• Title/Summary/Keyword: 직선검출

Search Result 602, Processing Time 0.033 seconds

Arsenic Speciation and Risk Assessment of Miscellaneous Cereals by HPLC-ICP-MS (HPLC-ICP-MS를 활용한 잡곡의 비소 화학종 및 위해 분석)

  • An, Jae-Min;Hong, Kyong-Suk;Kim, Sung-Youn;Kim, Dae-Jung;Lee, Ho-Jin;Shin, Hee-Chang
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.2
    • /
    • pp.119-128
    • /
    • 2017
  • BACKGROUND: Miscellaneous cereal have been largely consumed in Korea as due to their physiological functions beneficial to human health. The cereals are currently a social concern because they have been found to contain heavy metals. Thus, monitoring heavy metals in the cereals is an important requirement for food safety analysis. In this study, we determined arsenic concentration in the cereals randomly harvested from different markets. METHODS AND RESULTS: Inorganic arsenic was determined by ICP-MS coupled with HPLC system. The HPLC-ICP-MS analysis was optimized based on the limit of detection and recover test to reach $0.13-1.24{\mu}g/kg$ and 94.3-102.1%, respectively. The concentrations of inorganic arsenic equivalent to daily exposure were levels of $19.91{\mu}g/day$ in mixed grain, $1.07{\mu}g/day$ in glutinous rice, $0.77{\mu}g/day$ in black brown rice, $0.13{\mu}g/day$ in barley and $0.11{\mu}g/day$ in soybeans. CONCLUSION: The levels of arsenic in miscellaneous cereals were found lower than the recommended The Joint FAO/WHO Expert Committee on Food Additives (JECFA) levels, suggesting that the cereals marketed in Korea are not potential concern in risk assessment.

Method Validation and Quantification of Lutein and Zeaxanthin from Green Leafy Vegetables using the UPLC System (UPLC를 이용한 lutein과 zeaxanthin의 분석법 검증 및 엽채류에서의 정량적 평가)

  • Kim, Suna;Kim, Ji-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.6
    • /
    • pp.686-691
    • /
    • 2012
  • The objective of this research is to present method development and validation for the simultaneous determination of lutein and zeaxanthin using ultra performance liquid chromatography (UPLC). Also, rapid quantification was performed on six green leafy vegetables (Allium tuberosum, Aster scaber, Hemerocallis fulva, Pimpinella brachycarpa, Sedum sarmentosum and Spinacia oleracea) that are commonly consumed in Korea. Separation and quantification were successfully achieved with a Waters Acquity BEH C18 ($50{\times}2.1mm$, $1.7{\mu}m$) column by 85% methanol within 5 min. Two compounds showed good linearity ($r^2$ > 0.9968) in $1-150{\mu}g/mL$. Limit of detection (LOD) and quantification (LOQ) for lutein and zeaxanthin were 1.7 and 5.1 g/mL and 2.1 and 6.3 g/mL, respectively. The RSD for intra- and inter-day precision of each compound was less than 10.69%. The recovery of each compound was in the range of 91.75-105.13%. Aster scaber and Spinacia oleracea contained significantly higher amounts of lutein ($4.06{\pm}0.24$ and $3.97{\pm}0.10mg$/100 g of fresh weight), respectively.

Radioimmunoassay for Determination of Serum Macrophage Migration Inhibitory Factor (혈중 대식세포 유주 저지 인자 측정을 위한 방사면역측정법)

  • Lee, Tae-Sup;Shin, Seok-Hwan;Song, Jee-In;Woo, Kwang-Sun;Chung, Wee-Sup;Choi, Chang-Woon;Lim, Sang-Moo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.532-539
    • /
    • 2004
  • Purpose: There has been a renewal of interest in Macrophage migration inhibitory factor (MIF), especially correlation in pathogenesis of sepsis by many infectious diseases and in regulation of host inflammatory and immune response. We developed immunoradiometric assay (IRMA) to determine serum human MIF concentration. Materials and Methods: The IRMA system utilizes solid phase bound monoclonal anti-recombinant human MIF (rhMIF) antibody as a capture antibody, biotinylated polyclonal anti-rhMIF antibody as a detector antibody. We applied with rhMIF that concentration of standard solutions increased from 0 ng/ml to 100 ng/ml. We used $^{125}I$-streptavidin (SA) as radiotracer to determination of rhMIF concentration. Streptavidin was labeled with $^{125}I$ by Chloramine-T method and $^{125}I$-SA was purified by ultracentrifugation. $^{125}I$-SA stability was evaluated by ITLC analysis at $4^{\circ}C$ and room temperatures until 60days. To validate IRMA system for MIF, we experimented intra-assay and inter-assay coefficients of variation, recovery test and dilution test. Results: Radiolabeling yield of $^{125}I$-SA was 87% and purified $^{125}I$-SA retained above 99% radiochemical purity. $^{125}I$-SA showed above 93% stability in $4^{\circ}C$ until 60days that it is good for immunoradiometric assay as radiotracer. Plotted standard dose response curve showed that increased concentration of rhMIF linearly correlated (R2=0.99) with bound radioactivity of $^{125}I$-SA. The highest intra- and inter-assay coefficients of variation were 5.5% and 7.6%, respectively. The average of recovery of MIF in samples was 102%. In dilution test, linear response curves were obtained (R2=0.97). Conclusion: Radioimmunoassay using $^{125}I$-SA as radiotracer thought to be useful for the determination of serum MIF concentration, and further, its data will be used to evaluate the correlation between clinical significance and serum MIF concentration in patients with various inflammatory diseases.

