Groundwater Pollution Susceptibility Assessment of Younggwang Area Using GIS Technique (GIS기법을 이용한 영광지역의 지하수 오염 취약성 평가)

  • 이사로;최순학
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.4
    • /
    • pp.223-230
    • /
    • 1997
  • DRASTIC system developed by U.S.EPA, is widely used for assessing regional groundwater pollution susceptibility by using hydrogeological factors such as depth to water, net recharge, aquifer media, soil media, topography, vadose zone media, hydraulic conductivity. The system can be applied to site selection of well or waste disposal and landuse for groundwater protection. In this study, hydrogeological spatial database of Younggwang area about topography, drainage, well, geology, soil and landuse was constructed using GIS (Geographic Information System) and regional groundwater pollution susceptibility is analyzed using the spatial database and GIS overlay technique.

  • PDF

매립장 주변 대수층 매질특성과 수질의 상관관계 연구

  • O In-Suk;Go Gyeong-Seok;Gu Min-Ho;An Ju-Seong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.387-390
    • /
    • 2006
  • 매립장주변의 대수층 특성과 수리지화학적 특성과의 상관관계 분석은 매립장 환경 위해 요인을 평가하는데 중요한 역할을 하며 이를 위해 생활쓰레기 매립장인 금산 매립장을 대상으로 연구를 수행하였다. 대수층 매질 특성을 파악하기 위해 토양시료를 채취하여 중금속 성분 및 pH, 전기전도도, 용존유기탄소, 양이온교환능력, 유기물함량, 토양 입도분석을 수행하였고, 수리지화학적 특성 파악을 위해 수질검층 및 지하수 시료를 분석하여 매립지역의 수직 및 수평적인 분포 특성을 파악하였다. 대수층의 토양특성과 지하수 수질특성의 비교분석 결과 침출수 집수정을 기점으로 침출수의 영향을 받은 관측정의 전기전도도(EC) 측정값이 배경 지하수에 비해 상대적으로 높은 값을 보여 주었다. 입도분석 결과 상부 표토에 가까운 50cm 이내의 토양은 농경의 영향으로 심부보다 상대적으로 실트질 토양이 많고 이보다. 심부의 토양은 사질 토양으로 되어 있었다. 이러한 투수성이 좋은 사질 토양은 지하수의 이동을 비교적 쉽게 유도하기 때문에 매립장으로부터 침출수가 누출되었을 때 지하수 흐름을 따라 빠르게 이동할 수 있는 통로로 작용될 것으로 판단된다.

  • PDF

Fractal Model of Transient Flow in a Dual-porosity Aquifer with Constant-head Upper Boundary (일정수두 상부경계를 가지는 이중공극 대수층내 부정류에 관한 프락탈모델)

  • 함세영
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.2
    • /
    • pp.95-102
    • /
    • 1997
  • So far, several fractal models of fluid flow in a fractured aquifer have been developed. In this study, a new fractal model is derived that considers transient flow in the dual-porosity aquifer with the fracture skin between the fissure and the block, and the storage capacity and the wellbore skin on the pumping well. Constant-head upper boundary is specified in the block. This model is a generalized one which comprises both modified Hantush equation (1960) and Boulton-Streltsova equation (1978). Type curves are plotted for different flow dimensions (0.5, 1, 1.5, 2, 2.5 and 3) with various values of the leakage factor and the fracture skin. They show dimensionless drawdown in the pumping well and observation wells located either in the fissure system or in the matrix block.

  • PDF

A legislative Consideration for the Basic Information of Groundwater (지하수 기초정보 마련을 위한 입법정책 방안)

  • Kim, Jinsoo;Lee, Gyumin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.400-400
    • /
    • 2020
  • 현재 정부는 지하수 기초자료의 구축을 위해 '지하수 기초조사', '지하수 이용실태조사' 및 '지하수시설 전수조사'를 실시하고 있다. 지하수 기초조사는 「지하수법」 제5조(지하수의 조사)에 근거하여 실시되는데, 1990년 시범사업을 시작으로 30여 년 가까이 사업을 추진하고 있으나, 예산 및 인력 부족 등의 이유로 전국 전체에 대하여 조사를 완료하지 못하고 있는 실정이다. 지하수 기초조사 및 보완조사의 체계적인 시행을 위해 지하수관리기본계획에 지하수 기초조사 및 보완조사의 추진경과와 향후 계획을 비롯한 지하수 조사에 관한 사항을 포함하는 방안이 필요해 보인다. 지하수 이용실태조사는 「지하수법」 제17조(지하수의 관측 및 조사 등)제6항에 근거하여 시장·군수·구청장이 관할구역별로 조사·제출한 자료를 기반으로 작성되는데, 조사 결과에 대한 신뢰성 확보에 어려움을 겪고 있다. 각 지자체에서는 전문인력 및 예산 부족 등의 이유로 관련 규정에 따라 이용량을 산정하기보다는, 지하수 시설의 취수계획량을 이용량으로 대체하는 경우가 많기 때문이다. 지하수 이용실태조사 결과의 신뢰도를 높이기 위해서는 지자체 지하수 업무 담당자에 대한 교육 및 자료의 보완·개선 절차가 필요하다. 지하수시설 전수조사는 관정, 집수정, 지하댐 등 현재 사용 중인 시설과 더불어 사용하지 않거나 방치된 시설, 허가·신고하지 않고 사용하는 불법시설 등 지하수 관련 모든 시설을 조사한다. 과거 2009년부터 2014년까지 6년에 걸쳐 지하수시설 전수조사를 실시한 바 있으나, 아직까지 법적 근거가 마련되지 않은 상태이다. 불용공(不用孔)의 처리 및 불법시설 양성화 등을 위해 지하수시설 전수조사는 법적 근거와 조사의 방법, 대상 및 시행 절차 등에 관한 세부규정을 마련할 필요가 있다.

