• Title/Summary/Keyword: 지하수위 변동

Search Result 260, Processing Time 0.035 seconds

Analyses of Hydrology and Groundwater Level Fluctuation in Granite Aquifer with Tunnel Excavation (터널 굴착에 의한 화강암 대수층의 수리 수문 및 지하수위변동 분석)

  • Chung, Sang-Yong;Kim, Byung-Woo;Kang, Dong-Hwan;Shim, Byoung-Ohan;Cheong, Sang-Won
    • The Journal of Engineering Geology
    • /
    • v.17 no.4
    • /
    • pp.643-653
    • /
    • 2007
  • Average hydraulic conductivity was $2.64{\times}10^{-8}m/sec$ average RQD was 78%, average porosity was 0.51%, and range of groundwater level was $77.06{\sim}125.97m$ by measured in 8 boreholes at the Surak Mt. tunnel area. Groundwater level of two peaks in the Surak Mt. tunnel area were estimated through linear regression analysis for groundwater level versus elevation. And, average horizontal hydraulic gradient in the Surak Mt. tunnel area was calculated 0.267. Minimum, maximum, and average hydraulic conductivities that estimated by field tests were $5.56{\times}10^{-9}m/sec,\;6.12{\times}10^{-8}m/sec,\;and\;2.64{\times}10^{-8}m/sec$, respectively. Groundwater discharge rates per 1 meter that estimated using minimum, maximum, and average hydraulic conductivities and average horizontal hydraulic gradient were $0.00585m^2/day,\;0.06434m^2/day,\;and\;0.02775m^2/day$, respectively. Pure groundwater recharge rate per unit recharge area was calculated 223.96 mm/yr through water balance analysis. Prediction simulation of groundwater level fluctuation with minimum, maximum, and average hydraulic conductivities were conducted. Discharge rate into the Surak Mt. tunnel for minimum hydraulic conductivity was small, but groundwaer drawdown was highly. Discharge rate into the Surak Mt. tunnel for maximum hydraulic conductivity was higher, but groundwaer level was recovered quickly.

Vulnerability Analysis for Groundwater Level Management in the Midstream of the Nakdong River (낙동강 중류 지역 지하수위 관리 취약성 분석)

  • Lee, Jae-Beom;Yang, Jeong-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.138-138
    • /
    • 2017
  • 가뭄, 집중호우와 같은 자연적인 요인과 불투수면적의 증가, 각종 용수로서의 지하수 이용 증가, 지하구조물 공사 등과 같은 인위적인 요인에 의한 지하수위 하강이 이슈화 되고 있다. 지하수 위의 하강은 지하수 고갈 같은 1차적 피해뿐만 아니라 생태계 교란, 농작물 피해, 지반 침하, 싱크홀 등의 2차 피해를 야기한다. 이에 따라 지하수위 시계열 자료를 이용하여 지하수위 관리 취약성에 대한 분석을 실시하였다. 연구지역으로 낙동강 중류에 위치한 상주, 대구, 밀양 지역으로 선택하였다. 자료 수집으로 국가지하수정보센터(www.gims.go.kr)에서 제공하는 국가지하수관측망 관측정 중 자료길이가 11개년 이상인 상주, 대구, 밀양의 지하수위 관측소의 일단위 지하수위 자료와 지하수이용량 자료를 수집하였다. 관측소 인근의 하천수위 자료는 국가수자원관리종합정보시스템(www.wamis.go.kr)에서 수집하였으며, 관측소 인근의 강수자료는 기상청(www.kma.go.kr)에서 해당 지역 관측소의 일단위 강수 자료를 수집하였다. 연구지역의 지하수 함양 자료는 국가통계포털(www.kosis.kr)에서 수집하였다. 수집한 일 단위 수문 자료를 이용하여 각 관측소의 연평균, 갈수기, 풍수기에 대해서 연구지역의 지하수위 관리 취약성 분석을 실시했고, 자료 분석 시 충적층 지하수위 자료는 인근 수계에 따른 변동이 크기 때문에 암반층 지하수위 자료에 대해서 분석을 실시하였다. 분석한 결과는 표준화 과정을 거쳐 지수로 산정하였고, 산정된 지수를 통해 연구지역 내 지하수위 관리 취약성 분석을 실시하였다. 본 연구를 전국단위 국가지하수관측망으로 적용하게 되면 지하수 개발 및 관리 정책 수립에 있어 큰 도움이 될 것으로 생각된다.

