• Title/Summary/Keyword: 지하수 이용특성

Search Result 902, Processing Time 0.032 seconds

Preparation of Anion Exchange Membranes for Electrodialysis by Impregnating Porous Polyethylene Films with Crosslinked Poly(vinylbenzyl ammonium chloride)s (다공성 폴리에틸렌 필름에 가교된 poly(vinylbenzyl ammonium chloride)를 충진한 전기투석용 음이온 교환 복합막의 제조)

  • Kim, Jeong-Hoon;Lee, Jung-Soo;Yoo, Min-Chul;Chang, Bong-Jun;Kang, Ho;Lee, Soo-Bok
    • Membrane Journal
    • /
    • v.18 no.2
    • /
    • pp.138-145
    • /
    • 2008
  • A series of anion exchange composite membranes were prepared and characterized for electro-dialysis process used in the removal of toxic anion and cation polutants in groundwater or wastewater. The membranes were prepared as follows; first, porous poly(ethylene) (PE) substrates were fully impregnated with monomer mixtures with various ratio of vinylbenzylchloride (VBC), divinylbenzene (DVB) and ${\alpha},\;{\alpha}$-azobis(isobutyronitrile) (AIBN). Second, they were thermally polymerized to yield crosslinked poly(VBC-DVB)/PE composite membranes. Finally, the membranes were treated in trimethylamine (TMA)/acetone to give $-N^+(CH_3)_3$-containing poly(VBC-DVB)/PE membranes. The basic membrane properties such as ion exchange capacity (IEC), electric resistance and water content of the resulting membranes were measured as a function of VBC/DVB and TMA/Acetone content. As a result, the composite membranes showed lower electric resistance, lower water content and higher IEC than commercial anion exchange membranes (AMX, Astom) due to thin PE substrates, indicating that the composite membranes could be successfully applied to the electrodialysis for water treatment.

Experimental Study of Freshwater Discharge and Saltwater Intrusion Control in Coastal Aquifer (해안대수층에서 담수-염수 경계면 변화에 따른 최대담수양수량과 염수침투제어에 대한 실험적 연구)

  • Suh, Seong-Kook;Oh, Chang-Moo;Kim, Won-Il;Ho, Jung-Seok
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.5
    • /
    • pp.159-168
    • /
    • 2010
  • This study investigates the relationships between the maximum freshwater pumping discharge and hydraulic properties of coastal aquifer using a laboratory model. The experiment performed the fresh pumping test in various locations near the saltwedge induced by saltwater intrusion to freshwater over aquifer characteristics of hydraulic conductivity, salinity, and ground surface slope. Saltwater pumping also tested to protest saltwater intrusion to the excessively discharging freshwater well. The maximum freshwater discharges were achieved, and then the optimum saltwater discharges were measured. It is found that greater hydraulic conductivity and ground surface slope produced greater the maximum freshwater pumping discharge. Salinity gave less impact on the pumping discharge relatively. Higher freshwater discharge was found at higher hydraulic conductivity and steeper ground surface slope. The optimum saltwater discharge required 14% more pumping rate than the maximum freshwater discharge to keep saltwater intrusion to the freshwater pumping well. Pumping well located closer to salt-wedge profile promoted less freshwater pumping discharge. Therefore, pumping well location, hydraulic conductivity, ground surface slope, and salinity should be taken into account in freshwater pumping in coastal aquifer.

Rainfall Partitioning in a Small Catchment of a Monogenetic Volcano in Jeju Island: Case Study on Eoseungsaeng-oreum of Mount Halla (제주도 단성화산 소유역에서의 강우의 분배 - 한라산 어승생오름을 사례로 -)

  • An, Jung-Gi;Kim, Tae-Ho
    • Journal of the Korean association of regional geographers
    • /
    • v.14 no.3
    • /
    • pp.212-223
    • /
    • 2008
  • The rainfall partitioning in a monogenetic volcano has been analysed using the hydrological data of a small catchment on Eoseungsaeng-oreum of Mount Halla and the meterological data of Eorimok Automated Weather System. The experimental catchment extends from 965 m to 1,169 m in altitude, and has an catchment area of $51,000\;m^2$ Eoseungsaeng-oreum is the scoria cone predominantly covered with Carpinus laxiflora and Quercus serrata. The analyzed periods are April 30 to September 12 and October 7 to November 19, 2007. The experimental catchment exhibits the total precipitation of 2,296.5 mm. Surface runoff amounts to 465 mm that is equivalent to 20.2% of the precipitation. By contrast, evapotranspiration accounts for 25.9% of the precipitation, and the remnant of 1,236.5 mm deep1y percolates underground through a basement. The rainy summer season, in particular, shows the highest deep percolation ratio of 62.2%. The deep percolation ratio of the experimental catchment is at 1east more two times than the ratio of a gneiss basin in Korea Peninsular. It has suggested that the experimental catchment is characterized by the higher portion of deep percolation in rainfall partitioning which reflects the highly permeable lithology in Jeju Island.

