• Title/Summary/Keyword: 지혈

Search Result 283, Processing Time 0.04 seconds

Arthroscopic Posterior Cruciate Ligament Reconstruction without Tourniquet (지혈대 없이 시행한 관절경하 후방십자인대 재건술)

  • Kim, Sang-Bum;Lee, Young-Goo;Son, Jung-Hwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.94-97
    • /
    • 2004
  • Purpose: To report the results of arthroscope assisted posterior cruciate ligament reconstruction without tourniquet, which has not yet been reported in documents within the country. Materials and Methods: Out of the 75 cases of arthroscope assisted posterior cruciate ligament reconstruction on patients with posterior cruciate ligament damage from January, 1998 to May,2003 in this hospital, study was done on 49 cases of patients with isolated posterior cruciate ligament damage, excluding 16 cases of patients who were applied tourniquet in extraarticular operation due to combined damage such as in lateral collateral ligament and posterolateral collateral ligament, and 10 cases where the postoperative observation period was less than 12 months. There were 13 cases where reconstruction was done using autogenous bone-patella tendon-bone, 19 cases using allogenous bone-patella tendon-bone, and 17 cases using allogenous achilles tendon. For assessment, the 49 cases were compared using Lysholm knee scoring scale. Results: The average duration of operation was 105 minutes. There were no severe complications such as swelling, bleeding, infection etc . Assessment results attained by Lysholm knee scoring scale was 74(fair) for cases where autogenous bone-patella ten-don-bone was used,75(fair) for cases where allogenous achilles tendon was used, and 76(fair) for cases where allogenous bone-patella tendon-bone was used. Conclusion: There are no difficulties to perform the arthroscopic assisted posterior cruciate ligament reconstruction. Reconstruction without tourniquet can be thought to prevent complications that could follow when using it.

  • PDF

Difference in Bonding Strength of RMGIC according to Type of Hemostatic Agent in Primary Tooth (지혈제의 종류에 따른 레진 강화형 글라스아이오노머 시멘트 결합력의 차이)

  • Back, Seolah;Lee, Joonhaeng;Kim, Jongbin;Han, Miran;Kim, Jong Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.460-466
    • /
    • 2021
  • The purpose of this study was to compare the effect of the hemostatic agent containing aluminum chloride with hemostatic agent containing ferric sulfate on the shear bond strength of resin-modified glass ionomer cement(RMGIC) to dentin in primary tooth. Twenty extracted non-carious human primary teeth were collected in this study. The specimens were cut to expose dentin and polished. The specimens were randomly seperated into 3 groups for treatment; group I: polyacrylic acid(PAA), RMGIC; group II: aluminum chloride, PAA, RMGIC; group III: ferric sulfate, PAA, RMGIC Ten specimens from each group were subjected to shear bond strength test. The mean shear bond strength of each group was as follows: 10.07 ± 1.83 MPa in Group I, 7.62 ± 0.78 MPA in group II, 5.23 ± 0.78 MPa in group III. There were significant differences among all groups(p < 0.001). In conclusion, both aluminum chloride hemostatic agent and ferric sulfate hemostatic agent decreased the shear bond strength of RMGIC to dentin. And ferric sulfate hemostatic agent decreased the shear bond strength of RMGIC more than the aluminium chloride hemostatic agent.

Arterial Embolization as the Management of Massive Hemoptysis (대량 객혈 환자에서 동맥색전술의 지혈효과)

  • Kang, Jeong-Seong;Jung, Byung-Hak;Cho, Kyoo-Hye;Chang, Keun;Jeong, Eun-Taik;Roh, Byung-Suk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.2
    • /
    • pp.165-170
    • /
    • 1993
  • Background: Massive hemoptysis that may induce acute asphyxia can be a fatal problem. Bronchial arteries and other nonbronchial systemic arteries of lungs must be searched by angiography, because they are main source of hemoptysis. Arterial embolization is a well-accepted and widely used for management of massive hemoptysis. This study was designed to evaluate the effectiveness of this method. Method: Prospective analysis was done in 23 cases, that underwent arterial embolization from June 1990 to July 1992. Hemorrhaged arteries were embolized with Gelfoam particles. In cases with severe broad hemorrhagic findings, Coils were added to Gelfoam particles. And they were observed for 6 months at least. Results: Immediate cessation of hemoptysis was achieved in all cases. Recurrent hemoptysis was observed in 7 cases (30%). The patients with nonbronchial artery hemoptysis had increased tendency of recurrence (6/13) than only bronchial artery hemotysis (1/10). The 7 cases treated with Coils had not any recurrence. Conclusion: Arterial embolization in massive hemoptysis is a useful and safe procedure for immediate control. But, the patients with this procedure had a potentiality of recurrence. So diagnostic and therapeutic efforts for underlying causes should be performed.

