• Title/Summary/Keyword: 지하수위 강하

Search Result 67, Processing Time 0.034 seconds

Relationship between Groundwater Level Changes and Aquifer Characteristics during Pumping at a Radial Collector Well (방사형 집수정 취수시 대수층 특성에 따른 지하수위의 변화)

  • Choi, Myoung-Rak;Lee, Ho-Jeong;Kim, Gyoo-Bum
    • The Journal of Engineering Geology
    • /
    • v.29 no.3
    • /
    • pp.279-288
    • /
    • 2019
  • The groundwater drawdown at each monitoring well near a radial collector well along Anseong Stream, Korea, was measured and compared with the calculated drawdown using the mirror well concept. The drawdown calculation is performed by treating the collector well as a large vertical well in a homogeneous isotropic aquifer. The measured drawdown at each monitoring well is slightly different from the calculated value due to anisotropy in the hydraulic conductivity and aquifer thickness. The difference between the measured and calculated values at Well OW-7 is large, reaching approximately 48 cm, because a horizontal well is not installed along this direction. Sensitivity analysis of the hydraulic conductivity and aquifer thickness indicates that the hydraulic conductivity is more sensitive to groundwater level changes. Groundwater level changes become a concern when a radial collector well with a large pumping rate capacity is installed, which highlights the need to thoroughly investigate the aquifer characteristics in the surrounding area.

URT 주변의 지하수유동체계 해석

  • Jo Seong-Il;Kim Cheon-Su;Bae Dae-Seok;Kim Gyeong-Su;Go Yong-Gwon
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.259-262
    • /
    • 2006
  • 본 연구는 지하처분연구시설(URT : Underground Research Tunnel)시설 건설공사와 관련하여 굴착 후의 지하수유동체계 변화를 예측하기 위하여 수행되었다. 지하수유동체계 모사를 위해 사용된 모델은 연속체 매질 개념의 Visual Modflow이며, URT 주변의 시추공에서 조사된 자료를 초기 입력자료로 이용하였다. 1단계 터널굴착 후에 계측된 지하수위 및 터널 내 지하수 유입량을 토대로 모델교정을 수행하였고, 교정된 모델을 이용하여 2단계 터널굴착 후의 지하수유동체계를 예측하였다. 1단계 굴착 후 약 4.3m의 수위강하가 발생한 KP-2번공은 2단계 굴착 후에는 약 0.05m의 수위강하가 예측되었다. 또한 2단계 굴착 후의 지하수위는 터널 입구를 기준으로 약 108m지점부터 터널 종점부 175m까지는 터널 상부에 분포하며, 종점부 175m지점에서는 지하수위가 터널 천장(roof)부로부터 약 12.7m 상부에 위치하는 것으로 예측되었다. 지하수위의 강하범위는 터널 중심부로부터 반경 약 300m까지 발생되는 것으로 예측되었고, 예상 지하수 유입량은 24.7ton/day로 1단계 공사 후보다. 약 2.7ton/day 증가하며, 공동굴착 전 터널 중심부의 지하수가 지표까지 도달하는 시간은 약 39.8년이 소요되는 것으로 나타났다.

  • PDF

Analysis of Groundwater-Level Variation Caused by Tunnel Construction at a Mountain Area (산악지역의 터널건설에 의한 지하수위 변동분석)

  • 강동환;정상용;심병완;김병우;정상원
    • Proceedings of the KSEG Conference
    • /
    • 2002.04a
    • /
    • pp.137-146
    • /
    • 2002
  • 수락산 터널구간 기반암의 평균투수계수는 $2.64{\times}10^{-6}cm/sec$, 평균RQD는 78%, 평균공극율 은 0.51% 이다. 지하수위와 표고간의 상관성분석을 이용하여 수락산 정상부에서 지하수위를 추정한 결과, 터널구간의 전체 평균수리경사는 0.267로서 산출되었다. 수리분석에 의한 수락산 터널구간에서의 지하수 유출량은 약 $66,378~121,574\textrm{m}^3/yr$, 함양량은 $863,500\textrm{m}^3/yr$로 산정 되었다. 3차원 지하수유동모델링 소프트웨어 MODFLOW를 이용하여 터널건설에 의한 지하수위 변동을 분석한 결과, 1년 후에는 터널 중심부에서의 지하수위 강하가 각각 40~45m로 나타났으며 터널구간의 지하수위는 3년 후에, 그리고 모델 영역 전체 지하수위는 4,5년 후에 완전하게 정류상태로 회복되었다.

