excludes the coarse particles that are commonly used, provides results on the safety side by excluding the effect of coarse particles.

Case Study on the Shear Characteristics of Limestone Joint Surfaces by Direct Shear Tests (직접전단시험에 의한 석회암 자연절리면의 전단특성 분석사례)

  • Kim, Jong-Woo
    • Tunnel and Underground Space
    • /
    • v.29 no.5
    • /
    • pp.292-304
    • /
    • 2019
  • Limestone joint surfaces with smooth roughness were experimented by means of both the individual direct shear tests based on the KSRM standard test method and the multi-stage direct shear test to apply the stepwise vertical stresses. Changes in the roughness of the joint surfaces before and after the shear tests were examined and the difference between the two kinds of tests mentioned above was analyzed. In both tests, the shear resistance increased as the joint roughness increased and the maximum shear stress required for shearing the joint surface increased as the vertical stress increased. The peak friction angle obtained by the multi-stage direct shear tests was only 63% of that obtained by the individual direct shear tests. In the multi-stage direct shear test, the initial engagement of the concave-convex parts changes frequently during stepwise shearing process, which deforms the original roughness of a joint surface. Accordingly, the individual direct shear test is thought to be more effective when obtaining the friction angle of the rock joint surfaces. Limestone joint surfaces with smooth roughness of JRC value 4~8 were found to have peak friction angle of $47^{\circ}$, residual friction angle of $38^{\circ}$ and cohesion of 37 kPa.

Scale Effects of the Specimen on Shear Strength of sand by Direct Shear Test (직접전단시험에 의한 모래의 전단강도에서 시편의 크기효과)

  • Kim, Joon-Seok;Kim, Ji-Hyun
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.590-596
    • /
    • 2019
  • Purpose: An experimental study was conducted on the sand samples for the size effect of the test specimens, one of the problems of the direct shear test. Method: Jumunjin standard sand, a representative sand of Korea, was used as sand sample. The large direct shear test was performed to analyze the shear strength at 50%, 60%, 70%, and 80% relative density, and then the comparative results were compared with the test results of the small direct shear test. Result: It was analyzed that the internal friction angle of the small shear tester tended to be relatively large in the dense region. It was analyzed that the results of the large shear tester tend to be relatively large in the region of medium relative density. Conclusion: The size effect on the samples in the direct shear test on sandy soil was analyzed to be relatively small.

Strength Character of the Condition of Consolidated Constant pressure with Improvement One-Dimension Shearing Test and Simple Shearing Test (정압(CD)조건의 개량형 일면전단시험과 단순전단시험에 있어서 강도특성에 관한 연구)

  • Kim, Jae-Young;Ohshima, Akihiko;Takada, Naotoshi;Kim, Dong-Hyun;So, Choong-Seop
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.131-136
    • /
    • 2006
  • 일면전단시험은 전단면의 응력을 직접 측정하므로 평면변형시 강도를 파악할 수 있는 등의 많은 장점을 가지고 있으며, 시험조작이 간편하기 때문에 실용적으로도 우수한 것으로 판단된다. 그러나 사질토의 경우에 의한, Dilatancy에 의한 체적변화과정에서 공시체와 전단상자의 주면마찰력이 전단면의 수직 응력을 증감시키기 때문에 구해지는 강도가 과대 또는 과소하게 나타나는 것으로 알려져 있다. 그러나 반력판측에 장착한 하중계를 통해 전단면의 수직응력을 직접 측정 제어하는 형식으로 개선되어 주면마찰력의 영향을 해소하였다. 따라서 본 연구는 반력판측에 하중계를 장착한 개량형 다단식 단순전단시험기를 개발하여 사질토의 정압(CD)조건 전단시험을 수행하여 강도특성과 전단강도에 미치는 영향을 개량형 일면전단시험의 결과와 비교하였다. 그 결과 정압조건의 일면전단시험과 단순전단시험에 의한 강도정수는 조밀한 모래의 경우는 거의 비슷하게 나타나며, 느슨한 모래의 경우는 일면전단이 다소 크게 나타났다. 그리고 단순전단과 일면전단시험에서의 Dilatancy거동에는 큰 차이가 나타나지 않았다.

  • PDF

개량형 일면직접전단시험기의 제작과 정체적.정압조건의 전단시험에 대하여

  • 김재영;류동훈;이재성;대도소언
    • Geotechnical Engineering
    • /
    • v.20 no.5
    • /
    • pp.58-65
    • /
    • 2004
  • 일반적으로 토압, 사면안정, 기초의 지지력 계산 등에 이용하는 강도정수를 결정하기 위한 시험법으로는 일축$.$삼축시험과 직접전단시험이 많이 이용되고 있다. 일축$.$삼축시험은 흙 공시체를 축방향으로 압축 또는 신장 파괴시켜서 압축강도를 구하는 것으로, 활동면의 응력을 Mohr-Coulomb의 파괴 기준으로부터 간접적으로 구하기 때문에 간접전단시험으로 불리고 있다. 특히. 삼축시험은 공시체의 주응력 상태가 명확하기 때문에 연구$.$실용면에서 폭넓게 이용되고 있다. (중략)

  • PDF

The Characteristics of Shear Strength on Weathered Residual Soils for the Effect of Soaking and Disturbance (수침 및 교란 효과에 따른 풍화잔적토의 전단강도 특성)

  • 오세붕;정종혁;이영휘
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.5
    • /
    • pp.125-139
    • /
    • 1999
  • It is difficult to evaluate the shear strength of weathered residual soils because of the difficulties of undisturbed sampling. In this study, a sampling device, direct shear box with shoe, was developed in order to get undisturbed samples easily for direct shear tests, and undisturbed samples could be successfully obtained. Through direct shear tests on undisturbed samples, the shear strength was evaluated with the variation of saturated conditions. In order to consider the effect of disturbance on the shear strength, a static compaction device was developed, and then it was found that undisturbed samples show greater shear strengths than the disturbed ones under natural water contents and similar strengths to the ones under soaked conditions. Further, the shear strength evaluated from direct shear tests was compared with the result of triaxial tests on undisturbed samples, and soaked strengths of the former were similar to the latter. As the result of stability analyses on an actual failed slope, it was found that the shear strength can be evaluated reasonably using direct shear box with shoe.

  • PDF

Calculation Method for Nominal Area of Rock Core Specimen During Direct Shear Test (암석코어시편의 절리면 직접전단시험을 위한 겉보기 면적 계산방법)

  • Kang, Hoon;Park, Jung-Wook;Park, Chan;Oh, Tae-Min;Cho, Jung-Woo
    • Tunnel and Underground Space
    • /
    • v.30 no.6
    • /
    • pp.551-558
    • /
    • 2020
  • This note presents the calculation of nominal area for rock core specimen under direct shear testing condition. The initial nominal area was assumed as ellipsoid, and the equations for calculating the nominal area are derived. The normalized shear displacement and normalized nominal area have an identical relationship regardless of the ellipsoid shape. New testing constants and the generalized method were suggested to calculate the decrease of the nominal area. The method was applied to calculate the direct shear testing data and the changes of result were discussed.