• Title/Summary/Keyword: 직렬성

Search Result 502, Processing Time 0.027 seconds

Evaluation of DOM Variations and Reduction Effects in Bioreation Artificial Wetland (생물반응 인공습지 내 DOM 변동 및 저감효과 평가)

  • Joo, Kwangjin;Lee, Jongjun;Kim, Tea-Kyung;Choi, Isong;Chang, Kwang-hyeon;Joo, Jinchul;Oh, Jongmin
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.6
    • /
    • pp.582-594
    • /
    • 2018
  • In this study, the vertical and horizontal flow wetlands were combined in series to create conditions for flow in the exhalation and anaerobic state with the aim of monitoring the variability and reduction of dissolved organic matterin the bio-reactive artificial wetlands, and the performance assessment was conducted as acrylic reaction groups by designing artificial wetlands that filled the functionalresiduals. In case of artificial wetlands in vertical and horizontal planes, the concentration of dissolved oxygen (DO) in the reaction tank was measured as 2.7 mg/L in the vertical flow wetlands under exhalation, and N.D. in the horizontal flow artificial wetlands under anaerobic conditions. The test was carried out by changing the operation time to 140 min, 80 min, and 60 min. The test was conducted with the same natural operation time of 20 min depending on the operation time. All hours of operation were shown to be due to microbial activity. In 3D-EEM, it was found that the longer the driving time was taken, the more reduction the organic compounds in the areas of insoluble human resources, III and V. Further research on the mechanism analysis of future reduction effects is expected to be carried out, but the findings are expected to contribute to the development of technologies for reducing obfuscated substances using artificial wetlands in the future.

The Data Transmission of Image Storage System of PACS (PACS내 영상저장 장치의 데이터 전송)

  • Cho, EuyHyun;Park, Jeongkyu
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.785-791
    • /
    • 2018
  • Recently, Disk array is widely used as a long term storage device in PACS, but reliability is not enough in relation to annual failure rate of disk. Between October 2016 and February 2017, we scanned the serial port of the hard disk while reading or storing medical images on a PACS reader. The data rate was calculated from the data stored in HDD 99ea that were used in the PCAS image storage device and in HDD 101ea that were used in the Personal Computer. When a CT image was read from a PACS reader, Reading was 87.8% and Writing was 12.2% in units of several tens of megabytes or less. When the CT image was stored in the PACS reader, Reading was 11.4% and Writing was 88.6% in units of several tens of megabytes or less. While reading the excel file on the personal computer, Reading was 75% and Writing was 25% in less than 3 MB, and In the process of storing the excel file on the personal computer, Reading was carried out by 38% and Writing was carreid out 62% in the units of 3 MB or less. The transfer rate of the hard disk used in the PACS image storage device was 10 GB/h, and the transfer rate per hour of the hard disk of the personal computer was 5 GB / h. Annual failure rate of hard disk of image storage system is 0.97 ~ 1.13%, Annual failure rate of Hard Disk of personal computer is 0.97 ~ 1.13%. the higher transfer rate is, the higher annual failure rate is. These results will be used as a basis for predicting the life expectancy of the hard disk and the annual failure rate.

Design of Miniaturization Terminal Antenna for 2.4 GHz WiFi Band with MZR (MZR을 이용한 2.4 GHz WiFi 대역 소형 단말기 안테나 설계)

  • Lee, Young-Hun
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.14-21
    • /
    • 2019
  • In this paper, we implemented an on-board miniaturization antenna operating 2.4 GHz using MZR(Mu Zero Resonator). It is must be operating under the constraint that the size of the small terminal PCB should be $78{\times}38{\times}0.8mm^3$ and the size of the system should be $63{\times}38{\times}0.8mm^3$ and the size of the radiating part should be $15{\times}38{\times}0.8mm^3$. The feeding structure uses a CPW structure for stable feeding and a feeding point at the upper left of the system board. A magnetic field coupling structure is used for coupling the feeding part and the antenna. The resonance frequency of the MZR is determined by the series inductance and capacitance of the cell, so the gap between the cells, the length of the cell, the length of the interdigital capacitor, and the spacing between the radiation part and the ground plane are analyzed. The antenna was designed and fabricated using the results. The total size of the antenna including the feed structure is $20.8{\times}9.0{\times}0.8mm^3$, and the electrical length is $0.1664{\lambda}_0{\times}0.072{\lambda}_0{\times}0.0064{\lambda}_0$. The measurement result for 10 dB bandwidth, gain and directivity are 440 MHz(18.3%), 0.4405 dB, and 2.722 dB respectively. It is confirmed that the radiation pattern has omnidirectional characteristics and it can be applied to ultra small terminal antenna.