  • PDF

Optimization of injection well position and amount to reduce the influence of groundwater level decrase due to riverside filtration (강변여과 취수로 인한 배후 지하수위 강하량 저감을 위한 최적의 주입정 위치 및 주입량)

  • Jang, Chi Woong;Park, Namsik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.388-388
    • /
    • 2017
  • 낙동강 하류 일대에는 수질과 수량 두 가지 요건을 모두 충족하는 강변여과수를 새로운 수자원 확보 대안으로 활용하고 있다. 일부 지역의 경우 과도한 취수량으로 인한 지하수 고갈을 우려하여 개발을 반대하거나 이로 인한 피해보상 범위가 명확치 않아 간접편입부지의 주민들이 피해를 우려하고 있는 실정이다. 따라서 해당 지역에서의 취수량은 인근 주민들에게 피해가 가지 않는 한도 내에서 이루어 져야한다. 하지만 타 지역으로 원수를 공급하게 되어 필요이상의 지하수를 개발하게 되거나 목표취수량에 부합하지 않아 추가 양수정을 시공하는 경우와 같이 수요량과 적정 취수량사이에 문제가 발생하는 경우가 있다. 이러한 배후 지하수위 감소영향과 추가취수량 확보를 위해 주입정을 활용한 인공함양 방법이 적용될 수 있다. 본 연구에서는 강변여과 취수 시 배후 지역의 지하수가 유입되어 인근 지역의 지하수위 강하량을 감소시키기 위한 최적 주입 위치 및 주입량을 산정하는 프로그램을 개발하였다. 고려된 최적화 결정변수는 주입정 개수와 위치, 그리고 주입량이며 제약 조건으로는 기 설치된 양수정 위치, 초기 자연 평형상태의 배후 지하수위에 근사하는 주입정 위치에 따른 최소 주입량 그리고 추가 생산 가능량 이다.

  • PDF

Sensitivity analysis of artificial recharge considering hydraulic conductivity and separation distance from injection well to pumping well (주입정과 양수정의 이격거리와 수리전도도를 고려한 인공함양 민감도 분석)

  • Kang, Dong-hwan;Jo, Won Gi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.285-285
    • /
    • 2020
  • 본 연구에서는 국내 시설농업단지의 수리지질 특성을 고려한 개념 모델을 설정하여 수리전도도와 이격거리(주입정과 양수정 사이의 거리)에 대한 민감도 분석을 수행하였다. 개념 모델에는 자연적 특성(지형과 지질, 강수량, 수리전도도 등)과 인공적 특성(주입정과 양수정의 이격거리, 주입량과 양수량 등)이 입력되었으며, 민감도 분석은 수리전도도(10-1 cm/sec, 10-2 cm/sec, 10-3 cm/sec, 10-4 cm/sec)와 이격거리(10 m, 50 m, 100 m)를 조합한 12개의 시나리오로 수행하였다. 양수정의 하류부에 설정된 관측정의 지하수위 강하량은 수리전도도가 감소하고 이격거리가 멀어질수록 증가하였다. 동일한 이격거리에서 수리전도도에 의한 지하수위 강하량의 회귀분석을 통해 인공함양 대수층의 지하수위 변동은 수리전도도에 의해 지배적인 영향을 받음을 알 수 있었다. 인공함양 대수층의 수리전도도가 10-2 cm/sec 이상인 조건에서는 주입정과 양수정의 이격거리에 따른 지하수위의 영향반경은 20 m 이내이었지만, 수리전도도가 10-3 cm/sec 이하인 조건에서는 이격거리가 멀어질수록 지하수위의 영향반경이 급격하게 증가함을 확인하였다.