  • PDF

The hydraulic characteristics with tidal effect for pumping test at the costal rock aquifer (해안가 암반대수층에서 양수시험 시 조석효과에 의한 수리특성)

  • Kim, Tae-Yeong;Kang, Dong-Hwan;Kim, Sung-Soo;Kim, Dong-Soo;Chung, Sang-Yong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1929-1933
    • /
    • 2008
  • 조석에 의한 지하수위변동이 발생하는 해안가 암반대수층에서 고조(high tide)과 저조(low tide) 조건에서의 차이를 규명하기 위한 양수시험이 수행되었다. 본 연구에서 양수시험이 수행된 시험대 수층은 암반층으로서 시험공들은 해안가에서 약 180 m 이격되어 있으며, 양수정(MW1공)과 관측정(MW2공)의 이격거리는 8.05 m 이다. 양수정과 관측정 모두 공 내경은 0.205 m 이며, 케이싱심도는 지표면하 19 m 정도이다. 그리고, 양수정과 관측정의 지하수위는 지표면하 5 m 정도에 형성 되어 있으며, 시험대수층의 두께는 약 40 m 정도이다. 양수시험은 총 3회 수행되었으며, 모든 시험에서 수중모터 설치심도는 지표면하 30 m 이고 양수율은 $75\;m^3/day$로서 동일하였다. 그러나, 양수시작 시간의 차이를 두어 고조 후 1회(1차 시험), 저조 후 2회(2차 및 3차 시험) 수행되었다. 양수정과 관측정에서 자동수위측정기(Model 3001, Solinst)를 설치하여 관측된 지하수위변동 자료에 의하면, 조석현상 발생 후 시험공 내 지하수위변동 경과시간은 고조(high tide) 후 2시간, 저조 (low tide) 후 1시간 정도인 것으로 나타났다. 따라서, 양수시험 시 1차 시험은 고조 후 2시간 경과한 시점에서, 2차 및 3차 시험은 저조 후 1시간 경과한 시점에서 양수가 시작되었다. 양수시험에 의한 경과시간에 따른 수위강하량 그래프에서는 고조조건이 저조조건에 비해 수위강하량이 더 적은 것으로 나타났다. 이러한 원인은 저조에 비해 고조 조건에서는 해수에 의한 지하수위가 상승하여, 동일한 양수조건에서 수위강하량이 적게 나타난 것이다. 양수시험 자료가 AQTESOLV 3.5 프로그램을 이용하여 해석되었다. Theis method에 의해 산정된 수리전도도는 고조 조건의 양수시험에서는 $4.159{\times}10^{-6}\;m/sec$, 저조 후에서는 각각 $3.818{\times}10^{-6}\;m/sec$$3.926{\times}10^{-6}\;m/sec$ 이었다. 저조 후에 비해 고조 후의 수리전도도가 5% 이상 높은 것으로 산정되었다. 이상의 연구 결과들에 의해, 해안가 암반대수층에서는 양수시험 시 조석효과에 의한 수리적인 변동을 고려한 설계와 해석이 수행되어야함을 확인할 수 있었다.

  • PDF

Comparative Analysis of the Evaluation Method for Vunlnerable Period of Groundwater Level Drawdown in the Inland Area, Korea (내륙지역 지하수위 하강 취약시기 평가 방법 비교 분석 (가뭄 대응 지하수 활용 기술))

  • Lee, Jae-Beom;Yang, Jeong-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.412-412
    • /
    • 2020
  • 기후변화로 인한 강우사상의 변화, 수자원 환경의 변화로 인하여 최근 한반도에 발생한 가뭄시기에 기존의 지표수자원 위주의 수자원 개발은 용수 확보의 측면에서 한계점이 발생하였다. 지하수자원은 최근 지속가능하고 안정적인 수원으로서 역할이 중요해지고 있는 상황이다. 본 연구는 지하수자원의 정량적 평가를 위하여 지하수자원을 대표할 수 있는 인자로 지하수위를 선택하였고, 남원시의 9개 소유역을 대상으로 시공간의 변동을 고려한 월 단위 지하수위 관리 취약성 평가 방법을 개발하였다. 지하수위 취약 시기 평가에서 강수의 지하대수층에 대한 영향을 고려하고 강수 자료의 적용 방법에 따라 유효 우량을 적용하는 방법과 한계침투량 개념을 적용한 강수 자료를 이용하는 방법을 이용하였고 취약 시기 평가 결과를 비교하였다. 지하수위 취약 시기 평가 기준을 개발하고, 엔트로피 방법을 이용하여 가중치를 선정하였으며 다중의사결정 방법을 통해 소유역 별로 지하수자원 취약 시기를 평가하였다. 본 연구에서 개발된 방법은 시공간적인 지하수자원의 효율적 관리 대책 수립의 근거가 될 수 있을 것으로 기대된다.