Implementation of a pipelined Scalar Multiplier using Extended Euclid Algorithm for Elliptic Curve Cryptography(ECC) (확장 유클리드 알고리즘을 이용한 파이프라인 구조의 타원곡선 암호용 스칼라 곱셈기 구현)

  • 김종만;김영필;정용진
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.11 no.5
    • /
    • pp.17-30
    • /
    • 2001
  • In this paper, we implemented a scalar multiplier needed at an elliptic curve cryptosystem over standard basis in $GF(2^{163})$. The scalar multiplier consists of a radix-16 finite field serial multiplier and a finite field inverter with some control logics. The main contribution is to develop a new fast finite field inverter, which made it possible to avoid time consuming iterations of finite field multiplication. We used an algorithmic transformation technique to obtain a data-independent computational structure of the Extended Euclid GCD algorithm. The finite field multiplier and inverter shown in this paper have regular structure so that they can be easily extended to larger word size. Moreover they can achieve 100% throughput using the pipelining. Our new scalar multiplier is synthesized using Hyundai Electronics 0.6$\mu\textrm{m}$ CMOS library, and maximum operating frequency is estimated about 140MHz. The resulting data processing performance is 64Kbps, that is it takes 2.53ms to process a 163-bit data frame. We assure that this performance is enough to be used for digital signature, encryption & decryption and key exchange in real time embedded-processor environments.

Characteristics of Low Temperature Desorption of Volatile Organic Compounds from Waste Activated Carbon in Cylindrical Cartridge (원통형 활성탄 카트리지 내 폐활성탄의 휘발성 유기화합물 저온 탈착 특성)

  • Kang, Sin-Wook;Lee, Seongwoo;Son, Doojeong;Han, Moonjo;Lee, Tae Ho;Hong, Sungoh
    • Clean Technology
    • /
    • v.27 no.1
    • /
    • pp.79-84
    • /
    • 2021
  • In this study, the waste activated carbon used in the painting process was filled into a cylindrical cartridge and the characteristics of desorption by low temperature gas were investigated. Adsorption and desorption experiments of toluene with activated carbon were conducted to determine the flow rate of desorption. In an experiment where desorption was performed while changing conditions at flow rates of 1, 2 and 4 ㎥ min-1, it was determined that 2 ㎥ min-1 was appropriate due to the high THC concentration and desorption time. In the early stage of the desorption of waste activated carbon, 2-butanone and MIBK (methyl isobutyl ketone) with a low boiling point were generated at a high rate in the gas component, and after that, the concentration of THC decreased and the BTX was desorbed at a high rate. The total calorific value of the gas component generated during the desorption of waste activated carbon was 316 kcal kg-1. From repeating the regeneration of waste activated carbon with toluene five times, it was observed that the iodine value and the specific surface area were relatively lower than that of new activated carbon. In the desorption experiment where two cylindrical cartridges were connected in series, the maximum THC concentration was about 470 ppm.

A Study on Awareness of Job Characteristics and Job Satisfaction of Landscape Architect Public Officials in Korea (조경직 공무원의 직무특성 및 직무만족 인식에 관한 연구)