  • PDF

Solute Transport Modeling using Streamline Simulation in a Heterogeneous Aquifer with Multiple Contaminant Sources (불균질 대수층에서 유선 시뮬레이션을 이용한 다수 오염원의 용질 이동 모사)

  • Jung Seung-Pil;Choe Jong-Geun
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.3
    • /
    • pp.24-31
    • /
    • 2005
  • This study presents a contaminant transport model suitable for a 2-dimensional heterogeneous aquifer with multiple contaminant sources. It uses a streamline simulation, which transforms a multi-dimensional problem into multiple 1dimensional problems. It runs flow simulation, streamline tracking, and calculation of contaminant concentrations by turns. The model is verificated with a Visual MODFLOW by comparing contaminant concentration distributions and breakthrough curves at an observation well. Due to its fast simulation, it can be applied to time consuming simulations such as in a fine-grided aquifer, an inverse modeling and other applications.

Lead Transport in Groundwater in Door County, Wisconsin (위스컨신주 도어지역의 지하수내 납성분의 이동)

  • Woo, Nam C.
    • Economic and Environmental Geology
    • /
    • v.27 no.1
    • /
    • pp.93-100
    • /
    • 1994
  • This study examined the mechanisms of lead transport in the groundwater system and those of irregular detections in groundwater in Door County, Wisconsin. During the spring recharge period in 1991, water-level movement and water-quality change were monitored from two monitoring wells equipped with three piezometers each and from five house wells, respectively. Water-level responses to recharge events were fast with a relatively short lag time ranging from 3 to 10 days, indicating that recharge of groundwater occurs through the high hydraulic conductivity (K) zones in the Silurian dolomite aquifer system. Lead was detected only on particles filtered from groundwater, but not in dissolved state. Concentrations ranged from 0.2 to $7.1{\mu}g/mg$, converted into the total lead concentration in groundwater ranging from $0.3{\mu}g/l$ to $4.7{\mu}g/l$. A lag time between recharge events and peak particle movement at the sampled wells was estimated to range from 19 to 22 days. Due to the particulate nature of lead in groundwater, only the wells connected with the high K zones detect lead, causing the spatial variation. In a given well, lead concentration varies at different sampling times due to the variation in the initial amounts of lead-carrying particles introduced into the groundwater system during recharge events, the lag in particle transport and the dispersion of lead-carrying particles along the advective flowpaths.

  • PDF

Seasonal Variation of Cr(VI)-contaminated Groundwater Quality and the Potential for Natural Attenuation (6가 크롬 오염 지하수 수질의 계절변화와 자연저감 가능성)

  • Chon, Chul-Min;Ahn, Joo-Sung;Roh, Yul;Rhee, Sung-Keun;Seo, Hyun-Hee;Kim, Gue-Young;Koh, Dong-Chan;Son, Young-Chul;Kim, Ji-Wook
    • Economic and Environmental Geology
    • /
    • v.41 no.6
    • /
    • pp.645-655
    • /
    • 2008
  • The Cr(VI) concentrations at the shallow aquifer well (MPH-0-1) of the Moonpyung groundwater monitoring station were in the range of 0.5 to 3.1 mg/L exceeding 10 to 62 times the guideline for drinking-water quality, indicating continuous contamination. However, Cr was not detected at the deep bedrock well and the other subsidiary monitoring wells except for MPH-1 and 6. Cross-correlation analyses were conducted for rainfall and groundwater level time series, resulting in the mean time of recharge after precipitation events to be 5.6 days. For rainy season, the water level was raised and the Cr(VI) concentration was several times lower than that during dry season at well MPH-0-1 well. Correlation of the Cr(VI) concentration with the groundwater-level showed that the Cr(VI) reduction was closely related with the groundwater-level rise in the well. However, the groundwater level rise during high water season induced the lateral migration of the Cr(VI)-contaminated groundwater at well MPH-4. We enriched and isolated a chromium reducing bacteria, Enterobacter aerogenes, from the Cr(VI)-contaminated groundwater in the wells MPH-0-1 and MPH-1. The bacteria may play an important role for immobilizing Cr(VI) in the Cr(VI)-contaminated groundwater. Therefore, the migration of the contaminant (Cr(VI) must has been restricted because of the natural attenuation by microbial reduction of Cr(VI) in the groundwater. This research suggests that the bioremediation of the Cr(VI)-contaminated groundwater by the indigenous bacteria may be feasible in the Cr(VI) contaminated groundwater.

