• Title/Summary/Keyword: 지하수유동

Search Result 506, Processing Time 0.023 seconds

A Study on the Measurement of Gas Discharge from the Gas Vent of Sanitary Landfill(1)- analysis for minimizing the measurement error of flow meter - (쓰레기 매립지 가스포집관에서 유출가스 계측에 관한 연구(1) -유량계 계측오차의 최소화를 위한 해석 -)

  • 이해승;이찬기
    • Journal of Korea Soil Environment Society
    • /
    • v.3 no.1
    • /
    • pp.83-92
    • /
    • 1998
  • This study presents a relationship between gas quantity and measurement resistance using the bubble meter, the water head indicator and the rotor meter from the gas vent sanitary landfill. From the one-dimensional analyses and experiments, the below results have been obtained. The gas volume sourcing from the gas vent depends on the permeability of final cover soil, its cover depth and distance between the gas vents. The total gas volume producing in the interested domain may be accurately measured by the bubble meter, the water head indicator and the rotor meter if the clay is used for the final cover soil. The required times approaching to the steady-state are different with respect to the flow meters, one day is for the bubble meter and the water head indicator and one hour for the rotor meter.

  • PDF

Characteristics of Groundwater Levels Fluctuation and Quality in Ddan-sum Area (낙동강 하중도 딴섬의 지하수위 변동 및 수질 특성)

  • Kim, Gyoobum;Choi, Doohoung;Shin, Seonho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.2
    • /
    • pp.35-43
    • /
    • 2011
  • Confined aquifer, which is separated with upper clayey or silty materials, is partially distributed at the depths of the sediments in Ddan-sum area on the lower Nakdong river. Measurements of groundwater levels at 13 sites explain that groundwater flow shows seasonally various due to seasonal rainfall and agricultural water use. From 9 long-term monitoring data of groundwater levels at 7 sites, 3 types of groundwater levels time series can be classified using principal component analysis. The first type is seen in the center of Ddan-sum and has a round-shape graph due to a weak response to stream water levels. The second type exists in the outer part of Ddan-sum and shows sharply peak-shape graph due to a rapid and strong response to stream water levels and rainfall. The last type, which is seen in a deep layer, has a periodicity by tital effect. From geochemical analysis at each monitoring sites, [$Ca-HCO_3$] type happens in the center of Ddan-sum far from Nakdong river, and [$Na-HCO_3$] and [$Ca-SO_4(Cl)$] types exist in the outer of Ddan-sum affected by river quality.

Detection of Potential Flow Paths of Leaked CO2 from Underground Storage Using Electrical Resistivity Survey (전기비저항탐사 방법에 의한 지중 저장 이산화탄소 누출 가능 경로 탐지)

  • Lim, Woo-Ri;Hamm, Se-Yeong;Hwang, Hak-Soo;Kim, Sung-Wook;Jeon, Hang-Tak
    • The Journal of Engineering Geology
    • /
    • v.28 no.1
    • /
    • pp.69-79
    • /
    • 2018
  • The Korean government attempts to reduce $CO_2$ emissions by 37% to 314.7 Mt $CO_2$, down from the estimated 850.6 Mt $CO_2$ until 2030 in order to confront green house effect. In this context, in 2014, Korean government launched $CO_2$ Storage Environmental Management Research (K-COSEM) Center for carrying out pilot-scale research on $CO_2$ leakage from underground $CO_2$ storage facilities. For the detection of $CO_2$ leakage, it is necessary to identify hydrologeological and geophysical characteristics of the subject area. In the study site of Naesan-ri, Daeso-myeon, Eumseong-gun, Chungbuk Province, two times injection tests (June 28-July 24, 2017 and August 07-September 11, 2017) of $CO_2$ and $SF_6$ dissolved waters, respectively, was conducted to understand the leakage behavior of $CO_2$ from underground. The injection well was drilled to a depth of 24 m with a 21-m casing and screen interval of 21~24 m depth. Two times resistivity surveys on August 18, 2017 and September 1, 2017, were conducted for revealing the flow of the injected water as well as the electrical properties of the study site. The study results have shown that the high-resistivity zone and the low-resistivity zone are clearly contrasted with each other and the flow direction of the injected water is similar to natural groundwater flow. Besides, the low resistivity zone is widely formed from the depth of injection to the shallow topsoil, indicating that the weathered zone of high permeability has high $CO_2$ leakage potential.

