• Title/Summary/Keyword: 지하철진동

Search Result 107, Processing Time 0.027 seconds

A Study on the Vibration Characteristics of Subway Structure by Train Load (열차 하중에 의한 지하철 구조물의 진동 특성에 관한 연구)

  • Park, Sung Woo;Park, Seung Su;Hwang, In Baek
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.4
    • /
    • pp.107-115
    • /
    • 2011
  • In this study, the vibration analysis of the underground box structures induced train movement is studied. In order to perform these analysis, dynamic data, which was measured when subway is in service, are gained by attaching accelerometers on the structure such as lower beam, lateral wall and upper slab. Also, accelerometers are attached on the lower beams and side walls of the gravel ballast and concrete ballast sections in order to compare vibration due to ballast materials. The vibration results of upper slabs and lower beams reveal that the vibration on the upper slabs is greater than the lower beams. Also, the results of the crack gauge on the upper slab show that crack width dose not change due to vibration, These means that the effect of the vibration on the structure is very limited. In order to evaluate the vibration of the structure, acceleration unit is converted to velocity unit comparing with the existing velocity data gained from the platforms.

Development and Shaking Table Tests of a Base Isolator for Controling Subway Train-Induced Vibration of a Steel Building (지하철 진동에 대한 철골건물 기초진동 절연장치의 개발 및 진동대 실험)

  • Kim, Jin-Koo;Song, Young-Hoon;Kwun, Hyong-Oh;Huh, Young
    • Journal of KSNVE
    • /
    • v.7 no.5
    • /
    • pp.789-796
    • /
    • 1997
  • In this study a conventional rubber mount and a new form of base isolator made of steel spring coated with natural and articial rubber were manufactured and tested on a shaking table to investigate the capacity of reducing the vertical vibration of a building induced by subway train. The model structure used in the test is a 1/4 scaled steel structure, and a white noise input and train vibration records were used to check the effectiveness of the isolators. According to the results all three types of isolators turned out to perform effectively in reducing the acceleration and the natural rubber-coated one is ranked best among the isolators. However the vertical displacement of the model is increased due to the instolation of the bearings, and the safty against the lateral load induced by earthquake ground motion should be provided to be able to apply the system to the real buildings.

  • PDF

Vibration Characteristic of Medium-rise Building by Bus and Subway-induced Vibration (버스와 지하철 진동에 대한 중층건물의 진동특성)

  • Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.4
    • /
    • pp.97-104
    • /
    • 2007
  • This paper is concerned with the vibration characteristics of medium-rise building, which severely vibrated by vehicles. The field vibration measurement was employed for finding the vibration source and vibration reducing method. Time domain data from measurements were also utilized for vibration characteristics, such as effect of buses and subways-induced vibration on the floor vibration of the building. effectiveness of the vibration reducing method was also demonstrated.

  • PDF

The Effects of the Wave Propagation Path of Ground Vibration Induced by the Subway Train on the Reduction of Vibration Level (지하철 주변 지반진동의 전파경로가 진동레벨 감쇠에 미치는 영향)

  • Shin, Han-Chul;Cho, Sun-Kyu;Yang, Shin-Chu;Lee, Jong-Min
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.631-640
    • /
    • 2009
  • In this paper, Numerical analysis was conducted to study on the reduction of ground vibration level induced by subway train. The analytical results indicated that the soil properties were the predominant factor affecting the ground vibration when the tunnel was located in the soil layer. On the other hand, the rock properties were the predominant one when the tunnel was located in the rock layer. The effects of the angle between the vertical line of vibration source and the receive point on the reduction of vibration level were also evaluated. There were little difference in the reduction of vibration level when the receive point was located within $30^{\circ}$. The vibration level, however, rapidly decreased when the angle between the two points was larger than $40^{\circ}$.

