• Title/Summary/Keyword: 직물 센서

Search Result 37, Processing Time 0.034 seconds

Performance Evaluation of Fabric Sensors for Movement-monitoring Smart Clothing: Based on the Experiment on a Dummy (동작 모니터링 스마트 의류를 위한 직물 센서의 성능 평가: 더미 실험을 중심으로)

  • Cho, Hyun-Seung;Park, Sun-Hyeong;Kang, Da-Hye;Lee, Kang-Hwi;Kang, Seung-Jin;Han, Bo-Ram;Oh, Jung-Hoon;Lee, Hae-Dong;Lee, Joo-Hyeon;Lee, Jeong-Whan
    • Science of Emotion and Sensibility
    • /
    • v.18 no.4
    • /
    • pp.25-34
    • /
    • 2015
  • TThis study explored the requirement of fabric sensor that can measure the motion of the joint effectively by measuring and analyzing the variation in electric resistance of a sensor in accordance with bending and stretching motion of the arm by the implementation of a motion sensor utilizing conductive fabric. For this purpose, on both sides of two kinds of knitted fabric, namely 'L' fabric and 'W' fabric Single Wall Carbon Nano-Tube(SWCNT) was coated, fabric sensor was developed by finishing them in a variety of ways, and the sensor was attached to the arm band. The fabric sensor consisted of total 48 cases, namely background fabric for coating, the method of sensor attachment, the number of layer of sensors, the length of sensor, and the width of sensor. The performance of fabric motion sensors in terms of a dummy arm, that is, a Con-Trex MJ with 48 arm bands around it was evaluated. For each arm band, a total of 48, fastened around the dummy arm, it was adjusted to repeat the bending and stretching at the frequency : 0.5Hz, ROM : $20^{\circ}{\sim}120^{\circ}$, the voltage was recorded for each case after conducting three sets of repeat measurement for a total of 48 cases. As a result of the experiment, and as a consequences of the evaluation and analysis of the voltage based on the uniformity of the base line of the peak-to-peak voltage(Vp-p), the uniformity of Vp-p within the same set, and the uniformity of the Vp-p among three sets, the fabric sensors that have been configured in SWCNT coated 'L' fabric / welding / two layers / $50{\times}5mm$, $50{\times}10mm$, $100{\times}10mm$, and SWCNT coated 'W' fabric / welding / two layers / $50{\times}10mm$ exhibited the most uniform and stable signal value within 5% of the total variation rate. Through all these results of the experiment, it was confirmed that SWCNT coated fabric was suitable for a sensor that can measure the human limb operation when it was implemented as a fabric sensor in a variety of forms, and the optimal sensor types were identified.

Evaluating Joint Motion Sensing Efficiency According to the Implementation Method of CNT-Based Fabric Sensors (CNT 기반의 직물센서 구현 방법에 따른 관절동작 센싱 효율 평가)

  • Cho, Hyun-Seung;Yang, Jin-Hee;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.24 no.4
    • /
    • pp.129-138
    • /
    • 2021
  • This study aimed to determine the effects of the shape and attachment position of stretchable textile sensors coated with carbon nanotube on their performance when used to measure children's joint movements. Moreover, the child-safe requirements for fabric motion sensors are established. The child participants were advised to wear integrated clothing equipped with the sensors of various shapes (rectangular and boat-shaped) and attachment positions (at the knee and elbow joints or 4 cm below the joints). The voltage change induced by the elongation and contraction of the fabric sensors was determined for arm and leg flexion-extension motions at 60 deg/s (three measurements of 10 repeats each for 60°and 90°angles, for a total of 60 repetitions). Their dependability was determined by comparing the fabric motion sensors to the associated acceleration sensors. The experimental results indicate that the rectangular-shaped sensor affixed 4 cm below the joint is the most effective fabric motion sensor for measuring children's arm and leg motions. In this study, we designed a textile sensor capable of tracking children's joint motion and analyzed the sensor shape and attachment position on motion sensing clothing. We demonstrated that flexible fabric sensors integrated into garments may be used to detect the joint motions of the human body.

Measurement and Analysis of Surface Roughness by a Non-Contact Method for Objective Assessment of Fabric Handle (직물의 객관적 질감평가를 위한 비접촉식 표면 거칠기 측정 및 해석)

  • 박경희;권영하;오경화;김은애
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.05a
    • /
    • pp.357-360
    • /
    • 2002
  • 직물의 질감을 객관화시키는 연구는 고부가가치의 의류제품을 생산하고 판매하는데 매우 중요한 요소이다. 질감은 직물의 역학적 성질과 표면상태에 따라 좌우되며, 이의 측정방법 중에서 KES-F system이 가장 객관화되어 있다. KES-F system을 이용한 표면 거칠기 측정방법은 피아노선을 굴곡 시켜 일정한 힘을 가한 상태에서 직물의 표면을 문질러 측정하므로 직물의 표면을 문질러 측정하므로 직물 표면의 잔털이 눌려진 상태여서 질감해석을 위한 정확한 측정이 어렵다. 따라서 우리는 기하학적인 직물 표면의 거칠기를 표면의 변형없이 측정 가능한 레이저 센서를 사용하였다. 한편 직물의 주로 경사ㆍ위사로 짜여져 있어 이방성 성질을 가지고 있으므로 직물을 3방향으로 측정하여 해석하였다. 측정된 신호는 FET를 이용하여 일정한 주기의 표면형태를 구하고, 표면 높낮이의 평균, 최저값과 최고값을 구하여 표면의 특성을 얻었다. 직물 표면에 존재하는 잔털은 영상처리장치를 이용하여 양을 측정하였으며 표면의 거칠기 측정결과와 비교 분석하여 레이저 센서를 이용한 비접촉식 측정방법의 오차분석 및 표면 특징을 해석하였다.