Establishment of Analytical Method for Methylmercury in Fish by Using HPLC-ICP/MS (고성능액체크로마토그래피-유도결합플라즈마 질량분석기를 이용한 어류 중 메틸수은 분석법 확립)

  • Yoo, Kyung-Yoal;Bahn, Kyeong-Nyeo;Kim, Eun-Jung;Kim, Yang-Sun;Myung, Jyong-Eun;Yoon, Hae-Seong;Kim, Mee-Hye
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.3
    • /
    • pp.288-294
    • /
    • 2011
  • BACKGROUND: Methylmercury is analyzed by HPLC-ICP/MS because of the simplicity for sample preparation and interference. However, most of the pre-treatment methods for methylmercury need a further pH adjustment of the extracted solution and removal of organic matter for HPLC. The purpose of this study was to establish a rapid and accurate analytical method for determination of methylmercury in fish by using HPLC-ICP/MS. METHOD AND RESULTS: We conducted an experiment for pre-treatment and instrument conditions and analytical method verification. Pre-treatment condition was established with aqueous 1% L-cysteine HCl and heated at $60^{\circ}C$ in microwave for 20 min. Methylmercury in $50{\mu}L$ of filtered extract was separated by a C18 column and aqueous 0.1% L-cysteine HCl + 0.1% L-cysteine mobile phase at $25^{\circ}C$. The presence of cysteine in mobile phase and sample solution was essential to eliminate adsorption, peak tailing and memory effect problems. Correlation coefficient($r^2$) for the linearity was 0.9998. The limits of detection and quantitation for this method were 0.15 and $0.45{\mu}g/kg$ respectively. CONCLUSION: Result for analytical method verification, accuracy and repeatability of the analytes were in good agreement with the certified reference materials values of methylmercury at a 95% confidence level. The advantage of the established method is that the extracted solution can be directly injected into the HPLC column without additional processes and the memory effect of mercury in the ICP-MS can be eliminated.

Method Development for Determination of Multi-Mycotoxins in Chicken Liver and Kidney Tissues by LC-MS/MS (LC-MS/MS를 이용한 닭 간과 신장 중 곰팡이 독소 6종 동시분석법 개발)

  • Kim, Soohee;Kim, Kwang-Nam;Kim, Hyobi;Song, Jae-Young;Park, Sung-Won
    • Korean Journal of Poultry Science
    • /
    • v.43 no.2
    • /
    • pp.111-118
    • /
    • 2016
  • Mycotoxins are secondary metabolites produced by molds, such as Aspergillus, Fusarium and Penicillium, that have adverse effects on animals and humans. Aflatoxin, ochratoxin, zearalenone, fumonisin and deoxynivalenol are the mycotoxins of greatest agro-economic importance and cause acute disease called mycotoxicoses. Mycotoxicosis in poultry birds results in decreased meat/egg production, immunosuppressant, and hepatotoxicosis. Some of toxins or their metabolites may be retained in animal or human tissues and induce health problems. This study was designed to develop a sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the simultaneous detection and quantification of mycotoxins, such as aflatoxin $B_1$, aflatoxin $M_1$, ochratoxin A, zearalenone, fumonisin B and deoxynivalenol, in chicken liver and kidney tissues. The mycotoxins were extracted and purified using modified QUECHERS methods, separated by LC and detected by an electrospray ionisation interface (ESI) and tandem MS. Good precision and linearity were observed for most of six mycotoxins. The recovery test for each mycotoxin in liver and kidney tissues mostly indicated good average recovery rates between 80.94% and 98.10% and the coefficient of variation mostly under 13.78%, except for aflatoxin $M_1$ and fumonisin $B_1$. The limit of detection (LOD) for six mycotoxins was $7.6{\sim}145.79{\mu}g/kg$ in liver tissues and $6.07{\sim}197.20{\mu}g/kg$ in kidney tissues. The quantification limits (LOQ) for 6 mycotoxins were in the range $23.04{\sim}441.78{\mu}g/kg$ in liver tissues and $18.40{\sim}597.59{\mu}g/kg$ in kidney tissues, respectively. The developed multi-mycotoxin method in this study permits simultaneous, simple, and rapid determination of several co-existing mycotoxins in chicken liver and kidney tissues.