  • PDF

Geotechnical Characteristics of Prefabricated Vertical Drain System for Contaminated Soil Remediation (오염토양 복원을 위한 연직배수시스템의 지반공학적 특성)

  • Shin, Eunchul;Park, Jeongjun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.5
    • /
    • pp.5-14
    • /
    • 2007
  • The quantity of noxious wastes generated by the growth in industrialization and population in all over the world and its potential hazards in subsurface environments are becoming increasingly significant. The extraction of the contaminant from the soil and movement of the water are restricted due to the low permeability and adsorption characteristics of the reclaimed soils. Incorporated technique with PVDs have been used for dewatering from fine-grained soils for the purpose of ground improvement by means of soil flushing and soil vapor extraction systems. This paper is to evaluate several key parameters that affected to the performance of the PVDs specifically with regard to: well resistance of PVD, zone of influence, and smear effects. In the feasibility of contaminant remediation was evaluated in pilot-scale laboratory experiments. Well resistance is affected on the vertical discharge capacity of the PVDs under the various vacuum pressures. The discharge capacity increases consistently in areal extents with higher applied vacuum up to a limiting vacuum pressure. The head values for each piezometer at different vacuum pressures show that the largest head loss occurs within 14 cm of the PVD. Air flow rates and head losses were measured for the PVD placed in the model test box and the gas permeability of the silty soils was calculated. Increasing the equivalent diameter results in a decrease in the calculated gas permeability. It is concluded that the gas permeability determined over the 1,500 to 2,000 $cm^3/s$ flow rates are the most accurate values which yields gas permeability of about 3.152 Darcy.

  • PDF

Status of Underground Thermal Energy Storage as Shallow Geothermal Energy (천부 지열에너지로서의 지하 열에너지 저장 기술 동향)

  • Shim, Byoung-Ohan;Lee, Chol-Woo
    • Economic and Environmental Geology
    • /
    • v.43 no.2
    • /
    • pp.197-205
    • /
    • 2010
  • Recently abrupt climate changes have been occurred in global and regional scales and $CO_2$ reduction technologies became an important solution for global warming. As a method of the solution shallow underground thermal energy storage (UTES) has been applied as a reliable technology in most countries developing renewable energy. The geothermal energy system using thermal source of soil, rock, and ground water in aquifer or cavern located in shallow ground is designed based on the concept of thermal energy recovery and storage. UTES technology of Korea is in early stage and consistent researches are demanded to develop environmental friendly, economical and efficient UTES systems. Aquifers in Korea are suitable for various type of ground water source heat pump system. However due to poor understanding and regulations on various UTES high efficient geothermal systems have not been developed. Therefore simple closed U-tube type geothermal heat pump systems account for more than 90% of the total geothermal system installation in Korea. To prevent becoming wide-spread of inefficient systems, UTES systems considering to the hydrogeothemal properties of the ground should be developed and installed. Also international collaboration is necessary, and continuous UTES researches can improve the efficiency of shallow geothermal systems.

Geometric Analysis of Fracture System and Suggestion of a Modified RMR on Volcanic Rocks in the Vicinity of Ilgwang Fault (일광단층 인근 화산암 암반사면의 단열계 기하 분석 및 암반 분류 수정안 제시)

  • Chang, Tae-Woo;Lee, Hyeon-Woo;Chae, Byung-Gon;Seo, Yong-Seok;Cho, Yong-Chan
    • The Journal of Engineering Geology
    • /
    • v.17 no.3
    • /
    • pp.483-494
    • /
    • 2007
  • The properties of fracture system on road-cut slopes along the Busan-Ulsan express way under construction are investigated and analyzed. Fracture spacing distributions show log-normal form with extension fractures and negative exponential form with shear fractures. Straight line segments in log-log plots of cumulative fracture length indicate a power-law scaling with exponents of -1.13 in site 1, -1.01 in site 2 and -1.52 in site 3. It is likely that the stability and strength of rock mass are the lowest in site 1 as judged from the analyses of spacing, density and inter-section of fractures in three sites. In contrast, the highest efficiency of the fracture network for conducting fluid flow is seen in site 3 where the largest cluster occupies 73% through the window map. Based on the field survey data, this study modified weighting values of the RMR system using a multiple regression analysis method. The analysis result suggests a modified weighting values of the RMR parameters as follows; 18 for the intact strength of rock; 61 for RQD; 2 for spacing of discontinuities; 2 for the condition of discontinuities; and 17 for ground water.