  • PDF

Analysis of hydraulic gradient variation according to topographic gradient and rainfall in unconfined aquifer (자유면 대수층에서 지형 경사와 강우를 고려한 수리경사 변동 분석)

  • Kim, Byung-Woo;Kang, Dong-hwan;Jo, Won Gi;Park, Kyoung-deok
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.10
    • /
    • pp.691-695
    • /
    • 2023
  • In this study, two sections with different topographic gradients were in the Hyogyo-ri area, the hydraulic gradients were calculated for each section, and the hydraulic gradient fluctuations according to the topographic gradient and rainfall were analyzed. The variations of the hydraulic gradient within the research site was large in the section with steep topographic gradient and small in the section with gradual topographic gradient. The influence of the variation in hydraulic gradient due to rainfall was high in the section with steep topographic gradient, and low in the section with gradual topographic gradient. Through this study, it was found that the hydraulic gradient fluctuations in unconfined aquifer showed as a complex effect of topographic gradient and rainfall.

Estimation of Specific Yield Using Rainfall and Groundwater Levels at Shallow Groundwater Monitoring Sites (충적층 지하수 관측지점의 강우량 대비 지하수위 변동 자료를 활용한 비산출율 추정)

  • Kim, Gyoobum
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.6
    • /
    • pp.57-67
    • /
    • 2010
  • Specific yield is an essential parameter of the water table fluctuation method for recharge calculation. Specific yield is not easily estimated because of limited availability of aquifer test data and soil samples at National Groundwater Monitoring Stations in South Korea. The linear relationship between rainfall and water level rise was used to estimate the specific yields of aquifer for 34 shallow monitoring wells which were grouped into three clusters. In the case of Cluster-1 and Cluster-2, this method was not applicable because of low cross correlation between rainfall and water level rise and also a long lag time of water level rise to rainfall. However, the specific yields for 19 monitoring wells belonging to Cluster-3, which have relatively high cross correlation and short lag time, within 2 days after rainfall, range from 0.06 to 0.27 with mean value of 0.17. These values are within the general range for sand and gravel sediments and similar to those from aquifer test data. A detailed field survey is required to identify monitoring sites that are not greatly affected by pumping, stream flow, evapotranspiration, or delayed response of water levels to rainfall, because these factors may cause overestimation of specific yield estimates.

Evaluation of Long-term Data Obtained from Seawater Intrusion Monitoring Network using Variation Type Analysis (변동유형 분석법을 이용한 해수침투 관측망 자료 평가)

  • Song, Sung-Ho;Lee, Jin-Yong;Yi, Myeong-Jae
    • Journal of the Korean earth science society
    • /
    • v.28 no.4
    • /
    • pp.478-490
    • /
    • 2007
  • With groundwater data of seawater intrusion monitoring network in coastal areas of Korea's main land, we analyzed types of seawater intrusion through the coastal aquifer. The data including groundwater level, temperature and electrical conductivity obtained from 45 monitoring wells at 25 watershed regions were evaluated. Based on statistical analysis, correlation analysis and variation type analysis, groundwater levels were mainly affected by rainfall and artificial pumping. About 78% of the monitoring wells showed average temperature higher than $15^{\circ}C$ and about 58% of them showed minimum variations less than $0.2^{\circ}C$. Electrical conductivities showed a large magnitude of variation and irregular characteristics compared with groundwater levels and temperatures. Average electrical conductivities lower than $2,000\;{\mu}S/cm$ were observed at 28 monitoring wells while those of higher than $10,000\;{\mu}S/cm$ were done at 9 monitoring wells. From the cross-correlation analysis, groundwater levels were mostly affected by precipitation while temperature and electrical conductivity showed very low correlation. Meanwhile tidal variations strongly affected the groundwater levels comparing to precipitation. We classified the long-term monitoring data according to variation types such as constant process, linear trend, cyclic variation, impulse, step function and ramp. Impulse type was dominant for variations of groundwater level, which was largely affected by rainfall or artificial pumping, the constant process was dominant for temperature. Compared with groundwater level and temperature, electrical conductivities showed various types like linear trend, step function and ramp. According to the discrepancy of variation characteristics for monitoring data at each well in the same region, periodical analysis of monitoring data is essentially required.

