• Title/Summary/Keyword: 지하역사

Search Result 228, Processing Time 0.027 seconds

Indoor Radon Risk Assessment by Applying Measurement Concentrations and Exposure Times for Military Facilities and Underground Shopping Malls near Subway stations (군부대 시설 및 지하철 역사 주변 지하상가의 측정농도와 노출시간을 이용한 실내에서의 라돈 위해성 평가)

  • Kong, Jin Seok;Kim, Younghee
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.5
    • /
    • pp.345-351
    • /
    • 2016
  • Objectives: The objective of this study was to conduct risk assessment using indoor radon concentration and exposure times. Methods: The target facilities were military facilities before and after the application of radon reduction processes and underground commercial facilities in major subway stations in Seoul. Indoor radon concentrations were measured by passive sampler. Results: Radon concentrations in 13 military facilities were initially higher than the guidelines, but the levels were below guidelines after the application of radon reduction processes. Underground shopping mall radon concentrations near subway stations in Seoul satisfied the guidelines. However, indoor radon effective doses after radon reduction processes in some military facilities and those in underground shopping malls belonged to International Commission on Radiological Protection (ICRP) groups needing control management. Conclusion: Indoor radon management requires risk assessment data that takes into account working time (or residence time) in addition to management according to concentration guidelines.

GIS Application to Urban Hydrogeological Analysis of Groundwater System in Seoul Area (서울지역 지하수시스템의 수문지질학적 특성 분석을 위한 지리정보시스템의 활용)

  • 김윤영;이강근
    • Spatial Information Research
    • /
    • v.7 no.1
    • /
    • pp.103-117
    • /
    • 1999
  • During the last several years, the geographic information system(GIS) technology has emerged as a very effective tool for analyzing complicated groundwater system Linking GIS to spatially distributed hydrogeological data and groundwater models offers many advantages in the analysis of urban groundwater system. This paper describes the urban hydrogeological application of GIS in Seoul area. This study constructs an urban hydrogeological database via pre- and post-processing of various types of urban hydrogeological data, such as groundwater-level fluctuation, topogaphic data, water chemistry data, subway pimping station data, tidal effect of the Han River, and hydrogeological parameters. A hydrogeological model has been designed to enable importing data from the database and providing the model output for the repetitive manipulation and display in GIS.

  • PDF

Study on Particulate Pollutant Reduction Characteristics of Vegetation Biofilters in Underground Subway Stations (지하역사내 식생바이오필터의 입자상 오염물질 저감특성 연구)

  • Kim, Tae Han;Oh, Ji Eun;Kim, Mi Ju
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.4
    • /
    • pp.99-105
    • /
    • 2022
  • Public attention to the indoor environment of underground subway stations, which is a representative multi-use facility, has been increasing along with the increase in indoor activities. In underground stations, fine iron oxide, which affects the health of users, is generated because of the friction between wheels and rails. Among particulate pollutant reduction technologies, plants have been considered as a non-chemical air purification method, and their effects in reducing certain chemical species have been identified in previous studies. The present study aimed to derive the total quantitative and qualitative reduction effects of a bio-filter system comprising air purifying plants, installed in an underground subway station. The experiment proceeded in two ways. First, PM(particulate matter) reduction effect by vegetation biofilter was monitored with the IAQ(indoor air quality) station. In addition, chemical speciation analysis conducted on the samples collected from the experimental and control areas where plants and irrigation using SEM-EDS(scanning electron microscopy-energy dispersive X-ray spectroscopy). This study confirmed the effect of the vegetation bio-filter system in reducing the accumulation of particulate pollutants and transition and other metals that are harmful to the human body.