Simultaneous Determination of Penicillin Antibiotics in Meat using Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS를 이용한 육류 중 페니실린계 항생제 8종의 동시분석 및 적용성 검증)

  • Kim, Myeong-Ae;Yoon, Su-Jin;Kim, MeeKyung;Cho, Yoon-Jae;Choi, Sun-Ju;Chang, Moon-Ik;Lee, Sang-Mok;Kim, Hee-Jeong;Jeong, Jiyoon;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.131-140
    • /
    • 2014
  • The objective of this study was to develop a simultaneous method of 8 penicillin antibiotics including amoxicillin, ampicillin, cloxacillin, dicloxacillin, nafcillin, oxacillin, penicillin G and penicillin V in meat using LC-MS/MS. The procedure involves solid phase extraction with HLB cartridge and subsequent analysis by LC-MS/MS. To optimize MS analytical condition of 8 compounds, each parameter was established by multiple reaction monitoring in positive ion mode. The chromatographic separation was achieved on a $C_{18}$ column with a mobile phase of 0.05% formic acid and 0.05% formic acid in acetonitrile at a flow rate of 0.2 mL/min for 20 min with a gradient elution. The developed method was validated for specificity, linearity, accuracy and precision in beef, pork and chicken. The recoveries were 71.0~106%, and relative standard deviations (RSD) were 4.0~11.2%. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.003~0.008 mg/kg and 0.01~0.03 mg/kg, respectively, that are below maximum residue limit (MRL) of the penicillins. This study also performed survey of residual penicillin antibiotics for 193 samples of beef, pork and chicken collected from 9 cities in Korea. Penicillins were not found in all the samples except a sample of pork which contained cloxacillin (concentration of 0.08 mg/kg) below the MRL (0.3 mg/kg).

Analytical Method Development for Determination of Silymarin by LC-MS/MS for Related Health Functional Foods (LC-MS/MS를 이용한 건강기능식품 중 실리마린 분석법 연구)

  • Oh, Mihyune;Lee, Jin Hee;Kim, Sang-A;Kim, Meehye
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.2
    • /
    • pp.124-130
    • /
    • 2018
  • The Ministry of Food and Drug Safety (MFDS) is amending its test methods for the use of health functional foods (dietary food supplement), in order to establish regulatory standards and specifications in Korea. In this regard, we continue to pursue and perform our research on the analytical method development for the items being researched and reviewed. In this study, we have developed a sensitive and selective test method that could simultaneously separate and determinate six major bioactive flavonolignans in silymarin, which are based on the use of a liquid chromatographic-tandem mass spectrometry (LC-MS/MS). The standard calibration curves presented a linearity effect with the correlation coefficient ($r^2$) > 0.999. The limits of detection (LODs) and limits of quantitation (LOQs) were in the range of $0.3{\sim}9.0{\mu}g/L$ and $0.8{\sim}27.3{\mu}g/L$, respectively. The recovery results ranged between 96.2~98.6% at 3 different concentration levels, and its relative standard deviations (RSDs) were less than 5% as noted in this study. The proposed analytical method was characterized with a noted high resolution of the individual silymarin constituents, and the assay was fully validated as well. Our research can provide a significant scientific evidence that can be useful to amend the silymarin test method for the Health Functional Food Code.

A Study on Phthalate Analysis of Nail Related Products (네일 관련 제품들의 프탈레이트 분석에 관한 연구)

