• Title/Summary/Keyword: 직접전단

Search Result 486, Processing Time 0.028 seconds

Evaluation of the Relationship between Geogrid Rib Size and Particle Size Distribution of Ballast Materials using Discrete Element Method (개별요소해석법을 이용한 지오그리드 격자 크기와 도상자갈재료 입도분포 상관관계 평가)

  • Pi, Ji-Hyun;Oh, Jeongho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.1
    • /
    • pp.143-149
    • /
    • 2016
  • This study evaluated the shear behavior of geogrid reinforced ballast material using a large scale direct shear test and discrete element method (DEM) based on PFC 3D program. The direct shear test was conducted on ballast materials that have different particle size distributions. Whereas the test results revealed that the shear strength generally increased with the larger particle size of ballast material without geogrid reinforcement, the shear behavior of ballast material was found to change pertaining to the relationship between particle size distribution and geogrid rib size. Generally, it is deemed the effectiveness of reinforcement can be achieved when the rib size is two times greater than average particle size. A numerical analysis based on DEM was conducted to verify the test results. The geogrid modeling was successfully completed by calibration process along with sensitivity analysis to have actual tensile strength provided by manufacturer. With a given geogrid model, the parametric evaluation was further carried out to examine the interactive behavior between geogrid and ballast material. Consequently, it was found that the effectiveness zone of geogrid reinforcement generated within a specific depth.

Characteristics on Shear Strength and Clogging Phenomenon of Bottom Ash and Rammed Aggregate Mixture Compaction Pile (쇄석과 저회의 혼합다짐말뚝의 전단강도와 Clogging 현상 규명)

  • Lee, Dongyeup;Kang, Hyongnam;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.3
    • /
    • pp.33-41
    • /
    • 2010
  • The rammed aggregate compaction pile method is widely used as soft ground improvement method because of the installed piles improve not only overall composite capacity but also discharge capacity. But the discharge capacity is declined when the clogging is generated due to the clay penetration into voids of rammed aggregate compaction pile with the time elapsed. The purpose of this study is to reduce the clogging problem occurred in rammed aggregate compaction pile constructed in the soft ground and to minimize voids of rammed aggregate compaction pile. The proper mixing ratio was determined which is based on the results of the large scale direct shear tests conducted to get strength and permeability as optimum mixing ratio of crushed stone and bottom ash. The test results indicated that the highest internal friction angle was obtained at 80:20 mixing ratio of crushed stone and bottom ash. The internal friction angle was declined when the mixing ratio of the bottom ash increased over 20%. The results of the clogging tests, presented that the mixture of 80:20 crushed stone and bottom ash is highest effective of clogging than ratio of pure crushed stone.

Characteristics of Shear Strength Parameters of Various Soils by Direct Shear Test (직접전단시험에 의한 다양한 시료의 전단강도 특성)

  • Park, Choonsik;Jeong, Jeonggeun
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.584-595
    • /
    • 2018
  • This study conducted direct shear test on about 290 sorts of materials such as sandy soil, clayey soil and gravely soil to present proper standard on shear strength of soil. Shear strength of soil in large scale tends to show that angle of internal friction increases as sand contents grow and it ranges $23.5^{\circ}{\sim}34.9^{\circ}C$ with cohesion of 2.0 kPa~15.7 kPa. Elastic modulus was visibly distinct by load, and which increased approximately 80% as vertical load grows. Angle of internal friction arranging $15.0^{\circ}{\sim}28.6^{\circ}$ on clayey soil decreased as clay contents rises and cohesion increase in regular scale. Elastic modulus tends to increase initial elastic modulus with almost same growing rate. While angle of internal friction on gravely soil indicates $29.9^{\circ}{\sim}36.7^{\circ}$ which hardly shows distinctive features. According to test in detail, cohesion of SW (well-graded sand), SP (poorly-graded sand), SC (clayey sand) and SM (silty sand) indicates value by 94%, 78% and 59% comparing to SC, SW and SP respectively. Angle of internal friction of ML (low-liquid limit silt) and CL (low-liquid limit clay) appears almost same features, and MH (high-liquid limit silt) despite of 88% value of ML. Cohesion among them varies with similar growing rate.