Time Series Analysis of Groundwater Level Change in the Chuncheon Area Groundwater Observation Network (시계열 분석을 이용한 춘천 지역 지하수관측망 수위변동 해석)

  • Mok, Jong-Koo;Jang, Bum-Ju;Park, Yu-Chul;Shin, Hye-Soo;Kim, Jin-Ho;Song, Se-Jeong;Hawng, Ga-Young
    • The Journal of Engineering Geology
    • /
    • v.32 no.2
    • /
    • pp.281-293
    • /
    • 2022
  • Time series analysis was performed on data from 2009 to 2018 from the Chuncheon groundwater observation network to understand the characteristics of groundwater level fluctuations in the network. There are five observatories, all of which are installed in rock aquifers, and periodic inspections and management are performed by the relevant operating organization. Auto-correlation, spectral density, and cross-correlation analysis was performed.

A study on the analysis of groundwater falling by subsurface dam (지하댐 건설로 인한 주변부 지하수위 하강 분석 연구)

  • Oh, Jun Oh;Young, Jeon Ju;Park, Jae Hyeon;Jun, Sang Mi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.117-117
    • /
    • 2017
  • 울산시는 반구대 암각화 보존과 시민들을 위한 청정원수 공급과의 갈등을 지난 20년간 논의해 왔다. 이는 반구대 암각화 보존을 위하여 사연댐 수위를 낮추어 관리하여 발생하는 12.0만$m^3$의 용수부족량분과 장래 용수부족량분 30.0만$m^3$에 대하여 낙동강원수를 사용하여야 하는데 사연댐에 비해 수질이 나쁜 낙동강 원수사용의 비율이 높아지면 정수비용 증가로 인한 시민의 부담이 증가한다는 울산시의 입장과 반구대 암각화 보존을 위하여 사연댐의 수위를 낮추어 관리해야 한다는 문화재청의 입장으로 마찰을 빚어왔다. 이에 울산시의 신규 수자원 개발의 필요성이 대두되었고 그 방안으로 지하댐건설이 하나의 대안으로 제시되었다. 이에 본 연구에서는 울산시 울주군 사연리 주변에 지하댐이 건설된다면 그 주변 지하수위 변화에 대하여 지하수 모델(Visual-MODFLOW)를 사용하여 분석하였다. 먼저 울산시 울주군 사연리 인근에 지하댐을 건설한다면 일 30.0만$m^3$의 취수가 가능한지에 대한 여부를 분석하였으며, 가능하다면 용수취수로 인한 주변부 지하수위 하강이 어떻게 발생하는지에 대하여 분석하였다. 그 결과 일 30.0만$m^3$의 용수취수가 가능한 것으로 분석되었으며, 그로 인한 지하수위 하강은 취수정이 설치된 지점에서는 최대 1.8m의 지하수위 하강이 발생하며, 그 영향반경은 약 50.0m인 것으로 분석되었다. 또한 지하수위 하강이 약 0.3m ~ 1.8m까지 발생하는데 그 반경은 최대 약 700.0m 인 것으로 분석되었다. 본 연구 결과를 바탕으로 울산시 신규 수자원 개발을 위하여 지하댐을 건설이 가능할 것으로 판단되며 만약 울산시 신규 수자원으로 지하댐을 건설한다면 추가 정밀조사를 통하여 정확한 지하수위 변동 특성을 분석해야 할 것으로 판단된다.

  • PDF

Analysis of Groundwater Recharge Characteristics Using Relationship between Rainfall and Groundwater Level (강우량과 지하 수위를 이용한 지하수 함양특성 분석)

  • Lee, Dong-Ryul;Gu, Ho-Bon
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.1
    • /
    • pp.51-59
    • /
    • 2000
  • A dynamic model, which combined time series model with distributed-lag model, is applied to understand the relationship between rainfall and groundwater level. In the model, rainfall with distribution lags and past groundwater level as a dependent variables were used to estimate present groundwater level. The distribution of the lagged rainfall effects for groundwater levels was modeled by Almon polynomials. The model was applied to Banglim and Tanbu groundwater stations in Pyungchang river and Bocheong stream watershed which are representative basins for International Hydrological Program (IHP). The dynamic model represents observed groundwater levels very well and can be used to predict the levels. The model parameters reflect hydraulic characteristics of aquifer. In addition, from the parameters it appears that the increase in groundwater level due to rainfall takes place significantly within first two days of the rainfall event. The rainfall of the order of 18mm/day and 30mm/day at Banglim and Tanbu, respectively, had no significant effect on the groundwater levels.

  • PDF