Excavation Design and Vibration Analysis for the Crossing Under a Railway Station (정거장 구조물 횡단 굴착 설계 및 진동 해석)

  • ;;Reijo Riekkola
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.505-512
    • /
    • 1998
  • 지하철과 같은 지하구조물 설계시 기존 구조물 지하를 관통하는 경우가 있다. 본 논문은 기존 역사의 바닥슬래브 밑에 새로운 지하철용 박스 구조물 상부 슬래브가 위치하게 되는 특별한 경우의 굴착 방법을 제시하고 제시된 굴착방법이 상부 구조물에 어떤 영향을 미치는지를 FLAC을 이용하여 검토해 본 것이다. 기존 구조물이 위치하고 있는 지반이 경암인 경우 발파가 주의 깊게 설계되고 시행된다면 발파로 인한 상부 구조의 진동 영향은 충분히 제어할 수 있는 수준으로 예상되었다.

  • PDF

An Experimental Study on the Squeal Noise for Subway (지하철 스퀼소음에 대한 실험적 연구)

  • 문경호;유원희;김재철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.536-541
    • /
    • 2003
  • When a rail vehicle transverses tight curves, it often emits an intense, high-pitched squeal. This squeal has always been noticed as one of the most disturbing noise sources of railway systems. At present, w cannot predicted squeal noise that is influenced by a large number of dependent parameters. In this study, we performed structural analysis to find out the frequency of the wheel and measured squeal noise at Seoul subway. We also tested reduction effectiveness of squeal noise through rail lubricator

  • PDF

Evaluation of the blast-restriction zone to secure tunnel lining safety (터널라이닝 안전관리를 위한 발파제한영역 평가)

  • Shin, Jong-Ho;Moon, Hoon-Ki;Choi, Kyu-Cheol;Kim, Tae-Kyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.1
    • /
    • pp.85-95
    • /
    • 2009
  • In urban areas, blast excavation adjacent to tunnels is carried out frequently. It is generally required to secure static and dynamic stability of nearby tunnel structures for any such activities. Although there is some national guidelines for static safety, there is little guides to risk zoning controling the dynamic behavior of the underground structures. In this study, impacts on the blast-induced vibration are investigated using numerical study. An attempt to define the restricted area of blast adjacent to subway tunnels was also made. Particular concerns were given to tunnel depth and ground types. By carrying out the parametric study on depth and ground patterns, the envelope of blast distance of which dynamic response on the lining is controlled under 1 cm/sec, is established. It is shown that the increase in depth has increased the required safety distance slightly until the distance of 3.5 times of the tunnel diameter. Despite small changes in safety distance, it can be generally said that the effects of depth and stiffness of the ground is not significant in controlling the particle velocity of the tunnel linings.

Structure movement-coping Waterproofing technology application for Railroad facilities (철도시설에 있어서의 구조물 거동대응형 방수기술의 적용)

  • Cho, Il-Kyu;Lee, Jong-Yong;Oh, Sang-Keun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1964-1969
    • /
    • 2010
  • Recently, as construction market scale is getting bigger and transportation industry is developing, the underground structure construction such as subway, tunnel (excavation box) or shield tunnel structure is becoming more diverse, and its demand is gradually increasing. However, for the concrete structures constructed underground, the water leakage is occurred due to the expansion joint and construction joint, or movement, uneven settlement, excessive load and vibration during application causing cracks. Many waterproofing method and materials are used in jobsites, but areas such as underground railroad and subway that has movement and vibration at all times, the ability of waterproofing layer is declined causing repetitive water leakage due to crack, erosion and separation, which is a vicious cycle. Therefore, this study evaluates the responsiveness to a movement for adhesive/flexible waterproofing material that can cope with the vibration and the movement of the structure. Also to recommend a waterproofing technology that can cope with structure movement through examples of actual jobsite applications such as subway and tunnel where there are constant movement and vibration.

  • PDF

Actual Noise Condition of the Subway Station in Gwang-ju City (광주광역시 지하철 소음실태 조사연구)

  • Kim, Heung-Sik;Park, Gi-Pyo;Shin, Seung-Hun;Lee, Min-Tae;Moon, Gyeong-Dong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.934-937
    • /
    • 2004
  • The purpose of this study is to present a fundamental data to get the noise reduction method of subway station in Gwang-ju city. Subway noise level measurement and questionnaire on the satisfaction of sound condition were carried out. The results show that the noise level of the subway station and the noise reduction effect installed by screen door is over 10 dB(A).

  • PDF