Shear Strength of Precast Reinforced SHCC Walls (프리캐스트 SHCC 벽판의 전단강도)

  • Kim, Sun-Woo;Lee, Young-Oh;Nam, Sang-Hyun;Chan, Jun-Ho;Ryu, Seung-Hyun;Yun, Hyun-Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.57-58
    • /
    • 2010
  • In this paper, direct tensile strength, $f_t$, and FR index, $F_i$, were considered, and factor ${\alpha}$ between and $f_t$ and $\sqrt{f'_c}$ was estimated through the results of preceding studies on the material properties of SHCCs in order to propose equation for evaluating shear strength of SHCC walls. Shear strength calculated by the proposed equation predicted shear strength of SHCC walls accurately, showing similar tendencies to experimental results.

  • PDF

Shear Strength of Weathered Granite Soil Considering Change of Saturation (포화도 변화를 고려한 화강풍화토의 전단강도)

  • Kim, Minwook;Kim, Youngmuk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.9
    • /
    • pp.5-14
    • /
    • 2010
  • This study was aimed to suggest reliable information of shear strength characteristics due to change of saturation in the landfills or slopes during rainfall infiltration. According to the Mohr-Coulomb failure criteria, the characteristics of shear strength due to change of saturation were analyzed for the weathered residual soils which were sampled in the road construction site of Daejeon city. From the direct shear strength tests, the cohesions and the shear resistance angles were showed maximum values in the condition of optimum moisture content, and then decreased in the condition of wet side compaction. In this study, the cohesions were decreased more than 50% according to increasing saturation by infiltration for the compaction soils. But the reductions of the shear resistance angles were about $1{\sim}2^{\circ}$ which was small value, and thus the changes of the saturation were not nearly influenced the shear resistance angle. The influences of the saturation were seemed to very small for the residual strength parameters according to Mohr-Coulomb failure criteria.

Shear Friction Strength based on Limit Analysis for Ultra-High Performance Fiber Reinforced Concrete (소성 이론에 의한 강섬유 보강 초고성능콘크리트의 전단 마찰 강도식 제안)

  • Lee, Ji-Hyung;Hong, Sung-Gul
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.3
    • /
    • pp.299-309
    • /
    • 2015
  • Ultra High Performance Fiber Reinforced Concrete (UHPFRC) is distinguished from the normal concrete by outstanding compressive and tensile strength. Cracked normal concrete resists shear by aggregate interlocking while clamped by transverse reinforcement, which is called as shear friction theory. Cracked UHPFRC is expected to have a different shear transfer mechanism due to rather smooth crack face and post-cracking behavior under tensile force. Twenty-four push-off specimens with transverse reinforcement are tested for four different fiber volume ratio and three different ratio of reinforcement along the shear plane. The shear friction strength for monolithic concrete are suggested by limit analysis of plasticity and verified by test results. Plastic analysis gives a conservative, but reasonable estimate. The suggested shear friction factor and effectiveness factor of UHPFRC can be applied for interface shear transfer design of high-strength concrete and fiber reinforced concrete with post-cracking tensile strength.

Transfer Length of the Soil Nail Induced by the Shear Deformation (전단변형에 따른 쏘일네일의 전이길이)

  • You, Min Ku;Lee, Sang Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.6
    • /
    • pp.61-73
    • /
    • 2018
  • When the shear deformation occurs on the slope reinforced with soil nail, a passive earth pressure is induced on the ground around the soil nail and the increase of shear deformation causes the earth pressure variation of the ground and the deformation and member force change of the soil nail. In this study, the shear behavior of the soil nail was analyzed experimentally by inducing the shear deformation in the vertical direction of the soil nail using a large-scale direct shear test equipment and it was verified through numerical analysis. The shear test was performed on the bonded length (6D, 8D, 10D and 12D) of the soil nail separated from the shear surface. As a result, it was observed that the continuous increase of the shear deformation caused the damage of the grout and the effect according to the bonded length was analyzed. Through the model test and the numerical analysis, it was confirmed that the transfer length of the soil nail was 0.2~0.22m, which is larger than 0.1m suggested in the previous study, and the shear zone was in the range of 0.6m from the shear surface.