Analysis of Slope Stability using Cell Unit Evaluation (셀 단위 평가법을 이용한 사면의 안정성 평가)

  • Jang, Bo-An;Poong, Bo-Hyun;Jang, Hyun-Shic
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.405-414
    • /
    • 2008
  • When we evaluate slope stability, we regard the slope homogeneous and evaluate slope stability at the most dangerous portion of slope. However, since conditions and properties of rock mass/soil are different from one location to another within a single slope, slope stability evaluated by current concept can not represent slope correctly. This also result in over-reinforcement at the portion where reinforcement is not necessary. In order to solve these problems, we suggest a cell unit evaluation method in which we apply small rectangular cells in a slope and regard each cell as a single slope. In this method, slopes are classified into soil slope and rock slope depending on materials. Strength of rock, volumetric joint count, spacing of joints, condition of joints, ground water condition and so on are examined and SMR and condition index values are calculated. Finally, all data and results are presented as contour maps. We apply the cell unit evaluation method into 3 cut slopes. SMR values estimated by the new method are larger than those by current concept at most portions of slope, indicating that the new method suggested by this research represent slope stability more correctly than methods which were used. This method will prevent over-reinforcement at the portion of slope where reinforcement is not necessary.

A development of the ground settlement evaluation chart on tunnel excavation (터널굴착에 따른 지반침하 예측을 위한 침하량 평가도표 개발)

  • Park, Chi Myeon;You, Kwang-Ho;Lee, Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1105-1123
    • /
    • 2018
  • The main risk factors of tunnel excavation through urban areas are ground settlement and surface sink which caused by ground conditions, excavation method, groundwater condition, excavation length, support method, etc. In the process of ground settlement assessment, the numerical analysis should be conducted considering the displacement and stress due to tunnel excavation. Therefore a technique that can simplify such process and easily evaluate the influence of tunnel excavation is needed. This study focused on the tunnelling-induced ground settlement which is main consideration of underground safety impact assessment. The parametric numerical analyses were performed considering such parameters as ground conditions, tunnel depth, and lateral distance from tunnel center line, etc. A simplified ground settlement evaluation chart was suggested by analyzing tendency of ground subsidence, lateral influence area and character by depth. The applicability of the suggested settlement evaluation chart was verified by comparative numerical analysis of settlement characteristics.

Geochemical Occurrence Characteristics of Geogenic Heavy Metals in Korea Evaluated Using Geochemical Map Data (전국 지화학도 자료를 이용한 지질기원 중금속의 지화학적 발생특성)

  • Ahn, Joo Sung;Youm, Seung-Jun;Cho, Yong-Chan;Yim, Gil-Jae;Ji, Sang-Woo;Lee, Jung-Hwa;Lee, Pyeong-Koo;Lee, Jeong-Ho;Shin, Seong-Cheon
    • Economic and Environmental Geology
    • /
    • v.55 no.4
    • /
    • pp.339-352
    • /
    • 2022
  • As environmental criteria items are increased or strengthened, cases of heavy metal contamination by geogenic origin are increasing, and the need to distinguish between natural and anthropogenic origins in soil or groundwater exceeding the standard is increasing. In this study, geochemical occurrences of geogenic heavy metals were identified through statistical processing of the national geochemical map data and evaluation of geochemical characteristics of regions with high geoaccumulation indices. Cobalt, Cr, Cu, Ni, Pb, V, and Zn were targeted for which the national geochemical maps were prepared, and Co, Cr, Ni, and V derived from ultrabasic or ultramafic rocks were classified as factor 1. Copper, Pb and Zn of non-ferrous sulfide origin were classified as factor 2. In particular, enrichment of heavy metals by factor 1 occurs mainly in the serpentine distribution areas of the Chungcheong region, and there is a risk of contamination in neighboring areas. In the case of factor 2, geogenic occurrence is concerned not only in non-ferrous metal mineralization areas such as Taebacksan and Gyeongnam mineralization zones, but also in Au-Ag mineralization areas distributed nationwide.

Study on Moye's Method for Analysis of Constant-Head Tests Conducted in Crystalline Rock (결정질 암반에서 Moye 방법을 이용한 정압시험의 해석에 대한 고찰)

  • Kyung-Woo Park;Byeong-Hak Park;Sung-Hoon Ji;Kang-Kun Lee
    • The Journal of Engineering Geology
    • /
    • v.33 no.4
    • /
    • pp.519-530
    • /
    • 2023
  • Moye's analytical solution was examined as a method for constant-head tests under steady-state conditions, and results were compared with transient-state analyses in in situ hydraulic tests. The sensitivity of hydraulic conductivities calculated using Moye's method increased with the length of the test section, which should be as large as possible under test conditions. Particularly in low-permeability media with less than 10-8 m/sec of hydraulic conductivity, hydraulic conductivity is lower than that under transient-state conditions and can be recalculated by adjusting the boundary between radial and spherical flow assumed in Moye's equation. Constant-head tests performed in the research borehole at the KAERI Underground Research Tunnel (KURT) indicated that transmissivities derived from the constant-head withdrawal test under transient-state conditions in low-permeability media were higher than those derived from steady-state tests, likely because the groundwater flow boundary was smaller than the "half of the test-section length"assumed by Moye's equation. When interpreting constant-head test results for crystalline rock, the hydrogeological properties of the medium may be better understood by considering assumed conditions accompanying analysis of the steady-state condition and comparing them with results for the transient-state analysis, rather than simply assuming properties based on steady-state analyses.