• Title/Summary/Keyword: 지하저장탱크

Search Result 70, Processing Time 0.024 seconds

Experimental Analysis of Corbel Part Behaviour in Inground LNG Storage Tank (지하식 저장탱크 Corbel부 실험적 거동 분석)

  • Yoon I.S.;Kim J.K.;Kim Y.K.;Kim J.H.
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.1 s.30
    • /
    • pp.56-60
    • /
    • 2006
  • The connection part (corbel) between bottom slab and side wall in inground LNG storage tank has hinge conditions partly fixed by using anchor bars to reduce stress concentration. The corbel deforms in both radial and vertical directions under load conditions of the LNG tank such as LNG temperature, hydraulic pressure, etc. Membrane is an important part from the viewpoint of design because the deformation of the corbel is transformed directly to the membrane and superposed with other deformations. Behavior of the corbel has been investigated through various sensors to measure temperature, load and displacement. And the test data have been compared with finite element results analysis to propose a more reasonable design of LNG storage tank.

  • PDF

매몰저장탱크 검사방법 개선 건의

  • Korea LPGas Industry Association
    • LP가스
    • /
    • s.87
    • /
    • pp.13-14
    • /
    • 2003
  • 주지하시는 바와 같이 2001.7.29부터 15년이상 경과된 지하매몰LPG저장탱크는 주위의 모래를 제거한후 피복을 벗겨 탱크외면검사를 하도록 고시(산자부고시 제2001-12호, 2001.1.29)가 개정된 바 있습니다. 그러나 이러한 검사방법은 여러 가지 문제점이 있어 저희 협회는 그동안 몇차례 이에대한 개선을 요청한 바 있으며, 실제로 탱크 외면의 모래를 제거한 후 검사를 실시한 결과 우려하였던 여러 문제점이 사실로 확인되었기에 첨부와 같이 매몰저장탱크의 재검사방법을 개선해 줄 것을 요청드리오니 긍정적으로 검토.반영하여 주시기 바랍니다.

  • PDF

Status and Prospect of Site Welding Technology for LNG Strorage Tank (LNG 저장탱크의 현장용접 시공기술의 현상 및 전망)

  • 이광희;전혁성
    • Journal of Welding and Joining
    • /
    • v.13 no.3
    • /
    • pp.8-17
    • /
    • 1995
  • LNG를 저장할 수 있는 탱크는 주로 지상식이거나 반지하식이며 그 용량은 매우 다양하다. 우리나라에서는 지상식 탱크가 평택 인수기지에 10만m$^{3}$급 Membrane Type 6기가 건설되었고 1기는 거의 완성단계이며, 현재 추가로 건설 중인 3기를 포함하면 총 10기의 탱크를 확보하게 된다. 또한 제2인수기지인 인천에도 동급 으로서 9%Ni강을 사용하는 Double Wall Type LNG 탱크 3기를 건설 중이다. 전세계적 으로 볼 때 LNG 저장 탱크의 78%는 지상식으로 Double Wall Type 또는 Membrane 저장 탱크 형식을 취하고 있으나, 최근에는 안전성 측면, 토지 가격의 상승, 토지의 합리적 이용 측면 등을 감안하여 LNG 탱크를 지하화, 대형화하는 추세이다. 본고에서는 Fig. 1과 같은 구조의 Double Wall Type LNG 저장탱크 중 초저온의 LNG에 직접 접하는 저 온용 재료(9%니켈강)로 만들어지는 내조 용접에 대해서 중점적으로 논하기로 하며, 특히 9% 니켈강 Shell Plate Horizontal Joint에 채용되는 Automatic Submerged ARC 용접에 대해 실제 현장 용접 시공상태를 나타내고자 한다.

  • PDF

Development of Slurrystore System with Enamel Ware. (법랑을 이용한 음식물 쓰레기 및 퇴비 발효조 개발)

  • 한두희
    • Proceedings of the KAIS Fall Conference
    • /
    • 2003.06a
    • /
    • pp.353-355
    • /
    • 2003
  • 일반직으로 액비 탱크 등은 콘크리트를 이용하여 지하에 시공하므로 빗물 등이 흘러 들어가기 쉽고, 습기등에 의하여 콘크리트가 부식되기 쉬우며 이로 인하여 오폐수가 지하로 스며들어 지하수를 오염시킬 수 있다. 이를 해결하기 위하여 액비탱크를 법랑을 이용하여 지상에 건설하여 침출수를 원천적으로 방지하고 미려한 색상으로 인한 자연 친화적인 저장 장치를 활용하여, 지하에 일시 저장한 분뇨를 펌프를 사용하여 지상으로 끌어 올려 숙성 발효시키면 우수한 액비를 생산 활용할 수 있다.

