• Title/Summary/Keyword: 지진조사

Search Result 439, Processing Time 0.026 seconds

Seismic Retrofit of School Facilities Using Rapping and Attaching Composite Material (부착 및 래핑형 복합소재를 이용한 학교시설의 내진보강)

  • Park, Choon-Wook;Kim, Dong-Hwi;Kwon, Min-Ho;Choi, Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.2
    • /
    • pp.135-142
    • /
    • 2014
  • In paper after the strong earthquake of recently the Korea neighborhood, the Korean government survey show that the 86% of school buildings in Korea are in potential damage risk and only 14% of them are designed as earthquake-resistance buildings. Earthquake Reinforcing projects of school have been a leading by the ministry of education, however their reinforcing methods done by not proved a engineering by experiment which results in uneconomical and uneffective rehabilitation for the future earthquake. An experimental and analytical study have been conducted for the shear reinforcing method of RC beam by axis and horizontal axis load using attaching composite beam. Based on the previous research, in this study, design examples are given to show the performance evaluation for the column reinforcing of old school buildings using nonlinear analysis is going to be conducted and strengthening method is going to be on the market after their performance is proved by the test.

광미적치장 사면의 안정성 해석 및 대책

  • Song, Won-Gyeong;Han, Gong-Chang;Sin, Jung-Ho
    • Geotechnical Engineering
    • /
    • v.14 no.3
    • /
    • pp.123-134
    • /
    • 1998
  • To analyse the stability of a slope composed of waste material produced in a closed lead mine, numerical modeling has been carried out in two dimension using FLAC, finite difference program. The research was focused on the effect of the earthquake as well as a rise of water table upon slope stability. The numerical results have shown that the slope would not be safe against earthquake event and that the increase of pore pressure due to a rise of water table up to the ground level may result in a failure of the slope. On the basis of numerical analyses and site investigation, two sorts of measures have been taken. In short term, removal of a part of materials deposited on the top of the pile is required to increase immediately safety factor of the slope even a little. In ling term, it is necessary to repair drainage facilities and dam which covers waste material so that the slope is prevented from failure in a radical manner. It has been confirmed by numerical analyses that an improvenment of the stability can be in a great extent expected after such measures have been performed.

  • PDF

Estimation of Modal Parameters for Plastic Film-Covered Greenhouse Arches (비닐하우스 아치구조의 모달계수 산정)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.67-74
    • /
    • 2010
  • To a series of vibration records obtained from experimental modal testing using a fixed hammer and roving accelerometers for greenhouse arch structures, modal parameters such as natural frequencies, damping ratios and mode shapes are extracted by applying the two most advanced system identification methods in the frequency-domain up to now, so-called PolyMAX and FDD. The former involves both input and output data, while the latter utilizes only the output data. The possibility of determining the static buckling load, detecting damages, etc., for very slender steel-pipe arches by means of a non-destructive testing method based on vibration measurements is primarily investigated. The extracted modal parameters generally correlated well with those obtained using finite element analysis, demonstrating promising results for further on-going research.

Modal Testing of Arches for Plastic Film-Covered Greenhouses (비닐하우스 아치구조의 모달실험)

  • Cho, Soon-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.57-65
    • /
    • 2010
  • To determine the static buckling loads and evaluate the structural performance of slender steel pipe-arches such as for greenhouse structures, a series of modal tests using a fixed hammer and roving sensors was carried out, by providing no load, then a range of vertical loads, on an arch rib in several steps. More attention was given to an internal arch where vertical and horizontal auxiliary members are not placed, unlike an end arch. Modal parameters such as natural frequencies, mode shapes and damping ratios were extracted using more advanced system identification methods such as PolyMAX (Polyreference Least-Squares Complex Frequency Domain), and compared with those predicted by commercial FEA (Finite Element Analysis) software ANSYS for various conditions. A good correlation between them was achieved in an overall sense, however the reduction of natural frequencies due to the existence of preaxial loads was not apparent when the vertical load level was about up to 38% of its resistance. Some difficulties related to the field testing and parameter extraction for a very slender arch, as might arise from the influences of neighboring members, are carefully discussed.