  • PDF

A Study on the Determination of Management Groundwater Level on Jeju Island (제주도 지하수 관리수위 설정에 관한 연구)

  • Kim Ji-Wook;Koh Gi-Won;Won Jong-Ho;Han Chan
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.2
    • /
    • pp.12-19
    • /
    • 2005
  • Jeju island is one of the highest rainfall areas in the Korean peninsular. However, variation in rainfall amount is much great with years, which resulted in substantial variation in annual groundwater recharge and sustainable yield. Therefore, to cope with groundwater hazard including sea water intrusion and water level decline in accordance with successive extreme drought, Jeju province established a stepwise action system, in which management of representative monitoring wells and corresponding actions to water level conditions was enforced. In this study, rainfall and groundwater monitoring data were analyzed to determine management groundwater level on Jeju island. First, rainfall data for last 30 years were analyzed, which yielded a lower limit of rainfall at a confidence level of 99% as a basis rainfall. Only when the rainfall less than the basis rainfall was sustained over 3 months, the water levels were targeted for the analysis. For the water level data selected using the above criteria, the lower limit of 99% confidence interval was determined as a reference groundwater level. Finally, some ratios of reference groundwater level was determined as stepwise management groundwater level on Jeju island.

Assessment of groundwater inflow rate into a tunnel considering groundwater level drawdown and permeability reduction with depth (터널굴착 중 지하수위 강하 및 깊이별 투수계수 변화를 적용한 지하수 유입량 변화 분석)

  • Moon, Joon-Shik;Zheng, An-Qi;Jang, Seoyong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.2
    • /
    • pp.109-120
    • /
    • 2017
  • Groundwater seepage into a tunnel is one of the main causes triggering tunnel collapse and the consequent ground subsidence. Thus, it is important to estimate adequately the groundwater inflow rate and porewater pressure change during tunneling with time elapse. In current practice, Goodman's analytical solution (or image tunnel method) assuming homogeneous ground condition around a tunnel is commonly used for estimating groundwater inflow rate. However, the generally-used analytical solution for estimating groundwater inflow rate does not consider groundwater level drawdown and permeability change with depth, and the inflow rate can be overestimated in design phase. In this study, parametric study was performed in order to investigate the effect of groundwater level drawdown and permeability reduction with depth, and transient flow analysis was carried out for studying the inflow rate change as well as groundwater level and porewater pressure change around a tunnel with time elapse.

Determination of the Groundwater Yield of horizontal wells using an artificial neural network model incorporating riverside groundwater level data (배후지 지하수위를 고려한 인공신경망 기반의 수평정별 취수량 결정 기법)

  • Kim, Gyoo-Bum;Oh, Dong-Hwan
    • The Journal of Engineering Geology
    • /
    • v.28 no.4
    • /
    • pp.583-592
    • /
    • 2018
  • Recently, concern has arisen regarding the lowering of groundwater levels in the hinterland caused by the development of high-capacity radial collector wells in riverbank filtration areas. In this study, groundwater levels are estimated using Modflow software in relation to the water volume pumped by the radial collector well in Anseongcheon Stream. Using the water volume data, an artificial neural network (ANN) model is developed to determine the amount of water that can be withdrawn while minimizing the reduction of groundwater level. We estimate that increasing the pumping rate of the horizontal well HW-6, which is drilled parallel to the stream direction, is necessary to minimize the reduction of groundwater levels in wells OW-7 and OB-11. We also note that the number of input data and the classification of training and test data affect the results of the ANN model. This type of approach, which supplements ANN modeling with observed data, should contribute to the future groundwater management of hinterland areas.

