• Title/Summary/Keyword: 직각도 추정

Search Result 26, Processing Time 0.025 seconds

A Study on the Fatigue Strength of the Welded Joints in Steel Structures(I) (강구조물(鋼構造物)의 용접연결부(鎔接連結部)의 피로강도(疲勞强度)에 관한 연구(研究)(I))

  • Park, Je Seon;Chang, Dong Il;Chung, Yeong Wha
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.3
    • /
    • pp.161-175
    • /
    • 1985
  • The simplified method drawing the S-N curves in welding joints of the cover plates, the transverse stiffners and the gusset plates of the plate girders by calculation and its computer program without the direct fatigue tests, was established. And the method was applied to the Young- Dong Great Bridge, the 3 th Han River Bridge and the Kang Chon Bridge. Before this, SS 41, SS 50, SWS 50 and SWS 58 were selected, then the compact tension specimens were made by the use of these materials, the things welded by these materials transversely and the ones longitudinally to the crack propagation direction. The fatigue tests were performed by the use of these 'specimens, and the values of material constants c and m were obtained. By these results the followings were obtained. It was showed that the fatigue: strength in the case of the cover plates was much lower than in the case of other two cases. It was showed that, in the case of the cover plates with the cover plates thicker the fatigue strength was lower, but besides this the fatigue strength was not much influenced by the size of specimens. It was showed that in the difference from this the fatigue strength was sensitively influenced by the values of c and m. It was showed that in accordance with the lower values of c and m the fatigue strength was fairly higher, in accordance with the lower values of m the gradient of the S-N curves was abrupter. It was considered that if such data were accumulated continuously, in the near future the basic pattern used availably in providing the indicater of the fatigue design of the plate girders, and presuming the life-proof of the existing plate girders.

  • PDF

Growth and Survival of the Spat of Arkshell, Scapharca broughtonii in Intermediate Culture with Different Shape of Protective Net and Type of Preventive Net of Spat Loss (피조개, Scaphara broughtonii 부착치패의 중간양성시 보호망 형태와 유실방지망 종류에 따른 성장과 생존)

  • Kim, Byeong-Hak;Shin, Yun-Kyung;Park, Ki-Yeol;Choi, Nack-Joong;Oh, Bong-Se;Min, Byeong-Hee
    • The Korean Journal of Malacology
    • /
    • v.24 no.2
    • /
    • pp.131-136
    • /
    • 2008
  • Growth and survival of the spat of arkshell, Scapharca broughtonii were investigated for the improvement of survival in intermediate culture with different shape of protective net and type of preventive net of spat loss. The growth performance of the spat of arkshell was observed for 60 days by using different forms of protective net, as the exposure form with an average shell length of $12.8{\pm}3.2$ mm(P<0.05), the fish pot form with $12.2{\pm}3.5$ mm, the cylinder form with $11.9{\pm}3.8$ mm and the last one is the rectangular form with $10.9{\pm}3.7$ mm. Their numerical value did not show any marked difference with each other. But in case of survival rate, the fish pot form showed highest survival rate which is 43.7% and the significantly lowest was showed by the exposure form, which is 5.4%(P<0.05). The cylinder form and rectangular form showed 41.2 and 31.6% respectively. And then the growth of the spat of arkshell was observed for 163 days by rearing in a sort of preventive net, the first group was in a blackout curtain with average shell length of $13.9{\pm}3.1$ mm, the next group was in a balsam pear net with $12.9{\pm}3.0$ mm, in a polyethylene net with $11.8{\pm}3.1$ mm and the control with $12.6{\pm}3.3$ mm which was not installed by preventive net of spat loss. The survival rate was 91.5% in a blackout curtain, 90.1% in a polyethylene net, 88.5% in a balsam pear net and 61.5% in a controlled group. It is seen that the highest growth and survival rate were observed in a fish pot form and cylinder form. These results were a little bit difference from those of the spat of arkshell cultured in the form of different preventive nets. There was no significant difference in survival rate in relation to the sorts of preventive net against carrying-away, but there was a difference in survival rate by more than 30% as against the non-installed controlled group. We expect that survival rate would be highly improved in intermediate culture carried out with fish pot form and cylinder form of protective net and preventive net of spat loss.