Analysis on In-Plane Behavior of Unreinforced Masonry Walls (비보강 조적벽체의 면내거동 해석)

  • 김장훈;권기혁
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.3
    • /
    • pp.1-10
    • /
    • 2002
  • A series of unreinforced masonry(URM) walls were analytically investigated by FEM for a limited version of seismic in-plane performance. For this, URM walls were assumed to be continum and modeled as isotropic plane stress elements, within which the nature of cracking was propogated. Accordingly, behavioral mode of cracking in URM was modeled by smeared-crack approach. Total of 70 cases were considered for various parameters such as axial load ratio, aspect ratio and effective section area ratio due to the existence of opening, etc. The analysis results indicate that these parameters significantly and interactively influence over the ultimate strength of URM walls. Finally, it is suggested that the response modification factor for URM adopted in the current Korean Standard should be validated considering various forms of brittleness and probable failure modes in URM.

Characteristics of Energy Dissipation in Nano Shock Suspension System Using Silica Gel (세라믹 분말을 이용한 나노 충격 완화 장치의 에너지 소산 효율 특성에 대한 연구)

  • 문병영;정성원
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.17-22
    • /
    • 2003
  • This paper presents an experimental investigation of a reversible colloidal seismic damper, which is statically loaded, The porous matrix is composed from silica gel (labyrinth or central-cavity architecture), coated by organo-silicones substances, in order to achieve a hydrophobic surface. Water is considered as associated lyophobic liquid. Reversible colloidal damper static test rig and the measuring technique of the static hysteresis are described. Influence of the pare and particle diameters, particle architecture and length of the grafted molecule upon the reversible colloidal damper hysteresis is investigated, for distinctive types and mixtures of porous matrices, Variation of the reversible colloidal damper dissipated energy and efficiency with temperature, pressure, is illustrated.

Evaluation of Liquefaction Triggering for the Pohang Area Based on SPT and CPT Tests (SPT와 CPT 지반조사결과에 기초한 포항지역 액상화 위험도 평가)

  • Kim, Yeon-Jun;Ko, Kil-Wan;Kim, Byung-Min;Park, Du-Hee;Kim, Ki-Seog;Han, Jin-Tae;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.10
    • /
    • pp.57-71
    • /
    • 2020
  • Liquefaction-induced sand boils were observed during the Pohang earthquake (Moment magnitude, 5.4) on November 15, 2017, specifically in the region of agricultural fields and park areas near the epicenter. This was recorded as the first observed liquefaction phenomenon in Korea. This paper analyzes liquefaction potentials at the key sites at Pohang area. The simplified methods and current design standard were used to evaluate the occurrence of liquefaction. The seismic demand was estimated based on the NGA-WEST2 ground motion prediction equations (GMPEs). The liquefaction resistance of the ground was determined using the in-situ tests: standard penetration test (SPT) and cone penetration test (CPT). The liquefaction potentials were quantified by liquefaction potential index (LPI), which were compared with those from the previous studies.