Analysis of the Characteristics of the Seismic source and the Wave Propagation Parameters in the region of the Southeastern Korean Peninsula (한반도 남동부 지진의 지각매질 특성 및 지진원 특성 변수 연구)

  • Kim, Jun-Kyoung;Kang, Ik-Bum
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.1 s.4
    • /
    • pp.135-141
    • /
    • 2002
  • Both non-linear damping values of the deep and shallow crustal materials and seismic source parameters are found from the observed near-field seismic ground motions at the South-eastern Korean Peninsula. The non-linear numerical algorithm applied in this study is Levenberg-Marquadet method. All the 25 sets of horizontal ground motions (east-west and north-south components at each seismic station) from 3 events (micro to macro scale) were used for the analysis of damping values and source parameters. The non-linear damping values of the deep and shallow crustal materials were found to be more similar to those of the region of the Western United States. The seismic source parameters found from this study also showed that the resultant stress drop values are relatively low compared to those of the Western United Sates. Consequently, comparisons of the various seismic parameters from this study and those of the United States Seismo-tectonic data suggest that the seismo-tectonic characteristics of the South eastern Korean Peninsula is more similar to those of the Western U.S.

Application of WEP Model to the Cheonggecheon Watershed (청계천 유역에 대한 WEP 모형의 적용)

  • Noh, Seong Jin;Kim, Hyeon Jun;Cheong, Il Moon;Jang, Cheol Hee;Kim, Dong Pil
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.148-152
    • /
    • 2004
  • 본 연구에서는 물순환의 재생이나 보전에 필수적인 유역 물순환의 정량화와 유역변화의 영향예측을 위해 개발된 WEP (Water and Energy Transfer Process) 모형의 국내 유역에 내한 적용성을 검토하고, 청계천 유역의 물순환 양상을 모의하였다. WEP 모형은 복잡한 토지이용이 이루어지고 있는 도시하천 유역에 내한 물순환의 정량화를 목적으로 일본의 토목연구소 (PWRI; Public Works Research Institute), 과학기술진흥사업단, Jia 박사 등에 의해 공동으로 개발되었으며 지표면 및 비포화 토양층의 물${\cdot}$열 플럭스 계산, 하도흐름의 추적계산 및 지하수 유동계산, 격자내 토지이용의 불균질성 반영 등이 가능한 물리적인 기반의 공간 분포형 모형 (Physically Based Spatially Distributed)이다. 모형을 적용한 청계천 유역 (유로연장 13.75 km, 유역 면적 $50.96km^2$)은 전체 토지이용중 도시지역이 $75.9\%$를 차지하고, 유역내 인구가 120만명에 이르는 도시유역으로 높은 불투수 면적비율, 인공계 물순환 요소의 영향 등의 도시 유역 특성이 물순환의 구조 전반에 미치는 영향에 대한 연구가 부족하였다. WEP 모형 적용 결과, 모의 기간 동안의 하천 유출량은 실측치에 근사한 값을 나타내었으며 유역의 물순환 양상을 모의할 수 있었다. 청계천 유역은 전형적인 도시 유역의 특성을 보여주었는데, 강우시의 직접유출이 크고, 강우의 유출에 대한 반응이 빠르며, 증발산의 경우는 산림지역보다 도시지역이 상대적으로 적은 것으로 분석되었다. 이번 연구를 통하여 WEP 모형이 유역 물순환 해석에 적절한 모형임을 확인할 수 있었으면, 향후 청계천 유역의 물리적 특성에 대한 매개변수와 인공계 물순환 자료의 보완을 통해 보다 향상된 모의가 가능할 것으로 판단된다. 하였던 Cd과 Mg이 Ca 및 Ca과 vitamin D의 동시(同時) 급여(給與)로 감소(減少)하였고 Cu는 전체적(金體的)으로 변화(變化)가 없었으며 Zn은 Cd 급여(給與)로 감소(減少)하였으나 Ca과 vitamin D의 급여(給與)에 의하여 증가(增加)하였고 Ca은 Ca과 viamin D의 급여(給輿)로 유의(有意)하게 증가(增加)하였다. 신장(腎臟)중의 무기질(無機質) 함량(含量)은 Cd급여(給輿)로 Cu, Mg은 감소(滅少)하였으나 Ca, Zn은 변화(變化)가 없었고 Ca 및 Ca과 Vitamin D의 급여(給與)로 Cd, CU, Zn은 증가(增加)하였다.ce area)는 수술 전100.8$\pm$25.6 mm/$m^{2}$에서 79.3$\pm$ 15.8 mm/$m^{2}$로 감소한 소견을 보였다. 승모판 성형술은 전 승모판엽 탈출증이 있는 두 환아에서 동시에 시행하였다. 수술 후 1년 내 시행한 심초음파에서 모든 환아에서 단지 경등도 이하의 승모판 폐쇄 부전 소견을 보였다. 수술 후 조기 사망은 없었으며, 합병증으로는 유미흉이 한 명에서 있었다. 술 후 10개월째 허혈성 확장성 심근증이 호전되지 않아 Dor 술식을 시행한 후 사망한 예를 제외한 나머지 6명은 특이 증상 없이 정상 생활 중이다 결론: 좌관상동맥 페동맥이상 기시증은 드물기는 하나, 영유아기에 심근경색 및 허혈성 심근증 또는 선천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조하여 적용할 필요가 있음을 시사하고 있다.교하여 유의한 차이가 관찰되지 않았다. 또한 HSP 환자군에서도 $IL1RN^{*}2$ allele 빈도와 carriage