Characteristic Assessment of Heavy Metals in Dusts Collected by the Air Filtration System at Subway Stations in Daegu, Korea (대구지역 지하철역사 공기여과필터 포집먼지에 함유된 중금속성분의 특성평가)

  • Do, Hwa-Seok;Song, Hee-Bong;Shin, Dong-Chan;Kwak, Jin-Hee;Lee, Myoung-Sook;Yoon, Ho-Suk;Kang, Hye-Jung;Phee, Young-Gyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.42-50
    • /
    • 2009
  • Samples of subway dust were collected by the air filter system of 30 subway stations on Daegu subway line 1 in January 2008. Samples were sieved below 100 ${\mu}m$, and 14 elements were analyzed using ICP after acid extraction. Results obtained from the source assessment of trace elements using enrichment factor showed that Ca, Fe, K, Mg, Mn, Na, V were influenced by natural sources such as weathered rock and resuspended soil, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources such as fuel combustion and waste incineration. Concentrations were remarkably higher in components from natural sources than in components from anthropogenic sources. Anthropogenic sources were significantly affected by indoor dusts than outdoor dusts. Results of pollution indices of heavy metals indicated that indoor dusts were more contaminated with heavy metal ions than outdoor dusts. The correlation analysis among trace elements indicated that components were much correlated in the order of natural sources-anthropogenic sources, anthropogenic sources-anthropogenic sources, natural sources-natural sources in both indoor and outdoor dusts. Trace element components of outdoor dusts were largely correlated than those of indoor dusts. In addition, indoor dusts were significantly affected by outdoor dusts rather than depth from the surface or the average daily number of subway passengers.

Three dimensional GPR survey for the exploration of old remains at Buyeo area (부여지역 유적지 발굴을 위한 3차원 GPR 탐사)

  • Kim Jung-Bo;Son Jeong-Sul;Yi Myeong-Jong;Lim Seong-Keun;Cho Seong-Jun;Jeong Ji-Min;Park Sam-Gyu
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.49-69
    • /
    • 2004
  • One of the important roles of geophysical exploration in archeological survey may be to provide the subsurface information for effective and systematic excavations of historical remains. Ground Penetrating Radar (GPA) can give us images of shallow subsurface structure with high resolution and is regarded as a useful and important technology in archeological exploration. Since the buried cultural relics are the three-dimensional (3-D) objects in nature, the 3-D or areal survey is more desirable in archeological exploration. 3-D GPR survey based on the very dense data in principle, however, might need much higher cost and longer time of exploration than the other geophysical methods, thus it could have not been applied to the wide area exploration as one of routine procedures. Therefore, it is important to develop an effective way of 3-D GPR survey. In this study, we applied 3-D GPR method to investigate the possible historical remains of Baekje Kingdom at Gatap-Ri, Buyeo city, prior to the excavation. The principal purpose of the investigation was to provide the subsurface images of high resolution for the excavation of the surveyed area. Besides this, another purpose was to investigate the applicability and effectiveness of the continuous data acquisition system which was newly devised for the archeological investigation. The system consists of two sets of GPR antennas and the precise measurement device tracking the path of GPR antenna movement automatically and continuously Besides this hardware system, we adopted a concept of data acquisition that the data were acquired arbitrary not along the pre-established profile lines, because establishing the many profile lines itself would make the field work much longer, which results in the higher cost of field work. Owing to the newly devised system, we could acquire 3-D GPR data of an wide area over about $17,000 m^2$ as a result of the just two-days field work. Although the 3-D GPR data were gathered randomly not along the pre-established profile lines, we could have the 3-D images with high resolution showing many distinctive anomalies which could be interpreted as old agricultural lands, waterways, and artificial structures or remains. This case history led us to the conclusion that 3-D GPR method can be used easily not only to examine a small anomalous area but also to investigate the wider region of archeological interests. We expect that the 3-D GPR method will be applied as a one of standard exploration procedures to the exploration of historical remains in Korea in the near future.

  • PDF

A Study on Conservation and Management of the Joseon Royal Tomb's System - Focused on Joseon Royal Tombs Under the Eastern District Management Office - (조선왕릉의 능제보존관리에 관한 연구 - 동부지구관리소 산하 조선왕릉을 중심으로 -)