  • Park, Tae-Seok;Kim, Shin-Won
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.44 no.6
    • /
    • pp.148-161
    • /
    • 2016
  • In the case of the government, which plays a pivotal role in the landscape architecture system, the management of positions in landscape architectural organizations is lacking. At the local government level, while public officials for managing landscape architecture are being hired, there are problems and vulnerabilities in both management and system operations as such public officials recruited for positions in landscape architectural services operate under the forestry service. Accordingly, this study analyzed the Korean administrative system of public officials in the landscape architectural service and their satisfaction with the organizational culture and behavior. The aim was to provide practical data for improving the job satisfaction of public officials in landscape architectural service and enhance the status of landscape architecture. First, a survey was conducted regarding current organizational culture/behavior and job adequacy, and differences when compared to different job series with regards to the public officials in the landscape architectural service. The results indicated that job satisfaction of those in landscape architectural service was generally high, but they showed strong centralization, i.e., orders from superiors and limitations on autonomy. Second, an analysis was conducted to improve the organizational culture/behavior and job satisfaction of public officials in the landscape architectural service, and a comparative analysis was conducted on the differences between the analysis result and preceding studies by the Ministry of Government Administration and Home Affairs(2006). The results indicated that organizational commitment/satisfaction of public officials in the landscape architectural service was relatively low among those who had a great amount of work experience related to forestry. Therefore, it was shown that it is necessary to ensure expertise in landscape architecture. Third, a comprehensive analysis was conducted regarding the influences on "working environment", "legal system" and "job allocation" in regard to public officials in land architectural service. The results indicated that satisfaction in the value system was high when given significance to the job as public officials in land architectural. However, their satisfaction in the land architectural system was low due to the lack of independence in their positions, the vulnerable legal system of land architectural service and low employment rates. Fourth, current public officials in landscape architectural service process tasks such as forestry, architecture, city planning and administration that are not related to their area of expertise. Therefore, an analysis was conducted on whether there is a difference in the job satisfaction of public officials in landscape architectural service according to statistical variables. It was identified that "legal system", "job satisfaction" and "organizational commitment" with regard to public officials in landscape architectural service can be improved through ensuring their expertise. This study suggests the following tasks to further inquire into landscape architecture in general. First, establish an identity of work allocation for public officials in the landscape architectural service, and second, establish an organizational constitution according to the positions in landscape architectural service. Accordingly, it is necessary for interested parties of landscape architecture to devise practical strategies so that such tasks can be converged administratively and reflected in policies.

Electrode Characteristics of K+ Ion-Selective PVC Membrane Electrodes with AC Impedance Spectrum (AC 임피던스 분석법을 이용한 K+ 이온선택성 PVC막 전극 특성)

  • Kim, Yong-Ryul;An, Hyung-Hwan;Kang, An-Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.6
    • /
    • pp.870-877
    • /
    • 1998
  • With impedance spectrum measurements, impedance was studied in the interface between sample solutions for $K^+-ion$ selective PVC membrane electrode containing neutral carriers [dibenzo-18-crown-6 (D18Cr6) and valinomycine (Val)]. Response characteristics of electrode were examined by measuring AC impedance spectra that were resulted from the chemical structure and the content of carrier, variation of plasticizer, membrane thickness, doping of base electrolytes, and concentration variation of sample solution. Transport characteristics of PVC membrane electrode were also studied. It was found that the equivalent circuit for the membrane in $K^+$ solution could be expressed by a series combination of solution resistance and a parallel circuit consisting of the bulk resistance and geometric capacitance of the membrane system. But the charge transfer resistance and Warburg resistance were overlapped a little in the low concentration and low frequency ranges. The carrier, D18Cr6 was best for electrode and impedance characteristics, and ideal electrode characteristics were appeared especially in case of doping of the base electrolyte[potassium tetraphenylborate(TPB)]. The optimum carrier content was about 3.23 wt% in case of D18Cr6 and Val. DBP was best as a plasticizer. As membrane thickness decreased the impedance characteristics was improved, but electrode characteristics were lowered for membrane thickness below the optimum. In the case of D18Cr6, the selectivity coefficients by the mixed solution method for the $K^+$ ion were the order of $NH_4{^+}>Ca^{2+}>Mg^{2+}>Na^+$.

  • PDF

Characteristics of Electrode Potential and AC Impendance of Perchlorate Ion-Selective Electrodes Based on Quaternary Phosphonium Salts in PVC Membranes (제4급 인산염을 이용한 과염소산 이온선택성 PVC막 전극의 전극전위와 AC 임피던스 특성)