  • Rark, Sin-Hee;Song, Seo-Hyeon;Kim, Hyun-Joo;Cho, Youn-Sik;Kim, Ae-Ran;Kim, Beom-Ho;Hong, Mi-Yeun;Park, Sang-Hyun;Yoon, Mi-Hye
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.3
    • /
    • pp.217-224
    • /
    • 2019
  • Phthalates, endocrine disrupting chemicals, are similar in structure to sex hormones and mainly show reproductive toxicity and developmental toxicity. In this study, we analyzed 11 phthalates, including 3 kinds of phthalates prohibited in cosmetic use and 8 kinds of phthalates regulated in 'Common standards for children's products safety' and EU cosmetic regulation (EC No. 1223/2009). The phthalate analysis was optimized using GC-MS/MS. In analytical method validation, this method was satisfied in specificity, linearity, recovery rate, accuracy and MQL. Therefore, we used this method to analyze 82 products of Nail cosmetics & polish. Although six phthalates such as DBP, BBP, DEHP, DPP, DIBP and DIDP were detected at concentrations of $1.0{\sim}59.8{\mu}g/g$g, they were suitable to Korean cosmetic standards. DIBP and DBP were detected at concentration of $1.1{\sim}2.6{\mu}g/g$ in artificial nail, DBP and DEHP were $1.4{\sim}2.5{\mu}g/g$ in glue for nails, and DIBP, DBP, and DEHP were $2.5{\sim}33.3{\mu}g/g$ in nail stickers. Although substances such as DBP and DEHP in artificial nail, Glue for nails, and nail stickers were detected, they were suitable to 'Common safety standards for children's products. DIBP is not a regulated substance in Korea but showed the third highest detection rate following DBP (84.6%) and DEHP (63.4%). The concentration of phthalates detected in nail products is considered to be safe in current standards but continuous monitoring and research about non-regulated substances are also needed to be considered.

Improvement of analytical method for pymetrozine in citrus fruits (감귤류 과일의 피메트로진 정량을 위한 분석법 개선)

  • Jeon, Jun-Ho;Chun, Su-Hyun;Kim, Min-Hyuk;Kim, Mi-Ok;Lee, Kwang-Won
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.4
    • /
    • pp.316-323
    • /
    • 2019
  • It is difficult to analyze pymetrozine in citrus fruits using the hydromatrix method because of its low efficiency of purification and overlap of matrix and pymetrozine peaks. Liquid-liquid extraction can analyze pymetrozine in citrus fruits using dichloromethane. Since low pH interferes with the extraction of pymetrozine, the extracts of citrus fruits were maintained over pH 7.0 by adding borax buffer and 1 N NaOH in the improved method. According to the improved method, citrus fruits (such as lemon, lime, orange, tangerine, and grapefruit) were extracted and purified for HPLC-photo diode array analysis. The results of validation were as follows: $4.360{\mu}g/kg$ of limit of detection, $14.533{\mu}g/kg$ of limit of quantitation, and 0.007 mg/kg of method quantitative limit. Citrus fruits spiked with pymetrozine showed a recovery range from 71.8 to 83.7% and a coefficient of variation below 6%. Thus, the improved method can efficiently analyze pymetrozine in citrus fruits.

Simultaneous determinations of anthracycline antibiotics by high performance liquid chromatography coupled with radial-flow electrochemical cell (고성능 액체 크로마토그래피/방사흐름 전기화학전지를 이용한 안트라사이클린계 항생제의 동시 정량)

  • Cho, Yonghee;Hahn, Younghee
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.308-314
    • /
    • 2007
  • The analytical method of HPLC with the radial-flow electrochemical cell (RFEC) has been developed to determine doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin simultaneously by employing a reversed-phase chromatography. Anthracyclines were detected at -0.74 V vs. a Ag/AgCl (0.01 M NaCl) reference electrode, a potential of diffusion current plateau in the mobile phase. At a $V_f$ of 1.0 mL/min doxorubicin, epirubicin, daunorubicin and idarubicin appeared at a retention time ($t_r$) of 6.4 min, 7.4 min, 12.7 min and 18.4 min, respectively, while at a $V_f$ of 0.6 mL/min, doxorubicin, epirubicin, nogalamycin, daunorubicin and idarubicin appeared at a $t_r$ of 9.9 min, 11.5 min, 13.5 min, 19.6 min and 28.7 min, respectively. The linearity between each anthracycline injected ($2.40{\times}10^{-7}M{\sim}1.42{\times}10^{-5}M$) and peak area (charge) was excellent with the square of the correlation coefficient ($R^2$) higher than 0.999. The detection limits were $1.0{\times}10^{-8}M{\sim}1.5{\times}10^{-7}M$ for the five anthracyclines. Within-day precision for the five anthracyclines were in reasonable relative standard deviations less than 3 % ($1.00{\times}10^{-6}M{\sim}1.42{\times}10^{-5}M$) except the lower concentrations less than $0.7{\mu}M$. Solid phase extractions of $1.00{\times}10^{-5}M$ epirubicin, $0.48{\times}10^{-5}M$ nogalamycin and $1.52{\times}10^{-5}M$ daunorubicin from human serum with a $C_{18}$ cartridge resulted in 97 %, 100 % and 90 % of recoveries, respectively.