Case Studies on the Experiments for Long-Term Shear Behavior of Rock Discontinuities (암반 내 불연속면의 장기 전단 거동 평가를 위한 고찰)

  • Juhyi Yim;Saeha Kwon;Seungbeom Choi;Taehyun Kim;Ki-Bok Min
    • Tunnel and Underground Space
    • /
    • v.33 no.1
    • /
    • pp.10-28
    • /
    • 2023
  • Long-term shear behavior of the rock discontinuities should be analyzed and its stability should be evaluated to ensure the long-term stability of a high-level radioactive waste disposal repository. The long-term shear behavior of the discontinuities can be modeled with creep and RSF models. The shear creep test, velocity step test, and slide-hold-slide test can be performed to determine their model parameters or analyze the shear behavior by experiments under various conditions. Testing apparatuses for direct shear, triaxial compression, and biaxial shear were mainly used and improved to reproduce the thermo-hydro-mechanical conditions of local bedrock, and it was confirmed that the shear behavior could vary. In order to design a high-level radioactive waste disposal site in Korea, the long-term behavior of rock discontinuities should be investigated in consideration of rock types, thermo-hydro-mechanical conditions, metamorphism, and restoration of shear resistance.

A Study on the Direct Measurement of the Shear Stress of Levee Materials through Large-scale Experiments. (실규모 실험을 통한 제방재료의 한계소류력 실측에 관한 연구)

  • Jung, Dong Gyu;Kim, Young Do;Park, Yong Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.21-21
    • /
    • 2022
  • 충적하천의 하상과 제방은 흐름에 의해 쉽게 침식되는 사립자들로 구성되어 있다. 흐름이 더욱 강해지면 커다란 입자들도 움직이게 되고 더욱 커지면 결국 모든 입자들이 움직인다. 이렇게 흐름에 의해 하상과 제방을 구성하는 사립자들이 움직이기 시작하는 상태를 한계운동이라 하며, 이때의 흐름조건을 한계조건이라 한다. 한계조건은 이동상 수리학의 시작으로, 이때부터 흐름은 물과 유사의 혼합이라는 이상류가 되어 순수한 물의 흐름보다 더 복잡하게 된다. 개수로는 관수로와 달리 반드시 자유수면이 있으며, 따라서 물과 공기와의 마찰은 상대적으로 매우 작으므로 개수로의 전단응력 분포는 관수로와 달리 근본적으로 비대칭이다. 따라서 전단응력은 수로 바닥이나 측벽에서만 작용하게 된다. 한계조건은 이러한 추상적인 의미에 앞서 바닥이 침식되지 않는 하도나 수로의 설계 등에 기본적인 자료가 된다. 개수로에서 경계면의 전단응력을 힘으로 표시하는 것을 통상 소류력이라 하며, 개수로 경계면에서 전단응력의 분포도; 이른바 단면의 평균 전단응력의 개념을 도입하여 해석하고 설계기준으로 제시되고 있다. 본 연구에서는 자연하천과 유사한 조건의 건설기술연구원 하천실험센터의 급경사수로에서 연구를 진행하였으며, 기존 연구를 바탕으로 제작된 소류력 측정장치를 이용하였다. 하천의 설계나 평가에 적용되는 평균 소류력 개념은 복잡한 난류흐름에서 평가지표로써 대표하기 힘들기 때문에 유사 하천환경의 바닥에서 발생하는 소류력을 직접 측정하고자 연구를 진행하였고, 연구결과를 기존의 소류력 산정방법과 비교하였다. 본 연구에 사용된 장치는 실규모 실험을 위해 제작되었으며, 실규모 적용성 검토를 위해 실험실에서 충분한 검증실험을 거친 후 실규모 실험에 적용하였다.

  • PDF

Fheological Properties of PET Containing Thermotropic Polyester (열방성 액정 폴리에스터를 함유한 PET의 유변학적 특성 연구)

  • 김윤수
    • The Korean Journal of Rheology
    • /
    • v.3 no.1
    • /
    • pp.68-75
    • /
    • 1991
  • 상업적으로 많이 이용되는 폴리에틸렌테레프탈레이트(PET)에 액정중합체(LCP)인 열방성 폴리에스터를 첨가하여 유변학적 특성을 조사하고 전단속도와 혼합비에 따른 LCP domain의 형태 변화를 고찰하였다. 모체고분자 내 구형과 타원형을 이루는 LCP domain들 은 신장력에 의해 피브릴 구조의 변형되고 이 피브릴은 흐름방향으로 배향되어 용융체에 윤 활제와 같은 역할을 함으로써 용융점도의 감소를 보이는데 특히 높은 전단속도 영역에서 LCP가 30wt%까지 첨가될수록 큰 폭으로 감소하였다. 주사식 현미경(SEM)의 관찰로부터 LCP domain의 피브릴구조를 확인할 수 있었고 또한 LCP domain의 형태 변화가 용융점도 가 감소에 직접 관계됨을 확인할 수 있었다.

  • PDF