  • 안형환
    • Membrane Journal
    • /
    • v.9 no.4
    • /
    • pp.230-239
    • /
    • 1999
  • Perchlorate ion-selective electrodes in PVC membranes that respond linearly to concentration 106 M were developed by incorporating the quaternary phosphonium salts as a canier. The effects of the chemical structure, the contents of canier, the kind of plasticizer and the membrane thickness on electrode characteristics such as the electrode slope, the linear respone range and the detection limit were studied. With this results, the detectable pH range, selectivity coefficients and AC impedance characteristics were compared and investigated. The perchlorate ion substituents of the quaternary phosphonium salts like tetraoctylphosphonium perchlorate (TOPP) , tetraphenylphosphonium perchlorate(TPPP), and tetrabutylphosphonium perchlorate(TBPP) as a canier were used. The electrode characteristics were better in the ascending order of TBPP < TPPP < TOPP, with the increase of carbon chain length of the alkyl group. Dioctylsebacate(OOS) was best as a plasticizer, the canier contents were better with 11.76 wt% and the optimum membrane thickness was 0.19 mm. Under the above condition, the electrode slope was 56.58 mV/$^P{ClO}_4$,the linear response range was $10^{-1}$\times$10^{-6}$ M, the detection limit was 9.66 x $10^{-7}$ M. The performance of electrode was better than Orion electrode. The electrode potential was stable within the pH range from 3 to 11. The order of the selectivity coefficients for the perchlorate ion was sol < F < Br < 1. With the result of impedance spectrum, it was found that the equivalent circuit for the electrode could be expressed by a series combination of solution resistance, parallel circuit consisting of the double layer capacitance and bulk resistance and Warburg impedance. And solution resistance was almost not appeared and Warburg impedance was highly appeared by diffusion. Then Warburg coefficient was 1.32$\times$$10^74 $\Omega$ $\cdot$ ${cm}^2/s^{1/2}$.

  • PDF

Current State and Future Direction of Professionals of Records Management (기록물관리 전문요원의 운영 현황과 전망)

  • Lee, Young-Hak
    • The Korean Journal of Archival Studies
    • /
    • no.21
    • /
    • pp.323-353
    • /
    • 2009
  • This study examines current states of Professionals of records management after "Records Management of public instituition Act(공공기관의 기록물 관리에 관한 법률)" was enacted in 1999. The law forced to arrange records manager in Records Center. However the hire of Professionals of records management became in earnest in 2005. Records Manager among the research officials was established in 2005 February in the Participatory Government. Because of this regulation, in 2005 July, Professionals of records management were arranged in each of 45 central department for the first time. Going through many trial and error, Professionals of records management contributed to systemizing record management of center department and office. According to "Public Records Management Act(공공기록물 관리에 관한 법률)" totally revised in 2007, sixteen major cities and its public office of education decided to employ Professionals of records management until the end of 2007. In addition, minor cities which consists of people over 150,000 and public office of education which consist of the number of students over 70,000 are supposed to have Professionals of records management until 2008, but it is not accomplished yet. Furthermore, when recruiting professionalists of records management, it is necessary to employ not as a contract or a part-time employee or but as a regular or a full-time worker. Especially, if the specialists of record management were employed as a part-time employee, they would not concentrate on their work because of their unstable social positions. It means that changes from a contract worker to a regular employee are needed without further delay. At first, records managers who were recruited at the Central Department in May 2007 had various kinds of difficulties and experienced trial and error. These days, however, they show their expertise with finding their own works. Someday in Korea, the records manager is expected to be a professional career with their know-hows and active movements.

Low price type inspection and monitoring system of lithium ion batteries for hybrid vessels (하이브리드 선박용 리튬 배터리의 저가형 감시시스템 구현)

  • Kwon, Hyuk-joo;Kim, Min-kwon;Lee, Sung-geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.28-33
    • /
    • 2016
  • Batteries are used for main power engine in the fields such as mobiles, electric vehicles and unmanned submarines, for starter and lamp driver in general automotive, for emergency electric source in ship. These days, lead-acid and the lithium ion batteries are increasingly used in the fields of the secondary battery, and the lead-acid battery has a low price and safety comparatively, The lithium ion battery has a high energy density, excellent output characteristics and long life, whereas it has the risk of explosion by reacting with moisture in the air. But Recently, due to the development of waterproof, fireproof, dustproof technology, lithium batteries are widely used, particularly, because their usages are getting wider enough to be used as a power source for hybrid ship and electric propulsion ship, it is necessary to manage more strictly. Hybrid ship has power supply units connected to the packets to produce more than 500kWh large power source, and therefore, A number of the communication modules and wires need to implement the wire inspection and monitor system(WIIMS) that allows monitoring server to transmit detecting voltage, current and temperature data, which is required for the management of the batteries. This paper implements a low price type wireless inspection and monitoring system(WILIMS) of the lithium ion battery for hybrid vessels using BLE wireless communication modules and power line modem( PLM), which have the advantages of low price, no electric lines compared to serial communication inspection systems(SCIS). There are state of charge(SOC), state of health(SOH) in inspection parts of batteries, and proposed system will be able to prevent safety accidents because it allows us to predict life time and make a preventive maintenance by checking them at regular intervals.