  • PDF

International Case Studies on the Eco-friendly Energy Towns with Hybrid Thermal Energy Supply System and Borehole Thermal Energy Storage (BTES) (친환경에너지타운에서 보어홀지중열 저장(BTES) 활용 융복합 열에너지 공급 시스템 사례 연구)

  • Shim, Byoung Ohan
    • Economic and Environmental Geology
    • /
    • v.51 no.1
    • /
    • pp.67-76
    • /
    • 2018
  • This study reviews three eco-friendly energy towns with hybrid thermal energy supply systems and borehole thermal energy storage (BTES) in Canada and Denmark. The district heating and cooling systems were designed by using multi-source energy for the higher efficiency and reliability as well as environment. ADEU (Alexandra District Energy Utility) located at the developing area in the city of Richmond, Canada was designed to supply district energy with the installation of 726 borehole heat exchangers (BHEs) and a backup boiler using natural gas. DLSC (Drake Landing Solar Community) located in the town of Okotoks, Canada is a district system to store solar thermal energy underground during the summer season by seasonal BTES with 144 BHEs. Brædstrup Solpark district heating system located in Denmark has been conducted energy supply from multiple energy sources of solar thermal, heat pump, boiler plants and seasonal BTES with 48 BHEs. These systems are designed based on social and economic benefits as well as nature-friendly living space according to the city based energy perspective. Each system has the energy center which distribute the stored thermal energy to each house for heating during the winter season. The BHE depth and ground thermal storage volume are designed by the heating and cooling load as well as the condition of ground water flow and thermophysical properties of the ground. These systems have been proved the reliance and economic benefits by providing consistent energy supply with competitive energy price for many years. In addition, the several expansions of the service area in ADEU and Brædstrup Solpark have been processed based on energy supply master plan. In order to implement this kind of project in our country, the regulation and policy support of government or related federal organization are required. As well as the government have to make a energy management agency associated with long-term supply energy plan.