  • PDF

A Study on the Optimized Installation of Gas Storage Tank through Pugh Method (퓨 방법을 통한 최적의 저장탱크 시공에 관한 연구)

  • Huh, Yong Jeong;Lee, Jong Rark;Lee, Seon Yeong;Leem, Sa Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.8-12
    • /
    • 2014
  • The aim of this study is achieving customer satisfaction by finding cost-effective installation of storage tanks in the gas filling stations. Pros and cons were measured by comparison between above and underground tanks using Pugh methods. In particular, severe problems regarding gas safety are expected to be resolved by reducing the frequency of gas accidents occurred in mass storage facilities. To this end, we have used Pugh's method to compare the advantages and disadvantages of the existing storage tanks-Ground above type and underground type. After the analyses, it is shown that underground containment storage tank can provide the highest degree of safety and Real estate among Ground above type, Underground buried type and underground containment type storage tanks.

An Experimental Study on the Emission Characteristics of VOCs Generation from Automotive Fuel Tank at Gasoline Reservoir (주유소에서 자동차 주유시 발생하는 VOCs 배출특성에 관한 조사연구)

  • 김기선;배성근;윤성렬;이원수;선우영;홍지형
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.91-92
    • /
    • 2003
  • 경제성장 및 산업의 고도화에 따른 자동차 보급의 증가, 유류 및 유기용제의 사용량 증가로 휘발성유기화합물질(Volatile Organic Compounds; 이하 VOCs)의 배출량이 증가하고 있다. 이러한 VOCs의 배출원중에 하나가 주유소에서 발생하는 VOCs이다(정일록 등, 1995). 주유소에서의 VOCs 배출원은 EPAAP-42의 경우 지하저장탱크 숨구멍을 통한 증발과 유조차에서 지하 저장탱크에 휘발유 등 석유 제품을 하역시 증발을 Stage I, 지하저장에서 자동차에 주유시 증발 및 주유시 흘림에 의한 VOCs 증발을 Stage II로 구분되어 있다. (중략)

  • PDF

주유소 인근 토양의 유류 오염도 조사

  • 이주광;강희만;이용은;권수열;고석오
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.156-159
    • /
    • 2001
  • 지하저장탱크가 설치된 지 20년 이상 경과된 D주유소를 대상으로 14개의 지점에 대한 토양 및 지하수 오염도 조사를 실시하였다. 현장의 토양이나 지하수는 저장탱크나 주유기로부터 거리에 따라 다소 차이가 있었으나 불포화 층에 Free Liquid 상태의 유류가 존재할 정도로 상당히 오염되어 있다는 것을 확인하였으며, 본 대상지역의 오염원은 가솔린보다는 디젤에 의해 더 심하게 오염된 것으로 조사되었다.

  • PDF

The Method of Thermal Crack Control about the LNG Tank Wall in Winter (LNG 저장탱크 벽체의 동절기 온도균열제어 방안)

  • Son, Young-Jun;Ha, Jae-Dam;Um, Tai-Sun;Lee, Jong-Ryul;Baek, Seung-Jun;Park, Chan-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.637-640
    • /
    • 2008
  • Since the first underground LNG tank was constructed in Incheon, continuously many LNG tanks were constructed in Tongyoung and Pyongtaek. The storage capacity of LNG tank increased by 200,000kl and the structure size and the concrete mixing design has changed. The crack of concrete induced by the heat of hydration is a serious problem, particularly in massive concrete structures. In order to control the thermal crack of massive concrete, the low heat portland cement(type Ⅳ) is applied to bottom annular part, bottom central part, lower walls and ring beam. In this study, in order to thermal crack control about the LNG tank wall(lot 8 of #16 Pyongtaek LNG tank) in winter, analysed the concrete temperature, the extention of term, the curing condition and the concrete mixing design. When the concrete mixing design is changed from OPC+FA25% to LHC+FA25%, the thermal crack index is 1.33 and satisfied with construction specifications(over 1.2).

  • PDF