  • PDF

Effect of Aluminum Chloride Hemostatic Agent on Bonding Strength of RMGIC in Primary Tooth (염화알루미늄 지혈제가 유치와 레진강화형 글라스아이오노머 시멘트의 결합강도에 미치는 영향)

  • Woo, Seung-Hee;Shin, Jisun;Lee, Joonhaeng;Han, Miran;Kim, Jong Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.4
    • /
    • pp.397-404
    • /
    • 2021
  • The purpose of this study was to evaluate the effect of a hemostatic agent containing aluminum chloride on the shear bond strength of resin-modified glass ionomer cement (RMGIC) to the dentin of primary teeth. Thirty-six extracted non-carious human primary teeth were collected in this study. Dentin surfaces were cut and polished. The specimens were randomly divided into 4 groups; group I: RMGIC without conditioning; group II: polyacrylic acid (PAA), RMGIC; group III: aluminum chloride, RMGIC; group IV: aluminum chloride, PAA, RMGIC. All teeth were thermocycled between 5.0℃ and 55.0℃ for 5000 cycles. Fifteen specimens from each group were subjected to shear bond strength test and 3 specimens from each group were inspected using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy. The mean shear bond strength of each group was as follows: 4.04 ± 0.88 MPa in group I, 8.29 ± 1.40 MPa in group II, 1.39 ± 0.47 MPa in group III, 6.24 ± 2.76 MPa in group IV. There were significant differences among all groups (p < 0.001). SEM image of the dentinal tubules were partially exposed in group III and group IV. Fully exposed dentinal tubules were found in group II. In conclusion, aluminum chloride decreased the shear bond strength of RMGIC to dentin, regardless of PAA conditioning.

Recent Progress in Mussel-inspired Catechol-conjugated Chitosan Hemostats (홍합 모사 카테콜기가 도입된 키토산 지혈제 연구 동향)

  • Seongyeon Jo;Soomi Kim;Chanwoo Park;Seungwon Hong;Hong Kee Kim;Ji Hyun Ryu
    • Journal of Adhesion and Interface
    • /
    • v.24 no.4
    • /
    • pp.113-119
    • /
    • 2023
  • Since it was reported that the unusual amino acid DOPA in synergy with lysine and histidine residues found in mussel adhesive proteins plays a pivotal role in mussel adhesion in underwater environments, there has been a burgeoning development of various catecholamines-based adhesives for biomedical applications. Among these, catechol-conjugated chitosan, containing catecholamine, featuring multiple catechol groups within its aminerich chitosan backbone, has found versatile utility in fields, such as tissue adhesion, wound dressing, tissue healing, hemostats, drug delivery systems, and tissue engineering scaffolds. Significantly, chitosan-catechol is a mussel-inspired material approved by both US Food and Drug Administration (FDA) and KR Ministry of Food and Drug Safety (MFDS) for its effectiveness in hemostasis. This review focuses on 1) general aspects of catechol-conjugated chitosan, highlighting catechol group integration into chitosan backbones, 2) examination of proposed mechanisms of hemostasis, and 3) exploration of diverse physical forms, including solution, hydrogels, patches, and thin films with practical applications inapplicable to hemostasis.

Venous Backflow in a Patent Polytetrafluoroethylene Arteriovenous Graft -A case report- (개존되어 있는 인조혈관(Polytetrafluorethylene)에 정맥성 역류 -1예 보고-)

  • Chon Soon-Ho
    • Journal of Chest Surgery
    • /
    • v.38 no.5 s.250
    • /
    • pp.389-390
    • /
    • 2005
  • We report a case of a 48-year-old woman with end-stage renal failure who had a Polytetrafluoroethylene graft for hemodialysis and who had developed complications of venous outflow stenosis and venous backflow. Although venous backflow is an harbinger of graft failure, it is not enough reason to abandon the graft immediately. The patient was able to utilize her graft for 6 further months.

Hemostasis of Anastomotic Site by Wrapping with Artificial Vascular Graft (대동맥 치환술시 인조혈관을 이용한 문합부 지혈)

  • 송상윤;장원채;나국주;김상형;안병희
    • Journal of Chest Surgery
    • /
    • v.34 no.8
    • /
    • pp.648-650
    • /
    • 2001
  • Bleeding from anastomotic site in operation for aorta has been troublesome, because it has influence on postoperative morbidity and mortality. Therefore, hemostasis is very important. We describe a simple and effective method for achieving hemostasis of the anastomotic site in aortic surgery. By wrapping around anastomotic site with remnant artificial vascular graft, we have acquired good results.