  • Choi, Jong-Hee;Lee, Chang-Hwan;Hwang, Kyu-Man;Kim, Kyu-Yeon
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.36 no.3
    • /
    • pp.75-87
    • /
    • 2018
  • The purpose of this study is to investigate conservation and management methods of the Joseon Royal Tombs under the Eastern District Management Office. Through the literature survey, we understood the process of change of Joseon royal tombs, and through field surveys and interviews, we understood the status of the interior and the surrounding area. In this process, topography, land use and flow of human traffic, architecture and stone objects, water system, historical forests, and facilities were set as the main evaluation indicators. Urbanization has damaged the original terrains of Royal Tombs as national roads, buildings and facilities have constructed in the inner and outer area of Joseon Royal Tombs. Construction of underground passage, land purchase, relocation and demolition of the buildings are required for the conservation of the Royal Tombs area, and then it is necessary to recover the original terrain. In the case of land use and pathways, there are many disconnection of the original ritual circulation, they should be maintained to remind the sacred atmosphere of the royal tomb. And It is necessary to collect accurate information on the lost buildings and stoneworks through literature survey and excavation investigation, and that investigations should be lead to the exposure or restoration of the ruins. Historical forests require periodic and ongoing monitoring and management, and it is necessary to establish new entrance area and appropriate facilities following the long-Term conservation and management plan. These plans should be classified into short, medium and long-Term projects according to urgency and securing financial resources with a long perspective to implement continuous and systematic projects.

A Study on the Meaning of Geometric Analysis of Gameun Temple's Taegeuk Shapes (감은사 태극문양의 기하학적 의미 연구)

  • Kim, Il-Hwan;Park, Tae-Bong
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.6
    • /
    • pp.435-444
    • /
    • 2021
  • This paper discusses the geometrical interpretation of the Taegeuk Shapes of Kameun Temple through the geometric analysis of mathematics. Based on the literature, This paper attempted to clarify that the origin of Gameunsa's founding of the spirit of patriotism may coincide with historical records through historical literature and geometric meaning. First, the background of the founding of Kameun temple, geographical location located near the East Sea, especially the history of the ancient Chinese mathematics at the time, And that mathematical knowledge influenced all fields such as agriculture, architecture, and art. Secondly, it is related to the historical record as the space of about 60 centimeters, which is uniquely underground, was identified as the structure of the excavated space. It is thought that there is a strong correlation with the origin that the King Munmu changed into a dragon, and set up the temple to be able to stay. Based on these, the clues of the interpretation of the taegeuk and the triangular pattern were searched in the samcheon yanggi(參天兩地) of the Oriental and circumference of the Western. The taegeuk and triangular patterns represent the symbols of yin-yang harmony, which correspond to the origin of its creation. the Korean people regarded the mysterious dragon as a symbol of yinyang harmony. In conclusion the Shapes of Kameun temple's stone is consistent with the contents mentioned in the historical record.

A study on the Project Planning Method of Areas near St.Pancars Station & King's Cross Station in London (런던 St.Pancars Station & King's Cross Station 인접지역의 철도역사 기반 도시재생계획에 관한 연구)

  • Shin, Ye-Kyeong
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.6 no.10
    • /
    • pp.603-612
    • /
    • 2016
  • This study will observe the following subjects based on the railroad: First, the development of St. Pancreas Station, which is the gateway to London from other Europe continent, and King's Cross Station, which connects all the intercity within London. Second, the planning characteristic of urban regeneration case which was driven from Camden district, the center of King's Cross Central, which is located in between the two stations, St. Pancreas and King's Cross. Third, based on the the two stations and urban regeneration, this study attempts to investigate the direction of urban regenerating plan and its detailed strategy. As a result, King's Cross Station, St. Pancreas Station and the King's Cross Central area, which is an adjacent area from the two stations, were a slum for a long time. However, the two close stations played a role as the United Kindom and London's railroad network by sharing the common denominator of having the international high-speed railway among the Europe continent and being the connection of National railroads within London. Eventually, based on such potential of railroad traffic, King's Cross Central area was newly regenerated. The consequence of this study has shown that not only the physical modernization of buildings, implementation of compact railroad network supporting both ground and underground of each area or traffic connection was organized in London, but also secured the pedestrian way for easier transfer and planned and allocated facilities by considering citizen's publicness and multilateral use.