창원 강변여과수 취수지역의 지하수위와 낙동강 수위의 연관성 분석

  • Jeong, Jae-Yeol;Ham, Se-Yeong;Kim, Hyeong-Su;Han, Jeong-Sang;Son, Geon-Tae;Cha, Yong-Hun;Jang, Seong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.227-230
    • /
    • 2003
  • 시계열 분석 기법을 통하여 창원시 대산면 갈전리 강변여과수 취수지역의 지하수위와 하천수위와의 연관성을 살펴보았다. 연구지역의 6개 관측공의 30분 간격의 지하수위의 자기상관성을 분석한 결과, 세 개의 그룹으로 나타난다. 이 세 그룹은 낙동강으로부터 가까운 거리에 있으며 강한 자기상관성을 보이는 그룹(1그룹), 하천으로부터 비교적 가깝고 양수정으로부터 떨어져 있는 그룹(2그룹), 그리고 약한 자기상관성을 보이는 그룹(3그룹)으로 나타난다. 1그룹이 강한 자기상관성을 보이는 것은 낙동강의 영향 때문인 것으로 판단되며, 3그룹의 약한 자기상관성은 취수정의 양수의 영향으로 판단된다. 6개 관측공 지하수위와 낙동강 수위의 교차상관분석을 실시한 결과, 교차상관함수가 0.1이하의 낮은 교차상관성을 보이고 있다. 이는 취수정의 양수에 의한 관측공의 수위변동에 의해서 낙동강 수위와의 연관성이 잘 나타나지 않기 때문이다.

  • PDF

창원시 강변 여과수 취수에 관한 수리지질학적 특성 기초연구

  • 서형기;김형수;김진삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.261-264
    • /
    • 2002
  • 창원시 대산면과 북면에서의 강변여과수의 지속적 사용과 확장 개발에 따른 수리지질학적 환경 변화에 대한 자료를 확보하기 위하여 연구가 진행 중에 있으며 일부 내용을 소개하고자한다. 취수정 주위에서 현장투수시험기를 이용하여 현장포화수리전도도를 측정하였으며 5.19$\times$$10^{-}$$_4$~ 9.39$\times$$10^{-4}$$^4$/cm/s 사이의 값을 얻었다. 창원시에서 실시한 통수시험 자료에 따르면 시험기간 동안의 대산면 취수정 자연수위는 0.48~3.86m로써 낙동강의 수위 1m 내외보다 높은 것으로 관측되었다. 정호 당 약 80~90㎥/hour 양수할 경우 -5.3~l.6m의 수위를 나타내었으며 3, 4, 5호정보다 6, 7호정의 수위변동 폭이 큼을 확인하였다.

  • PDF

Parameter Estimation of Water Balance Analysis Method and Recharge Calculation Using Groundwater Levels (지하수위를 이용한 물수지분석법의 매개변수추정과 함양량산정)

  • An, Jung-Gi;Choi, Mu-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.4 s.165
    • /
    • pp.299-311
    • /
    • 2006
  • In this paper it is outlined the methodology of estimating the parameters of water balance analysis method for calculating recharge, using ground water level rises in monitoring well when values of specific yield of aquifer are not available. This methodology is applied for two monitoring wells of the case study area in northern area of the Jeiu Island. A water balance of soil layer of plant rooting zone is computed on a daily basis in the following manner. Diect runoff is estimated by using SCS method. Potential evapotranspiration calculated with Penman-Monteith equation is multiplied by crop coefficients($K_c$) and water stress coefficient to compute actual evapotranspiration(AET). Daily runoff and AET is subtracted from the rainfall plus the soil water storage of the previous day. Soil water remaining above soil water retention capacity(SWRC) is assumed to be recharge. Parameters such as the SCS curve number, SWRC and Kc are estimated from a linear relationship between water level rise and recharge for rainfall events. The upper threshold value of specific yield($n_m$) at the monitoring well location is derived from the relationship between rainfall and the resulting water level rise. The specific yield($n_c$) and the coefficient of determination ($R^2$) are calculated from a linear relationship between observed water level rise and calculated recharge for the different simulations. A set of parameter values with maximum value of $R^2$ is selected among parameter values with calculated specific yield($n_c$) less than the upper threshold value of specific yield($n_m$). Results applied for two monitoring wells show that the 81% of variance of the observed water level rises are explained by calculated recharge with the estimated parameters. It is shown that the data of groundwater level is useful in estimating the parameter of water balance analysis method for calculating recharge.