  • PDF

The influence of hemostatic agent contamination on bond strengths on dentin bonding agents (지혈제가 상아질과 레진 결합력에 미치는 영향)

  • Cho, Jeong-Hyun;Lee, Eun-Jeong;So, Kyung-Mo;Kim, Won;Oh, Nam-Sik;Han, Sang-Hyun;Song, Kyung-Hwa
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.351-358
    • /
    • 2008
  • Purpose: This study examined the recovery of the dentin-resin bonding strength, and the difference in the bonding strength after applying pH hemostatic agents at various pH. Materials and methods: Bosmin, Hemodent, Astregedent, and Visine were used as the hemostatic agents in this study. The Bosmin, Hemodent, and Astrigedent hemostatic agents are acidic, and the Visine hemostatic agent is neutral and is used as a decongestant. Ninety human molar teeth were used as the specimen. The teeth were sectioned using a diamond wheel until the dentin was exposed and wet ground by silica paper. The specimens were divided into two groups according to the hemostatic agent used. The specimens were then subdivided into 9 groups according to the application of re etching (R group) or rinsing only (N group). A commonly used resin bonding procedure was used in the control group. The resin bonding procedure was managed dentin using celluloid capsule. In addition, the shear bond strength was measured using an Instron. Results: In general, samples with the applied hemostatic agent, with the exception of Visine, had a slightly weak bond that was similar to the control group. In addition, the rinsing only (N) group had slightly weak bond that was similar to the re etching (R) group. Conclusion: The application of a hemostatic agent on the dentin surface does not affect the shear bond strength after application for a short time. In addition, rinsing only can recover the shear bond strength making other management procedures redundant, particularly re etching.

The Satisfaction Survey of Users and Patients on the Developed Disposable Tourniquet (개발한 일회용 지혈대의 사용자 및 환자 만족도 조사)

  • Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.615-622
    • /
    • 2016
  • The 18~20G needle is used to computer tomography (CT) contrast examination. Therefore, a patient has to apply a self-administering hemostasis (conventional method: CM) and often experience bleeding in the course. Thus, we developed the new disposable transparent tourniquet (TT) for reducing. This study was to compare the usefulness between the proposed transparent tourniquet and the existing hemostatic methods. A Satisfaction survey was conducted by 50 patients and 25nurses. The survey contained the satisfaction of the convenience, safety, sanitation, and wearing sensation of transparent tourniquet. We employed face-to-face interview on 5 points likert scales. And Chi-square, paired T-test were used for the statistics verification. As for the patients, the satisfaction levels were measured for each category with the gender, age. Patients evaluation, overall satisfaction high average sore used TT and there were statistical significance by paired T-test(p<0.05). The following is the average satisfaction level for each category: $4.4{\pm}0.53$ in; $4.28{\pm}0.57$ in safety; $4.52{\pm}0.54$ in sanitation; $4.16{\pm}0.54$ in wearing sensation. So the overall satisfaction level is measured at $4.34{\pm}0.51$. As for the nurses, CT work experience and the current satisfaction with tourniquet were counted as variables. The satisfaction level for each category is: $3.8{\pm}0.7$ in; $3.6{\pm}0.68$ in safety; $3.4{\pm}0.5$ in sanitation; $3.9{\pm}0.49$ in hemostasis. The overall satisfaction level is $3.8{\pm}0.3$. Patients' satisfaction levels were very high with little difference among variables. Nurses' satisfaction levels were different with the TT depending on their work experience but their overall satisfaction was high. This TT will be a starting point to minimizing patient's inconvenience and more studies are necessary to enhance their satisfaction.

Effects of Saury Meat on Antihyperlipidemic and Antiarteriosclerosis Activities in Sprague-Dawley Rats (꽁치육의 고지혈증 유발 쥐에서의 항고지혈증 및 항동맥경화증 효능)

  • Lee, Seung-Joo;Ha, Wang-Hyun;Choi, Hye-Jin;Cho, Soon-Yeong;Choi, Jong-Won
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.4
    • /
    • pp.531-537
    • /
    • 2011
  • The effects of dietary supplementation of pacific saury on anti-hyperlipidemic activities were investigated using an animal test study in which normal rats were fed four different parts of saury, such as the whole body, meat, internal organs, or a mixture of head, caudal fin, and bone. Serum total lipid and triglyceride levels were significantly (p<0.05) reduced in rats fed saury meat at a dose of 200 mg/kg of body weight compared to hyperlipidemic control rats. There were also significant decreases in serum total cholesterol and LDL-cholesterol levels in the rats fed saury meat at 200 mg/kg of body weight. In addition, the atheroscrelosis index and superoxide dismutase in blood lipids were significantly (p<0.05) lowered in rats fed saury meat at 200 mg/kg of body weight compared to the control rats. In conclusion, our results indicate that saury meat contains unknown physiologically active components as than compared to other parts of saury, and has potential for use in the prevention of hyperlipidemic arteriosclerosis.