Large-scale, Miocene Mud Intrusion into the Overlying Pleistocene Coastal Sediment, Pohang City, SE Korea: Deformation Mechanism, Trigger, and Paleo-seismological Implication for the 2017 Pohang Earthquakes

  • Gihm, Yong Sik;Ko, Kyoungtae;Choi, Jin-Hyuk;Choi, Sung-ja
    • Economic and Environmental Geology
    • /
    • v.53 no.5
    • /
    • pp.585-596
    • /
    • 2020
  • The 2017 Pohang Earthquakes occurred near a drill site in the Pohang Enhanced Geothermal System. Water injected for well stimulation was believed to have reactivated the buried near-critically stressed Miocene faults by the accumulation of the Quaternary tectonic strain. However, surface expressions of the Quaternary tectonic activity had not been reported near the epicenter of the earthquakes before the site construction. Unusual, large-scale water-escaped structures were identified 4 km away from the epicenter during a post-seismic investigation. The water-escaped structures comprise Miocene mudstones injected into overlying Pleistocene coastal sediments that formed during Marine Isotope Stage 5. This indicates the vulnerable state of the mudstones long after deposition, resulted from the combined effects of rapid tectonic uplift (before significant diagenesis) and the development of an aquifer at their unconformable interface of the mudstone. Based on the detailed field analysis and consideration of all possible endogenic triggers, we interpreted the structures to have been formed by elevated pore pressures in the mudstones (thixotropy), triggered by cyclic ground motion during the earthquakes. This interpretation is strengthened by the presence of faults 400 m from the study area, which cut unconsolidated coastal sediment deposited after Marine Isotope Stage 5. Geological context, including high rates of tectonic uplift in SE Korea, paleo-seismological research on Quaternary faults near the study area, and historical records of paleoearthquakes in SE Korea, also support the interpretation. Thus, epicenter and surrounding areas of the 2017 Pohang Earthquake are considered as a paleoseismologically active area, and the causative fault of the 2017 Pohang Earthquakes was expected to be nearly critical state.

Compensation of Light Scattering Method for Real-Time Monitoring of Particulate Matters in Subway Stations (지하역사 내 미세먼지 실시간 모니터링을 위한 광산란법 보정)

  • Kim, Seo-Jin;Kang, Ho-Seong;Son, Youn-Suk;Yoon, Sang-Lyeor;Kim, Jo-Chun;Kim, Gyu-Sik;Kim, In-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.5
    • /
    • pp.533-542
    • /
    • 2010
  • The $PM_{10}$ concentrations in the underground should be monitored for the health of commuters on the underground subway system. Seoul Metro and Seoul Metropolitan Rapid Transit Corporation are measuring several air pollutants regularly. As for the measurement of $PM_{10}$ concentrations, instruments based on $\beta$-ray absorption method and gravimetric methods are being used. But the instruments using gravimetric method give us 20-hour-average data and the $\beta$-ray instruments can measure the $PM_{10}$ concentration every one hour. In order to keep the $PM_{10}$ concentrations under a healthy condition, the air quality of the underground platform and tunnels should be monitored and controlled continuously. The $PM_{10}$ instruments using light scattering method can measure the $PM_{10}$ concentrations every less than one minute. However, the reliability of the instruments using light scattering method is still not proved. The purpose of this work is to study the reliability of the instruments using light scattering method to measure the $PM_{10}$ concentrations continuously in the underground platforms. One instrument using $\beta$-ray absorption method and two different instruments using light scattering method (LSM1, LSM2) were placed at the platform of the Jegi station of Seoul metro line Number 1 for 10 days. The correlation between the $\beta$-ray instrument and the LSM2 ($r^2$=0.732) was higher than that between the $\beta$-ray instrument and the LSM1 ($r^2$=0.393). Thus the LSM2 was chosen for further analysis. Three different regression analysis methods were tested: Linear regression analysis, Nonlinear regression analysis and Orthogonal regression analysis. When the instruments using light scattering method were used, the data measured these instruments have to be converted to actual $PM_{10}$ concentrations using some factors. With these analyses, the factors could be calculated successfully as linear and nonlinear forms with respect to the data. And the orthogonal regression analysis was performed better than the ordinary least squares method by 28.45% reduction of RMSE. These findings propose that the instruments using light scattering method light scattering method can be used to measure and control the $PM_{10}$ concentrations of the underground subway stations.