  • PDF

Silicone/Pu 처리한 폴리에스테르/면 교직물 표면특성의 측정기법 비교

  • 이선영;홍경희;박연규;강대임
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1999.03a
    • /
    • pp.49-55
    • /
    • 1999
  • 본 연구에서는 표면처리를 달리한 폴리에스테르/면 교직물에 대한 표면특성의 측정기법을 비교·검토하였다. 시료로는 미처리 직물과 silicone 처리 직물, pu 코팅직물, silicone/pu 처리 직물을 이용하였다. 측정 기법은 비접촉식 방법으로 위치에 따른 직물 표면잔털의 grey scale을 FFT하여 그 대수값의 관계식의 기울기값을 결정하였다. 또한, 레이저 변위센서를 이용한 촉각 측정 장치에 의해 표면 거칠기와 표면마찰 계수를 측정하였다. 접촉식 방법으로는 평판과 직물을 접촉시켜 영상처리에 의해 접촉면적을 정량하고 fractal 차원을 도출하였다. KES-FB system에 의해 표면특성을 측정하였다. 주관적 접촉감각 평가는 표준환경에서 20명의 여성을 대상으로 실시하였고 분석에 ANOVA와 상관분석을 이용하였다. 측정기법에 따른 표면특성치와 주관적 감각평가치의 상관분석 결과, 접촉식 방법인 KES-FB에 의한 방법보다 다른 접촉식 방법인 영상처리에 의한 접촉면적, fractal 차원과 비접촉식 방법인 FFT 분석에 의한 기울기 및 레이저 변위센서에 의한 표면거칠기 결과가 주관적 접촉감각과 더욱 밀접한 관련이 있는 것으로 나타나 접촉 감각을 객관화하는데 보다 타당한 것으로 나타났다.

  • PDF

Feasibility Check of Textile Sensor Made of P(VDF-TrFE) for Structural Health Monitoring of Composite Structures (복합재료 구조물의 건전성 모니터링을 위한 P(VDF-TrFE) 직물센서의 가능성 평가)

  • Bae, Ji-Hun;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.30 no.2
    • /
    • pp.126-131
    • /
    • 2017
  • For structural health monitoring of a complex shaped structure a new sensor that can compensate for the drawbacks of the current sensors such as brittleness is needed and the sensor should be highly flexible and durable. In this study a textile sensor made of polyvinylidene fluoride trifluoroethylene (PVDF-TrFE) which is a type of electroactive polymer was fabricated. And the textile sensors were applied to a complex shaped structure (an egg-box panel made of carbon/epoxy composite) for checking their feasibility of structural health monitoring. To correlate the collapse response with failure mechanisms of the structure the multiply-interrupted compressive test was carried out. During the test, the textile sensors succeeded to prove their applicability for damage detection (crack initiation) by generating electric voltages (0.05 V-0.25 V) in the real time.

Development of Wrist Tunnel Syndrome Prevention Smart Gloves using CNT-based Tensile Fabric Sensor: Focusing on Mouse Use (CNT 기반의 인장 직물 센서를 사용한 손목터널증후군 예방 스마트장갑 개발: 마우스사용을 중심으로)

  • Chun, Se-Hwan;Kim, Sang-Un;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.24 no.4
    • /
    • pp.117-128
    • /
    • 2021
  • In this work, we study smart gloves that can prevent carpal tunnel syndrome when using a mouse. Because the left and right wrist movements are fine, a tensile fabric sensor with a large gauge factor and low hysteresis was required before the study. A universal testing machine was used to calculate each gauge rate on four different fabrics, and the fabric with the least hysteresis was selected. In addition, three attachment methods were analyzed using Arduino to select a method with a large sensor value change. For prototypes made by attaching to the selected fabric, data patterns were analyzed using Arduino. The first method identifies only one sensor (A sensor), and the second identifies two sensors (A and B sensors). When the wrist is bent to the right, tensile fabric sensors are attached to both the left (A sensor) and right (B sensor) sides of the wrist, the A sensor is strained, increasing the △sensor value, and the B sensor is relaxed, decreasing the △sensor value. However, when the wrist was bent to the left, the pattern was analyzed in the opposite direction. Through this study, we examined smart gloves to prevent carpal tunnel syndrome with an algorithm that turns on the LED when the wrist is bent, and based on the results of this study, we will directly use mice on 10 people to identify problems and solve problems when used.