  • PDF

Factorial Validity of the Korean Version of the Illness Intrusive Rating Scale among Psychiatric Outpatients Mainly Diagnosed with Anxiety or Depressive Disorders (불안 및 우울장애를 주요 진단으로 하는 정신건강의학과 외래환자 대상 한국판 질병침습도 평가척도의 요인 타당도 연구)

  • Cho, Yubin;Kim, Daeho;Kim, Eunkyung;Jo, Hwa Yeon;Yun, Mirim;Lee, Hoseon
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.27 no.2
    • /
    • pp.77-84
    • /
    • 2019
  • Objectives : The Illness Intrusiveness Rating Scale (IIRS) is a well-validated self-report instrument for assessing negative impact of chronic illness and/or adverse effects of its treatment on everyday life domains. Although extensive literature probed its psychometric properties in medical illness, little attention was paid for its validity for psychiatric population. This study aimed to test factorial structure of the Korean Version of the IIRS (IIRS-K) in a consecutive sample of psychiatric outpatients. Methods : Data set of 307 first-visit patients of psychiatric clinic at Guri Hanyang univ. Hospital were used. Exploratory and confirmatory factor analysis, internal consistency were tested in IIRS-K. We also checked Spearman's correlation analysis between IIRS-K, Zung's self-report anxiety scale and Zung's self-report depression scale. Results : 76.9% of the patients were with anxiety disorder and depressive disorder. The principal component factor analysis of the IIRS-K extracted three-factor structure accounted for 63.2% of total variance that was contextually similar to the original English version. This three-factor solution showed the best fit when tested confirmatory factor analysis compared to the original IIRS, two-factor model of IIRS-K suggested from medical outpatients, and one-factor solution. The IIRS-K also showed good internal consistency (Cronbach's α=0.90) and good convergent validity with anxiety and depression scales. Conclusions : The IIRS-K showed the three-factor structure that was similar but not identical to original version. Overall, this study proved factorial validity of the IIRS-K and it can be used for Korean clinical population.

Time Change in Spatial Distributions of Light Interception and Photosynthetic Rate of Paprika Estimated by Ray-tracing Simulation (광 추적 시뮬레이션에 의한 시간 별 파프리카의 수광 및 광합성 속도 분포 예측)

  • Kang, Woo Hyun;Hwang, Inha;Jung, Dae Ho;Kim, Dongpil;Kim, Jaewoo;Kim, Jin Hyun;Park, Kyoung Sub;Son, Jung Eek
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.279-285
    • /
    • 2019
  • To estimate daily canopy photosynthesis, accurate estimation of canopy light interception according to a daily solar position is needed. However, this process needs a lot of cost, time, manpower, and difficulty when measuring manually. Various modeling approaches have been applied so far, but it was difficult to accurately estimate light interception by conventional methods. The objective of this study is to estimate the spatial distributions of light interception and photosynthetic rate of paprika with time by using 3D-scanned plant models and optical simulation. Structural models of greenhouse paprika were constructed with a portable 3D scanner. To investigate the change in canopy light interception by surrounding plants, the 3D paprika models were arranged at $1{\times}1$ and $9{\times}9$ isotropic forms with a distance of 60 cm between plants. The light interception was obtained by optical simulation, and the photosynthetic rate was calculated by a rectangular hyperbola model. The spatial distributions of canopy light interception of the 3D paprika model showed different patterns with solar altitude at 9:00, 12:00, and 15:00. The total canopy light interception decreased with an increase of surrounding plants like an arrangement of $9{\times}9$, and the decreasing rate was lowest at 12:00. The canopy photosynthetic rate showed a similar tendency with the canopy light interception, but its decreasing rate was lower than that of the light interception due to the saturation of photosynthetic rate of upper leaves of the plants. In this study, by using the 3D-scanned plant model and optical simulation, it was possible to analyze the light interception and photosynthesis of plant canopy under various conditions, and it can be an effective way to estimate accurate light interception and photosynthesis of plants.