지하유류저장시설 주변의 단열암반 내 지하수유동체계 해석

  • Jo Seong-Il;Kim Cheon-Su;Bae Dae-Seok;Kim Gyeong-Su;Park Gyeong-U;Song Mu-Yeong
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.292-295
    • /
    • 2005
  • 본 연구는 지하유류저장공동 굴착 시 비교적 정밀하게 해석된 단열체계 및 수리인자를 토대로 투수성구조영역과 수리암반영역으로 세분화하여 연구지역의 불규칙하고 복잡한 지하수유동체계를 해석해 보고자 하였다. FZ-2 구조대와 인접한 수리암반영역 Domain-A와 B는 Domain-C와 D에 비해 수평수벽공의 초기압이 최대 약 $15kg/cm^2$정도 높으며, 상 하부의 수리적 연결성이 양호하여 지하공동굴착 시 상 하부의 수위차가 크지 않고 지하수 함양량은 약 $35{\sim}50mm/year$의 범위를 보인다. 또한 공동굴착 시 투수성 단열과의 교차에 의한 수위강하에 민감한 반응을 보이며 상 하부의 수위강하양상이 유사한 특성을 나타낸다. 반면, FZ-1 구조대와 인접한 Domain-C와 D는 지하공동 부근의 수리전도도가 각각 $7{\times}10^{-10},\;2{\times}10^{-9}m/sec$로 Domain-A와 B에 비해 최대 약 6배정도 낮고, 상 하부의 수리적 연결성이 양호하지 않기 때문에 공동굴착 전 이중수위측정시설 설치 시 계측된 상 하부의 수위차는 최대 약 120 m로 매우 크다. 그리고 상부의 지하수는 하부의 낮은 수리전도도로 인하여 수직방향보다 수평방향으로의 유동이 우세하며 공동굴착 시 수위변화는 크지 않고 함양량은 $10{\sim}15mm/year$의 범위를 나타낸다.

  • PDF

The hydraulic characteristics with tidal effect for pumping test at the costal rock aquifer (해안가 암반대수층에서 양수시험 시 조석효과에 의한 수리특성)

  • Kim, Tae-Yeong;Kang, Dong-Hwan;Kim, Sung-Soo;Kim, Dong-Soo;Chung, Sang-Yong
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1929-1933
    • /
    • 2008
  • 조석에 의한 지하수위변동이 발생하는 해안가 암반대수층에서 고조(high tide)과 저조(low tide) 조건에서의 차이를 규명하기 위한 양수시험이 수행되었다. 본 연구에서 양수시험이 수행된 시험대 수층은 암반층으로서 시험공들은 해안가에서 약 180 m 이격되어 있으며, 양수정(MW1공)과 관측정(MW2공)의 이격거리는 8.05 m 이다. 양수정과 관측정 모두 공 내경은 0.205 m 이며, 케이싱심도는 지표면하 19 m 정도이다. 그리고, 양수정과 관측정의 지하수위는 지표면하 5 m 정도에 형성 되어 있으며, 시험대수층의 두께는 약 40 m 정도이다. 양수시험은 총 3회 수행되었으며, 모든 시험에서 수중모터 설치심도는 지표면하 30 m 이고 양수율은 $75\;m^3/day$로서 동일하였다. 그러나, 양수시작 시간의 차이를 두어 고조 후 1회(1차 시험), 저조 후 2회(2차 및 3차 시험) 수행되었다. 양수정과 관측정에서 자동수위측정기(Model 3001, Solinst)를 설치하여 관측된 지하수위변동 자료에 의하면, 조석현상 발생 후 시험공 내 지하수위변동 경과시간은 고조(high tide) 후 2시간, 저조 (low tide) 후 1시간 정도인 것으로 나타났다. 따라서, 양수시험 시 1차 시험은 고조 후 2시간 경과한 시점에서, 2차 및 3차 시험은 저조 후 1시간 경과한 시점에서 양수가 시작되었다. 양수시험에 의한 경과시간에 따른 수위강하량 그래프에서는 고조조건이 저조조건에 비해 수위강하량이 더 적은 것으로 나타났다. 이러한 원인은 저조에 비해 고조 조건에서는 해수에 의한 지하수위가 상승하여, 동일한 양수조건에서 수위강하량이 적게 나타난 것이다. 양수시험 자료가 AQTESOLV 3.5 프로그램을 이용하여 해석되었다. Theis method에 의해 산정된 수리전도도는 고조 조건의 양수시험에서는 $4.159{\times}10^{-6}\;m/sec$, 저조 후에서는 각각 $3.818{\times}10^{-6}\;m/sec$$3.926{\times}10^{-6}\;m/sec$ 이었다. 저조 후에 비해 고조 후의 수리전도도가 5% 이상 높은 것으로 산정되었다. 이상의 연구 결과들에 의해, 해안가 암반대수층에서는 양수시험 시 조석효과에 의한 수리적인 변동을 고려한 설계와 해석이 수행되어야함을 확인할 수 있었다.

  • PDF