Effect of the Shape and Attached Position of Fabric Sensors on the Sensing Performance of Limb-motion Sensing Clothes (직물 센서의 모양과 부착 위치가 사지 동작 센싱 의류의 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Yang, Jin-Hee;Jeon, Dong-Jin;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.20 no.3
    • /
    • pp.141-150
    • /
    • 2017
  • The purpose of this study was to analyze the effect of the shape and attached position of E-textile-based stretchable sensors on motion-sensing performance and to investigate the requirements for the optimal structure of clothes for sensing limb motions. An experimental garment was prepared with different sensor shapes, and attachment positions. A child subject, wearing the experimental garment, performed arm and leg bending and extension motions at $60^{\circ}$, $90^{\circ}$ and $120^{\circ}$ motion angles, at a rate of 60 deg/sec. The changes in voltage triggered by the stretching and contracting of the fabric-sensor were measured, and an acceleration sensor was utilized to verify that the experimental motions were correctly performed. Dummy arms and legs of a child were manufactured to perform an identical test, in order to compare the dummy results with the actual human body experiment results. The analysis showed that the reproducibility and reliability of the rectangular sensor, showing uniform and stable were higher than those of the boat-shaped sensor, in both the dummy and the human body experiments. The attachment position of the sensor was more reproducible and reliable when placed on 4 cm below the elbow and knee joints in the dummy test, when placed in the joints of the elbow and knee, in children experiment. The appropriate shapes and attached positions of the sensor for sensing the motions were analyzed, and the results proved that motion-sensing of the human body is possible by utilizing flexible fabric-sensors integrated into clothes.

A Study on Wearable Emotion Monitoring System Under Natural Conditions Applying Noncontact Type Inductive Sensor (자연 상태에서의 인간감성 평가를 위한 비접촉식 인덕티브 센싱 기반의 착용형 센서 연구)

  • Hyun-Seung Cho;Jin-Hee Yang;Sang-Yeob Lee;Jeong-Whan Lee;Joo-Hyeon Lee;Hoon Kim
    • Science of Emotion and Sensibility
    • /
    • v.26 no.3
    • /
    • pp.149-160
    • /
    • 2023
  • This study develops a time-varying system-based noncontact fabric sensor that can measure cerebral blood-flow signals to explore the possibility of brain blood-signal detection and emotional evaluation. The textile sensor was implemented as a coil-type sensor by combining 30 silver threads of 40 deniers and then embroidering it with the computer machine. For the cerebral blood-flow measurement experiment, subjects were asked to attach a coil-type sensor to the carotid artery area, wear an electrocardiogram (ECG) electrode and a respiration (RSP) measurement belt. In addition, Doppler ultrasonography was performed using an ultrasonic diagnostic device to measure the speed of blood flow. The subject was asked to wear Meta Quest 2, measure the blood-flow change signal when viewing the manipulated image visual stimulus, and fill out an emotional-evaluation questionnaire. The measurement results show that the textile-sensor-measured signal also changes with a change in the blood-flow rate signal measured using the Doppler ultrasonography. These findings verify that the cerebral blood-flow signal can be measured using a coil-type textile sensor. In addition, the HRV extracted from ECG and PLL signals (textile sensor signals) are calculated and compared for emotional evaluation. The comparison results show that for the change in the ratio because of the activation of the sympathetic and parasympathetic nervous systems due to visual stimulation, the values calculated using the textile sensor and ECG signals tend to be similar. In conclusion, a the proposed time-varying system-based coil-type textile sensor can be used to study changes in the cerebral blood flow and monitor emotions.

A Study on the Textile Sensor Applied to Smart Wear for Monitoring Meditation Breathing (명상호흡 모니터링용 스마트의류를 위한 호흡수 측정 직물센서 연구)

  • Hwang, Su Jung;Jung, Yoon Won;Lee, Joo Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.1
    • /
    • pp.83-90
    • /
    • 2018
  • The purpose of this study is for fundamental research of meditation smart wear for physical and mental healing, and researching method for monitoring phase of meditation through textile by measuring the number of abdominal respiration when meditating. For this purpose, the research implemented Single Wall Carbon Nano-Tube (SWCNT) based strain gauges type textile sensor, considered reliability and validity of respiratory sensing, and analyzed efficiency of respiratory sensing based on body parts comparatively. The first preliminary experiment was to evaluate the performance of textile sensor through abdominal model dummy which open and shut of 5 cm repeatedly for 2 minutes at the rate of 0.1Hz in order to simulate abdominal respiration. It concluded signal efficiency between reference sensor(BIOPAC) and textile respiratory sensor appears statistically significant (p<0.001). The second experiment were conducted with 4 subjects doing abdominal respiration under same conditions, and after comparing the signal values between two sensors from 4 attached locations(around center and sides of omphali and phren), center of omphali and sides of phren were selected as suitable location for measuring meditational breathing as they showed large and stable signals. In result, this research aimed for implementing of the textile sensor for sensing meditational breathing of long respiration cycle, review of reliability and validity for sensing number of meditational respiration with the sensor and consideration of sensing efficiency by sensing location on body parts.