Experimental Study of Flip-Bucket Type Hydraulic Energy Dissipator on Steep slope Channel (긴구배수로 감세공의 Filp Bucket형 이용연구)

  • 김영배
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.1
    • /
    • pp.2206-2217
    • /
    • 1971
  • Spillway and discharge channel of reservoirs require the Control of Large volume of water under high pressure. The energies at the downstream end of spillway or discharge channel are tremendous. Therefore, Some means of expending the energy of the high-velocity flow is required to prevent scour of the riverbed, minimize erosion, and prevent undermining structures or dam it self. This may be accomplished by Constructing an energy dissipator at the downstream end of spillway or discharge channel disigned to dissipated the excessive energy and establish safe flow Condition in the outlet channel. There are many types of energy dissipators, stilling basins are the most familar energy dissipator. In the stilling basin, most energies are dissipated by hydraulic jump. stilling basins have some length to cover hydraulic jump length. So stilling basins require much concrete works and high construction cost. Flip bucket type energy dissipators require less construction cost. If the streambed is composed of firm rock and it is certain that the scour will not progress upstream to the extent that the safety of the structure might be endangered, flip backet type energy dissipators are the most recommendable one. Following items are tested and studied with bucket radius, $R=7h_2$,(medium of $4h_2{\geqq}R{\geqq}10h_2$). 1. Allowable upstream channel slop of bucket. 2. Adequate bucket lip angle for good performance of flip bucket. Also followings are reviwed. 1. Scour by jet flow. 2. Negative pressure distribution and air movement below nappe flow. From the test and study, following results were obtained. 1. Upstream channel slope of bucket (S=H/L) should be 0.25<H/L<0.75 for good performance of flip bucket. 2. Adequated lip angle $30^{\circ}{\sim}40^{\circ}$ are more reliable than $20^{\circ}{\sim}30^{\circ}$ for the safety of structures.

  • PDF

Studies on a Plan for Afforestation at Tong-ri Beach Resort(II) -Analyses of Crown Amounts and Soil Properties in the Disaster-damage Prevention Forests of Pinus thunbergii PARL., the Valuation on Soil Properties for Planting and Planning for Afforestation- (통리(桶里) 해수욕장(海水浴場) 녹지대(綠地帶) 조성(造成)에 관(關)한 연구(硏究)(II) -곰솔 해안방재림(海岸防災林)의 수관량(樹冠量) 및 토양분석(土壤分析), 식재기반평가(植栽基盤評價) 및 녹지대계획(綠地帶計劃)-)

  • Cho, Hi Doo
    • Journal of Korean Society of Forest Science
    • /
    • v.77 no.3
    • /
    • pp.303-314
    • /
    • 1988
  • Tong-ri beach has not enough vegetation to be enjoyed by the sea bathers and to be satisfied with preventing the disaster-damages, but mixed forest near the beach can work its funtions and the old forest of Pirus thunbergii $P_{ARL}$. near the beach do a Little. Therefore it is very urgent to plant more trees near the beach for bathers and disaster-damage prevention. This study was carried out for planning an afforestation, with reporting upon the crown amounts and soil properties of disaster-damage prevention forests of P. thunbergii $P_{ARL}$. planted on the coast sand dunes in 1970 and 1976, and with reporting upon the valuation on soil properties of the lands near the beach in order to set the afforestation site. The results are as follows : 1. In disaster-damage prevention forests, crown surface area and crown volume became increasingly greater in proportion to the height. To D.B.H., crown volume also became increasingly greater in proportion, but crown surface area was directly proportional. 2. In comparison to sail characteristics of sand dune, those of the forests were in large quantity in OM, T-N and avail. $SiO_2$, and almost in the same in avail. $P_2O_5$, but in small quantity in exchangeable canons : K, Ca, Mg and Na. 3. EC, Cl and pH were in small value in the forest soils, but CEC was in large value in those soils. 4. Above facts showed that the forests fulfill their functions for preventing disaster-damages and improve their soil properties. 5. The forests have naturally been thinned up to 34% in 17 years and 39% in 11 years, and one can easily pass through the forest(planted in 1970), because of its sufficient clear-length(2.71m) and its space to pass. 6. A plan for afforestation was oracle nut after judging several sites by the evaluation on the soil properties and considering the best relaxation and the prevention of the various disaster-damages upon which were reported in the last issue. 7. Afforestation should be kept for maintaining its appropriate density for best relaxation and disaster-damage prevention.

  • PDF