CASE Study: Policy implications of HAZUS analysis

  • Kim, Yong-Gyun
    • Magazine of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.1
    • /
    • pp.48-52
    • /
    • 2008
  • 대형태풍 카트리나가 준 주요 교훈 중의 하나는, 위험도 분석에 기반한 종합적인 재해경감 프로그램의 중요성이다. 미국에서는 이를 위해 다양한 위험도 분석(risk analysis) 프로그램 개발에 노력해 왔다. HAZUS(Hazarda-US) 프로그램은 대표적인 자연재해 예측 시스템으로서, 위험요인 파악(hazard identification), 지역사회의 취약성 분석(vulnerability of the society), 그리고 피해결과예측(loss estimation)의 세 가지 요소로 구성된다. 1992년 지진을 대상으로 개발된 이 프로그램은 현재, 지진 홍수 허리케인 윈드에 대해 피해예측을 할 수 있는 HAZUS-MH MR3가 사용 중에 있다. FEMA에서는 주정부에서 HAZUS를 활용, 피해 예측에 기반한 재해경감 정책을 추진할 수 있도록 다양한 재정적 기술적 지원을 하고 있다. 이에 따라, 2004년 머릴랜드 주에서는 미국 최초로 주 전역에 걸친 홍수피해 예측을 실히하고 이를 바탕으로 다양한 경감정책을 추진하였다. 머릴랜드 주정부에서 Salisbury 대학에 의뢰하여 수행한 홍수 피해 예측 과정은, 조사구역 및 위험요인(홍수) 결정, 사용 데이터 확정, 수문학적 분석, 수리학적 분석, 피해예측(건물 용도별 피해면적, 건물 용도별 피해액, 건물 재질별 피해면적, 건물 재질별 피해액, 지역의 경제학적 피해)의 과정으로 수행되었다. 홍수피해 예측 결과, 100년 빈도 홍수가 재현될 경우, 주 전체 면적 중 13%이상의 지역에서 약 80조 이상의 피해액이 예측됨에 따라, 종합적인 재해경감 대책의 필용성이 제기되었다. 이에 따라, 머릴랜드 주정부에서는 홍수피해예측 결과를 토대로, 주정부 재해경감 예산 재분배, 홍수터 보호, 건물규제 강화, 토지이용계획 재조정 등 보다 과학적이고 종합적인 재해경감 프로그램을 추진하였다. 머릴랜드 주정부의 이번 연구는 주정부로서는 최초로 HAZUS를 활용하여 주 전역에 걸친 피해예측을 실시한 것으로서, 피해예측 시스템이 어떻게 주정부의 과학적 피해경감 프로그램에 기여할 수 있는 지를 보여주는 사례이다.

  • PDF

Dynamic Analysis of Soil-Pile-Structure Interaction Considering a Complex Soil Profile (복잡한 지반층을 고려한 지반-말뚝-구조물의 상호작용 동해석)

  • Park, Jang-Ho;Park, Jae-Gyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.21-28
    • /
    • 2009
  • The precise analysis of soil-pile-structure interaction requires a proper description of soil layer, pile, and structure. In commonly used finite element simulations, mesh boundaries should match the material discontinuity line. However, in practice, the geometry of soil profiles and piles may be so complex that mesh alignment becomes a wasteful and difficult task. To overcome these difficulties, a different integration method is adopted in this paper, which enables easy integration over a regular element with material discontinuity regardless of the location of the discontinuity line. By applying this integration method, the mesh can be generated rapidly and in a highly structured manner, leading to a very regular stiffness matrix. The influence of the shape of the soil profile and piles on the response is examined, and the validity of the proposed soil-pile structure interaction analysis method is demonstrated through several examples. It is seen that the proposed analysis method can be easily used on soil-pile-structure interaction problems with complex interfaces between materials to produce reliable results regardless of the material discontinuity line.

Nonlinear Seismic Analysis of Hollow Cast-in-place and Precast RC Bridge Columns with Triangular Reinforcement Details (삼각망 철근상세를 갖는 현장타설 및 조립식 중공 철근콘크리트 교각의 비선형 지진해석)

  • Kim, Tae-Hoon;Ra, Kyeong-Woong;Lee, Jae-Hoon;Shin, Hyun Mock
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.6
    • /
    • pp.713-722
    • /
    • 2016
  • The goal of this study was to assess the seismic performance of hollow cast-in-place and precast reinforced concrete bridge columns with triangular reinforcement details. The developed material quantity reduction details are economically feasible and rational, and facilitate shorter construction periods. By using a sophisticated nonlinear finite element analysis program, the accuracy and objectivity of the assessment process can be enhanced. The used numerical method gives a realistic prediction of seismic performance throughout the input ground motions for several hollow column specimens investigated. As a result, triangular reinforcement details were designed to be superior to the existing reinforcement details in terms of required seismic performance.